993 resultados para Distance spectrum technique
Dorsal root ganglionectomy for the diagnosis of sensory neuropathies. Surgical technique and results
Resumo:
Background: Inflammatory diseases stand out among sensory neuronopathies because, in their active phase, they can be treated with immunosuppressive agents. Immunosuppressive therapy may present severe adverse effects and requires previous inflammatory activity confirmation. Sensory neuronopathies are diagnosed based on clinical and EMG findings. Diagnostic confirmation and identification of inflammatory activity are based on sensory ganglion histopathological examination. We describe the surgical technique used for dorsal root ganglionectomy in patients with clinical/EMG diagnosis of sensory neuronopathies. Methods: The sensory ganglion was obtained from 15 patients through a small T7-T8 hemilaminectomy and foraminotomy to expose the C7 root from its origin to the spinal nerve bifurcation. In 6 patients, the dural cuff supposed to contain the ganglion was resected en bloc; and in 9 patients, the ganglion was obtained through a longitudinal incision of the dural cuff and microsurgical dissection from the ventral and dorsal roots and radicular arteries. All ganglia were histopathologically examined. Results: No ganglion was found in the dural cuff in 2 patients submitted to en bloc removal, and the ganglion was removed in all patients who underwent microsurgical dissection. All but 2 patients that had ganglion examination presented a neuronopathy of nerve cell loss, 3 with mononuclear inflammatory infiltrate. These patients underwent immunosuppressive therapy, and 2 of them presented clinical improvement. No surgical complications were observed. Conclusions: Microsurgical dorsal root ganglionectomy for diagnosing inflammatory sensory ganglionopathies was effective and safe. Although safe, en bloc resection of the proximal dural cuff was not effective for this purpose. (c) 2008 Published by Elsevier Inc.
Resumo:
Purpose: To describe spontaneous blink kinematics in Graves` upper eyelid retraction (UER). Methods: The magnetic search coil technique was used to record spontaneous blinks of 15 healthy subjects (aged 23-56 years, 15 eyelids) and 15 patients with Graves` UER (aged 22-62 years, 15 eyelids) during a 5-min period of video observation, and the signals were digitized at 200 Hz (12 bits). Overall, a total of 2,798 blinks were recorded for the controls and 1,860 for the patients. The distance between pupil center and upper eyelid margin in the primary position of gaze (MRD) was measured with the Image J software. Results: The blinking rate of patients was lower than that of control subjects, with a mean (+/-SEM) blinking rate (blinks/min) of 13.0 +/- 1.7 for patients and of 20.0 +/- 2.1 for the controls (t = 2.58, P = 0.016). There were no statistically significant differences in blink amplitude between controls (22.7 +/- 3.1 degrees) and Graves` patients (24.7 +/- 3.3 degrees). However, while only 22% of the blinks performed by controls were smaller than MRD, this rate was 78% for patients. In addition, in blinks larger than 25, patients showed lower down-phase velocity than controls. Conclusions: Patients with Graves` UER show reduced blinks rates and abnormal blink kinematics, which might be related to the development of exposure keratitis in this disease.
Resumo:
Purpose: Bone maintenance after mandibular reconstruction with autogenous iliac crest may be disappointing due to extensive resorption in the long term. The potential of the guided-bone regeneration (GBR) technique to enhance the healing process in segmental defects lacks comprehensive scientific documentation. This study aimed to investigate the influence of polylactide membrane permeability on the fate of iliac bone graft (BG) used to treat mandibular segmental defects. Materials and Methods: Unilateral 10-mm-wide segmental defects were created through the mandibles of 34 mongrel dogs. All defects were mechanically stabilized, and the animals were divided into 6 treatment groups: control, BG alone, microporous membrane (poly L/DL-lactide 80/20%) (Mi); Mi plus BG; microporous laser-perforated (15 cm(2) ratio) membrane (Mip), and Mip plus BG. Calcein fluorochrome was injected intravenously at 3 months, and animal euthanasia was carried out at 6 months postoperatively. Results: Histomorphometry showed that BG protected by Mip was consistently related to larger amounts of bone compared with other groups (P <= .0001). No difference was found between defects treated with Mip alone and BG alone. Mi alone rendered the least bone area and reduced the amount of grafted bone to control levels. Data from bone labeling indicated that the bone formation process was incipient in the BG group at 3 months postoperatively regardless of whether or not it was covered by membrane. In contrast, GBR with Mip tended to enhance bone formation activity at 3 months. Conclusions: The use of Mip alone could be a useful alternative to BG. The combination of Mip membrane and BG efficiently delivered increased bone amounts in segmental defects compared with other treatment modalities. (C) 2008 American Association of Oral and Maxillofacial Surgeons.
