Resumo:
A simple and reliable ashing procedure is proposed for the preparation of used lubricating oil samples for the determination of Zn, Fe, Pb, Ni and Cu by the flame atomic absorption spectrometry technique. Sulphanilic acid was added to oil samples, the mixture coked and the coke ashed at 550 ºC. The solutions of the ash were analysed by flame AAS for these metals. The quantification limits were 38.250 µg g-1 for Zn, 4.550 µg g-1 for Fe, 1.562 µg g-1 for Pb, 1.450 µg g-1 for Ni, and 0.439 µg g-1 for Cu. The determinations, in lubricating oil, showed good precision and accuracy with recoveries between 90 and 110 %, indicating a negligible matrix effect in the experiments using addition of analyte, with relative standard deviation lower than 5%. The results for analysis of wastewater contamined by theses lubricants showed a very high relative standard deviation.
Resumo:
In terms of soil fertility, zinc is a micronutrient that is very important in the culture of soy, maize, rice and coffee, because it is a structural and functional component of a great number of enzymes. Therefore, diverse methods have been used to determine zinc in soil. In this work we use colorimetry as a methods of zinc determination in soil using two methodologies of sample digesting, H2SO4/H2O2 and HNO3/H2O2. In order to compare the results, atomic absorption spectrometry (AAS) was used. Results show that colorimetric methods can be used due to good sensitivity and reproducibility, since the zinc calibration curve showed good linearity. Comparing colorimetric methods with AAS we observed that the results were equivalent, as proven by the statistical values of the F and t of Student tests. Furthermore, both methods of soil digesting can be used, leading to a flexible methodology of low-cost for routine zinc analyses in soil.
Resumo:
The spatial and temporal retention of metals has been studied in water and sediments of the Gavião River, Anagé and Tremedal Reservoirs, located in the semi-arid region, Bahia - Brazil, in order to identify trends in the fluxes of metals from the sediments to the water column. The determination of metals was made by ICP OES and ET AAS. The application of statistical methods showed that this aquatic system presents suitable conditions to move Cd2+ and Pb2+ from the water column to the sediment.
Resumo:
This work reports an alternative, fast and robust method, for the determination of total As, As(III) and As(V) by HG-AAS without the use of prereductants. The method is based on the different rates of arsine formation of the inorganic As species and the effect of As(III) in the signal obtained for total As. Groundwater and mineral spiked waters were used to sample preservation evaluation. The method was validated by the determination of As in SRM 1640 and used in the determination of total As and its inorganic species in groundwater samples collected from mines in the Iron Quadrangle - MG.
Resumo:
A new mixed material was obtained through the combination of the suspensions of iron oxy-hydroxide and bentonite clay, denoted BFe. Analysis of its structure (XRD, Mossbauer and TGA) and composition (AAS) suggests the maintenance of the layer structure of the clay and an increase in the thermal stability of the BFe. Electrochemical studies performed in different electrolytes show that only in an alkaline medium it is possible to observe the redox peaks relative to the processes involving Fe+2/Fe+3 pair. Tests that evaluated the potential use of the photo-Fenton process showed an efficient degradation process of the dyes in significantly reduced reaction times.
Resumo:
Jundiaí river is the main stream in the Jundiaí Hydrographic Basin and its water is not considered safe for public supply. The water problem is getting worse with the development of the region. The Pirai stream, have been one of the last potable water resource. With the purpose of investigating the sediment quality, due to its influence on the water quality, bioavailable and total Cd and Pb were determined using TS-FF-AAS. Total Cd and Pb up to 2.47 and 24.7 µg g-1 were measured, respectively. The wastewater sludge showed concentrations of 4.01 and 171 µg g-1, for the same metals.
Resumo:
A flow injection on-line pre-concentration system coupled to thermospray flame furnace atomic absorption spectrometry (TS-FF-AAS) for cadmium determination at sub μg L-1 levels in seawater samples was developed. The on-line system was evaluated by analysing cadmium containing in a synthetic seawater matrix (2.5% m/v NaCl, 0.5% m/v MgCl2 and 0.8% m/v CaCl2). A sample volume of 2 mL allows determining Cd with a detection limits of 30 ng L-1 (3* σblank/slope), pre-concentration factor of 34 and repeatability of 1,8% (calculated as RSD, N=8 and containing 200 ng L-1 of Cd ).
Resumo:
A simple flow system with multiple pulse amperometric detection using a single working electrode is proposed for simultaneous determination of ascorbic (AA) and acetylsalicylic (AAS) acids in pharmaceutical formulations. The procedure is based on application of two potential pulses: 0.90 V/50 ms: oxidation and determination of AA without the interference of AAS; 1.35 V/50 ms: oxidation of both compounds and quantification of AAS by current subtraction using a correction factor. Sampling rate was estimated as 125 injections per hour and the limits of detection were 0.17 and 0.16 µmol L-1 for AA and AAS, respectively. Results for commercial samples agreed with those obtained using HPLC.
