A new flow procedure based on multicommutation with chemiluminometric detection was developed to quantify gentamicin sulphate in pharmaceutical formulations. This approach is based on gentamicin's ability to inhibit the chemiluminometric reaction between luminol and hypochlorite in alkaline medium, causing a decrease in the analytical signal. The inhibition of the analytical signal is proportional to the concentration of gentamicin sulphate, within a linear range of 1 to 4 mu g mL(-1) with a coefficient variation <3%. A sample throughput of 55 samples h(-1) was obtained. The developed method is sensitive, simple, with low reagent consumption, reproducible, and inexpensive, and when applied to the analysis of pharmaceutical formulations (eye drops and injections) it gave results with RSD between 1.10 and 4.40%.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose Among environmental factors governing innumerous processes that are active in estuarine environments, those of edaphic character have received special attention in recent studies. With the objectives of determining the spatial patterns of soil attributes and components across different mangrove forest landscapes and obtaining additional information on the cause-effect relationships between these variables and position within the estuary, we analyzed several soil attributes in 31 mangrove soil profiles from the state of So Paulo (Guaruja, Brazil). Materials and methods Soil samples were collected at low tide along two transects within the CrumahA(0) mangrove forest. Samples were analyzed to determine pH, Eh, salinity, and the percentages of sand, silt, clay, total organic carbon (TOC), and total S. Mineralogy of the clay fraction (< 2 mm) was also studied by X-ray diffraction analysis, and partitioning of solid-phase Fe was performed by sequential extraction. Results and discussion The results obtained indicate important differences in soil composition at different depths and landscape positions, causing variations in physicochemical parameters, clay mineralogy, TOC contents, and iron geochemistry. The results also indicate that physicochemical conditions may vary in terms of different local microtopographies. Soil salinity was determined by relative position in relation to flood tide and transition areas with highlands. The proportions of TOC and total S are conditioned by the sedimentation of organic matter derived from vegetation and by the prevailing redox conditions, which clearly favored intense sulfate reduction in the soils (similar to 80% of the total Fe is Fe-pyrite). Particle-size distribution is conditioned by erosive/deposition processes (present and past) and probably by the positioning of ancient and reworked sandy ridges. The existing physicochemical conditions appear to contribute to the synthesis (smectite) and transformation (kaolinite) of clay minerals. Conclusions The results demonstrate that the position of soils in the estuary greatly affects soil attributes. Differences occur even at small scales (meters), indicating that both edaphic (soil classification, soil mineralogy, and soil genesis) and environmental (contamination and carbon stock) studies should take such variability into account.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The extensive use of antineoplastic agents in chemotherapy may be at risk to health care workers involved in the preparation and administration of these drugs. In this study cyclophosphamide, a drug classified as a human carcinogen, was quantified by adapting a previous analytical method using gas chromatography coupled to mass spectrometry (GC-MS) after solid phase extraction with diatomaceous earth. The drug was measured by analysis in surfaces (wipe samples) and gloves, collected from four different hospitals, before and after the practice of cleaning procedures, and the use of a closed-system device for the preparation and administration. Validation results were satisfactory and cyclophosphamide levels ranging from below the quantification limit to 141000 ng. Our findings demonstrated that surfaces and materials contamination was found in all hospitals during the traditional open technique for preparation and administration of cyclophosphamide and a significant reduction in contamination when a closed-system device was used. However, some values were considered unexpected, especially those obtained from samples collected after the cleaning surfaces.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A nuclear magnetic resonance ((1)H NMR) method for the determination of beta-N-methylamino-L-alanine (L-BMAA) in environmental aqueous samples was developed and validated. L-BMAA is a neurotoxic modified amino acid that can be produced by cyanobacteria in aqueous environments. This toxin was extracted from samples by means of solid-phase extraction (SPE) and identified and quantified by (1)H NMR without further derivatization steps. The lower limit of quantification (LLOQ) was 5 mu g/mL Good inter and intra-assay precision was also observed (relative standard deviation <8.5%) with the use of 4-nitro-DL-phenylalanine as an internal standard (IS). This method of 1H NMR analysis is not time consuming and can be readily utilized to monitor L-BMAA and confirm its presence in environmental and biological samples. (C) 2008 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction - Ayahuasca is obtained by infusing the pounded stems of Banisteriopsis caapi in combination with the leaves of Psychotria viridis. P. viridis is rich in the psychedelic indole N,N-dimethyltryptamine, whereas B. caapi contains substantial amounts of beta-carboline alkaloids, mainly harmine, harmaline and tetrahydroharmine, which are monoamine-oxidase inhibitors. Because of differences in composition in ayahuasca preparations, a method to measure their main active constituents is needed. Objective - To develop a gas chromatographic method for the simultaneous determination of dimethyltryptamine and the main beta-carbolines found in ayahuasca preparations. Methodology - The alkaloids were extracted by means of solid phase extraction (C(18)) and detected by gas chromatography with nitrogen/phosphorous detector. Results - The lower limit of quantification (LLOQ) was 0.02 mg/mL for all analytes. The calibration curves were linear over a concentration range of 0.02-4.0 mg/mL (r(2) > 0.99). The method was also precise (RSD < 10%). Conclusion - A simple gas chromatographic method to determine the main alkaloids found in ayahuasca was developed and validated. The method can be useful to estimate administered doses in animals and humans for further pharmacological and toxicological investigations of ayahuasca. Copyright (C) 2009 John Wiley & Sons, Ltd.