776 resultados para Engineering design -- Study and teaching (Higher)


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Due to the increasing demand for high power and reliable miniaturized energy storage devices, the development of micro-supercapacitors or electrochemical micro-capacitors have attracted much attention in recent years. This dissertation investigates several strategies to develop on-chip micro-supercapacitors with high power and energy density. Micro-supercapacitors based on interdigitated carbon micro-electrode arrays are fabricated through carbon microelectromechanical systems (C-MEMS) technique which is based on carbonization of patterned photoresist. To improve the capacitive behavior, electrochemical activation is performed on carbon micro-electrode arrays. The developed micro-supercapacitors show specific capacitances as high as 75 mFcm-2 at a scan rate of 5 mVs -1 after electrochemical activation for 30 minutes. The capacitance loss is less than 13% after 1000 cyclic voltammetry (CV) cycles. These results indicate that electrochemically activated C-MEMS micro-electrode arrays are promising candidates for on-chip electrochemical micro-capacitor applications. The energy density of micro-supercapacitors was further improved by conformal coating of polypyrrole (PPy) on C-MEMS structures. In these types of micro-devices the three dimensional (3D) carbon microstructures serve as current collectors for high energy density PPy electrodes. The electrochemical characterizations of these micro-supercapacitors show that they can deliver a specific capacitance of about 162.07 mFcm-2 and a specific power of 1.62mWcm -2 at a 20 mVs-1 scan rate. Addressing the need for high power micro-supercapacitors, the application of graphene as electrode materials for micro-supercapacitor was also investigated. The present study suggests a novel method to fabricate graphene-based micro-supercapacitors with thin film or in-plane interdigital electrodes. The fabricated micro-supercapacitors show exceptional frequency response and power handling performance and could effectively charge and discharge at rates as high as 50 Vs-1. CV measurements show that the specific capacitance of the micro-supercapacitor based on reduced graphene oxide and carbon nanotube composites is 6.1 mFcm -2 at scan rate of 0.01Vs-1. At a very high scan rate of 50 Vs-1, a specific capacitance of 2.8 mFcm-2 (stack capacitance of 3.1 Fcm-3) is recorded. This unprecedented performance can potentially broaden the future applications of micro-supercapacitors.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of this study was to find out the impact of field experience in hospitality education and whether such field experience and others such as semi-practicum, the cooperative, and the work study programs will not play an important role of a closer alliance between the academic and the hospitality industry. II. If it is justifiable to say that it is possible to provide field experience which will enhance the professionally oriented course work, while educators and employers strive to design curriculum that is needed to meet the educational and the industry demands and goals.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The inherent analogue nature of medical ultrasound signals in conjunction with the abundant merits provided by digital image acquisition, together with the increasing use of relatively simple front-end circuitries, have created considerable demand for single-bit  beamformers in digital ultrasound imaging systems. Furthermore, the increasing need to design lightweight ultrasound systems with low power consumption and low noise, provide ample justification for development and innovation in the use of single-bit  beamformers in ultrasound imaging systems. The overall aim of this research program is to investigate, establish, develop and confirm through a combination of theoretical analysis and detailed simulations, that utilize raw phantom data sets, suitable techniques for the design of simple-to-implement hardware efficient  digital ultrasound beamformers to address the requirements for 3D scanners with large channel counts, as well as portable and lightweight ultrasound scanners for point-of-care applications and intravascular imaging systems. In addition, the stability boundaries of higher-order High-Pass (HP) and Band-Pass (BP) Σ−Δ modulators for single- and dual- sinusoidal inputs are determined using quasi-linear modeling together with the describing-function method, to more accurately model the  modulator quantizer. The theoretical results are shown to be in good agreement with the simulation results for a variety of input amplitudes, bandwidths, and modulator orders. The proposed mathematical models of the quantizer will immensely help speed up the design of higher order HP and BP Σ−Δ modulators to be applicable for digital ultrasound beamformers. Finally, a user friendly design and performance evaluation tool for LP, BP and HP  modulators is developed. This toolbox, which uses various design methodologies and covers an assortment of  modulators topologies, is intended to accelerate the design process and evaluation of  modulators. This design tool is further developed to enable the design, analysis and evaluation of  beamformer structures including the noise analyses of the final B-scan images. Thus, this tool will allow researchers and practitioners to design and verify different reconstruction filters and analyze the results directly on the B-scan ultrasound images thereby saving considerable time and effort.