340 resultados para Extracorporeal shockwave lithotripsy


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The recently introduced rabbit blood shunt subarachnoid haemorrhage model is based on the two standard procedures of subclavian artery cannulation and transcutaneous cisterna magna puncture. An extracorporeal shunt placed in between the arterial system and the subarachnoid space allows examiner-independent SAH in a closed cranium. Despite its straightforwardness, it is worth examining some specific features and characteristics of the model. We outline technical considerations to successfully perform the model with minimal mortality and morbidity. In addition, we discuss outcome measures, advantages and limitations, and the applicability of the model for the study of early brain injury and delayed cerebral vasospasm after SAH.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND The activation of multiple pro- and anti-inflammatory mediators is a key feature in the pathophysiology of sepsis. Many of these mediators may directly contribute to organ dysfunction and determine disease severity. So far our ability to modulate these upregulated mediator pathways is very limited. Therefore the adsorption of such mediators via an extracorporeal circuit may be a beneficial intervention during sepsis. OBJECTIVES Recent technical innovations have made this intervention feasible. Both systems for exclusive mediator adsorption and for adsorption beside a conventional renal replacement therapy are now available. Some of the membranes can adsorb a broad range of mediators by rather unspecific binding, whereas others specifically adsorb endotoxin or mediators. DISCUSSION Whilst biochemical efficacy could be demonstrated by some of the systems, controlled and randomized studies demonstrating improved clinical endpoints are still lacking. Therefore the use of such therapies outside clinical studies cannot yet be recommended.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND The Perceval (Sorin Group, Milan, Italy) is a self-anchoring sutureless aortic valve prosthesis. We report the short- to midterm results of combined aortic valve replacement (AVR) with concomitant procedures in elderly patients undergoing operation as part of 3 consecutive prospective multicenter European studies. METHODS From April 2007 to February 2013, 243 patients (mean age, 79.7 ± 5.1 years; female patients, 61%; median EuroSCORE, 9%) underwent AVR with concomitant procedures. The concomitant procedures were coronary artery bypass grafting (CABG) (182 cases), septal myectomy (21 cases), CABG + other procedures (18 cases), and 22 other procedures. Primary and secondary end points included implant feasibility and safety (for mortality and morbidity) and efficacy (New York Heart Association [NYHA] class improvement and hemodynamic results) of the prosthesis at the different follow-up periods. Data were expressed as mean ± standard deviation. Kaplan-Meier analysis was performed for survival analysis. RESULTS Mean aortic cross-clamp and extracorporeal circulation (ECC) times were 50.7 ± 22.8 minutes and 78.9 ± 32.3 minutes, respectively. Thirty-day mortality was 2.1%. Mean postoperative gradient and effective orifice area were 10.1 ± 4.7 mm Hg and 1.5 ± 0.4 cm(2) and 8.9 ± 5.6 mm Hg and 1.6 ± 0.4 cm(2), respectively, at 1 year. There were early explantations, 4 of which resulted from paravalvular leaks. One additional valve explantation resulted from aortic root bleeding, probably caused by excessively extensive decalcification. In the late period, there was 1 mild paravalvular leak and no intravalvular insufficiency. No migration, dislodgement, or degeneration of the valve occurred during follow-up. Median follow-up was 444 days. CONCLUSIONS These trials confirm the safety and efficacy of the Perceval sutureless aortic valve, especially in elderly patients requiring AVR + concomitant procedures. In this patient group, sutureless valves may be advantageous compared to transcatheter valve implantations as concomitant procedures other than percutaneous coronary artery angioplasty are not always possible in the latter.