999 resultados para Tomografia Computorizada com multidetectores


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Many solid tumors have a poor response to systemic chemotherapy, local radiotherapy or surgical recession. They are responsible for premature morbidity and decreased patient survival. The radiofrequency ablation is an emerging technique, and is now becoming more widespread throughout the world because it is minimally invasive, image guided, which offers the possibility of an effective and less costly approach. The procedure can be performed percutaneously, guided by several imaging modalities as Ultrasound, Computed Tomography and Magnetic Resonance. This article pretends to demonstrate the state-of-the-art of this technique focusing in the technical aspects and application of radiofrequency ablation.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Development of Dual Source Computed Tomography (Definition, Siemens Medical Solutions, Erlanger, Germany) allowed advances in temporal resolution, with the addition of a second X-ray source and an array of detectors to the TCM 64 slices. The ability to run exams on Dual Energy, allows greater differentiation of tissues, showing differences between closer attenuation coefficients. In terms of renal applications, the distinction of kidney stones and masses become one of the main advantages of the use of dual-energy technology. This article pretends to demonstrate operating principles of this equipment, as its main renal applications.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

RESUMO: Introdução – A Radioterapia (RT) é uma abordagem terapêutica para tratamento de neoplasia de mama. Contudo, diferentes técnicas de irradiação (TI) podem ser usadas. Objetivos – Comparar 4 TI, considerando a irradiação dos volumes alvo (PTV) e dos órgãos de risco (OAR). Metodologia – Selecionaram-se 7 pacientes com indicação para RT de mama esquerda. Sobre tomografia computorizada foram feitos os contornos do PTV e dos OAR. Foram calculadas 4 planimetrias/paciente para as TI: conformacional externa (EBRT), intensidade modulada com 2 (IMRT2) e 5 campos (IMRT5) e arco dinâmico (DART). Resultados – Histogramas de dose volume foram comparados para todas as TI usando o software de análise estatística, IBM SPSS v20. Com IMRT5 e DART, os OAR recebem mais doses baixas. No entanto, IMRT5 apresenta melhores índices de conformidade e homogeneidade para o PTV. Conclusões – IMRT5 apresenta o melhor índice de conformidade; EBRT e IMRT2 apresentam melhores resultados que DART. Há d.e.s entre as TI, sobretudo em doses mais baixas nos OAR.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

contribuindo para o aumento da gordura abdominal, e consequentes complicações metabólicas. O exercício físico permite quebrar este ciclo através da estimulação da lipólise e da utilização de ácidos gordos. Objetivo: Verificar os efeitos de um programa de exercícios no domicílio, em indivíduos com doença arterial coronária, na composição corporal, gordura abdominal, perfil lipídico, glicose, e nível de atividade física. Métodos: Estudo experimental composto por 20 indivíduos, aleatorizados grupo experimental (GE) e grupo de controlo (GC), ambos com 10, tendo o GE sido sujeito ao programa durante 8 semanas. Realizou-se uma avaliação inicial e final, através da bioimpedância, Tomografia Computorizada (TC) abdominal, perimetria, adipometria, análises sanguíneas e acelerómetro. Resultados: Numa análise intergrupal, verificouse uma diminuição da percentagem (%) de gordura total (GT) calculado pela adipometria (p<0.01), na prega supra-ilíaca (p=0.005), na prega abdominal horizontal (p=0.001) e vertical (p=0.003) no GE, e da % de tempo em atividades moderadas no GC (p=0.035). Após 8 semanas o GE diminuiu a %GT (p=0.008); a massa gorda (MG) (p=0.002); perímetro abaixo da última costela (p=0.037) e acima das cristas-ilíacas (p=0.021); %GT calculado (p=0.002); pregas supra-ilíaca (p=0.008), abdominal horizontal (p=0.002) e vertical (p=0.033); TC abdominal subcutâneo (p=0.031) e %de tempo em atividades vigorosas (p=0.031). O GC diminuiu a %GT (p=0.002) e MG (p=0.008); aumentou o perímetro ao nível dos grandes trocânteres (p=0.008), diminuiu o rácio cintura/anca (p=0.002), e a %de tempo em atividades moderadas (p=0.031) e vigorosas (p=0.008). Parece existir uma tendência no GE para diminuição do rácio cintura/anca, c-LDL, triglicerídeos e aumento do nível de atividade moderado. Conclusão: O programa de exercícios no domicílio demonstrou uma diminuição da gordura abdominal, alteração da composição corporal, e parece promover uma melhoria no perfil lipídico e no aumento do nível de atividade física moderado.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Trabalho de Projeto para obtenção do grau de Mestre em Engenharia Informática e de Computadores

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Mestrado em Radiações Aplicadas às Tecnologias da Saúde - Ramo de especialização: Terapia com Radiações

