946 resultados para weld quality control
Resumo:
Plain radiography still accounts for the vast majority of imaging studies that are performed at multiple clinical instances. Digital detectors are now prominent in many imaging facilities and they are the main driving force towards filmless environments. There has been a working paradigm shift due to the functional separation of acquisition, visualization, and storage with deep impact in the imaging workflows. Moreover with direct digital detectors images are made available almost immediately. Digital radiology is now completely integrated in Picture Archiving and Communication System (PACS) environments governed by the Digital Imaging and Communications in Medicine (DICOM) standard. In this chapter a brief overview of PACS architectures and components is presented together with a necessarily brief account of the DICOM standard. Special focus is given to the DICOM digital radiology objects and how specific attributes may now be used to improve and increase the metadata repository associated with image data. Regular scrutiny of the metadata repository may serve as a valuable tool for improved, cost-effective, and multidimensional quality control procedures.
Resumo:
O presente Relatório de Estágio teve como objectivo analisar e discutir as competências adquiridas e desenvolvidas, durante o estágio, no controlo da qualidade microbiológica na indústria farmacêutica O estágio, foi realizado no Laboratório de Microbiologia dos Laboratórios Atral, Grupo AtralCipan, localizado na Vala do Carregado, Castanheira do Ribatejo. Este teve a duração de aproximadamente dez meses e meio, com data de início a 21 de Setembro de 2011 e final de 10 de Agosto de 2012. Numa fase inicial, foram adquiridas as aptidões necessárias para a aplicação das metodologias realizadas no laboratório de microbiologia com o estudo das normas, procedimento e legislação aplicada, com foco na importância das farmacopeias na indústria farmacêutica e formação para a realização de ensaios em Áreas de Processamento Asséptico, conhecendo e compreendendo os procedimentos a ter nestas. Uma das principais metodologias realizadas, e desenvolvida neste relatório, compreendeu a análise de produtos farmacêuticos estéreis, com a aplicação de Testes de Esterilidade, pelo método de STERITEST e método Directo, com resultados que demonstraram a importância destas técnicas, da avaliação do ambiente em que são realizadas e do operador que as executa. Os Testes de Promoção de Crescimento, foram também explorados neste trabalho, realizados não só para avaliação dos meios de cultura, onde foi possível analisar os requisitos e resultados obtidos, como também para validação de metodologias, nomeadamente, na validação de meios e fluidos de marcas diferentes para utilização no método STERITEST e na validação do método de filtração de membrana para Enumeração Microbiana de um produto não estéril. Estas validações possibilitaram a redução de custos e melhoria das condições da análise e metodologias aplicadas. Com a realização do estágio foi possível adquirir aptidões práticas, que aliadas ao conhecimento teórico obtido no mestrado, proporcionaram um crescimento a nível pessoal, científico e profissional.
Resumo:
Mestrado em Radiações Aplicadas às Tecnologias da Saúde. Área de especialização: Imagem Digital.
Resumo:
Mestrado em Radiações Aplicadas às Tecnologias da Saúde. Área de especialização: Imagem Digital com Radiação X.
Resumo:
Jornadas "Ciência nos Açores – que futuro? Tema Ciências Naturais e Ambiente", Ponta Delgada, 7-8 de Junho de 2013.
Resumo:
There is an imminent need for rapid methods to detect and determine pathogenic bacteria in food products as alternatives to the laborious and time-consuming culture procedures. In this work, an electrochemical immunoassay using iron/gold core/shell nanoparticles (Fe@Au) conjugated with anti-Salmonella antibodies was developed. The chemical synthesis and functionalization of magnetic and gold-coated magnetic nanoparticles is reported. Fe@Au nanoparticles were functionalized with different self-assembled monolayers and characterized using ultraviolet-visible spectrometry, transmission electron microscopy, and voltammetric techniques. The determination of Salmonella typhimurium, on screen-printed carbon electrodes, was performed by square-wave anodic stripping voltammetry through the use of CdS nanocrystals. The calibration curve was established between 1×101 and 1×106 cells/mL and the limit of detection was 13 cells/mL. The developed method showed that it is possible to determine the bacteria in milk at low concentrations and is suitable for the rapid (less than 1 h) and sensitive detection of S. typhimurium in real samples. Therefore, the developed methodology could contribute to the improvement of the quality control of food samples.