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVES Oxygenation of blood and other physiological solutions are routinely required in fundamental research for both in vitro and in vivo experimentation. However, very few oxygenators with suitable priming volumes (<2-3 ml) are available for surgery in small animals. We have designed a new, miniaturized membrane oxygenator and investigated the oxygen-transfer performance using both buffer and blood perfusates. METHODS The mini-oxygenator was designed with a central perforated core-tube surrounded by parallel-oriented microporous polypropylene hollow fibres, placed inside a hollow shell with a lateral-luer outlet, and sealed at both extremities. With this design, perfusate is delivered via the core-tube to the centre of the mini-oxygenator, and exits via the luer port. A series of mini-oxygenators were constructed and tested in an in vitro perfusion circuit by monitoring oxygen transfer using modified Krebs-Henseleit buffer or whole porcine blood. Effects of perfusion pressure and temperature over flows of 5-60 ml × min(-1) were assessed. RESULTS Twelve mini-oxygenators with a mean priming volume of 1.5 ± 0.3 ml were evaluated. With buffer, oxygen transfer reached a maximum of 14.8 ± 1.0 ml O2 × l(-1) (pO2: 450 ± 32 mmHg) at perfusate flow rates of 5 ml × min(-1) and decreased with an increase in perfusate flow to 7.8 ± 0.7 ml ml O2 × l(-1) (pO2: 219 ± 24 mmHg) at 60 ml × min(-1). Similarly, with blood perfusate, oxygen transfer also decreased as perfusate flow increased, ranging from 33 ± 5 ml O2 × l(-1) at 5 ml × min(-1) to 11 ± 2 ml O2 × l(-1) at 60 ml × min(-1). Furthermore, oxygen transfer capacity remained stable with blood perfusion over a period of at least 2 h. CONCLUSIONS We have developed a new miniaturized membrane oxygenator with an ultra-low priming volume (<2 ml) and adequate oxygenation performance. This oxygenator may be of use in overcoming current limitations in equipment size for effective oxygenation in low-volume perfusion circuits, such as small animal extracorporeal circulation and ex vivo organ perfusion.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Die Nierenersatztherapie ist eine der erfolgreichsten Geschichten eines künstlichen Organersatzes. Der vorliegende Artikel beschreibt die wichtigsten Schritte in der Evolution zur modernen Therapie mit Peritonealdialyse und Hämodialyse. Aktuelle Fragen im Bereich der Nierenersatztherapie werden diskutiert und zukünftige Entwicklungen aufgezeigt. Dem Patienten stehen heute diverse Therapiemöglichkeiten offen. Allerdings nur, wenn er mindestens ein halbes Jahr vor der Notwendigkeit eines Therapiebeginns die für ihn ideale Therapieform auswählen kann. Verspätete Zuweisungen und die Notwendigkeit eines akuten Dialysebeginns führen nicht nur zu einer erhöhten Mortalität, sondern auch dazu, dass eine präemptive Lebendnierentransplantation verunmöglicht wird. Zudem bleiben diese Patienten in der Regel im Dialysezentrum und können für eine Heimbehandlung, sei es nun in Form einer Peritonealdialyse oder Heimhämodialyse, nicht mehr motiviert werden.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Gebiet: Chirurgie Biomedizintechnik Biophysik Transplantationsmedizin Kardiologie Abstract: OBJECTIVES: – Oxygenation of blood and other physiological solutions are routinely required in fundamental research for both in vitro and in vivo experimentation. However, very few oxygenators with suitable priming volumes (<2-3 ml) are available for surgery in small animals. We have designed a new, miniaturized membrane oxygenator and investigated the oxygen-transfer performance using both buffer and blood perfusates. – – METHODS: – The mini-oxygenator was designed with a central perforated core-tube surrounded by parallel-oriented microporous polypropylene hollow fibres, placed inside a hollow shell with a lateral-luer outlet, and sealed at both extremities. With this design, perfusate is delivered via the core-tube to the centre of the mini-oxygenator, and exits via the luer port. A series of mini-oxygenators were constructed and tested in an in vitro perfusion circuit by monitoring oxygen transfer using modified Krebs-Henseleit buffer or whole porcine blood. Effects of perfusion pressure and temperature over flows of 5-60 ml × min(-1) were assessed. – – RESULTS: – Twelve mini-oxygenators with a mean priming volume of 1.5 ± 0.3 ml were evaluated. With buffer, oxygen transfer reached a maximum of 14.8 ± 1.0 ml O2 × l(-1) (pO2: 450 ± 32 mmHg) at perfusate flow rates of 5 ml × min(-1) and decreased with an increase in perfusate flow to 7.8 ± 0.7 ml ml O2 × l(-1) (pO2: 219 ± 24 mmHg) at 60 ml × min(-1). Similarly, with blood perfusate, oxygen transfer also decreased as perfusate flow increased, ranging from 33 ± 5 ml O2 × l(-1) at 5 ml × min(-1) to 11 ± 2 ml O2 × l(-1) at 60 ml × min(-1). Furthermore, oxygen transfer capacity remained stable with blood perfusion over a period of at least 2 h. – – CONCLUSIONS: – We have developed a new miniaturized membrane oxygenator with an ultra-low priming volume (<2 ml) and adequate oxygenation performance. This oxygenator may be of use in overcoming current limitations in equipment size for effective oxygenation in low-volume perfusion circuits, such as small animal extracorporeal circulation and ex vivo organ perfusion. – – © The Author 2015. