815 resultados para Gemstone Team ELECTRODE
Resumo:
Hydrogen peroxide is a powerful oxidant that finds application in several areas, but most particularly in the treatment of industrial wastewaters. The aim of the present study was to investigate the effects of applied potential and electrolyte flow conditions on the in situ generation of hydrogen peroxide in an electrochemical flow-by reactor with a gas diffusion electrode (GDE). The electrolyses were performed in an aqueous acidic medium using a GDE constructed with conductive black graphite and polytetrafluoroethylene (80:20 w/w). Under laminar flow conditions (flow rate = 50 L/h), hydrogen peroxide was formed in a maximum yield of 414 mg/L after 2 h at -2.25 V vs Pt //Ag/AgCl (global rate constant = 3.1 mg/(L min); energy consumption = 22.1 kWh/kg). Under turbulent flow (300 L/h), the maximum yield obtained was 294 mg/L after 2 h at -1.75 V vs Pt//Ag/AgCl (global rate constant = 2.5 mg/ (L min); energy consumption = 30.1 kWh/kg).
Resumo:
The objective of this cross-sectional, descriptive study was to identify the activities of the Nursing Intervention Classification considered as priorities for an Ineffective Breathing Pattern and not performed for elderly inpatients of a teaching hospital in the state of Goias. The study participants were 43 nursing professionals, and data collection was performed in the period spanning October to December 2008, after receiving approval from the Ethics Committee. It was observed that among the 67 activities considered to be priorities for the referred diagnosis, only seven were performed by all of the participants; the other activities, with a varied frequency, were not performed, with the main reason cited being that a professional from a different area completed the activity. It is understood that the fact that the nursing staff does not perform these activities can cause lack of complete coverage in nursing care; therefore there is a need for a legal apparatus to describe the activities that comprise professional practice exclusive to nursing personnel and those activities that have an interdisciplinary nature.
Resumo:
The thiadiazolylurea derivative tebuthiuron (TBH) is commonly used as an herbicide even though it is highly toxic to humans. While various processes have been proposed for the removal of organic contaminants of this type from wastewater, electrochemical degradation has shown particular promise. The aim of the present study was to investigate the electrochemical degradation of TBH using anodes comprising boron-doped (5000 and 30000 ppm) diamond (BDD) films deposited onto Ti substrates operated at current densities in the range 10-200 mA cm(-2). Both anodes removed TBH following a similar pseudo first-order reaction kinetics with k(ap)p close to 3.2 x 10(-2) min(-1). The maximum mineralization efficiency obtained was 80%. High-pressure liquid chromatography with UV-VIS detection established that both anodes degraded TBH via similar intermediates. Ion chromatography revealed that increasing concentrations of nitrate ions (up to 0.9 ppm) were formed with increasing current density, while the formation of nitrite ions was observed with both anodes at current densities >= 150 mA cm(-2). The BDD film prepared at the lower doping level (5000 ppm) was more efficient in degrading TBH than its more highly doped counterpart. This unexpected finding may be explained in terms of the quantity of impurities incorporated into the diamond lattice during chemical vapor deposition. (C) 2012 Elsevier Ltd. All rights reserved.
Resumo:
The objective of this study was to identify the professional factors affecting the quality of life of nurses working in the family health teams in the Macro Health Region, referred to as the South Triangle, in the State of Minas Gerais. This is a descriptive, cross-sectional study. The participants were 90 nurses, who answered a questionnaire containing the professional variables and the Quality of Life assessment instrument - WHOQOL-100. The results showed a negative impact regarding the number of jobs, unstable jobs, excessive workload and job dissatisfaction in the nurses' Quality of Life domains. There is a need to (re)define the public policies that control the working conditions of these professionals. Actions that contribute towards improving nurses' Quality of Life are important, considering their strong influence on the quality of the healthcare that is delivered.