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Ce travail évalue le comportement mécanique des matériaux cimentaires à différentes échelles de distance. Premièrement, les propriétés mécaniques du béton produit avec un bioplastifiant à base de microorganismes efficaces (EM) sont etudiées par nanoindentation statistique, et comparées aux propriétés mécaniques du béton produit avec un superplastifiant ordinaire (SP). Il est trouvé que l’ajout de bioplastifiant à base de produit EM améliore la résistance des C–S–H en augmentant la cohésion et la friction des nanograins solides. L’analyse statistique des résultats d’indentation suggère que le bioplastifiant à base de produit EM inhibe la précipitation des C–S–H avec une plus grande fraction volumique solide. Deuxièmement, un modèle multi-échelles à base micromécanique est dérivé pour le comportement poroélastique de la pâte de ciment au jeune age. L’approche proposée permet d’obtenir les propriétés poroélastiques requises pour la modélisation du comportoment mécanique partiellement saturé des pâtes de ciment viellissantes. Il est montré que ce modèle prédit le seuil de percolation et le module de Young non drainé de façon conforme aux données expérimentales. Un metamodèle stochastique est construit sur la base du chaos polynomial pour propager l’incertitude des paramètres du modèle à travers plusieurs échelles de distance. Une analyse de sensibilité est conduite par post-traitement du metamodèle pour des pâtes de ciment avec ratios d’eau sur ciment entre 0.35 et 0.70. Il est trouvé que l’incertitude sous-jacente des propriétés poroélastiques équivalentes est principalement due à l’énergie d’activation des aluminates de calcium au jeune age et, plus tard, au module élastique des silicates de calcium hydratés de basse densité.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction A computer-based simulation game (CSG) was used for the first time in a final-year undergraduate module. A change management simulation game was used in the seminar classes as a formative exercise that was linked to parts of the students’ summative assessment. The module evaluation suggests that most students learned from using the CSG.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Thesis (Ph.D.)--University of Washington, 2016-06

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Improving the transparency of information about the quality of health care providers is one way to improve health care quality. It is assumed that Internet information steers patients toward better-performing health care providers and will motivate providers to improve quality. However, the effect of public reporting on hospital quality is still small. One of the reasons is that users find it difficult to understand the formats in which information is presented. Objective: We analyzed the presentation of risk-adjusted mortality rate (RAMR) for coronary angiography in the 10 most commonly used German public report cards to analyze the impact of information presentation features on their comprehensibility. We wanted to determine which information presentation features were utilized, were preferred by users, led to better comprehension, and had similar effects to those reported in evidence-based recommendations described in the literature. Methods: The study consisted of 5 steps: (1) identification of best-practice evidence about the presentation of information on hospital report cards; (2) selection of a single risk-adjusted quality indicator; (3) selection of a sample of designs adopted by German public report cards; (4) identification of the information presentation elements used in public reporting initiatives in Germany; and (5) an online panel completed an online questionnaire that was conducted to determine if respondents were able to identify the hospital with the lowest RAMR and if respondents’ hospital choices were associated with particular information design elements. Results: Evidence-based recommendations were made relating to the following information presentation features relevant to report cards: evaluative table with symbols, tables without symbols, bar charts, bar charts without symbols, bar charts with symbols, symbols, evaluative word labels, highlighting, order of providers, high values to indicate good performance, explicit statements of whether high or low values indicate good performance, and incomplete data (“N/A” as a value). When investigating the RAMR in a sample of 10 hospitals’ report cards, 7 of these information presentation features were identified. Of these, 5 information presentation features improved comprehensibility in a manner reported previously in literature. Conclusions: To