885 resultados para Cascaded multilevel inverter


Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper is on the problem of short-term hydro scheduling, particularly concerning head-dependent reservoirs under competitive environment. We propose a new nonlinear optimization method to consider hydroelectric power generation as a function of water discharge and also of the head. Head-dependency is considered on short-term hydro scheduling in order to obtain more realistic and feasible results. The proposed method has been applied successfully to solve a case study based on one of the main Portuguese cascaded hydro systems, providing a higher profit at a negligible additional computation time in comparison with a linear optimization method that ignores head-dependency.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Several didactic modules for an electric machinery laboratory are presented. The modules are dedicated for DC machinery control and get their characteristic curves. The didactic modules have a front panel with power and signal connectors and can be configurable for any DC motor type. The three-phase bridge inverter proposed is one of the most popular topologies and is commercially available in power package modules. The control techniques and power drives were designed to satisfy static and dynamic performance of DC machines. Each power section is internally self-protected against misconnections and short-circuits. Isolated output signals of current and voltage measurements are also provided, adding versatility for use either in didactic or research applications. The implementation of such modules allowed experimental confirmation of the expected performance.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A geração de energia elétrica a partir de fontes renováveis, tal como as centrais eólicas, apresenta diferente disponibilidade ao longo do tempo. Por esse motivo, a crescente integração da energia eólica no sistema elétrico levanta questões operacionais importantes, tal como o equilíbrio entre a potência da geração e a potência do consumo, podendo em certos períodos, ocorrer fenómenos de excesso de geração. Atualmente, as centrais hídricas reversíveis (CHR) têm sido vistas como uma solução para absorver esse excesso de geração, evitando-se assim, a necessidade de corte da geração eólica. Num contexto de mercado liberalizado, considerando-se que as CHR são tomadoras de preço, nos períodos de baixo consumo e elevada disponibilidade de vento, o baixo preço da energia elétrica dará incentivo para as CHR realizem bombagem, promovendo a integração da energia eólica. No entanto, se uma CHR apresentar poder de mercado, a sua estratégia de maximização do lucro pode levar a um perfil de bombagem e geração diferente, desviando-se do objetivo de maximizar a integração da energia eólica. Neste sentido, o presente trabalho tem como objetivo estudar a influência do poder de mercado na operação de uma CHR inserida no mercado diário do mercado ibérico de eletricidade (MIBEL). Para tal, é desenvolvido um modelo de despacho em ambiente de mercado, sendo o poder de mercado da CHR modelado através de uma curva de procura residual inversa com elasticidade variável. Os resultados obtidos evidenciam que o aumento do poder de mercado da CHR corresponde a uma diminuição do nível de energia armazenada e, portanto, a capacidade de integrar energia eólica pode ser consideravelmente reduzida. No entanto, quando a CHR pertence a uma empresa de geração que para além desta, possui também uma central de tecnologia diferente, tal como uma central térmica ou eólica, o seu comportamento pode inverter-se.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper presents a variable speed autonomous squirrel cage generator excited by a current-controlled voltage source inverter to be used in stand-alone micro-hydro power plants. The paper proposes a system control strategy aiming to properly excite the machine as well as to achieve the load voltage control. A feed-forward control sets the appropriate generator flux by taking into account the actual speed and the desired load voltage. A load voltage control loop is used to adjust the generated active power in order to sustain the load voltage at a reference value. The control system is based on a rotor flux oriented vector control technique which takes into account the machine saturation effect. The proposed control strategy and the adopted system models were validated both by numerical simulation and by experimental results obtained from a laboratory prototype. Results covering the prototype start-up, as well as its steady-state and dynamical behavior are presented. (C) 2011 Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Power converters play a vital role in the integration of wind power into the electrical grid. Variable-speed wind turbine generator systems have a considerable interest of application for grid connection at constant frequency. In this paper, comprehensive simulation studies are carried out with three power converter topologies: matrix, two-level