Resumo:
The use of standard reference electrodes, such as Ag/AgCl or saturated calomel electrodes, in potentiometric and amperometric studies involving miniaturized electrochemical systems, or those operating under positive hydraulic pressure, is often impractical. Placement of the reference electrode in the direct vicinity of the working electrode is often prohibited by the dimensions or layout of the electrochemical cell, while the alternative strategy of locating the reference electrode in a separate compartment often leads to electrolyte leakage and contamination of the system. In the present study, we have investigated the functionality of a pseudoreference electrode comprising a platinum wire, one end of which was maintained in intimate contact with the internal solution of an Ag/AgCl reference electrode while the other was connected, via a BNC connector, to a platinum probe located within the electrochemical cell. Linear and cyclic voltammetric studies, involving both aqueous and nonaqueous electrolytes, were carried out using the pseudoreference electrode and an electrochemical cup-type cell with three electrodes or an electrochemical flow reactor. In all cases, the functionality of the Pt//Ag/AgCl system was similar to that of a conventional Ag/AgCl reference electrode. Variations in the electrolyte did not alter the potential or voltammetric profile recorded when using the pseudoreference system, although peak currents were generally improved and potential values shifted by approximately +350 mV in comparison with the Ag/AgCl electrode, therefore, the system pseudoreference can be applied in any electrochemical system due to the constant potential difference. It is concluded that the pseudoreference electrode can be used with advantage to obtain potentiometric and amperometric measurements in both simple and complex electrochemical systems.
Resumo:
The purpose of this study was to determine the physiological, anthropometric, performance, and nutritional characteristics of the Brazil Canoe Polo National Team. Ten male canoe polo athletes (age 26.7 +/- 4.1 years) performed a battery of tests including assessments of anthropometric parameters, upper-body anaerobic power (Wingate), muscular strength, aerobic power, and nutritional profile. In addition, we characterized heart rate and plasma lactate responses and the temporal pattern of the effort/recovery during a simulated canoe polo match. The main results are as follows: body fat, 12.3 +/- 4.0%; upper-body peak and mean power, 6.8 +/- 0.5 and 4.7 +/- 0.4 W . kg(-1), respectively; 1-RM bench press, 99.1 +/- 11.7 kg; peak oxygen uptake, 44.3 +/- 5.8 mL . kg(-1) . min(-1); total energy intake, 42.8 +/- 8.6 kcal . kg(-1); protein, carbohydrate, and fat intakes, 1.9 +/- 0.1, 5.0 +/- 1.5, and 1.7 +/- 0.4 g . kg(-1), respectively; mean heart rate, 146 +/- 11 beats . min(-1); plasma lactate, 5.7 +/- 3.8 mmol . L-1 at half-time and 4.6 +/- 2.2 mmol . L-1 at the end of the match; effort time (relative to total match time), 93.1 +/- 3.0%; number of sprints, 9.6 +/- 4.4. The results of this study will assist coaches, trainers, and nutritionists in developing more adequate training programmes and dietary interventions for canoe polo athletes.
Resumo:
A novel amperometric sensor based on the incorporation of ruthenium oxide hexacyanoferrate (RuOHCF) into multiwalled carbon nanotubes (MWCNTs) immobilized on a glassy carbon electrode is described. Cyclic voltammetry experiments indicated that the cathodic reduction of hydrogen peroxide at the RuOHCF/MWCNTs100/GC modified electrode is facilitated, occurring at 0.0 V vs. Ag/AgCl/KCl(sat). Following the optimization of the experimental conditions, the proposed sensor presented excellent analytical properties for hydrogen peroxide determination, with a low limit of detection (4.7 mu mol L-1), a large dynamic concentration range (0.1-10 mmol L-1) and a sensitivity of 1280 mu A mmol(-1) L cm(-2). The usefulness of the RuOHCF/MWCNTs100/GC electrochemical sensor was confirmed by monitoring the consumption of hydrogen peroxide during the degradation of phenol by the Fenton reaction. (C) 2012 Elsevier B.V. All rights reserved.