Resumo:
The aim of this paper was to verify whether AC biosusceptometry (ACB) is suitable for monitoring gastrointestinal (GI) contraction directly from smooth muscle in dogs, comparing with electrical recordings simultaneously. All experiments were performed in dogs with magnetic markers implanted under the serosa of the right colon and distal stomach, and their movements were recorded by ACB. Monopolar electrodes were implanted close to the magnetic markers and their electric potentials were recorded by electromyography (EMG). The effects of neostigmine, hyoscine butylbromide and meal on gastric and colonic parameters were studied. The ACB signal from the distal stomach was very similar to EMG; in the colonic recordings, however, within the same low-frequency band, ACB and EMG signals were characterized by simultaneity or a widely changeable frequency profile with time. ACB recordings were capable of demonstrating the changes in gastric and colonic motility determined by pharmacological interventions as well as by feeding. Our results reinforce the importance of evaluating the mechanical and electrical components of motility and show a temporal association between them. ACB and EMG arecomplementary for studying motility, with special emphasis on the colon. ACB offers an accurate method for monitoring in vivo GI motility.
Resumo:
Twenty-five extended-spectrum beta-lactamase (ESBL)-producing Escherichia coli clinical isolates from Rio de Janeiro, Brazil were characterized by isoelectric focusing, PCR and sequencing of bla(ESBL) genes, plasmid-mediated quinolone resistance determinants, phylogenetic groups, replicon typing, pulsed-field electrophoresis, and multilocus sequencing typing. Twenty-three (92%) ESBL-producing E. coli isolates were positive for bla(CTX-M) genes, aac(6`)-lb-cr, and qnrB. Genetic relatedness of ESBL producers clustered seven (28%) CTX-M-15-producing isolates as sequence type (ST) 410, clonal complex (CC) 23, and two (8%) as clone O25-ST131. Our results illustrate the predominance of phylo-group A (52%), ST410 (CC 23) and CTX-M-15 among ESBL-producing E. coli isolates from hospitals in Rio de Janeiro.
Resumo:
The tissue microarray (TMA) technique allows multiple tissue samples in a single block. Commercial adhesive tape is used to avoid the loss of tissue samples during the immunostaining process. Few reports exist in the literature comparing the use of these adhesive tapes to other adhesive techniques. The objective of this study was to compare loss of sections adhered to slides using commercial adhesive tapes versus using silanized only slides. TMA was constructed with varying tissues using a fixed-base device (Beecher Instruments), placing 108 cylinders of 1 mm diameter in duplicate, spaced 1.2 mm apart. Section of 4 mu m were cut from the TMA block and adhered to 30 silanized slides and 30 commercial glass slides using adhesive tape, according to manufacturer`s recommendations. Vimentin immunoexpression was evaluated by immunohistochemistry. Antigenic recovery was realized in citrate buffer using a microwave oven. Cylinder loss in the immunohistochemical process was quantified and expressed as: total (>80%), almost complete (75-79%), or partial (50-74%). The commercial adhesive tape group presented lesser total loss (1.1 versus 6.4%), almost complete loss (2.2 versus 3.5%), and partial loss (2.1 versus 3.8%) than the silanized slide group (ANOVA, P < 0.05). The sum of total and almost complete losses in the silanized slide group was 9.9%, greater than the losses in slides using commercial adhesive tapes (3.3%) and less than reported and considered acceptable in the literature (10-30%). In conclusion, the use of silanized only slides presents very satisfactory results, requires less training, and reduces costs significantly, thus justifying their use in research.
