939 resultados para Adsorption Measurements


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The adsorption kinetics and equilibrium of methylene blue (MB) onto reticulated formic lignin (RFL) from sugar cane bagasse was studied. The adsorption process is pH, temperature and ionic strength (µ) dependent and obeys the Langmuir model. Conditions for higher adsorption rate and capacity were determined. The faster adsorption (12 hours) and higher adsorption capacity (34.20 mg.g-1) were observed at pH = 5.8 (acetic acid-sodium acetate aqueous buffer), 50 ºC and 0.1 ionic strength. Under temperature (50 ºC) control and occasional mechanical stirring it took from 1 to 10 days to reach the equilibrium.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In general, the traditional Physics courses needs examples of the aplications of the Physics concepts in other areas such as Chemistry and Biology. This lacks tend to demotivate Chemistry and Biology students regarding to deal with Physical concepts developed in classroom. In this work, the analogy among mechanic and electric oscillators is investigated to be applied in Chemistry and Biology areas, showing to be valuable due to its aplication in techniques that aims to measure mass variation with high precision. This measure could be made in a direct or indirect way. These techniques are known as electrogravimetric techniques and they are important in biosensor aplications. Thus, this paper explores the electromechanic analogy in an interdisciplinary way involving areas like Physics, Chemistry and Biology. Based on this analogy, it is proposed an experiment that can be applied in different ways, i.e. by an basic approach or more deeper, depending on the students specific formation, in other words, Physics, Chemistry or Biology.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Groundwater from nine wells of three different districts, located at Sana'a secretariat was analyzed for hydrochemical quality assessment. Measurements of water quality parameters including pH, EC, CO3(2-), HCO3-, Cl-, NO3-, SO4(2-), Ca2+, Mg2+, Fe3+, K+, and Na+ were carried out . Classification of the groundwater samples according to Cl, SO4(2-), CO3(2-) and HCO3-, hardness (H), total dissolved solids (TDS), base-exchange, and meteoric genesis was demonstrated. Suitability of ground water samples for irrigation and industrial uses according to sodium adsorption ration (SAR), ratio of dissolved sodium (RDS), residual sodium carbonate (RSC) and saturation index (SI) was also investigated. The results of this study showed that almost all ground water samples were of good quality that makes them suitable for drinking and domestic uses. Results also indicated that even though some of the ground water samples were suitable for irrigation purposes, almost all of them were found not be good for industrial uses. Despite all drawbacks of the sewerage system built around Sana'a secretariat at the beginning of the first decade of the third millennium, the results of this study indicate that there is scope of significant improvement in Sana'a secretariat ground water quality.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Palm oil is one of the two most important vegetable oils in the world's oil and fats market. The extraction and purification processes generate different kinds of waste generally known as palm oil mill effluent (POME). Earlier studies had indicated the possibility of using boiler fly ash to adsorb impurities and colour in POME treatment. The adsorption treatment of POME using boiler fly ash was further investigated in detail in this work with regards to the reduction of BOD, colour and TSS from palm oil mill effluent. The amount of BOD, colour and TSS adsorbed increased as the weight of the boiler fly ash used was increased. Also, the smaller particle size of 425µm adsorbed more than the 850µm size. Attempts were made to fit the experimental data with the Freundlich, Langmuir and Dubinin-Radushkevich isotherms. The R² values, which ranged from 0.8974-0.9898, 0.8848-0.9824 and 0.6235-0.9101 for Freundlich, Langmuir and Dubinin-Radushkevich isotherms respectively, showed that Freundlich isotherm gave a better fit followed by Langmuir and then Dubinin-Radushkevich isotherm. The sorption trend could be put as BOD > Colour > TSS. The apparent energy of adsorption was found to be 1.25, 0.58 and 0.97 (KJ/mol) for BOD, colour and TSS respectively, showing that sorption process occurs by physiosorption. Therefore, boiler fly ash is capable of reducing BOD, Colour and TSS from POME and hence could be used to develop a good adsorbent for POME treatment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