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of this study was to evaluate bioequivalence of two commercial 8 mg tablet formulations of ondansetrona available ill the Brazilian market. In this study, a simple, rapid, sensitive and selective liquid chromarography-tandem mass spectrometry method is described for the determination of ondansetron in human plasma samples. The method was validated over a concentration range of 2.5-60 ng/ml and used in a bioequivalence trial between orally disintegrating and conventional tablet ondansetron formulations, to assess its usefulness in this kind of Study. Vonau flash (R) (Biolab Sanus Farmaceutica, Brazil, as test formulations) and Zofran (R) (GlaxoSmithKline, Brazil, as reference formulation) were evaluated following a single 8 mg close to 23 healthy volunteers of both genders. The dose was administered after an overnight fast according to a two-way crossover design. Bioequivalence between the products was determinated by Calculating 90% confidence interval (90% CI) for the ratio of C(max), AUC(0-t) and AUC(0-(sic)) values for the test and reference products, using logarithmically transformed data. The 90% confidence interval for the ratio of C(max) (87.5-103.8%), AUC(0-t) (89.3-107.2%) and AUC(0--(sic)) (89.7-106.0%) values for the test and reference products is Within the 80-125% interval, proposed by FDA, EMEA and ANVISA. It was concluded that two ondansetron formulations are bioequivalent ill their rate and extent of absorption. (C) 2008 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The flavone C-glucoside, vicenin-2, in semi-purified extracts of the leaves of Lychnophora ericoides was quantified in rat plasma samples using a method based on reversed-phase high performance liquid chromatography coupled to tandem mass spectrometry. Vicenin-2 was analyzed on a LiChrospher (R) RP18 column using an isocratic mobile phase consisting of a mixture of methanol: water (30:70, v/v) plus 2.0% glacial acetic acid at a flow rate of 0.8 mL min(-1). Genistein was used as internal standard. The mass spectrometer was operated in positive ionization mode and analytes were quantified by multiple reaction monitoring at m/z 595 > 457 for vicenin-2 and m/z 271 > 153 for internal standard. Prior to the analysis, each rat plasma sample was acidified with 200 mu L of 50 mmol L(-1) acetic acid solution and extracted by solid-phase extraction using a C18 cartridge. The absolute recoveries were reproducible and the coefficients of variation values were lower than 5.2%. The method was linear over the 12.5 - 1500 ng mL(-1) concentration range and the quantification limit was 12.5 ng mL(-1). Within-day and between-day assay precision and accuracy were studied at three concentration levels (40, 400 and 800 ng mL(-1)) and were lower than 15%. The developed and validated method seems to be suitable for analysis of vicenin-2 in plasma samples obtained from rats that receive a single i.p. dose of 200 mg kg(-1) vicenin-2 extract.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Mycophenolic acid is an immunosuppressant administered as a bioavailable ester, mycophenolate mofetil. The pharmacokinetics of mycophenolic acid have been reported to be variable. Accurate measurement of concentrations of this drug could be important to adjust doses. The aim of this study was to compare the enzyme-multiplied immunoassay technique (EMIT [Dade Behring; San Jose, CA, U.S.A.]) for mycophenolic acid with a high-performance liquid chromatographic (HPLC) assay using samples collected from renal transplant recipients. The HPLC assay used solid phase extraction and a C18 stationary phase with ultraviolet (UV) detection (254 nm). The immunoassay required no manual sample preparation. Plasma samples (n = 102) from seven patients, collected at various times after a dose, were analyzed using both methods. Both assays fulfilled quality-control criteria. Higher concentrations were consistently measured in patient samples when using EMIT. The mean (+/- standard deviation [SD]) bias (EMIT-HPLC) was 1.88 +/- 0.86 mg/L. The differences in concentrations were higher in the middle of a dosage interval, suggesting that a metabolite might have been responsible for overestimation. Measurement of glucuronide concentrations by HPLC demonstrated only a weak correlation between assay differences and glucuronide concentrations. If the crossreacting substance is active, EMIT could provide a superior measure of immunosuppression; if inactive, further work is needed to improve antibody specificity. In conclusion, it was found that EMIT overestimates the concentration of mycophenolic acid in plasma samples from renal transplant recipients compared with HPLC analysis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A sensitive high-performance liquid chromatographic assay has been developed for measuring plasma concentrations of methotrexate and its major metabolite, 7-hydroxymethotrexate. Methotrexate and metabolite were extracted from plasma using solid-phase extraction. An internal standard, aminopterin was used. Chromatographic separation was achieved using a 15-cm poly(styrene-divinylbenzene) (PRP-1(R)) column. This column is more robust than a silica-based stationary phase. Post column, the eluent was irradiated with UV light, producing fluorescent photolytic degradation products of methotrexate and the metabolite. The excitation and emission wavelengths of fluorescence detection were at 350 and 435 nm, respectively. The mobile phase consisted of 0.1 M phosphate buffer (pH 6.5), with 6% N,N-dimethylformamide and 0.2% of 30% hydrogen peroxide. The absolute recoveries for methotrexate and 7-hydroxymethotrexate were greater than 86%. Precision, expressed as a coefficient of variation (n=6), was