Resumo:
This paper describes the preparation, characterization, and use of poly (methylene blue) (PMB)-modified glassy carbon electrodes (GCE) (GCE-PMB) in the detection of the thiols L-cysteine (L-CySH) and N-acetyl cysteine (Acy), and the herbicide glyphosate (GLYP) in pH 5.3 aqueous solution. The polymer film prepared by electropolymerization showed different characteristics such as robustness, stability, and redox properties satisfactorily. The surface coverage concentration (Gamma) of PMB was found to be 7.90 x 10(-9) - mol cm(-2). Moreover, we observed strong adhesion of the polymer film to the electrode surface. The results using GCE-PMB as a sensor indicated that this modified electrode exhibited electrocatalytic activity toward the detection of thiols and glyphosate in 0.1 mol L-1 KO (pH 5.3). Meanwhile, strong adsorption of the analytes on the GCE-PMB electrodes was also observed. Otherwise, using a low concentration (1 x 10(-4) mol L-1) of L-cysteine and N-acetyl cysteine and 8.9 x 10(-6) mol L-1 of glyphosate, separately, it was possible to observe a well-defined electrochemical response, thus providing an opportunity to further understand the applicability of PMB as a sensor for amino acid-based molecules. (C) 2012 Elsevier B.V. All rights reserved.
Resumo:
We used an assembly of electrodes C3 and C4-Cz in order to activate the motor cortical area of the corticobulbar tract to elucidate the motor-evoked potential of the contralateral mentalis muscle. We compared this setup to that of an assembly with electrodes C5 or C6-Cz using a train of electrical pulses and a single electrical pulse. This analysis was made in 23 consecutive patients who underwent several varied surgeries and were prospectively operated on at Santa Paula Hospital between January and June 2011. The results showed that the assembly with C5 or C6-Cz produced a multisynaptic motor-evoked potential in the contralateral mentalis muscle in 86.9 % of the patients, whereas 82.6 % of patients stimulated at points C3 or C4-Cz presented the same response. However, both assemblies showed similar behavior with the use of a single electrical pulse for peripheral contralateral nerve stimulation. We concluded that the C5 or C6-Cz assembly was similar to C3 or C4-Cz in obtaining a multisynaptic response in the contralateral mentalis muscle, although it required less intensive stimulation than the C3 or C4- Cz assembly.
Resumo:
Objectives: To establish normative amplitude values for relative difference measurements of the middle latency response (MLR) in normal-hearing pediatrics and to determine if these measurements provided a significant reduction of within-group variability when compared to raw, absolute amplitude measures. A relative amplitude difference is defined in the present paper as the difference in Na-Pa amplitude between two electrodes (e.g. vertical bar Na-Pa at C3 minus Na-Pa at C4 vertical bar, or electrode effects) or between two ears (e.g. vertical bar Na-Pa on left ear stimulation minus Na-Pa on right ear stimulation vertical bar, or ear effects). In contrast, an absolute amplitude is defined as a single Na-Pa measurement made at one electrode for stimulation of one ear (e.g. Na-Pa measured at C3 on left ear stimulation). Design: Cross-sectional study. Study sample: 155 pediatrics with normal peripheral and central hearing, and no history of psychological, neurological, or learning disability issues. Results: Within-group variability was significantly smaller for relative differences when compared to absolute amplitude measures. Electrode effects showed significantly less variability than ear effects. Normative values for ear and electrode effects were reported. Conclusions: Relative differences may provide better utility in the clinical diagnosis of central auditory pathology in pediatrics when compared to absolute amplitude measures because these difference measures show significantly lower variability when examined across subjects.
Resumo:
ELECTROCHEMICAL OXIDATION OF THE HERBICIDE TEBUTHIURON USING DSA (R)-TYPE ELECTRODE. Tebuthiuron (TBH) is a herbicide widely used in different cultures and known for its toxic effects. Electrochemical methods are promising for removing pollutants such as pesticides. This study showed the degradation of TBH using a DSA (R) anode operated at current densities of 50 to 200 mA cm(-2). Removal presented pseudo-first order kinetics while high-pressure liquid chromatography (UV detection) showed two peaks, ascribed to degradation intermediates. The maximum percentage of total organic carbon removed was 12.9%. Ion chromatography revealed that higher concentrations of nitrate and nitrite ions formed with increasing current density.