There are several filtration applications in the pulp and paper industry where the capacity and cost-effectiveness of processes are of importance. Ultrafiltration is used to clean process water. Ultrafiltration is a membrane process that separates a certain component or compound from a liquid stream. The pressure difference across the membrane sieves macromolecules smaller than 0.001-0.02 μm through the membrane. When optimizing the filtration process capacity, online information about the conditions of the membrane is needed. Fouling and compaction of the membrane both affect the capacity of the filtration process. In fouling a “cake” layer starts to build on the surface of the membrane. This layer blocks the molecules from sieving through the membrane thereby decreasing the yield of the process. In compaction of the membrane the structure is flattened out because of the high pressure applied. The higher pressure increases the capacity but may damage the structure of the membrane permanently. Information about the compaction is needed to effectively operate the filters. The objective of this study was to develop an accurate system for online monitoring of the condition of the membrane using ultrasound reflectometry. Measurements of ultrafiltration membrane compaction were made successfully utilizing ultrasound. The results were confirmed by permeate flux decline, measurements of compaction with a micrometer, mechanical compaction using a hydraulic piston and a scanning electron microscope (SEM). The scientific contribution of this thesis is to introduce a secondary ultrasound transducer to determine the speed of sound in the fluid used. The speed of sound is highly dependent on the temperature and pressure used in the filters. When the exact speed of sound is obtained by the reference transducer, the effect of temperature and pressure is eliminated. This speed is then used to calculate the distances with a higher accuracy. As the accuracy or the resolution of the ultrasound measurement is increased, the method can be applied to a higher amount of applications especially for processes where fouling layers are thinner because of smaller macromolecules. With the help of the transducer, membrane compaction of 13 μm was measured in the pressure of 5 bars. The results were verified with the permeate flux decline, which indicated that compaction had taken place. The measurements of compaction with a micrometer showed compaction of 23–26 μm. The results are in the same range and confirm the compaction. Mechanical compaction measurements were made using a hydraulic piston, and the result was the same 13 μm as obtained by applying the ultrasound time domain reflectometry (UTDR). A scanning electron microscope (SEM) was used to study the structure of the samples before and after the compaction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this thesis, general approach is devised to model electrolyte sorption from aqueous solutions on solid materials. Electrolyte sorption is often considered as unwanted phenomenon in ion exchange and its potential as an independent separation method has not been fully explored. The solid sorbents studied here are porous and non-porous organic or inorganic materials with or without specific functional groups attached on the solid matrix. Accordingly, the sorption mechanisms include physical adsorption, chemisorption on the functional groups and partition restricted by electrostatic or steric factors. The model is tested in four Cases Studies dealing with chelating adsorption of transition metal mixtures, physical adsorption of metal and metalloid complexes from chloride solutions, size exclusion of electrolytes in nano-porous materials and electrolyte exclusion of electrolyte/non-electrolyte mixtures. The model parameters are estimated using experimental data from equilibrium and batch kinetic measurements, and they are used to simulate actual single-column fixed-bed separations. Phase equilibrium between the solution and solid phases is described using thermodynamic Gibbs-Donnan model and various adsorption models depending on the properties of the sorbent. The 3-dimensional thermodynamic approach is used for volume sorption in gel-type ion exchangers and in nano-porous adsorbents, and satisfactory correlation is obtained provided that both mixing and exclusion effects are adequately taken into account. 