946 resultados para National Research Council (U.S.)


Relevância:

100.00% 100.00%

Publicador:

Resumo:

RESUMO: O cancro de mama e o mais frequente diagnoticado a indiv duos do sexo feminino. O conhecimento cientifico e a tecnologia tem permitido a cria ção de muitas e diferentes estrat egias para tratar esta patologia. A Radioterapia (RT) est a entre as diretrizes atuais para a maioria dos tratamentos de cancro de mama. No entanto, a radia ção e como uma arma de dois canos: apesar de tratar, pode ser indutora de neoplasias secund arias. A mama contralateral (CLB) e um orgão susceptivel de absorver doses com o tratamento da outra mama, potenciando o risco de desenvolver um tumor secund ario. Nos departamentos de radioterapia tem sido implementadas novas tecnicas relacionadas com a radia ção, com complexas estrat egias de administra ção da dose e resultados promissores. No entanto, algumas questões precisam de ser devidamente colocadas, tais como: E seguro avançar para tecnicas complexas para obter melhores indices de conformidade nos volumes alvo, em radioterapia de mama? O que acontece aos volumes alvo e aos tecidos saudaveis adjacentes? Quão exata e a administração de dose? Quais são as limitações e vantagens das técnicas e algoritmos atualmente usados? A resposta a estas questões e conseguida recorrendo a m etodos de Monte Carlo para modelar com precisão os diferentes componentes do equipamento produtor de radia ção(alvos, ltros, colimadores, etc), a m de obter uma descri cão apropriada dos campos de radia cão usados, bem como uma representa ção geometrica detalhada e a composição dos materiais que constituem os orgãos e os tecidos envolvidos. Este trabalho visa investigar o impacto de tratar cancro de mama esquerda usando diferentes tecnicas de radioterapia f-IMRT (intensidade modulada por planeamento direto), IMRT por planeamento inverso (IMRT2, usando 2 feixes; IMRT5, com 5 feixes) e DCART (arco conformacional dinamico) e os seus impactos em irradia ção da mama e na irradia ção indesejada dos tecidos saud aveis adjacentes. Dois algoritmos do sistema de planeamento iPlan da BrainLAB foram usados: Pencil Beam Convolution (PBC) e Monte Carlo comercial iMC. Foi ainda usado um modelo de Monte Carlo criado para o acelerador usado (Trilogy da VARIAN Medical Systems), no c odigo EGSnrc MC, para determinar as doses depositadas na mama contralateral. Para atingir este objetivo foi necess ario modelar o novo colimador multi-laminas High- De nition que nunca antes havia sido simulado. O modelo desenvolvido est a agora disponí vel no pacote do c odigo EGSnrc MC do National Research Council Canada (NRC). O acelerador simulado foi validado com medidas realizadas em agua e posteriormente com c alculos realizados no sistema de planeamento (TPS).As distribui ções de dose no volume alvo (PTV) e a dose nos orgãos de risco (OAR) foram comparadas atrav es da an alise de histogramas de dose-volume; an alise estati stica complementar foi realizadas usando o software IBM SPSS v20. Para o algoritmo PBC, todas as tecnicas proporcionaram uma cobertura adequada do PTV. No entanto, foram encontradas diferen cas estatisticamente significativas entre as t ecnicas, no PTV, nos OAR e ainda no padrão da distribui ção de dose pelos tecidos sãos. IMRT5 e DCART contribuem para maior dispersão de doses baixas pelos tecidos normais, mama direita, pulmão direito, cora cão e at e pelo pulmão esquerdo, quando comparados com as tecnicas tangenciais (f-IMRT e IMRT2). No entanto, os planos de IMRT5 melhoram a distribuição de dose no PTV apresentando melhor conformidade e homogeneidade no volume alvo e percentagens de dose mais baixas nos orgãos do mesmo lado. A t ecnica de DCART não apresenta vantagens comparativamente com as restantes t ecnicas investigadas. Foram tamb em identi cadas diferen cas entre os algoritmos de c alculos: em geral, o PBC estimou doses mais elevadas para o PTV, pulmão esquerdo e cora ção, do que os algoritmos de MC. Os algoritmos de MC, entre si, apresentaram resultados semelhantes (com dferen cas at e 2%). Considera-se que o PBC não e preciso na determina ção de dose em meios homog eneos e na região de build-up. Nesse sentido, atualmente na cl nica, a equipa da F sica realiza medi ções para adquirir dados para outro algoritmo de c alculo. Apesar de melhor homogeneidade e conformidade no PTV considera-se que h a um aumento de risco de cancro na mama contralateral quando se utilizam t ecnicas não-tangenciais. Os resultados globais dos estudos apresentados confirmam o excelente poder de previsão com precisão na determinação e c alculo das distribui ções de dose nos orgãos e tecidos das tecnicas de simulação de Monte Carlo usados.