Resumo:
Adrenocortical tumors (ACT) are rare neoplasms of the adrenal glands accounting for 0.2% of all pediatric cancers. However, the incidence of ACT in South Brazilian children is 10 to 15 times greater than the worldwide incidence. Comparative genomic hybridization studies have revealed the presence of a high degree of chromosomal instability in ACT. We evaluated 16 ACT, 8 of them carcinomas and 8 adenomas. The presence of changes in DNA copy numbers was determined by comparative genomic hybridization, and the findings were validated by real-time polymerase chain reaction on the basis of IGF-II gene expression. The adenomas showed a mean of 19.7 imbalances per case, with the most frequent gain and loss being 4p15.1-p15.3 and 20p11.2-p13.2, respectively. The carcinomas presented with a mean of 35.5 imbalances per case, with the more frequent gain being 2q14.1-q24.3 and the more frequent losses being 3q21-q26.2, 20q12-qter, and 22q11.2-q13.3. The most frequent imbalances in both adenomas and carcinomas were gains of 1p21-p31.2, 2p12-p21 and loss of 20p11.2-p12. The expression of IGF-II mRNA (11p15.5) was higher in samples that presented with a gain of this region. It has been established that great genomic instability exists in pediatric ACT.
Resumo:
Purpose: The Gow-Gates technique is said to have several advantages over traditional techniques to achieve mandibular nerve anesthesia; however, its routine use is quite limited, mainly due to complications during visual alignment of reference landmarks. The purpose of this study was to verify the validity and accuracy of a new method to reach the injection site. Material and Methods: Fifteen magnetic resonance images were captured. Distances from the ideal injection point in the condylar neck (puncture ideal) to the injection points located in the a and 0 plane intersection (Puncture Gow-Gates and puncture modified) were measured and compared. Results: Positive and significant (P <= .003) Pearson correlations between landmarks and injection points confirmed the validity of the modified technique. Paired t test showed that the segment line puncture ideal-puncture modified, 5.17 mm, was 3 times shorter (P < .001) than the segment line puncture ideal-puncture Gow-Gates, 17.91 mm. As calculated by linear regression, establishing the injection point of the modified technique depended only on the anteroposterior and lateromedial condyle positions. Conclusions: The modified technique proved to be valid and precise and has a determined and an effective injection site. (C) 2009 American Association of Oral and Maxillofacial Surgeons J Oral Maxillofac Surg 67:2609-2616, 2009
Resumo:
Introduction: There is ongoing debate regarding the ideal sequence, volume, and concentration of irrigants, length of time for irrigation, and irrigation technique to achieve debridement of the root canal system. The aim of this study was to verify the impact of the final rinse technique on smear layer removal ability of 17% ethylenediaminetetraacetic acid (EDTA). Methods: Sixteen single-rooted human teeth were instrumented and divided into 2 groups at the final rinse step according to the following final rinse techniques used: continuous rinse group, continuous rinse with EDTA during 3 minutes, and rinse and soaking group, rinse with 1 mL of EDTA, soaking of the canal for 2 minutes and 30 seconds, and rinse completion with the remaining 4 mL for 30 seconds. The specimens were split lengthwise and observed under scanning electron microscope. Results: Data were analyzed with Kruskal-Wallis and Dunn tests. The continuous rinse group presented more debris-free surfaces when compared with the rinse and soaking group (P <. 01). When the root canal areas were compared within the groups, no statistical differences were found (P > .05). Conclusions: It can be concluded that a continuous rinse with 5 mL of EDTA for 3 minutes can more efficiently remove the smear layer from root canal walls. (J Endod 2010;36:512-514)
Resumo:
Dentin bonding performed with hydrophobic resins using ethanol-wet bonding should be less susceptible to degradation but this hypothesis has never been validated. Objectives. This in vitro study evaluated stability of resin-dentin bonds created with an experimental three-step BisGMA/TEGDMA hydrophobic adhesive or a three-step hydrophilic adhesive after one year of accelerated aging in artificial saliva. Methods. Flat surfaces in mid-coronal dentin were obtained from 45 sound human molars and randomly divided into three groups (n = 15): an experimental three-step BisGMA/TEGDMA hydrophobic adhesive applied to ethanol (ethanol-wet bonding-GI) or water-saturated dentin (water-wet bonding-GII) and Adper Scotchbond Multi-Purpose [MP-GIII] applied, according