2-Dimensional surface adsorption models are successfully applied to physical adsorption of complex species and to chelating adsorption of transition metal salts. In the latter case, comparison is also made with complex formation models. Results of the mass transport studies show that uptake rates even in a competitive high-affinity system can be described by constant diffusion coefficients, when the adsorbent structure and the phase equilibrium conditions are adequately included in the model. Furthermore, a simplified solution based on the linear driving force approximation and the shrinking-core model is developed for very non-linear adsorption systems. In each Case Study, the actual separation is carried out batch-wise in fixed-beds and the experimental data are simulated/correlated using the parameters derived from equilibrium and kinetic data. Good agreement between the calculated and experimental break-through curves is usually obtained indicating that the proposed approach is useful in systems, which at first sight are very different. For example, the important improvement in copper separation from concentrated zinc sulfate solution at elevated temperatures can be correctly predicted by the model. In some cases, however, re-adjustment of model parameters is needed due to e.g. high solution viscosity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tässä diplomityössä tutkittiin kalvosuodatuksen ja adsorption yhdistämistä biojalostamon erotusprosesseissa. Työn kirjallisuusosassa käsitellään hemiselluloosien erottamista puusta, kalvosuodatusta hemiselluloosien käsittelyssä sekä hemiselluloosien pilkkomista sokereiksi ja sokereiden kromatografista erotusta. Kokeellisessa osassa tutkittiin hemiselluloosahydrolysaatin fraktioimista kalvosuodatuksella ja adsorbenttikäsittelyn vaikutusta hydrolysaatin suodatettavuuteen. Kokeellisessa osassa tutkittiin myös fraktioinnin vaikutusta hartsien likaantumiseen happohydrolyysin jälkeisessä kromatografisessa erotuksessa. Työssä kokeiltiin useita erilaisia kalvoja, mutta suurin osa suodatuksista tehtiin regeneroidusta selluloosasta valmistetulla kalvolla UC030 ja polyeetterisulfoni kalvolla UFX5. Esikäsittelyyn käytettiin XAD16 adsorbenttia ja hartsien likaantumista tutkittiin CS12GC Na+ hartsilla. Suodatuskokeet tehtiin sekä laboratoriomittakaavan Amicon-suodattimella että pilot-mittakaavan CR- suodattimella. Työn tulokset osoittivat, että konsentroituneen hemiselluloosafraktion tuottaminen tehokkaasti ei onnistu kalvosuodatuksella ilman esikäsittelyä. Kalvon likaantumisen vuoksi permeaattivuo laski hyvin nopeasti niin alhaiseksi, ettei suodatuksen jatkaminen olisi taloudellisesti kannattavaa. Hydrolysaatin esikäsittely XAD16 adsorbentillä poisti tehokkaasti kalvoja likaavia uuteaineita ja ligniiniä. Adsorbenttikäsittelyn jälkeen hydrolysaatin suodattaminen onnistui ilman permeaattivuon huomattavaa alenemista toisessa suodatusvaiheessa ja saatiin aikaiseksi hyvin konsentroitunut hemiselluloosafraktio.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a new approach in tomographic instrumentation for agriculture based on Compton scattering, which allows for the simultaneous measurements of density and moisture of soil samples. Compton tomography is a technique that can be used to obtain a spatial map of electronic density of samples. Quantitative results can be obtained by using a reconstruction algorithm that takes into account the absorption of incident and scattered radiation. Results show a coefficient of linear correlation better than 0.81, when comparison is made between soil density measurements based on this method and direct transmission tomography. For soil water contents, a coefficient of linear correlation better than 0.79 was found when compared with measurements obtained by time domain reflectrometry (TDR). In addition, a set of Compton scatter images are presented to illustrate the efficacy of this imaging technique, which makes possible improved spatial variability analysis of pre-established planes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The offset printing process is complex and involves the meeting of two essentially complex materials, printing ink and paper, upon which the final product is formed. It can therefore be expected that a multitude of chemical and physical interactions and mechanisms take place at the ink-paper interface. Interactions between ink and paper are of interest to both the papermakers and ink producers, as they wish to achieve better quality in the final product. The objective of this work is to clarify the combined influence of paper coating structure, printing ink and fountain solution on ink setting and the problems related to ink setting. A further aim is to identify the mechanisms that influence ink setting problems, and to be able to counteract them by changing properties of the coating layer or by changing the properties of the ink. The work carried out for this thesis included use of many techniques ranging from standard