978 resultados para Dental Prosthesis
Resumo:
Objectives: The aim of this study was to diagnosis oral lesions related to HIV infection in individuals followed in the General Hospital of the School of Medicine of Ribeirao Preto, University of Sao Paulo, Brazil. The presence of oral lesions was correlated with gender, age, smoking habit, levels of CD4 lymphocytes, HIV load, time of HIV seropositivity, AIDS condition, use of removable dental prosthesis, and use of HAART. Materials and Methods: 340 HIV infected individuals were selected for this study, all participants of the study were examined by only one practiced dentist which performed anamnesis, peribuccal and oral examination. Results: Oral lesions were observed in 113 of 340 (33.2%) HIV infected individuals. These oral lesions included: oral candidiasis (17.7%) of pseudomembranous (10.8%) and of erythematous types (6.9%), angular cheilitis (13.9%), hairy leukoplakia (11.8%), and oral ulcers (2.1%). Oral candidiasis lesions were more frequently observed in women (p. 033). Smoking addict participants presented a high frequency of tongue hairy leukoplakia (p. 038) and a reduced frequency of oral ulcers (p. 018). Hairy leukoplakia and pseudomembranous candidiasis were inversely correlated to CD4+ L levels and directly correlated with HIV load, behaving as immune depression markers. Hairy leukoplakia and pseudomembranous candidiasis also showed an inverse correlation with HAART use (p < .0001). Patients using mobile dental prosthesis presented a high frequency of erythematous candidiasis (p. 003). Conclusion: The inverse correlation with CD4+ L level and the direct correlation with HIV load suggest that oral lesions could be used as alternative clinical markers for poor immune condition in HIV infected individuals.
Resumo:
A 41-year-old man with cleft palate presented with a wide dehiscence and missing teeth. Six implants had been placed for fabrication of an overdenture, which was unsatisfactory. A bar was waxed and cast for connection to the implants; precision attachments were placed laterally for retention. A fixed partial denture was fabricated, and milled crowns were fabricated at the molar region to provide a guiding plane for insertion of a removable palatal obturator. Good swallowing and speech outcomes were achieved. This technique provided functional and esthetic benefits, enhanced oral hygiene, and improved the psychological condition of the patient.
Resumo:
Purpose: Gaps between an abutment and a dental implant are unavoidable, and microleakage may occur, leading to problems such as malodor and peri-implantitis. The aim of the present in vitro study was to investigate leakage of Staphylococcus aureus through the implant/abutment interface by the method of bacterial culture, and to compare the leakage rates of two different types of implant-abutment connections. Materials and Methods: Twenty Morse taper implants with abutments were divided into two groups: group A, which were evaluated for microleakage into the inner part of the implants, and group B, which were evaluated for microleakage from the inner part of the implants. Twenty internal-hexagon implants with abutments were also divided into two groups: group C, which were evaluated for microleakage into the inner part of the implants, and group D, which were evaluated for microleakage from the inner part of the implants. For the evaluation of leakage from the implants, the assemblies had the inner parts inoculated with S aureus, and each assembly was incubated in sterile brain heart infusion broth for 1 week. For assessment of leakage into the implants, each assembly was submerged in 4 mL S aureus culture in tubes and incubated for 2 weeks. The microleakage of the two implant connections was compared. Results: Microbial leakage occurred in all groups, and there was no statistically significant difference between groups A and C or between groups B and D. Conclusions: In vitro, S aureus leakage through the implant/abutment interface occurred with both Morse taper and internal-hexagon implants. INT J ORAL MAXILLOFAC IMPLANTS 2011;26:56-62
Resumo:
Purpose: This study evaluated the effect of pattern coating with spinel-based investment Rematitan Ultra (RU) on the castability and internal porosity of commercially pure (CP) titanium invested into phosphate-bonded investments. The apparent porosity of the investment was also measured. Materials and Methods: Square patterns (15 x 15 x 0.3 mm(3)) were either coated with RU, or not and invested into the phosphate-bonded investments: Rematitan Plus (RP), Rema Exakt (RE), Castorit Super C (CA), and RU (control group). The castings were made in an Ar-arc vacuum-pressure machine. The castability area (mm(2)) was measured by an image-analysis system (n = 10). For internal porosity, the casting (12 x 12 x 2 mm(3)) was studied by the X-ray method, and the projected porous area percentage was measured by an image-analysis system (n = 10). The apparent porosity of the investment (n = 10) was measured in accordance with the ASTM C373-88 standard. Results: Analysis of variance (One-way ANOVA) of castability was significant, and the Tukey test indicated that RU had the highest mean but the investing technique with coating increased the castability for all phosphate-bonded investments. The analysis of the internal porosity of the cast by the nonparametric test demonstrated that the RP, RE, and CA with coating and RP without coating did not differ from the control group (RU), while the CA and RE casts without coating were more porous. The one-way ANOVA of apparent porosity of the investment was significant, and the Tukey test showed that the means of RU (36.10%) and CA (37.22%) were higher than those of RP (25.91%) and RE (26.02%). Conclusion: Pattern coating with spinel-based material prior to phosphate-bonded investments can influence the castability and the internal porosity of CP Ti.