our knowledge, this is the first study to systematically analyze the most commonly used public reporting card designs used in Germany. Best-practice evidence identified in international literature was in agreement with 5 findings about German report card designs: (1) avoid tables without symbols, (2) include bar charts with symbols, (3) state explicitly whether high or low values indicate good performance or provide a “good quality” range, (4) avoid incomplete data (N/A given as a value), and (5) rank hospitals by performance. However, these findings are preliminary and should be subject of further evaluation. The implementation of 4 of these recommendations should not present insurmountable obstacles. However, ranking hospitals by performance may present substantial difficulties.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Graphene has emerged as an extraordinary material with its capability to accommodate an array of remarkable electronic, mechanical and chemical properties. Extra-large surface-to-volume ratio renders graphene a highly flexible morphology, giving rise to intriguing observations such as ripples, wrinkles and folds as well as the potential to transform into other novel carbon nanostructures. Ultra-thin, mechanically tough, electrically conductive graphene films promise to enable a wealth of possible applications ranging from hydrogen storage scaffolds, electronic transistors, to bottom-up material designs. Enthusiasm for graphene-based applications aside, there are still significant challenges to their realization, largely due to the difficulty of precisely controlling the graphene properties. Controlling the graphene morphology over large areas is crucial in enabling future graphene-based applications and material design. This dissertation aims to shed lights on potential mechanisms to actively manipulate the graphene morphology and properties and therefore enable the material design principle that delivers desirable mechanical and electronic functionalities of graphene and its derivatives.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

COMPASS is an experiment at CERN’s SPS whose goal is to study hadron structure and spectroscopy. The experiment includes a wide acceptance RICH detector, operating since 2001 and subject to a major upgrade of the central region of its photodetectors in 2006. The remaining 75% of the photodetection area are still using MWPCs from the original design, who suffer from limitations in gain due to aging of the photocathodes from ion bombardment and due to ion-induced instabilities. Besides the mentioned limitations, the increased luminosity conditions expected for the upcoming years of the experiment make an upgrade to the remaining detectors pertinent. This upgrade should be accomplished in 2016, using hybrid detectors composed of ThGEMs and MICROMEGAS. This work presents the study, development and characterization of gaseous photon detectors envisaging the foreseen upgrade, and the progress in production and evaluation techniques necessary to reach increasingly larger area detectors with the performances required. It includes reports on the studies performed under particle beam environment of such detectors. MPGD structures can also be used in a variety of other applications, of which nuclear medical imaging is a notorious example. This work includes, additionally, the initial steps in simulating, assembling and characterizing a prototype of a gaseous detector for application as a Compton Camera.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This dissertation presents work done in the design, modeling, and fabrication of magnetically actuated microrobot legs. Novel fabrication processes for manufacturing multi-material compliant mechanisms have been used to fabricate effective legged robots at both the meso and micro scales, where the meso scale refers to the transition between macro and micro scales. This work discusses the development of a novel mesoscale manufacturing process, Laser Cut Elastomer Refill (LaCER), for prototyping millimeter-scale multi-material compliant mechanisms with elastomer hinges. Additionally discussed is an extension of previous work on the development of a microscale manufacturing process for fabricating micrometer-sale multi-material compliant mechanisms with elastomer hinges, with the added contribution of a method for incorporating magnetic materials for mechanism actuation using externally applied fields. As both of the fabrication processes outlined make significant use of highly compliant elastomer hinges, a fast, accurate modeling method for these hinges was desired for mechanism characterization and design. An analytical model was developed for this purpose, making use of the pseudo rigid-body (PRB) model and extending its utility to hinges with significant stretch component, such as those fabricated from elastomer materials. This model includes 3 springs with stiffnesses relating to material stiffness and hinge geometry, with additional correction factors for aspects particular to common multi-material hinge geometry. This model has been verified against a finite