Relevância:

100.00% 100.00%

Publicador:

Resumo:

To facilitate the investigation of free mycophenolic acid concentrations we developed a high-performance liquid chromatography tandem mass spectrometry method using indomethacin as an internal standard. Free drug was isolated from plasma samples (500 mul) using ultrafiltration, The analytes were extracted from the ultrafiltrate (200 mul) using C-18 solid-phase extraction. Detection was by selected reactant monitoring of mycophenolic acid (m/z 318.9-->190.9) and the internal standard (m/z 356.0-->297.1) with an atmospheric pressure chemical ionisation interface. The total chromatographic analysis time was 12 min. The method was found to be linear over the range investigated, 2.5-200 mug/l (r>0.990, n=6). The relative recovery of the method for the control samples studied (7.5, 40.0 and 150 mug/l) ranged from 95 to 104%. The imprecision of the method, expressed in terms of intra- and inter-day coefficients of variation, was

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Lipopeptides produced by Bacillus subtilis are known for their high antifungal activity. The aim of this paper is to show that at high concentration they can damage the surface ultra-structure of bacterial cells. A lipopeptide extract containing iturin and surfactin (5 mg mL-1) was prepared after isolation from B. subtilis (strain OG) by solid phase extraction. Analysis by atomic force microscope (AFM) showed that upon evaporation, lipopeptides form large aggregates (0.1-0.2 mu m2) on the substrates silicon and mica. When the same solution is incubated with fungi and bacteria and the system is allowed to evaporate, dramatic changes are observed on the cells. AFM micrographs show disintegration of the hyphae of Phomopsis phaseoli and the cell walls of Xanthomonas campestris and X. axonopodis. Collapses to fungal and bacterial cells may be a result of formation of pores triggered by micelles and lamellar structures, which are formed above the critical micelar concentration of lipopeptides. As observed for P. phaseoli, the process involves binding, solubilization, and formation of novel structures in which cell wall components are solubilized within lipopeptide vesicles. This is the first report presenting evidences that vesicles of uncharged and negatively charged lipopeptides can alter the morphology of gram-negative bacteria.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Understanding the excretion of 3,4-methylenedioxymethamphetamine (MDMA) and metabolites in sweat is vital for interpretation of sweat tests in drug treatment, criminal justice, and workplace programs. METHODS: Placebo, low (1.0 mg/kg), and high (1.6 mg/kg) doses of oral MDMA were given double-blind in random order to healthy volunteers (n = 15) with histories of MDMA use. Participants resided on the closed clinical research unit for up to 7 days after each dose. Volunteers wore PharmChek (R) sweat patches (n = 640) before, during, and after controlled dosing. Patches were analyzed by solid phase extraction and GC-MS for MDMA, methylenedioxyamphetamine (MDA), 4-hydroxy-3-methoxyamphetamine (HMA), and 4hydroxy-3-methoxymethamphetamine (HMMA). Limits of quantification (LOQ) were 2.5 ng/patch for MDMA and 5 ng/patch for HMA, HMMA, and MDA. RESULTS: MDMA was the primary analyte detected in 382 patches (59.7%), with concentrations up to 3007 ng/patch. MDA was detected in 188 patches (29.4%) at <172 ng/patch, whereas no HMMA or HMA was detected; 224 patches (35.0%) and 60 patches (9.4%) were positive for MDMA and MDA, respectively, at the 25-ng/patch threshold proposed by the Substance Abuse and Mental Health Services Administration. CONCLUSIONS: Sweat testing was shown to be an effective and reliable method for monitoring MDMA use in this controlled MDMA administration study. However, variability in sweat excretion suggests that results should be interpreted qualitatively rather than quantitatively. These data provide a scientific database for interpretation of MDMA sweat test results. (C) 2008 American Association for Clinical Chemistry