---------ABSTRACT:Breast cancer is the most frequent in women. Scienti c knowledge and technology have created many and di erent strategies to treat this pathology. Radiotherapy (RT) is in the actual standard guidelines for most of breast cancer treatments. However, radiation is a two-sword weapon: although it may heal cancer, it may also induce secondary cancer. The contralateral breast (CLB) is a susceptible organ to absorb doses with the treatment of the other breast, being at signi cant risk to develop a secondary tumor. New radiation related techniques, with more complex delivery strategies and promising results are being implemented and used in radiotherapy departments. However some questions have to be properly addressed, such as: Is it safe to move to complex techniques to achieve better conformation in the target volumes, in breast radiotherapy? What happens to the target volumes and surrounding healthy tissues? How accurate is dose delivery? What are the shortcomings and limitations of currently used treatment planning systems (TPS)? The answers to these questions largely rely in the use of Monte Carlo (MC) simulations using state-of-the-art computer programs to accurately model the di erent components of the equipment (target, lters, collimators, etc.) and obtain an adequate description of the radiation elds used, as well as the detailed geometric representation and material composition of organs and tissues. This work aims at investigating the impact of treating left breast cancer using di erent radiation therapy (RT) techniques f-IMRT (forwardly-planned intensity-modulated), inversely-planned IMRT (IMRT2, using 2 beams; IMRT5, using 5 beams) and dynamic conformal arc (DCART) RT and their e ects on the whole-breast irradiation and in the undesirable irradiation of the surrounding healthy tissues. Two algorithms of iPlan BrainLAB TPS were used: Pencil Beam Convolution (PBC)and commercial Monte Carlo (iMC). Furthermore, an accurate Monte Carlo (MC) model of the linear accelerator used (a Trilogy R VARIANR) was done with the EGSnrc MC code, to accurately determine the doses that reach the CLB. For this purpose it was necessary to model the new High De nition multileaf collimator that had never before been simulated. The model developed was then included on the EGSnrc MC package of National Research Council Canada (NRC). The linac was benchmarked with water measurements and later on validated against the TPS calculations. The dose distributions in the planning target volume (PTV) and the dose to the organs at risk (OAR) were compared analyzing dose-volume histograms; further statistical analysis was performed using IBM SPSS v20 software. For PBC, all the techniques provided adequate coverage of the PTV. However, statistically significant dose di erences were observed between the techniques, in the PTV, OAR and also in the pattern of dose distribution spreading into normal tissues. IMRT5 and DCART spread low doses into greater volumes of normal tissue, right breast, right lung, heart and even the left lung than tangential techniques (f-IMRT and IMRT2). However,IMRT5 plans improved distributions for the PTV, exhibiting better conformity and homogeneity in target and reduced high dose percentages in ipsilateral OAR. DCART did not present advantages over any of the techniques investigated. Di erences were also found comparing the calculation algorithms: PBC estimated higher doses for the PTV, ipsilateral lung and heart than the MC algorithms predicted. The MC algorithms presented similar results (within 2% di erences). The PBC algorithm was considered not accurate in determining the dose in heterogeneous media and in build-up regions. Therefore, a major e ort is being done at the clinic to acquire data to move from PBC to another calculation algorithm. Despite better PTV homogeneity and conformity there is an increased risk of CLB cancer development, when using non-tangential techniques. The overall results of the studies performed con rm the outstanding predictive power and accuracy in the assessment and calculation of dose distributions in organs and tissues rendered possible by the utilization and implementation of MC simulation techniques in RT TPS.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of this paper is to review the scientific literature from August 2007 to July 2010. The review is focused on more than 420 published papers. The review will not cover information coming from international meetings available only in abstract form. Fingermarks constitute an important chapter with coverage of the identification process as well as detection techniques on various surfaces. We note that the research has been very dense both at exploring and understanding current detection methods as well as bringing groundbreaking techniques to increase the number of marks detected from various objects. The recent report from the US National Research Council (NRC) is a milestone that has promoted a critical discussion on the state of forensic science and its associated research. We can expect a surge of interest in research in relation to cognitive aspect of mark and print comparison, establishment of relevant forensic error rates and statistical modelling of the selectivity of marks' attributes. Other biometric means of forensic identification such as footmarks or earmarks are also covered in the report. Compared to previous years, we noted a decrease in the number of submission in these areas. No doubt that the NRC report has set the seed for further investigation of these fields as well.