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background In patients with autoimmune diseases associated with antiphospholipid antibodies, precise management of anticoagulation during extracorporeal circulation (ECC) is complicated. It was the aim of the present study to determine whether antifactor Xa (aXa) activity is useful in guiding heparin therapy during ECC. Methods In 15 patients undergoing cardiac surgery, anticoagulation with unfractionated heparin (UFH) and its reversal with protamine were guided using activated clotting time (ACT) (>400 second during ECC; ≤100 second for UFH reversal). For each ACT, the corresponding aXa activity levels were measured. Results A total of 144 blood samples were obtained. ACT and aXa activity were significantly correlated (r = 0.771, p< 0.0001, Spearman rank-order correlation). Using receiver operating characteristic curve (ROC) analyses, the cutoffvalues for aXa activity were 1.14 IU/mL (area under the ROC curve [AUC]: 0.89; inaccuracy rate: 9.4%) to predict ACT > 400 seconds and 0.55 IU/mL (AUC: 0.85; inaccuracy rate: 13.3%) for ACT ≤ 100 seconds. Conclusion AXa activity is strongly correlated with ACT, and therefore may be feasible for managing anticoagulation with UFH during ECC.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

La comisaria de la última edición de la documenta de Kassel en 2012, Carolyn Christov-Bakargiev, resumió su planteamiento expositivo con el concepto de “no tener concepto”. Este posicionamiento se puede interpretar como una contradicción o como la voluntad de superar el marco discursivo. Entender la materialización de esta proposición en la dOCUMENTA (13) es un viaje al centro del individuo, construido en torno a la necesidad de ser o de tener una voz, y el anhelo de no ser o evitar agotarse en esa voz. La dOCUMENTA (13) da por hecho el colapso de la civilización occidental y se plantea como un espacio para propiciar el acontecimiento de su recuperación. El lugar en sí adquiere unas dimensiones metafísicas; límite entre el principio y el fin de la existencia. Ese territorio se puede recorrer desde la experiencia del visitante o desde la idea de los organizadores del evento. Para comprenderse mejor, la interpretación del usuario se desdobla, en lo que se percibe inmediatamente y lo que se piensa después. El primer recorrido es la experiencia estética extra-corporal de un no-individuo. El segundo camino es la invención de un sujeto que contempla cómo el ser que habita un mundo racional desaparece en un mundo especular e intenta encontrarse en el origen. El último itinerario es la expresión propia de la dOCUMENTA (13). Lo que dice de sí misma es la justificación del equipo curatorial; lo que siente es la superación de su discurso en el cuerpo del escritor Vila-Matas; lo que es lo encuentra en su memoria. ABSTRACT The commissioner of the 2012 edition of dOCUMENTA in Kassel, Carolyn Christov-Bakargiev, summed up her approach to exhibiting with the concept of "not having a concept". This standpoint could be viewed as a contradiction or as evidence of the will to overcome the discursive framework. Understanding the materialisation of this proposition at dOCUMENTA (13) is a journey to the centre of the individual, built around the need to be or to have a voice, and the desire to not be or to avoid exhausting oneself in that voice. The collapse of Western civilization serves as a starting point for dOCUMENTA (13), and the exhibition is conceived as a space for promoting its recovery. The venue itself acquires metaphysical dimensions; the boundary between the beginning and the end of existence. The exhibition can be viewed from different standpoints: through the experience of the visitor or through the idea of the organisers of the event, whilst a personal visit unfolds to provide a deeper understanding; that which is perceived immediately and that which is unveiled through subsequent reflection. The first viewpoint represents the aesthetic, extracorporeal experience of a non-individual. The second is the invention of a subject that contemplates how the being that inhabits the rational world disappears into the world of reflections and tries to return to the origin. The final itinerary is the expression of dOCUMENTA (13) itself. What it says of itself is the justification of the curatorial team; what it feels is the surpassing of its discourse in the body of the writer Vila-Matas; what it is can be found in its memory.