Resumo:
Dissertação de Mestrado apresentado ao Instituto de Contabilidade e Administração do Porto para a obtenção do grau de Mestre em Auditoria, sob orientação da Doutora Alcina Portugal Dias
Resumo:
As macroalgas marinhas têm uma grande diversidade de aplicações. Nos Açores, várias espécies têm sido usadas tradicionalmente para alimentação humana e para extração de agar, um ficocolóide aplicado na indústria alimentar e farmacêutica. As exigências no controlo da qualidade das matérias-primas e as práticas atuais de colheita de macroalgas marinhas selvagens na Europa exigem uma gestão eficaz deste recurso natural e, simultaneamente, tornam premente a necessidade de se implementarem métodos de produção de biomassa controlados, nomeadamente, práticas de cultivo. Apesar da importância reconhecida da exploração sustentável dos recursos marinhos existentes nos Açores, não existe qualquer informação sobre a viabilidade do cultivo de macroalgas marinhas no Arquipélago. O objetivo principal do presente projeto é avaliar o potencial de cultivo de espécies de macroalgas marinhas selecionadas, bem como identificar as melhores práticas de recolha desse recurso natural.
Resumo:
Environmental pollution continues to be an emerging study field, as there are thousands of anthropogenic compounds mixed in the environment whose possible mechanisms of toxicity and physiological outcomes are of great concern. Developing methods to access and prioritize the screening of these compounds at trace levels in order to support regulatory efforts is, therefore, very important. A methodology based on solid phase extraction followed by derivatization and gas chromatography-mass spectrometry analysis was developed for the assessment of four endocrine disrupting compounds (EDCs) in water matrices: bisphenol A, estrone, 17b-estradiol and 17a-ethinylestradiol. The study was performed, simultaneously, by two different laboratories in order to evaluate the robustness of the method and to increase the quality control over its application in routine analysis. Validation was done according to the International Conference on Harmonisation recommendations and other international guidelines with specifications for the GC-MS methodology. Matrix-induced chromatographic response enhancement was avoided by using matrix-standard calibration solutions and heteroscedasticity has been overtaken by a weighted least squares linear regression model application. Consistent evaluation of key analytical parameters such as extraction efficiency, sensitivity, specificity, linearity, limits of detection and quantification, precision, accuracy and robustness was done in accordance with standards established for acceptance. Finally, the application of the optimized method in the assessment of the selected analytes in environmental samples suggested that it is an expedite methodology for routine analysis of EDC residues in water matrices.
Resumo:
In this paper, we present the results of mammography quality control tests related to the work with Portuguese mammography equipment, either in conventional or in digital mammography computed radiography, showing the main differences in the tested equipments. Quality control in mammography is a very special area of quality control in radiology, which demands relatively high knowledge on physics. Digital imaging is changing the standards of the radiographic imaging. Regarding mammography, this is yet a controversial issue owing to some limitations of the digital detectors, like the resolution for instance. A complete set of results regarding radiation protection of the patients submitted to mammography diagnosis is presented. A discussion of the quality image parameters and its interpretation in conventional and digital mammography is presented. In conclusion, we present a sample of results that can be considered as characteristics of mammography equipment in Portugal.
Resumo:
A calibração e o controlo da qualidade de um acelerador linear são passos muito importantes num serviço de Radioterapia, para garantir a qualidade dos tratamentos prestados. O sector da Física da Unidade de Radioterapia do Hospital Cuf Descobertas implementou um rigoroso Programa de controlo de qualidade ao equipamento produtor de radiação e aos equipamentos medidores de radiação, de acordo com o Dec-Lei 180/2002 e com os protocolos internacionais. Para tal, foram implementados procedimentos, criadas folhas de cálculo, instruções de trabalho e impressos. Foram ainda implementados testes aos equipamentos com periodicidade definida: controlo de qualidade diário e controlo de qualidade após intervenções (manutenções preventivas e correctivas). No decorrer do ano de 2005, o sector da Física colaborou activamente com toda a equipa da Radioterapia na implementação da Norma ISO 9001:2000 no serviço, contribuindo com o seu know how na implementação desta, numa área tão importante como a da garantia da qualidade dos feixes de radiação e das respectivas calibrações em dose. Numa procura de melhoria contínua da qualidade dos serviços prestados aos pacientes, decorre ainda uma auditoria externa da EQUAL-ESTRO*, intercomparação postal com dosímetros termoluminescentes. A qualidade dos feixes de energias utilizados diariamente é analisada, tanto ao nível das calibrações absolutas de cada um dos feixes de fotões e de electrões, como ao nível dos cálculos de dose obtidos com o sistema de planimetria XiO da CMS. Os resultados das duas primeiras fases da intercomparação, relativa aos dois feixes de fotões de 6 MV e 15 MV e feixes de electrões de 4 MeV, 8 MeV e 12 MeV, foram considerados pela EQUAL-ESTRO num nível óptimo (desvio máximo na dose medida em relação à dose de referência |d| ≤ 3%).