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Primera conferencia. Bibliotecas y Repositorios Digitales: Gestión del Conocimiento, Acceso Abierto y Visibilidad Latinoamericana. (BIREDIAL) Mayo 9 al 11 de 2011. Bogotá, Colombia.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introducción: Los dolores y las lesiones musculo esqueléticas que sufren los trabajadores en toda la industria, se han convertido en un problema de preocupación a nivel nacional e internacional. Objetivos: Caracterizar la presencia de sintomatología osteomuscular en el personal asistencial de una IPS Materno Infantil de tercer nivel de atención en la ciudad de Bogotá, mediante la aplicación de la encuesta Nórdica, identificando su relación con el área de trabajo en el cual se desempeñan. Metodología: Se realizó un estudio descriptivo de corte transversal mediante la aplicación de la encuesta Nórdica a todo el personal asistencial diurno de una IPS Materno Infantil de III nivel de la ciudad de Bogotá que cumplieron con los criterios de inclusión y exclusión. Resultados: Del 100% de la población estudiada (n: 49), el 65,3% correspondían al género femenino y el 34.7% al masculino, la mayoría de la población laboraba menos de 12 horas. El área del cuerpo en la que manifestaron tener más sintomatología en los últimos 12 meses fue en espalda alta con una prevalencia de 46,9%. El área del cuerpo que más manifestaron les impedía trabajar en los últimos 12 meses fue en mano y muñeca derecha con una prevalencia del 6,1% y el área que manifestaron les impedía trabajar en los últimos 7 días fue en espalda alta con una prevalencia de 16,3%.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Este estudio buscó evaluar la asociación de desórdenes músculo esqueléticos en región cervical, dorsal y lumbar identificados mediante el Cuestionario Nórdico en su versión validada al español y los factores de riesgo psicosocial con el Cuestionario del contenido del trabajo (JCQ), en conductores de vehículos de carga de una empresa de transporte terrestre en Bogotá, Colombia; fue un estudio de corte transversal con la participación voluntaria de 125 conductores. Los resultados demostraron mayor prevalencia de trastornos músculo esqueléticos en región lumbar en los últimos 12 meses en el 36% de los participantes y en los últimos tres meses en región cervical con el 17.6%; la prevalencia de factores psicosociales arrojó trabajo de baja tensión en el 29.6%, trabajo activo 26.4%, trabajo con alta tensión 23.2% y trabajo pasivo con el 20.8%. El valor p fue mayor de 0,005 no hallándose asociaciones significativas de desórdenes músculo esqueléticos en región cervical, dorsal y lumbar con factores de riesgo psicosocial.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objetivo: Establecer la relación de las condiciones de trabajo y salud con los desórdenes músculo-esqueléticos (DME) en los trabajadores asistenciales y administrativos de un hospital en Sogamoso, Boyacá, en el 2013. Metodología: Se llevó a cabo un estudio descriptivo con una muestra de 90 trabajadores, correspondiente al 22%, de 405 incluyendo médicos, jefes de enfermería, auxiliar de enfermería, auxiliares administrativos y profesionales administrativos. Se aplicó una encuesta para determinar las condiciones de trabajo y salud y para el análisis de los síntomas de desorden músculo esquelético, junto con la toma de estatura y peso para calcular el índice de masa corporal. En el análisis de las variables cuantitativas se utilizó medidas de tendencia central y dispersión; para las variables cualitativas se calculó frecuencias absolutas y porcentajes. Se realizó pruebas de asociación Chi cuadrado y se estimó las medidas OR crudas y ajustadas por medio de un modelo de regresión binaria logística, con sus respectivos intervalos de confianza. Resultados: La población estuvo conformada por 78 mujeres (86.7%) y 12 hombres (13.3%), con edades entre 24 y 56 años. Los cargos más representativos fueron el Auxiliar Administrativo y el Auxiliar de Enfermería con el 35.6% (32) y 38.9% (35) respectivamente. Los síntomas de DME más frecuentes se ubicaron en la espalda y en mano afectando al 58.9% (53) y 45.6% (41) respectivamente. Según el 93.3% de los participantes, el factor de riesgo biomecánico que tiene alta influencia en los DME es la realización de movimientos repetidos. Se encontró para los Médicos un Odds Ratio (OR) 4.2; de DME, mientras que para los Auxiliares Administrativos tienen un OR 2.9 y presentan mayor posibilidad de padecer DME que un Auxiliar de Enfermería.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Número extraordinario 2006, con el título: PISA. Programa para la Evaluación Internacional de Alumnos. Resumen basado en el de la publicación