Resumo:
This qualitative study examines the social relationships between the Community Health Agents (CHAs) and the Family Health team (FH), highlighting cooperative interventions and interactions among workers. A total of 23 participant observations and 11 semi-structured interviews were conducted with an FH team in a city in the interior of Sao Paulo, Brazil. The results revealed that CHAs function as a link in the development of operational actions to expedite teamwork. These professionals, while creating bonds, articulate connections of teamwork and interact with other workers, developing common care plans and bringing the team and community together, as well as adapting care interventions to meet the real needs of people. In communication practice, when talking about themselves they talk about the community itself because they are the community's representatives and spokespersons on the team. The conclusion is that the CHA may be a strategic worker if his/her actions include more political and social dimensions of work in healthcare.
Resumo:
The main goal of this work was to develop a simple analytical method for quantification of glycerol based on the electrocatalytic oxidation of glycerol on the copper surface adapted in a flow injection system. Under optimal experimental conditions, the peak current response increases linearly with glycerol concentration over the range 60-3200 mg kg(-1) (equivalent to 3-160 mg L(-1) in solution). The repeatability of the electrode response in the flow injection analysis (FIA) configuration was evaluated as 5% (n = 10), and the detection limit of the method was estimated to be 5 mg kg(-1) in biodiesel (equivalent to 250 mu g L(-1) in solution) (S/N = 3). The sample throughput under optimised conditions was estimated to be 90 h(-1). Different types of biodiesel samples (B100), as in the types of vegetable oils or animal fats used to produce the fuels, were analysed (seven samples). The only sample pre-treatment used was an extraction of glycerol from the biodiesel sample containing a ratio of 5 mL of water to 250 mg of biodiesel. The proposed method improves the analytical parameters obtained by other electroanalytical methods for quantification of glycerol in biodiesel samples, and its accuracy was evaluated using a spike-and-recovery assay, where all the biodiesel samples used obtained admissible values according to the Association of Official Analytical Chemists. Crown Copyright (C) 2011 Published by Elsevier Ltd. All rights reserved.
Resumo:
The purposes of the study were to get to know conceptions on tuberculosis and health needs and to describe the care provided to people with tuberculosis, according to health professionals' perspective. Qualitative study developed at family health units in Capao Redondo, Sao Paulo. The data were collected through open interviews in January 2010 and submitted to discourse analysis, resulting in three categories: meanings attributed to tuberculosis and health needs and care characteristics. The conceptions regarding the disease are supported by the multi-causal theory of the health-disease process. The care is characterized by interventions that go beyond the biological dimension. The precarious living conditions define the needs of most people with tuberculosis, and can be more important to the ill than the very diagnosis of the disease, influencing treatment adherence, and should gain relevance in care.
Resumo:
A multiwall carbon nanotube/silicone rubber (MWCNT/SR) composite electrode has been used for the determination of hydrochlorothiazide (HCTZ) in pharmaceutical formulations by differential pulse voltammetry (DPV). The electro-oxidation process was evaluated by cyclic voltammetry, from which it was observed that HCTZ presents an irreversible oxidation peak at 0.82 V vs. saturated calomel electrode (SCE) in the potential range from 0.5 to 1.1 V, in Britton-Robinson buffer pH 7.0 at MWCNT/SR. HCTZ was determined by DPV using a MWCNT/SR 70% (MWCNT, m/m) composite electrode after the optimization of the experimental parameters. The linear range was from 5.0 to 70.0 mu mol L-1, with a limit of detection (LOD) of 2.6 mu mol L-1. The HCTZ was determined in pharmaceutical formulations using the proposed composite electrode and the results agreed with those from the official high performance liquid chromatography (HPLC) method within 95% confidence level, according to the t-Student test.