Resumo:
The metal distribution in the surface sediment fractions of the Cachoeira River was evaluated based on the fractionation method using a five-step sequential extraction. The determination of metals was made by flame atomic absorption spectrophotometry (F AAS). Zn, Pb and Cu exhibit higher concentrations in the residual fraction of the sediment from sites that receive discharges from urban and industrial zones. High levels of Ni (60 ± 1 to 447 ± 9 µg L-1) were found in the river water, which may be detrimental to the "health" of rural communities that utilize the river water for domestic purposes without treatment.
Resumo:
In this study, a method for determination of hexavalent chromium in aqueous samples using liquid-liquid microextraction (LLME) and detection by Flame Atomic Absorption Spectrometry (F AAS) was developed. The LLME procedure was based on the extraction of Cr (VI) by acetone at a sample pH of 1.2. The use of saturated ammonium sulphate solution allowed effective separation of the aqueous and organic phases and acetone extracted chromium. The sample pH, acetone volume and stirring time were optimized by a full factorial design.
Resumo:
Diplomityössä tutkittiin kromatografian, elektroforeesin ja spektrometrian käyttöä ympäristövesianalytiikassa. Kokeellisessa osassa analysoitiin Saimaan Vesi- ja Ympäristötutkimus Oy:n keräämistä kaatopaikka-, jätevesi-, pohjavesi-, vesistö-, uimahalli-, yksityiskaivo-, poreallas- ja suovesinäytteistä epäorgaaniset anionit (F-, Cl-, Br-, NO3-, NO2- SO42-ja PO42-) sekä ionikromatografilla että kapillaarielektroforeesilla. Näytteet on kerätty Saimaan alueen ympäristökunnista. Kapillaarielektroforeesilla analysoitiin lisäksi tiosulfaatti. Liekkiatomiabsorptio-spektrometrilla analysoitiin Cu, Fe, Na ja Al. Natriumia löytyi jokaisesta vesinäytteestä. Pohjavesistä ei löytynyt rautaa eikä alumiinia ja kuparipitoisuudet olivat alle määritysrajan. Vesistövesistä kahdessa näytteessä oli alle määritysrajan olevia rautapitoisuuksia. Muissa näytteissä ei rautaa ollut. Suovesistä kuparia löytyi hyvin pieniä määriä ja yhdestä näytteestä alumiinia alle määritysrajan. Kaatopaikkavesissä kuparipitoisuudet sekä kolmessa näytteessä alumiinipitoisuudet olivat alle määritysrajan. Jätevesistä oletettiin löytyvän suuria määriä typpispesieksiä ja fosforia. Niitä kuitenkin esiintyi isoissa pitoisuuksissa vain suovesinäytteissä. Jätevesinäytteet sisälsivät bromidia, nitraattia ja fluoridia jopa yli 140 mg/l. Kapillaarielektroforeesilla ja ionikromatografilla mitatut anionipitoisuudet korreloivat hyvin toisiaan. Kontaminoituja vesiä löytyi pohja-, kaatopaikka-, jäte- ja vesistövesistä sekä uima-altaan terapiaaltaan vedestä.
Resumo:
The determination of the total calcium in juice, syrups, and other products of the sugar industry is investigated. Total calcium and free calcium is determinated by AAS and employing Ca-selective electrode respectively. A coefficient is obtained for the relation of total calcium with respect to free calcium. The coefficient is employed to determine the content of total calcium in accordance with the following equation.
Resumo:
Este trabalho descreve uma revisão a respeito do uso do ligante dietilditiofosfato de amônio em química analítica e suas potencialidades no campo da análise química espectrofotométrica (UV/VIS) e espectrométrica (AAS, ICP-AES, ICP-MS) em diferentes matrizes e meios. A discriminação de espécies químicas por meio de complexações seletivas de elementos químicos com dietilditiofosfato e a hifenação de técnicas espectroscópicas a etapas de separação como extração em fase sólida, extração líquido-líquido, extração por "cloud point", são outros assuntos abordados neste trabalho.
Resumo:
Silica gel chemically modified with 2-Aminotiazole groups, abbreviated as SiAT, was used for preconcentration of copper, zinc, nickel and iron from kerosene, normally used as a engine fuel for airplanes. Surface characteristics and surface area of the silica gel were obtained before and after chemical modification using FT-IR, Kjeldhal and surface area analysis (B.E.T.). The retention and recovery of the analyte elements were studied by applying batch and column techniques. The experimental parameters, such as shaking time in batch technique, flow rate and concentration of the eluent (HCl- 0.25-2.00 mol L-1) and the amount of silica, on retention and elution, have been investigated. Detection limits of the method for copper, iron, nickel and zinc are 0.77, 2.92, 1.73 and 0.097 mg L-1, respectively. The sorption-desorption of the studied metal ions made possible the development of a preconcentration method for metal ions at trace level in kerosene using flame AAS for their quantification.
Use of modified silica gel for concentrating Pb (II) and Cd (II) occurring in form of complex anions
Resumo:
The performance of silica gel, modified by the impregnation with a high molecular weight quaternary amine (triethyl octadecyl ammonium iodide), used for the concentration of heavy metals occurring in water is studied. The material under study captures Cd, Pb, which are capable of forming stable complexes with I- ions.The results obtained about the metal capture, under dynamic conditions, are described and metal ions are removed by desorption with EDTA and quantified by AAS.