element analysis model (FEA), which in turn was matched to experimental data on mesoscale hinges manufactured using LaCER. These modeling methods have additionally been verified against experimental data from microscale hinges manufactured using the Si/elastomer/magnetics MEMS process. The development of several mechanisms is also discussed: including a mesoscale LaCER-fabricated hexapedal millirobot capable of walking at 2.4 body lengths per second; prototyped mesoscale LaCER-fabricated underactuated legs with asymmetrical features for improved performance; 1 centimeter cubed LaCER-fabricated magnetically-actuated hexapods which use the best-performing underactuated leg design to locomote at up to 10.6 body lengths per second; five microfabricated magnetically actuated single-hinge mechanisms; a 14-hinge, 11-link microfabricated gripper mechanism; a microfabricated robot leg mechansim demonstrated clearing a step height of 100 micrometers; and a 4 mm x 4 mm x 5 mm, 25 mg microfabricated magnetically-actuated hexapod, demonstrated walking at up to 2.25 body lengths per second.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Local anesthetic agents cause temporary blockade of nerve impulses productiong insensitivity to painful stimuli in the area supplied by that nerve. Bupivacaine (BVC) is an amide-type local anesthetic widely used in surgery and obstetrics for sustained peripheral and central nerve blockade. in this study, we prepared and characterized nanosphere formulations containing BVC. To achieve these goals, BVC loaded poly(DL-lactide-co-glycolide) (PLGA) nanospheres (NS) were prepared by nanopreciptation and characterized with regard to size distribution, drug loading and cytotoxicity assays. The 2(3-1) factorial experimental design was used to study the influence of three different independent variables on nanoparticle drug loading. BVC was assayed by HPLC, the particle size and zeta potential were determined by dynamic light scattering. BVC was determined using a combined ultrafiltration-centrifugation technique. The results of optimized formulations showed a narrow size distribution with a polydispersivity of 0.05%, an average diameter of 236.7 +/- 2.6 nm and the zeta potential -2.93 +/- 1,10 mV. In toxicity studies with fibroblast 3T3 cells, BVC loaded-PLGA-NS increased cell viability, in comparison with the effect produced by free BVC. In this way, BVC-loaded PLGA-NS decreased BVC toxicity. The development of BVC formulations in carriers such as nanospheres could offer the possibility of controlling drug delivery in biological systems, prolonging the anesthetic effect and reducing toxicity.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To design and develop a new series of histone deacetylase inhibitors (FP1 - FP12) and evaluate their inhibitory activity against hydroxyacetamide (HDAC) enzyme mixture-derived HeLa cervical carcinoma cell and MCF-7. Methods: The designed molecules (FP1 - FP12) were docked using AUTODOCK 1.4.6. FP3 and FP8 showed higher interaction comparable to the prototypical HDACI. The designed series of 2-[[(3- Phenyl/substituted Phenyl-[4-{(4-(substituted phenyl)ethylidine-2-Phenyl-1,3-Imidazol-5-One}](-4H- 1,2,4-triazol-5-yl)sulfanyl]-N-hydroxyacetamide derivatives (FP1-FP12) was synthesized by merging 2- [(4-amino-3-phenyl-4H- 1, 2, 4-triazol-5-yl) sulfanyl]-N-hydroxyacetamide and 2-{[4-amino-3-(2- hydroxyphenyl)-4H-1,2, 4-triazol-5-yl]sulfanyl}-N hydroxyacetamide derivatives with aromatic substituted oxazolone. The biological activity of the synthesized molecule (FP1-FP12) was evaluated against HDAC enzyme mixture-derived HeLa cervical carcinoma cell and breast cancer cell line (MCF-7). Results: HDAC inhibitory activity of FP10 showed higher IC50 (half-maximal concentration inhibitory activity) of 0.09 μM, whereas standard SAHA molecule showed IC50 of 0.057 μM. On the other hand, FP9 exhibited higher GI50 (50 % of maximal concentration that inhibited cell proliferation) of 22.8 μM against MCF-7 cell line, compared with the standard, adriamycin, with GI50 of (-) 50.2 μM. Conclusion: Synthesis, spectral characterization, and evaluation of HDAC inhibition activity and in vitro anticancer evaluation of novel hydroxyacetamide derivatives against MCF-7 cell line have been achieved. The findings indicate the emergence of potentialanticancer compounds.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

En CAD/CAGC/CG la organización topológica de datos de formas geométricas presenta dificultades: (i) las características matemáticas de la superficie dependen de la consideraciones no geométricas, (ii) los datos presentan una aleatoriedad por efectos del muestreo, y, (iii) una digitalización xyz incluye en general varias direcciones e intervalos de muestreo -- En consecuencia, esta investigación presenta herramientas (portables a diferentes servidores CAD) para la organización topológica de datos de digitalizaciones y un caso de recuperación de formas óseas -- En los dos casos los resultado obtenidos rompen la combinación cerrada hardware - software propietarios tradicionales, con la consecuente reducción en costos de tecnología