930 resultados para Dioxide CRO2 Films


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Three types of carbon dioxide-baited traps, i.e., the Centers for Disease Control Miniature Light Trap without light, the BioGents (BG) Sentinel Mosquito Trap (BG-Sentinel) and the Mosquito Magnet® Liberty Plus were compared with human landing collections in their efficiency in collecting Anopheles (Nyssorhynchus) aquasalis mosquitoes. Of 13,549 total mosquitoes collected, 1,019 (7.52%) were An. aquasalis. Large numbers of Culex spp were also collected, in particular with the (BG-Sentinel). The majority of An. aquasalis (83.8%) were collected by the human landing collection (HLC). None of the trap catches correlated with HLC in the number of An. aquasalis captured over time. The high efficiency of the HLC method indicates that this malaria vector was anthropophilic at this site, especially as carbon dioxide was insufficiently attractive as stand-alone bait. Traps using carbon dioxide in combination with human odorants may provide better results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this report we present the growth process of the cobalt oxide system using reactive electron beam deposition. In that technique, a target of metallic cobalt is evaporated and its atoms are in-flight oxidized in an oxygen rich reactive atmosphere before reaching the surface of the substrate. With a trial and error procedure the deposition parameters have been optimized to obtain the correct stoichiometry and crystalline phase. The evaporation conditions to achieve the correct cobalt oxide salt rock structure, when evaporating over amorphous silicon nitride, are: 525 K of substrate temperature, 2.5·10-4 mbar of oxygen partial pressure and 1 Ã/s of evaporation rate. Once the parameters were optimized a set of ultra thin film ranging from samples of 1 nm of nominal thickness to 20nm thick and bulk samples were grown. With the aim to characterize the samples and study their microstructure and morphology, X-ray diffraction, transmission electron microscopy, electron diffraction, energy dispersive X-ray spectroscopy and quasi-adiabatic nanocalorimetry techniques are utilised. The final results show a size dependent effect of the antiferromagnetic transition. Its Néel temperature becomes depressed as the size of the grains forming the layer decreases.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

L'article se propose de discuter la question des modalités de la référence aux évangiles au cinéma en s'attachant à l'étude de la composante verbale et de ses liens avec la représentation de la figure christique dans deux films: le premier, Ben-Hur (Fred Niblo, 1925), est une superproduction produite par Hollywood à l'époque de l'apogée du muet; le second, Golgotha (1935), est réalisé par le cinéaste français Julien Duvivier durant les premières années de la généralisation du parlant. D'un côté l'écrit (sous forme d'intertitres), de l'autre la profération orale d'un texte. Le rapprochement proposé entre ces deux films tient à la façon dont la citation néotestamentaire participe à la construction par le film de la figure de Jésus, ou plutôt à la mise à distance de celle-ci, constamment rejetée dans une forme de hors-champ.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Saffaj et al. recently criticized our method of monitoring carbon dioxide in human postmortem cardiac gas samples using Headspace-Gas Chromatography-Mass Spectrometry. According to the authors, their demonstration, based on the latest SFSTP guidelines (established after 2007 [1,2]) fitted for the validation of drug monitoring bioanalytical methods, has put in evidence potential errors. However, our validation approach was built using SFSTP guidelines established before 2007 [3-6]. We justify the use of these guidelines because of the post-mortem context of the study (and not clinical) and the gaseous state of the sample (and not solid or liquid). Using these guidelines, our validation remains correct.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In 58 newborn infants a new iridium oxide sensor was evaluated for transcutaneous carbon dioxide (tcPCO2) monitoring at 42 degrees C with a prolonged fixation time of 24 hours. The correlation of tcPCO2 (y; mm Hg) v PaCO2 (x; mm Hg) for 586 paired values was: y = 4.6 + 1.45x; r = .89; syx = 6.1 mm Hg. The correlation was not influenced by the duration of fixation. The transcutaneous sensor detected hypocapnia (PaCO2 less than 35 mm Hg) in 74% and hypercapnia (PCO2 greater than 45 mm Hg) in 74% of all cases. After 24 hours, calibration shifts were less than 4 mm Hg in 90% of the measuring periods. In 86% of the infants, no skin changes were observed; in 12% of infants, there were transitional skin erythemas and in 2% a blister which disappeared without scarring. In newborn infants with normal BPs, continuous tcPCO2 monitoring at 42 degrees C can be extended for as many as 24 hours without loss of reliability or increased risk for skin burns.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

IMPLICATIONS: A new combined ear sensor was tested for accuracy in 20 critically ill children. It provides noninvasive and continuous monitoring of arterial oxygen saturation, arterial carbon dioxide tension, and pulse rate. The sensor proved to be clinically accurate in the tested range.