Accuracy comparison of implant impression techniques: A systematic review


Autoria(s): Moreira, António Herculano Jesus; Rodrigues, Nuno F.; Pinho, A. C. Marques de; Fonseca, Jaime C.; Vilaça, João L.
Data(s)

01/10/2015

Resumo

Background Several studies link the seamless fit of implant-supported prosthesis with the accuracy of the dental impression technique obtained during acquisition. In addition, factors such as implant angulation and coping shape contribute to implant misfit. Purpose To identify the most accurate impression technique and factors affecting the impression accuracy. Material and Methods A systematic review of peer-reviewed literature was conducted analyzing articles published between 2009 and 2013. The following search terms were used: implant impression, impression accuracy, and implant misfit. A total of 417 articles was identified, 32 were selected for review. Results All 32 selected studies refer to in vitro studies. Fourteen articles compare open and closed impression technique, 8 advocate the open technique and 6 report similar results. Other 14 articles evaluate splinted and non-splinted techniques; all advocating the splinted technique. Polyether material usage was reported in 9; 6 studies tested vinyl polysiloane and 1 study used irreversible hydrocolloid. Eight studies evaluated different copings designs. Intra-oral optical devices were compared in 4 studies. Conclusions The most accurate results were achieved with two configurations: (1) the optical intra-oral system with powder; and (2) the open technique with splinted squared transfer copings, using polyether as impression material.

FCT – Fundação para a Ciência e Tecnologia in the scope of the Ph.D. grant SFRH/BD/68270/2010, project EXPL/BBB-BMD/2146/2013 and within the Project Scope UID/CEC/00319/2013

Identificador

Moreira, A. H., Rodrigues, N. F., Pinho, A., Fonseca, J. C., & Vilaça, J. L. (2015). Accuracy Comparison of Implant Impression Techniques: A Systematic Review. Clinical implant dentistry and related research, 17(S2), e751-e764

Moreira, A. H. J., Rodrigues, N. F., Pinho, A. C. M., Fonseca, J. C., & Vilaca, J. L. (2015). Accuracy Comparison of Implant Impression Techniques: A Systematic Review. Clinical Implant Dentistry and Related Research, 17, E751-E764. doi: 10.1111/cid.12310

1523-0899

1708-8208

http://hdl.handle.net/1822/40227

10.1111/cid.12310

Idioma(s)

eng

Publicador

Wiley

Relação

info:eu-repo/grantAgreement/FCT/5876-PPCDTI/135171/PT

info:eu-repo/grantAgreement/FCT/5876/147280/PT

info:eu-repo/grantAgreement/FCT/5876-PPCDTI/135171/PT

http://onlinelibrary.wiley.com/doi/10.1111/cid.12310/full

Direitos

info:eu-repo/semantics/openAccess

Palavras-Chave #Implant impression #Implant misfit #Impression accuracy #Optical scanning #Dental prosthesis
Tipo

info:eu-repo/semantics/article