1000 resultados para GEL


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This thesis presents a mathematical model of the evaporation of colloidal sol droplets suspended within an atmosphere consisting of water vapour and air. The main purpose of this work is to investigate the causes of the morphologies arising within the powder collected from a spray dryer into which the precursor sol for Synroc™ is sprayed. The morphology is of significant importance for the application to storage of High Level Liquid Nuclear Waste. We begin by developing a model describing the evaporation of pure liquid droplets in order to establish a framework. This model is developed through the use of continuum mechanics and thermodynamic theory, and we focus on the specific case of pure water droplets. We establish a model considering a pure water vapour atmosphere, and then expand this model to account for the presence of an atmospheric gas such as air. We model colloidal particle-particle interactions and interactions between colloid and electrolyte using DLVO Theory and reaction kinetics, then incorporate these interactions into an expression for net interaction energy of a single particle with all other particles within the droplet. We account for the flow of material due to diffusion, advection, and interaction between species, and expand the pure liquid droplet models to account for the presence of these species. In addition, the process of colloidal agglomeration is modelled. To obtain solutions for our models, we develop a numerical algorithm based on the Control Volume method. To promote numerical stability, we formulate a new method of convergence acceleration. The results of a MATLAB™ code developed from this algorithm are compared with experimental data collected for the purposes of validation, and further analysis is done on the sensitivity of the solution to various controlling parameters.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: Heat stress might attenuate the effects of carbohydrate on immunoendocrine responses to exercise by increasing endogenous glucose production and reducing the rate of exogenous carbohydrate oxidation. The authors compared the efficacy of carbohydrate consumption on immune responses to exercise in temperate vs. hot conditions. METHODS: Ten male cyclists exercised on 2 separate occasions in temperate (18.1 +/- 0.4 degrees C, 58% +/- 8% relative humidity) and on another 2 occasions in hot conditions (32.2 +/- 0.7 degrees C, 55% +/- 2% relative humidity). On each occasion, the cyclists exercised in a fed state for 90 min at approximately 60% VO2max and then completed a 16.1-km time trial. Every 15 min during the first 90 min of exercise, they consumed 0.24 g/kg body mass of a carbohydrate or placebo gel. RESULTS: Neutrophil counts increased during exercise in all trials (p < .05) and were significantly lower (40%, p = .006) after the carbohydrate than after the placebo trial in 32 degrees C. The concentrations of serum interleukin (IL)-6, IL-8, and IL-10 and plasma granulocyte-colony-stimulating factor, myeloperoxidase, and calprotectin also increased during exercise in all trials but did not differ significantly between the carbohydrate and placebo trials. Plasma norepinephrine concentration increased during exercise in all trials and was significantly higher (50%, p = .01) after the carbohydrate vs. the placebo trial in 32 degrees C. CONCLUSION: Carbohydrate ingestion attenuated neutrophil counts during exercise in hot conditions, whereas it had no effect on any other immune variables in either temperate or hot conditions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work we used a 3D quantitative CT ultrasound imaging system to characterise polymer gel dosimeters. The system comprised of two identical 5 MHz 128 element phased-array ultrasound transducers co-axially aligned and submerged in water as a coupling agent. Rotational and translational movement of the gel dosimeter sample between the transducers were performed using a robotic arm. Ultrasound signals were generated and received using an Olympus Omniscan unit. Dose sensitivity of attenuation and time of flight ultrasonic parameters were assessed using this system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ultrasound has been examined previously as an alternative readout method for irradiated polymer gel dosimeters, with authors reporting varying dose response to ultrasound transmission measurements. In this current work we extend previous work to measure the broadband ultrasound attenuation (BUA) response of irradiated PAGAT gel dosimeters, using a novel ultrasound computed tomography system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this study x-ray CT has been used to produce a 3D image of an irradiated PAGAT gel sample, with noise-reduction achieved using the ‘zero-scan’ method. The gel was repeatedly CT scanned and a linear fit to the varying Hounsfield unit of each pixel in the 3D volume was evaluated across the repeated scans, allowing a zero-scan extrapolation of the image to be obtained. To minimise heating of the CT scanner’s x-ray tube, this study used a large slice thickness (1 cm), to provide image slices across the irradiated region of the gel, and a relatively small number of CT scans (63), to extrapolate the zero-scan image. The resulting set of transverse images shows reduced noise compared to images from the initial CT scan of the gel, without being degraded by the additional radiation dose delivered to the gel during the repeated scanning. The full, 3D image of the gel has a low spatial resolution in the longitudinal direction, due to the selected scan parameters. Nonetheless, important features of the dose distribution are apparent in the 3D x-ray CT scan of the gel. The results of this study demonstrate that the zero-scan extrapolation method can be applied to the reconstruction of multiple x-ray CT slices, to provide useful 2D and 3D images of irradiated dosimetry gels.