and multilevel. A fractional-order control strategy is studied for the variable-speed operation of wind turbine generator systems. The studies are in order to compare power converter topologies and control strategies. The studies reveal that the multilevel converter and the proposed fractional-order control strategy enable an improvement in the power quality, in comparison with the other power converters using a classical integer-order control strategy. (C) 2010 Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this paper, a novel mixed-integer nonlinear approach is proposed to solve the short-term hydro scheduling problem in the day-ahead electricity market, considering not only head-dependency, but also start/stop of units, discontinuous operating regions and discharge ramping constraints. Results from a case study based on one of the main Portuguese cascaded hydro energy systems are presented, showing that the proposedmixed-integer nonlinear approach is proficient. Conclusions are duly drawn. (C) 2010 Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper is on variable-speed wind turbines with permanent magnet synchronous generator (PMSG). Three different drive train mass models and three different topologies for the power-electronic converters are considered. The three different topologies considered are respectively a matrix, a two-level and a multilevel converter. A novel control strategy, based on fractional-order controllers, is proposed for the wind turbines. Simulation results are presented to illustrate the behaviour of the wind turbines during a converter control malfunction, considering the fractional-order controllers. Finally, conclusions are duly drawn. Copyright (C) 2010 John Wiley & Sons, Ltd.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Ao longo das últimas décadas assistimos à destruição de enormes manchas verdes com o intuito de explorar os maciços rochosos sob estas, a partir dos quais se produzem os agregados necessários à utilização na construção civil e nas obras públicas. Porém, nos últimos anos, esta situação tem vindo a inverter-se, assistindo-se, cada vez mais, a uma preocupação global na mitigação do impacte ambiental de tal exploração desenfreada e na redução dos custos da construção. A península de Troia foi um dos mais significativos exemplos na mitigação dessas preocupações, tendo-se reutilizado 109.200 m3 de resíduos de construção e demolição na construção de novos arruamentos, na base de edifícios, na execução de poços drenantes e em infraestruturas provisórias, dos cerca de 130.700 m3 de diversos tipos de resíduos produzidos, representando uma reutilização a rondar os 92%. Pretende-se com esta dissertação, apresentar uma vertente de valorização dos RCD demonstrando as vantagens na sua reutilização, sem deixar de dar a conhecer um pouco melhor a Península de Troia, outrora tão importante nas rotas comerciais, o atual ponto de situação relativo à reutilização de RCD, assim como as atuais questões legais pelas quais se rege, atualmente, a utilização de Resíduos de Construção e Demolição.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: To identify factors associated to poor glycemic control among diabetic patients seen at primary health care centers. METHODS: A cross-sectional study was carried out in a sample of 372 diabetic patients attending 32 primary health care centers in southern Brazil. Data on three hierarchical levels of health unit infrastructure, medical care and patient characteristics were collected. RESULTS: The frequency of poor glycemic control was 50.5%. Multivariate analysis (multilevel method) showed that patients with body mass indexes below 27 kg/m², patients on oral hypoglycemic agents or insulin, and patients diagnosed as diabetic over five years prior to the interview were more likely to present poor glycemic control when compared to their counterparts. CONCLUSIONS: Given the hierarchical data structuring, all associations found suggest that factors associated to hyperglycemia are related to patient-level characteristics.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Trabalho desenvolvido para a apresentação em Provas Públicas para atribuição do título de Especialista em Engenharia e Gestão Industrial

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Mestrado em Engenharia Química. Ramo optimização energética na indústria química

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dissertação para obtenção do grau de Mestre em Engenharia Electrotécnica Ramo de Automação e Electrónica Industrial

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dissertação para a obtenção do grau de Mestre em Engenharia Electrotécnica Ramo de Automação e Electrónica Industrial

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Trabalho Final de Mestrado para a obtenção do grau de Mestre em Engenharia Electrotécnica Ramo de Automação e Electrónica Industrial

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dissertação para obtenção do grau de Mestre em Engenharia Electrotécnica Ramo de Automação e Electrónica Industrial