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Efficient and safe heparin anticoagulation has remained a problem for continuous renal replacement therapies and intermittent hemodialysis for patients with acute renal failure. To make heparin therapy safer for the patient with acute renal failure at high risk of bleeding, we have proposed regional heparinization of the circuit via an immobilized heparinase I filter. This study tested a device based on Taylor-Couette flow and simultaneous separation/reaction for efficacy and safety of heparin removal in a sheep model. Heparinase I was immobilized onto agarose beads via cyanogen bromide activation. The device, referred to as a vortex flow plasmapheretic reactor, consisted of two concentric cylinders, a priming volume of 45 ml, a microporous membrane for plasma separation, and an outer compartment where the immobilized heparinase I was fluidized separately from the blood cells. Manual white cell and platelet counts, hematocrit, total protein, and fibrinogen assays were performed. Heparin levels were indirectly measured via whole-blood recalcification times (WBRTs). The vortex flow plasmapheretic reactor maintained significantly higher heparin levels in the extracorporeal circuit than in the sheep (device inlet WBRTs were 1.5 times the device outlet WBRTs) with no hemolysis. The reactor treatment did not effect any physiologically significant changes in complete blood cell counts, platelets, and protein levels for up to 2 hr of operation. Furthermore, gross necropsy and histopathology did not show any significant abnormalities in the kidney, liver, heart, brain, and spleen.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Trabalho Final do Curso de Mestrado Integrado em Medicina, Faculdade de Medicina, Universidade de Lisboa, 2014

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Trabalho Final do Curso de Mestrado Integrado em Medicina, Faculdade de Medicina, Universidade de Lisboa, 2014

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Trabalho Final do Curso de Mestrado Integrado em Medicina, Faculdade de Medicina, Universidade de Lisboa, 2014

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Recently very potent extracorporeal cholesterol-lowering treatment options have become available for patients with hypercholesterolemia. LDL immunoapheresis treatment selectively removes LDL and lipoprotein(a) from the circulation. Since LDL is the major carrier of lipophilic antioxidants in plasma, the purpose of the present study was to assess the effects of a single LDL apheresis treatment on plasma concentrations of tocopherols (alpha- and gamma-tocopherol) and carotenoids (alpha- and beta-carotene, zeaxanthin, cryptoxanthin, canthaxanthin, lycopene, and retinol). Plasma antioxidant concentrations were determined by HPLC in 7 patients with familial hypercholesterolemia before and after LDL immunoapheresis treatment. Plasma concentrations of both alpha- and gamma-tocopherol and the different carotenoids were significantly reduced by LDL apheresis. However, when standardized for cholesterol to adjust for cholesterol removal, alpha- and gamma-tocopherol, retinol, and the more polar carotenoids lutein and zeaxanthin increased in response to apheresis treatment, while the more unpolar carotenoids such as beta-carotene and lycopene did not change. These data demonstrate that a single LDL immunoapheresis treatment affects tocopherols and individual carotenoids differently. This may be explained by differences in chemical structure and preferential association with different lipoproteins. These results further imply that tocopherols, lutein, zeaxanthin, and retinol, are associated in part with lipoproteins and other carriers such as retinol-binding protein that are not removed during apheresis treatment. (C) 2004 Wiley-Liss, Inc.