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Public libraries and coworking spaces seek for means to facilitate peer collaboration, peer inspiration and cross-pollination of skills and creativity. However, social learning, inspiration and collaboration between coworkers do not come naturally. In particular in (semi-) public spaces, the behavioural norm among unacquainted coworkers is to work in individual silos without taking advantage of social learning or collaboration opportunities. This paper presents results from a pilot study of ‘Gelatine’ – a system that facilitates shared encounters between coworkers by allowing them to digitally ‘check in’ at a work space. Gelatine displays skills, areas of interest, and needs of currently present coworkers on a public screen. The results indicate that the system amplifies users’ sense of place and awareness of other coworkers, and serves as an interface for social learning through exploratory, opportunistic and serendipitous inspirations, as well as through helping users identify like-minded peers for follow-up face-to-face encounters. We discuss how Gelatine is perceived by users with different pre-entry motivations, and discuss users’ challenges as well as non-use of the system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: The purpose of this study was to compare twice daily tooth-brushing using 0.304 percent fluoride toothpaste alone with: (1) twice daily tooth-brushing plus once daily 10% casein phosphopeptide-amorphous calcium phosphate (CPP-ACP) paste; and (2) twice daily tooth-brushing plus once daily 0.12% chlorhexidine gel (CHX) for reducing early childhood caries (ECC) and mutans streptococci (MS) colonization. METHODS: Subjects (n=622) recruited at birth were randomized to receive either CPP-ACP or CHX or no product (study control [SC]). All children were examined at 6, 12, and 18 months old in their homes, and at 24 months old in a community dental clinic. RESULTS: At 24 months old, the caries incidence was 1% (2/163) in CPP-ACP, 2% (4/180) in CHX, and 2% (3/188) in SC groups. In children who were previously MS colonized at 12 and 18 months old, 0% (0/11) and 5% (3/63), respectively, of the CPP-ACP group remained MS-positive versus 22% (2/9) and 72% (18/25) in CHX and 16% (4/25) and 50% (7/14) in SC groups (P<.001). CONCLUSIONS: There is insufficient evidence to justify the daily use of casein phosphopeptide-amorphous calcium phosphate or chlorhexidine gel to control early childhood caries.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives This randomised, controlled trial compared the effectiveness of 0.12% chlorhexidine (CHX) gel and 304% fluoride toothpaste to prevent early childhood caries (ECC) in a birth cohort by 24 months. Methods The participants were randomised to receive either (i) twice daily toothbrushing with toothpaste and once daily 0.12% CHX gel (n = 110) or (ii) twice daily toothbrushing with toothpaste only (study controls) (n = 89). The primary outcome measured was caries incidence and the secondary outcome was percentage of children with mutans streptococci (MS). All mothers were contacted by telephone at 6, 12, and 18 months. At 24 months, all children were examined at a community dental clinic. Results At 24 months, the caries prevalence was 5% (3/61) in the CHX and 7% (4/58) in the controls (P = 0.7). There were no differences in percentages of MS-positive children between the CHX and control groups (54%vs 53%). Only 20% applied the CHX gel once daily and 80% less than once daily. Conclusions Toothbrushing using 304% fluoride toothpaste with or without the application of chlorhexidine gel (0.12%) reduces ECC from 23% found in the general community to 5–7%. The lack of effect with chlorhexidine is likely to be due to low compliance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This research developed and scientifically validated a new ultrasound transmission computed tomography system with the aim of quantitative assessment of a polymer gel dosimeter including dose response verification of ultrasonic parameters of attenuation, velocity and broadband ultrasound attenuation (BUA). This work was the first to investigate and report ultrasound frequency dependent attenuation in a gel dosimeter, demonstrating a dose dependence.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study extends the ‘zero scan’ method for CT imaging of polymer gel dosimeters to include multi-slice acquisitions. Multi slice CT images consisting of 24 slices of 1.2 mm thickness were acquired of an irradiated polymer gel dosimeter, and processed with the zero scan technique. The results demonstrate that zero scan based gel readout can be successfully applied to generate a three dimensional image of the irradiated gel field. Compared to the raw CT images the processed figures and cross gel profiles demonstrated reduced noise and clear visibility of the penumbral region. Moreover these improved results further highlight the suitability of this method in volumetric reconstruction with reduced CT data acquisition per slice. This work shows that 3D volumes of irradiated polymer gel dosimeters can be acquired and processed with x-ray CT.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Two sources of uncertainty in the X ray computed tomography imaging of polymer gel dosimeters are investigated in the paper.The first cause is a change in postirradiation density, which is proportional to the computed tomography signal and is associated with a volume change. The second cause of uncertainty is reconstruction noise.A simple technique that increases the residual signal to noise ratio by almost two orders of magnitude is examined.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work we examine two aspects of the PAGAT gel dosimeter. The first aspect studied is determination of a stable range of concentrations of the anti-oxidant Tetrakis Hydroxy Phosphonium Chloride (THPC). Once the desired THPC concentration is determined, we proceed to an investigation into the effect of pre-irradiation storage time and how this affects the dose response of the gel.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Gel dosimetry and plastic chemical dosimeters such as PresageTM are capable of very accurately mapping dose distributions in three dimensions. Combined with their near tissue equivalence one would expect that after several decades of development they would be the dosimeter of choice for dosimetry, however they have not achieve widespread clinical use. This presentation will include a brief description and history of developments in gels and 3D plastics for dosimetry, the limitations and advantages, and their role in the future.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work we test the feasibility of a new calibration method for gel dosimetry. We examine, through Monte Carlo modelling, whether the inclusion of an organic plastic scintillator system at key points within the gel phantom would perturb the dose map. Such a system would remove the requirement for a separate calibration gel, removing many sources of uncertainty.