Resumo:
Objective The purpose of this study was to evaluate the retention force of an O-ring attachment system in different inclinations to the ideal path of insertion, using devices to compensate angulations. Material and methods Two implants were inserted into an aluminum base, and ball attachments were screwed to implants. Cylinders with O-rings were placed on ball attachments and connected to the test device using positioners to compensate implant angulations (0 degrees, 7 degrees, and 14 degrees). Plexiglass bases were used to simulate implant angulations. The base and the test device were positioned in a testing apparatus, which simulated insertion/removal of an overdenture. A total of 2900 cycles, simulating 2 years of overdenture use, were performed and 36 O-rings were tested. The force required for each cycle was recorded with computer software. Longitudinal sections of ball attachment-positioner-cylinder with O-rings of each angulation were obtained to analyze the relationship among them, and O-ring sections tested in each angulation were compared with an unused counterpart. A mixed linear model was used to analyze the data, and the comparison was performed by orthogonal contrasts (alpha=0.05). Results At 0 degrees, the retention force decreased significantly over time, and the retention force was significantly different in all comparisons, except from 12 to 18 months. When the implants were positioned at 7 degrees, the retention force was statistically different at 0 and 24 months. At 14 degrees, significant differences were found from 6 and 12 to 24 months. Conclusions Within the limitations of this study, it was concluded that O-rings for implant/attachments perpendicular to the occlusal plane were adequately retentive over the first year and that the retentive capacity of O-ring was affected by implant inclinations despite the proposed positioners. To cite this article:Rodrigues RCS, Faria ACL, Macedo AP, Sartori IAM, de Mattos MGC, Ribeiro RF. An in vitro study of non-axial forces upon the retention of an O-ring attachment.Clin. Oral Impl. Res. 20, 2009; 1314-1319.doi: 10.1111/j.1600-0501.2009.01742.x.
Resumo:
Background: Several studies link the seamless fit of implant-supported prosthesis with the accuracy of the dental impression technique obtained during acquisition. In addition, factors such as implant angulation and coping shape contribute to implant misfit. Purpose: The aim of this study was to identify the most accurate impression technique and factors affecting the impression accuracy. Material and Methods: A systematic review of peer-reviewed literature was conducted analyzing articles published between 2009 and 2013. The following search terms were used: implant impression, impression accuracy, and implant misfit.A total of 417 articles were identified; 32 were selected for review. Results: All 32 selected studies refer to in vitro studies. Fourteen articles compare open and closed impression technique, 8 advocate the open technique, and 6 report similar results. Other 14 articles evaluate splinted and non-splinted techniques; all advocating the splinted technique. Polyether material usage was reported in nine; six studies tested vinyl polysiloxane and one study used irreversible hydrocolloid. Eight studies evaluated different copings designs. Intraoral optical devices were compared in four studies. Conclusions: The most accurate results were achieved with two configurations: (1) the optical intraoral system with powder and (2) the open technique with splinted squared transfer copings, using polyether as impression material.
Resumo:
OBJECTIVE: To assess the association between oral health and hygiene practices and oral cancer. METHODS: Hospital-based case-control study in the metropolitan area of São Paulo, southeastern Brazil, from 1998 to 2002. A total 309 patients with squamous cell carcinoma of the mouth and the pharynx and 468 controls matched by sex and age were included in the study. Cases were recruited in seven reference hospitals and controls were selected in five out of the seven participating hospitals. Detailed information on smoking, alcohol consumption, schooling, oral health status and hygiene practices were obtained through interviews. Odds ratios (OR) and 95% confidence intervals (95% CI), adjusted by sex, age, schooling, smoking, alcohol consumption as well as the variables oral health status and hygiene practices were estimated using unconditional logistic regression analyses. RESULTS: The use of complete dental prosthesis was not associated with oral cancer but regular gum bleeding showed a strong association (OR 3.1; 95% CI 1.2-7.9). Those who never attended a dental visit were more likely to have oral cancer (OR 2.5; 95% CI 1.3-4.8). Daily mouthwash use showed a stronger association to pharynx (OR 4.7; 95% CI 1.8-12.5) than mouth cancer (OR 3.2; 95% CI 1.6-6.3). CONCLUSIONS: Gum bleeding, no dental care, and daily mouthwash use were factors associated with oral cancer regardless of tobacco and alcohol consumption.