paper and printability tests to advanced optical techniques for detection of ink filaments during ink levelling. Modern imaging methods were applied for assessment of ink filament remain sizes and distribution of ink components inside pigment coating layers. Gravimetric filtration method and assessment of print rub using Ink-Surface-Interaction-Tester (ISIT) were utilized to study the influence of ink properties on ink setting. The chemical interactions were observed with the help of modified thin layer chromatography and contact angle measurements using both conventional and high speed imaging. The results of the papers in this thesis link the press operational parameters to filament sizes and show the influence of these parameters to filament size distribution. The relative importance between the press operation parameters was shown to vary. The size distribution of filaments is important in predicting the ink setting behaviour, which was highlighted by the dynamic gloss and ink setting studies. Prediction of ink setting behaviour was also further improved by use of separate permeability factors for different ink types in connection to filtration equations. The roles of ink components were studied in connection to ink absorption and mechanism of print rub. Total solids content and ratio of linseed oil to mineral oil were found to determine the degree of print rub on coated papers. Wax addition improved print rub resistance, but would not decrease print rub as much as lowering the total solids content in the ink. Linseed oil was shown to absorb into pigment coating pores by mechanism of adsorption to pore walls, which highlights the need for sufficient pore surface area for improved chromatographic separation of ink components. These results should help press operators, suppliers of printing presses, papermakers and suppliers to papermakers, to better understand the material and operating conditions of the press as it relates to various print quality issues. Even though paper is in competition with electronic media, high quality printed products are still in demand. The results should provide useful information for this segment of the industry.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Resonance energy transfer (RET) is a non-radiative transfer of the excitation energy from the initially excited luminescent donor to an acceptor. The requirements for the resonance energy transfer are: i) the spectral overlap between the donor emission spectrum and the acceptor absorption spectrum, ii) the close proximity of the donor and the acceptor, and iii) the suitable relative orientations of the donor emission and the acceptor absorption transition dipoles. As a result of the RET process the donor luminescence intensity and the donor lifetime are decreased. If the acceptor is luminescent, a sensitized acceptor emission appears. The rate of RET depends strongly on the donor–acceptor distance (r) and is inversely proportional to r6. The distance dependence of RET is utilized in binding assays. The proximity requirement and the selective detection of the RET-modified emission signal allow homogeneous separation free assays. The term lanthanide-based RET is used when luminescent lanthanide compounds are used as donors. The long luminescence lifetimes, the large Stokes’ shifts and the intense, sharply-spiked emission spectra of the lanthanide donors offer advantages over the conventional organic donor molecules. Both the organic lanthanide chelates and the inorganic up-converting phosphor (UCP) particles have been used as donor labels in the RET based binding assays. In the present work lanthanide luminescence and lanthanide-based resonance energy transfer phenomena were studied. Luminescence lifetime measurements had an essential role in the research. Modular frequency-domain and time-domain luminometers were assembled and used successfully in the lifetime measurements. The frequency-domain luminometer operated in the low frequency domain ( 100 kHz) and utilized a novel dual-phase lock-in detection of the luminescence. One of the studied phenomena was the recently discovered non-overlapping fluorescence resonance energy transfer (nFRET). The studied properties were the distance and temperature dependences of nFRET. The distance dependence was found to deviate from the Förster theory and a clear temperature dependence was observed whereas conventional RET was completely independent of the temperature. Based on the experimental results two thermally activated mechanisms were proposed for the nFRET process. The work with the UCP particles involved the measurement of the luminescence properties of the UCP particles synthesized in our