Relevância:

100.00% 100.00%

Publicador:

Resumo:

N,N-dimethyl-pyrrolidinium iodide has been investigated using differential scanning calorimetry, nuclear magnetic resonance (NMR) spectroscopy, second moment calculations, and impedance spectroscopy. This pyrrolidinium salt exhibits two solid-solid phase transitions, one at 373 K having an entropy change, Delta S, of 38 J mol(-1) K-1 and one at 478 K having Delta S of 5.7 J mol(-1) K-1. The second moment calculations relate the lower temperature transition to a homogenization of the sample in terms of the mobility of the cations, while the high temperature phase transition is within the temperature region of isotropic tumbling of the cations. At higher temperatures a further decrease in the H-1 NMR linewidth is observed which is suggested to be due to diffusion of the cations. (C) 2005 American Institute of Physics.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Non-invasive techniques such as the measurement of fecal steroids are now widely used to monitor reproductive hormones in captive and free-ranging wild-life. These methods offer great advantages and deserve to be used in domestic animals. The aim of the present study was to determine the endocrine profile of dairy goats throughout pregnancy by the quantification of fecal progestins and estrogens and assess its con-elation with serum concentrations. Blood and fecal samples were collected weekly from I I adult, multiparous goats, from mating through pregnancy and 2 weeks post-partum. The extraction of estradiol and progesterone fecal metabolites was performed by dilution in ethanol. The radioimmunoassay (RIA) in solid phase was used to quantify serum 17 beta-estradiol (estradiol) and progesterone, as well as their fecal metabolites. The mean concentrations of both fecal and serum estradiol started to increase between weeks 7 and 11, reached peak values near parturition and then decreased sharply (range: 19.8 +/- 5.8 ng/g of feces to 608.6 +/- 472.4 ng/g of feces and 0.007 +/- 0.005 ng/ml to 0.066 +/- 0.024 ng/ml). An increase in both fecal and blood progestagens occurred in the second week, mean concentrations remained greater until week 20, and then decreased in the last week of gestation and 2 weeks post-partum (range: 108.8 +/- 43.6 ng/g of feces to 3119.5 +/- 2076.9 ng/g of feces and 0. 12 +/- 0.04 ng/ml to 13.10 +/- 4.29 ng/ml). The changes in blood and fecal hormone concentrations were analyzed and compared throughout gestation for each single goat, for each breed and for the whole group. Results indicated that matched values of serum and fecal hormone concentrations were correlated (r = 0.79; p < 0.001 for progesterone and r = 0.84;p < 0.001 for estradiol mean concentrations in the whole group). Regression analysis showed that logarithmic model allows significant prediction of serum from fecal concentrations with an R-2 = 0.729 (y = 0.013 1n x - 0.021) for estradiol and R-2 = 0.788 (y = 3.835 1n x - 18.543) for progesterone. Neither fecal nor serum concentrations were affected by the breed but a significant effect of the number of fetuses on progestin concentrations was found. Therefore, the profiles of progesterone and estradiol fecal metabolites reflect the serum concentrations of the same hormones in pregnant goats. (C) 2006 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We report here a validated method for the quantification of a new immunosuppressant drug, everolimus (SDZ RAD), using HPLC-tandem mass spectrometry. Whole blood samples (500 mul) were prepared by protein precipitation, followed by C-18 solid-phase extraction. Mass spectrometric detection was by selected reaction monitoring with an electrospray interface operating in positive ionization mode. The assay was linear from 0.5 to 100 mug/l (r(2) > 0.996, n = 9). The analytical recovery and inter-day imprecision, determined using whole blood quality control samples (n = 5) at 0.5, 1.2, 20.0, and 75.0 mug/l, was 100.3-105.4% and less than or equal to7.6%, respectively. The assay had a mean relative recovery of 94.8 +/- 3.8%. Extracted samples were stable for up to 24 h. Fortified everolimus blood samples were stable at -80 degreesC for at least 8 months and everolimus was found to be stable in blood when taken through at least three freeze-thaw cycles. The reported method provides accurate, precise and specific measurement of everolimus in blood over a wide analytical range and is currently supporting phase 11 and III clinical trials. (C) 2002 Elsevier Science B.V. All rights reserved.