Resumo:
GOAL: The manufacturing and distribution of strips of instant thin - layer chromatography with silica gel (ITLC - SG) (reference method) is currently discontinued so there is a need for an alternative method f or the determination of radiochemical purity (RCP) of 99m Tc - tetrofosmin. This study aims to compare five alternative methods proposed by the producer to determine the RCP of 99m Tc - tetrofosmin. METHODS: Nineteen vials of tetrofosmin were radiolabelled with 99m Tc and the percentages of the RCP were determined. Five different methods were compared with the standard RCP testing method (ITLC - SG, 2x20 cm): Whatman 3MM (1x10 cm) with acetone and dichloro - methane (method 1); Whatman 3MM (1x1 0 cm) with ethyl acetate (method 2); aluminum oxide - coated plastic thin - layer chromatography (TLC) plate (1x10 cm) and ethanol (method 3); Whatman 3MM (2x20 cm) with acetone and dichloro - methane (method 4); solid - phase extraction method C18 cartridge (meth od 5). RESULTS: The average values of RCP were 95,30% ± 1,28% (method 1), 93,95 ± 0,61% (method 2), 96,85% ± 0,93% (method 3), 92,94% ± 0,99% (method 4) and 96,25% ± 2,57% (method 5) (n=12 each), and 93,15% ± 1,13% for the standard method (n=19). There we re statistical significant differences in the values obtained for methods 1 (P=0,001), 3 (P=0,000) and 5 (P=0,004), and there were no statistical significant differences in the values obtained for methods 2 (P=0,113) and 4 (P=0,327). CONCLUSION: From the results obtained, methods 2 and 4 showed a higher correlation with the standard method. Unlike method 4, method 2 is less time - consuming than the reference method and can overcome the problems associated with the solvent toxicity. The remaining methods (1, 3 and 5) tended to overestimate RCP value compared to the standard method.
Resumo:
Dissertação de Mestrado em Ambiente, Saúde e Segurança.
Resumo:
O objectivo do presente trabalho foi caracterizar os condensados produzidos numa fábrica de pasta para papel para identificar e localizar pontos da sua contaminação. Para o efeito, foram recolhidas amostras de condensado e caracterizados os parâmetros condutividade, pH, sódio e sílica. A amostragem decorreu no período entre 15 de Setembro a 6 de Novembro de 2008. Através da análise dos resultados obtidos para as concentrações de sílica e de sódio de cada uma das correntes, foram identificadas como contaminadas as correntes de condensado provenientes do condensador do Turbogerador 4, da área dos Digestores Descontínuos, da Evaporação e do Aquecedor de Água Quente para o Branqueamento. A realização de um balanço pontual à sílica no tanque de condensados da Central permitiu concluir que a maior contribuição advém do condensador do Turbogerador 4. Na Evaporação ocorre contaminação do condensado quando as secções do Concentrador 1 são colocadas em serviço após lavagem. Durante o acompanhamento do arranque da Evaporação, uma das secções (1/B) registou um valor máximo na concentração de sódio no condensado de 135 mg/L Na. Do estudo resulta, enquanto não for reparado e/ou substituído o equipamento responsável pelas contaminações, a necessidade de admitir requisitos para controlo da qualidade da água da caldeira menos restritivos, nomeadamente para a razão sódio/fosfato. É necessário, contudo, o rigoroso acompanhamento da qualidade da água da caldeira (pH, sobretudo) para prevenir afastamentos inesperados dos limites de controlo. Durante a realização deste trabalho foram identificadas algumas situações a melhorar, tais como a uniformização dos valores de desvio para esgoto dos condensados e das unidades utilizadas, a adequação das escalas dos aparelhos de medida para as gamas de leitura de interesse, a verificação e calibração periódica do equipamento instalado em linha, a adopção do parâmetro “Sódio” para controlo da qualidade dos condensados, a instalação de sistemas de amostragem com arrefecimento em todas as correntes de condensados e a reparação ou substituição de algum equipamento instalado em linha que se encontra em muito mau estado e ainda a manutenção do equipamento mantendo-o em boas condições de limpeza.
Resumo:
Mestrado em Controlo e Gestão dos Negócios