laboratory. The goal of the UCP particle research is to develop UCP donor labels for binding assays. In the present work the effect of the dopant concentrations and the core–shell structure on the total up-conversion luminescence intensity, the red–green emission ratio, and the luminescence lifetime was studied. Also the non-radiative nature of the energy transfer from the UCP particle donors to organic acceptors was demonstrated for the first time in aqueous environment and with a controlled donor–acceptor distance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Att övervaka förekomsten av giftiga komponenter i naturliga vattendrag är nödvändigt för människans välmående. Eftersom halten av föroreningar i naturens ekosystem bör hållas möjligast låg, pågår en ständig jakt efter kemiska analysmetoder med allt lägre detektionsgränser. I dagens läge görs miljöanalyser med dyr och sofistikerad instrumentering som kräver mycket underhåll. Jonselektiva elektroder har flera goda egenskaper som t.ex. bärbarhet, låg energiförbrukning, och dessutom är de relativt kostnadseffektiva. Att använda jonselektiva elektroder vid miljöanalyser är möjligt om deras känslighetsområde kan utvidgas genom att sänka deras detektionsgränser. För att sänka detektionsgränsen för Pb(II)-selektiva elektroder undersöktes olika typer av jonselektiva membran som baserades på polyakrylat-kopolymerer, PVC och PbS/Ag2S. Fast-fas elektroder med membran av PbS/Ag2S är i allmänhet enklare och mer robusta än konventionella elektroder vid spårämnesanalys av joniska föroreningar. Fast-fas elektrodernas detektionsgräns sänktes i detta arbete med en nyutvecklad galvanostatisk polariseringsmetod och de kunde sedan framgångsrikt användas för kvantitativa bestämningar av bly(II)-halter i miljöprov som hade samlats in i den finska skärgården nära tidigare industriområden. Analysresultaten som erhölls med jonselektiva elektroder bekräftades med andra analytiska metoder. Att sänka detektionsgränsen m.hj.a. den nyutvecklade polariseringsmetoden möjliggör bestämning av låga och ultra-låga blyhalter som inte kunde nås med klassisk potentiometri. Den verkliga fördelen med att använda dessa blyselektiva elektroder är möjligheten att utföra mätningar i obehandlade miljöprov trots närvaron av fasta partiklar vilket inte är möjligt att göra med andra analysmetoder. Jag väntar mig att den nyutvecklade polariseringsmetoden kommer att sätta en trend i spårämnesanalys med jonselektiva elektroder.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work parameters of Mg-doped GaN samples were studied using positron annihilation spectroscopy and analyzed. It is shown that gallium vacancies exist in an unintentionally doped sample. Next, the sample with higher concentration of Mg and low growth temperature contains vacancy clusters. In case of low concentration of Mg the growth temperature does not affect the formation of defects. Analog electronics can be replaced by a modern digital device. While promising a high quantity of benefits, the performance of these digitizers requires thorough adjustment. A 14-bit two channel digitizer has been tested in order to achieve better performance than the one of a traditional analog setup, and the adjustment process is described. It has been shown that the digital device is unable to achieve better energy resolution, but it is quite close to the corresponding attribute of the available analog system, which had been used for measurements in Mg-doped GaN.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This thesis addresses the use of covariant phase space observables in quantum tomography. Necessary and sufficient conditions for the informational completeness of covariant phase space observables are proved, and some state reconstruction formulae are derived. Different measurement schemes for measuring phase space observables are considered. Special emphasis is given to the quantum optical eight-port homodyne detection scheme and, in particular, on the effect of non-unit detector efficiencies on the measured observable. It is shown that the informational completeness of the observable does not depend on the efficiencies. As a related problem, the possibility of reconstructing the position and momentum distributions from the marginal statistics of a phase space observable is considered. It is shown that informational completeness for the phase space observable is neither necessary nor sufficient for this procedure. Two methods for determining the distributions from the marginal statistics are presented. Finally, two alternative methods for determining the state are considered. Some of their shortcomings when compared to the phase space method are discussed.