Resumo:
Dissertação para obtenção do Grau de Mestre em Biotecnologia
Resumo:
Background Several studies link the seamless fit of implant-supported prosthesis with the accuracy of the dental impression technique obtained during acquisition. In addition, factors such as implant angulation and coping shape contribute to implant misfit. Purpose To identify the most accurate impression technique and factors affecting the impression accuracy. Material and Methods A systematic review of peer-reviewed literature was conducted analyzing articles published between 2009 and 2013. The following search terms were used: implant impression, impression accuracy, and implant misfit. A total of 417 articles was identified, 32 were selected for review. Results All 32 selected studies refer to in vitro studies. Fourteen articles compare open and closed impression technique, 8 advocate the open technique and 6 report similar results. Other 14 articles evaluate splinted and non-splinted techniques; all advocating the splinted technique. Polyether material usage was reported in 9; 6 studies tested vinyl polysiloane and 1 study used irreversible hydrocolloid. Eight studies evaluated different copings designs. Intra-oral optical devices were compared in 4 studies. Conclusions The most accurate results were achieved with two configurations: (1) the optical intra-oral system with powder; and (2) the open technique with splinted squared transfer copings, using polyether as impression material.
Resumo:
La aparición de cáncer bucal está vinculada a múltiples factores de riesgo. En este artículo queremos exponer como uno de ellos la úlcera crónica producida por las prótesis dentales removibles o fijas.
Resumo:
La estomatitis protésica es una inflamación crónica de la mucosa oral debida al contacto con una prótesis extraible. Es un proceso difícil de controlar en los pacientes portadores de este tipo de prótesis. La patología involucra diferentes factores predisponentes, y el más importante de ellos es la presencia de Candida. En el presente artículo se describe el manejo del paciente y las dificultades de los tratamientos actuales para eliminar de las prótesis y de la mucosa oral los residuos fúngicos. Se concluye que los hábitos de higiene oral y personal en pacientes portadores de prótesis extraible son los métodos principales para evitar la aparición de la patología. Una vez instaurada, podemos controlar al paciente con medidas higiénicas y agentes antifúngicos, pero debemos ser conscientes de las limitaciones terapéuticas ante los depósitos de Candidade las prótesis. En algunos casos puede estar indicada la sustitución de la prótesis por una nueva.
Resumo:
La prótesis maxilofacial comprende aquellos dispositivos artificiales que restauran una parte ausente de la cara, debido a tumores, traumatismos, o como resultado de una anomalía congénita. El objetivo de este artículo es la exposición de un caso clínico que precisaba la confección de una prótesis óculo-palpebral tras sufrir una pérdida de sustancia por causa oncológica. Este tipo de prótesis son de las más difíciles de elaborar con buenos resultados pues intentan reconstruir un órgano móvil con una prótesis estática. La prótesis maxilofacial tiene la finalidad de aumentar la calidad de vida del paciente y ayudar a la seguridad emocional de los mismos, quedando así rehabilitados para poder integrarse nuevamente en la sociedad.
Resumo:
Objectives: Assess the main problems referred by the patients and observed by the professionals after the bucodental rehabilitation with an implant-supported hybrid prothesis. Patients and Methods: A retrospective study was carried out in which there were 43 patients included who were visited in the Department of Oral Surgery and Orofacial Implantology of University of Barcelona Dental School for one year. An oral rehabilitation with an implant-supported hybrid prosthesis was made to those patients. The following variables were registered: age, gender, number of inserted implants, type of implant and principal problems produced by the hybrid prosthesis. Results: The rehabilitation with an implant supported hybrid prosthesis was only performed in 43 of 116 cases treated in one year (January, 2006 to January, 2007). They were 26 men and 17 women of ages between 37 and 74 years, being the rate age of 56,5 years. The main complication recorded was the mucositis, associated frequently with a difficulty to carry a correct oral hygiene and to an overextention of the tail of resin of the prosthesis. Other observed problems were the peri-implantitis, the break of the acrylic teeth and the loss of some of the prosthetic screws. Conclusions: The most frequent complication after the laying of an implant supported hybrid prosthesis was the mucositis, associated mainly with a prosthetic tail too long and to the consequent difficulty of carrying a correct oral hygiene. In spite of the high prevalence of observed complications, most of them were mild and resolved on subsequent visits.
Resumo:
Introduction: The overeruption of upper molars due to the premature loss of antagonist teeth can be treated with the help of miniscrews. The aim of this study was to evaluate the movement of a typodont molar according to the biomechanical approach used with miniscrews. Study design: The study was conducted with four plaster models filled with typodont wax. In each model we used one absolute anchorage on the palatal side and another on the buccal side in different positions, thus generating four different biomechanical systems. A force of 150 g was applied to each side of the resin tooth. Periapical radiographs were taken preintrusion and immediately after completion of the intrusion. Photographs were taken in both the sagittal and occlusal planes every 3 min. The radiographic films and photographs were measured and compared. Results: A vertical movement of the molar was observed in all the models, with system 4 showing the greatest movement. Rotation in the occlusal plane only occurred in system 2, while in system 1 there was a change in the axial axis of 37 degrees. Conclusions: The anchorage site and the combination of forces applied may determine the resulting tooth movement