to manufacturer instructions, to water-saturated dentin. Resin composite crowns were incrementally formed and light-cured to approximately 5 mm in height. Bonded specimens were stored in artificial saliva at 37 degrees C for 24h and sectioned into sticks. They were subjected to microtensile bond test and TEM analysis immediately and after one year. Data were analyzed with two-way ANOVA and Tukey tests. Results. MP exhibited significant reduction in microtensile bond strength after aging (24 h: 40.6 +/- 2.5(a); one year: 27.5 +/- 3.3(b); in MPa). Hybrid layer degradation was evident in all specimens examined by TEM. The hydrophobic adhesive with ethanol-wet bonding preserved bond strength (24 h: 43.7 +/- 7.4(a); one year: 39.8 +/- 2.7(a)) and hybrid layer integrity, with the latter demonstrating intact collagen fibrils and wide interfibrillar spaces. Significance. Coaxing hydrophobic resins into acid-etched dentin using ethanol-wet bonding preserves resin-dentin bond integrity without the adjunctive use of MMPs inhibitors and warrants further biocompatibility and patient safety`s studies and clinical testing. (C) 2009 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
Resumo:
Purpose: To evaluate the effect of light guide distance and the different photoactivation methods on the degree of conversion (DC) and microleakage of a composite. Methods and Materials: Three photoactivation protocols (600mW/cm(2) x 40 seconds; 400 mW/cm(2) x 60 seconds or 200 mW/cm(2) x 20 seconds, followed by 500 mW/cm(2) X 40 seconds) and three distances from the light source (0, 3 or 7 mm) were tested. Cylindrical specimens (5 nun diameter; 2 mm tall; n=3) were prepared for the DC test (FT-Raman). Class V cavities were made in 90 bovine incisors to conduct the microleakage test. The specimens were conditioned for 15 seconds with phosphoric acid (37%), followed by application of the adhesive system Prime & Bond NT (Dentsply/Caulk). The preparations were restored in bulk. The specimens were stored for 24 hours in distilled water (37 degrees C) before being submitted to the silvernitrate microleakage protocol. The restorations were sectioned and analyzed under 25x magnification. Results: Statistical analyses (two-way ANOVAs and Tukey test, alpha=0.05) found significance only for the factor distance (p=0.015) at the top of the composite for the DC test. Conversion was statistically lower for the 7 mm groups compared to the 0 and 3 mm groups, which were equivalent to each other. At the bottom of the specimens, none of the factors or interactions was significant (p<0.05). The Kruskal-Wallis test showed that, in general, the soft-start method led to lower microleakage scores when compared to the continuous modes, mainly when associated with a distancing of 7 mm (p<0.01). With the exception of specimens irradiated with 400mW/cm(2) that did not demonstrate variations on scores for the distances tested, higher microleakage was observed for shorter distances from the light source. Conclusions: Soft-start methods may reduce microleakage when the light guide distancing provides a low level of irradiance, which also causes a discrete reduction in the DC.
Resumo:
Composite resins can be used to improve the esthetics of the smile at a low cost and with relatively high clinical performance, The aim of this article was to describe an approach to restore and enhance the esthetic appearance of the anterior dentition through vital tooth whitening and the direct layering of composite resin during predictable esthetic procedures, (Quintessence lot 2011;42205-211)
Resumo:
Objective. The aim was to compare the percentage and depth of sealer penetration into dentinal tubules during obturation using Sealer 26, GuttaFlow, or Sealapex in root canals filled with the lateral compaction technique. Study design. Thirty root canals filled with the lateral compaction technique using GuttaFlow (n = 10), Sealapex (n = 10), or Sealer 26 (n = 10) were analyzed using confocal microscopy. The teeth were sectioned at 3 and 5 mm from the apex, and statistical analyses was performed using analysis of variance-Tukey test (P < .05). Results. Sealapex showed the deepest sealer penetration at both levels evaluated (P < .05). No statistically significance was found between Sealer 26 and GuttaFlow at the 3 mm and 5 mm levels. No statistical significance was found in the percentage of penetration around the root canal wall among the 3 sealers evaluated at both levels. Conclusions. Although Sealapex displayed deeper penetration into the dentinal tubules there was no difference in the percentage of adaptation to the root canal walls among the 3 sealers evaluated. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2009; 108: 450-457)