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Resumen basado en el de la publicaci??n

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Resumen basado en el de la publicaci??n

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Resumen basado en el de la publicaci??n

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Stephen Downes, investigador del Canada's National Research Council, presenta su visión personal sobre la educación y los recursos libres. Los temas principales de su presentación son: Free and Open Source Software, Open Knowledge, Education and Technology

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Feed samples received by commercial analytical laboratories are often undefined or mixed varieties of forages, originate from various agronomic or geographical areas of the world, are mixtures (e.g., total mixed rations) and are often described incompletely or not at all. Six unified single equation approaches to predict the metabolizable energy (ME) value of feeds determined in sheep fed at maintenance ME intake were evaluated utilizing 78 individual feeds representing 17 different forages, grains, protein meals and by-product feedstuffs. The predictive approaches evaluated were two each from National Research Council [National Research Council (NRC), Nutrient Requirements of Dairy Cattle, seventh revised ed. National Academy Press, Washington, DC, USA, 2001], University of California at Davis (UC Davis) and ADAS (Stratford, UK). Slopes and intercepts for the two ADAS approaches that utilized in vitro digestibility of organic matter and either measured gross energy (GE), or a prediction of GE from component assays, and one UC Davis approach, based upon in vitro gas production and some component assays, differed from both unity and zero, respectively, while this was not the case for the two NRC and one UC Davis approach. However, within these latter three approaches, the goodness of fit (r(2)) increased from the NRC approach utilizing lignin (0.61) to the NRC approach utilizing 48 h in vitro digestion of neutral detergent fibre (NDF:0.72) and to the UC Davis approach utilizing a 30 h in vitro digestion of NDF (0.84). The reason for the difference between the precision of the NRC procedures was the failure of assayed lignin values to accurately predict 48 h in vitro digestion of NDF. However, differences among the six predictive approaches in the number of supporting assays, and their costs, as well as that the NRC approach is actually three related equations requiring categorical description of feeds (making them unsuitable for mixed feeds) while the ADAS and UC Davis approaches are single equations, suggests that the procedure of choice will vary dependent Upon local conditions, specific objectives and the feedstuffs to be evaluated. In contrast to the evaluation of the procedures among feedstuffs, no procedure was able to consistently discriminate the ME values of individual feeds within feedstuffs determined in vivo, suggesting that the quest for an accurate and precise ME predictive approach among and within feeds, may remain to be identified. (C) 2004 Elsevier B.V. All rights reserved.