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Mestrado em Intervenção Sócio-Organizacional em Saúde - Ramo de especialização: Políticas de Administração e Gestão de Serviços de Saúde

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Retinal imaging with a confocal scaning laser Ophthalmoscope (cSLO) involves scanning a small laser beam over the retina and constructing an image from the reflected light. By applying the confocal principle, tomographic images can be produced by measuring a sequence of slices at different depths. However, the thickness of such slices, when compared with the retinal thickness, is too large to give useful 3D retinal images, if no processing is done. In this work, a prototype cSLO was modified in terms hardware and software to give the ability of doing the tomographic measurements with the maximum theoretical axial resolution possible. A model eye was built to test the performance of the system. A novel algorithm has been developed which fits a double Gaussian curve to the axial intensity profiles generated from a stack of images slices. The underlying assumption is that the laser light has mainly been reflected by two structures in the retina, the internal limiting membrane and the retinal pigment epithelium. From the fitted curve topographic images and novel thickness images of the retina can be generated. Deconvolution algorithms have also been developed to improve the axial resolution of the system, using a theoretically predicted cSLO point spread function. The technique was evaluated using measurements made on a model eye, four normal eyes and seven eyes containing retinal pathology. The reproducibility, accuracy and physiological measurements obtained, were compared with available published data, and showed good agreement. The difference in the measurements when using a double rather than a single Gaussian model was also analysed.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Introdução – O melanoma maligno cutâneo (MMC) é considerado uma das mais letais neoplasias e no seu seguimento recorre-se, para além dos exames clínicos e da análise de marcadores tumorais, a diversos métodos imagiológicos, como é o exame Tomografia por Emissão de Positrões/Tomografia Computorizada (PET/CT, do acrónimo inglês Positron Emission Tomography/Computed Tomography) com 18fluor-fluorodeoxiglucose (18F-FDG). O presente estudo tem como objetivo avaliar a utilidade da PET/CT relativamente à análise da extensão e à suspeita de recidiva do MMC, comparando os achados imagiológicos com os descritos em estudos CT. Metodologia – Estudo retrospetivo de 62 estudos PET/CT realizados em 50 pacientes diagnosticados com MMC. Excluiu-se um estudo cujo resultado era duvidoso (nódulo pulmonar). As informações relativas aos resultados dos estudos anatomopatológicos e dos exames imagiológicos foram obtidas através da história clínica e dos relatórios médicos dos estudos CT e PET/CT. Foi criada uma base de dados com os dados recolhidos através do software Excel e foi efetuada uma análise estatística descritiva. Resultados – Dos estudos PET/CT analisados, 31 foram considerados verdadeiros positivos (VP), 28 verdadeiros negativos (VN), um falso positivo (FP) e um falso negativo (FN). A sensibilidade, especificidade, o valor preditivo positivo (VPP), o valor preditivo negativo (VPN) e a exatidão da PET/CT para o estadiamento e avaliação de suspeita de recidiva no MMC são, respetivamente, 96,9%, 96,6%, 96,9%, 96,6% e 96,7%. Dos resultados da CT considerados na análise estatística, 14 corresponderam a VP, 12 a VN, três a FP e cinco a FN. A sensibilidade, especificidade, o VPP e o VPN e a exatidão da CT para o estadiamento e avaliação de suspeita de recidiva no MMC são, respetivamente, 73,7%, 80,0%, 82,4%, 70,6% e 76,5%. Comparativamente aos resultados CT, a PET/CT permitiu uma mudança na atitude terapêutica em 23% dos estudos. Conclusão – A PET/CT é um exame útil na avaliação do MMC, caracterizando-se por uma maior acuidade diagnóstica no estadiamento e na avaliação de suspeita de recidiva do MMC comparativamente à CT isoladamente.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Dissertação apresentada na Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para obtenção do grau de Mestre em Engenharia Biomédica

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Individualmente nenhuma modalidade imagiológica oferece em simultâneo uma elevada resolução espacial e temporal, aliado a uma boa resolução de contraste e sensibilidade. No entanto, combinações de diferentes modalidades podem aproximar-se deste ideal, permitindo a integração de diferentes sistemas num sistema de imagem única. Um dos marcos históricos da medicina nuclear ocorreu com o aparecimento dos sistemas de Tomografia por Emissão de Positrões/Tomografia Computorizada (PET/CT) que permitem obter, em simultâneo, informações funcionais e anatómicas sobre as alterações metabólicas e estruturais que ocorrem em situações de doença.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Objetivo do estudo - Comparar as amplitudes respiratórias segundo os eixos x, y e z adquiridos com a tomografia computorizada (TC) 4D e o sistema Calypso® em cancro de pulmão.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Dissertação apresentada à Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para a obtenção do grau de Mestre em Engenharia Biomédica