1000 resultados para Efeitos heterogêneos


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tomatoes are one of the most important vegetable crops grown in Brazil and are among the crops that have one of the highest post-harvest losses indexes in the country. The present work aimed at evaluating impact damage observed in packing lines of fresh tomatoes as well as to determine, under laboratory conditions, quality alterations of tomato fruits submitted to impact damage in different surface types. Critical points evaluation was accomplished using an instrumented sphere. Critical transference points found showed variations in acceleration levels from 30 to 129 G (m s-2). Tests carried out under laboratory conditions showed that padded surfaces reduced up to 31% impact damage. Incidence of severe internal physical damage was evaluated by a subjective scale and increased by 79% on hard surfaces for the highest fall drop. On the other hand, it was observed an effective reduction in physical damage on fruits when padded surfaces were used. When a 10-cm drop was performed, the maximum reduction measured was 10% for hard surfaces and 5% for previously padded surfaces. For quality parameters, it was observed for high drops on hard surfaces, highest values for weight loss, total acidity, lower values for vitamin C and Soluble Solids.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Handball is a sport that demands endurance associated with fast and powerful actions such as jumps, blocks, sprints and throws. The aim of this study was to evaluate the effects of a 38-week systematic physical training applied to a women's under 21 handball team on upper and lower limb power, 30m sprints speed and endurance. The periodization applied was an adaptation of the Verkhoshansky theory, and aimed at two performance peaks during the season with six data collections. The median and range values for three kg medicine ball throwing was: 2.98m (2.15-3.50); 2.84m (2.43-3.20); 2.90m (2.60-3.38); 3.10 (2.83-3.81); 2.84 (2.55-3.57) and 3.34 (2.93-3.83). Regarding the three-pass running test: 5.60m (4.93-6.58); 5.37m (5.04-6.38); 5.36m (4.93-6.12); 5.65m (4.80-6.78); 5.63m (5.00-6.40) and 5.83m (5.14-6.05). Regarding the 30-m sprint test: 5.8m/s (5.45-6.44); 6,64 m/s (6,24-7,09); 5.65m/s (5.17-5.95); (there was not IV moment for this test); 6.19 m/s (5.57-6.26) and 5.83 (5.14-6.05).Regarding the 30-m sprint endurance test until 10% decrease: 4 sprints (4-6); 5 sprints (4-9); 4,5 sprints (4-16); (there was not IV moment for this test); 6 sprints (4-12) and 5 sprints (4-5). Significant differences (p<0.05) were observed in three kg medicine ball throwing and three-pass running tests at least in one of the performance peak planned, with no significant differences in 30-m sprint speed or endurance tests. The applied physical training was efficient at improving the specific physical fitness in the performance peaks, as well as giving support for better physical training adjustment for the upcoming season.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A wild strain of Streptococcus thermophilus isolated from pasteurized milk was evaluated using an experimental model with respect to its adhesion onto stainless steel surfaces and its behaviour when submitted to cleansing and sanification. In milk, the adhesion of the microorganism on to stainless steel surfaces was studied after 6 hours of contact at 45°C with agitation, and after a cleansing process involving cleaning stages with alkaline and acid detergents followed by sanification, in order to evaluate the resistance of the adhered cells. The microorganism adhered to stainless steel surfaces producing a cell load of 10(4) CFU/cm². After alkaline cleansing, no adhered cells were detected but 6 CFU/cm² were still detected on the surfaces after acid cleansing. Cleansing, followed by sanification with sodium hypochlorite, was sufficient to reduce the load of wild S. thermophilus on the stainless steel surfaces to non-detectable levels. The experimental model proved adequate for the study indicating that the wild microorganism S. thermophilus produces biofilms on stainless steel surfaces. Alkaline cleansing remove more that 99.9% of the adhered cells. The few cells adhered on the surface are removed by acid cleansing demonstrating the need to use different steps and types of detergent for efficient cleansing. The best results for the removal of these biofilms are obtained by using alkaline cleansing followed by acid cleaning, this procedure being more efficient when complemented by sanification with sodium hypochlorite.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To study the effects of pupillary constriction on frequency doubling perimetry in a group of normal subjects. Methods: Eighteen healthy volunteers participated in the study. Only one eye per patient (right eye) underwent frequency doubling perimetry (Full Threshold C-20 strategy). For the second session, one drop of 2% pilocarpine was administered to the volunteers' right eye and the examination was repeated after 60 minutes. Results: Sixty minutes after administration of 2% pilocarpine, there was a significant reduction of the pupillary diameter from 4.22 ± 0.17 mm to 1.55 ± 0.51 mm (p<0.05). There was a significant reduction of the mean retinal sensibility after pupillary constriction. The threshold sensitivity of the central 5º worsened by 5.67 ± 2.49 dB; the area between 2.5º and 10º worsened by 4.49 ± 2.73 dB; and the area between 10º and 20º worsened by 5.10 ± 3.55 dB (p<0.01). A reduction of 4.06 ± 2.67 dB was observed in the mean deviation, as well as an increase of 0.64 ± 0.94 dB in the pattern standard deviation (p<0.01). No differences were observed regarding the number of fixation losses, false-positive and false-negatives responses, and duration of the examination. Conclusion: Changes in pupillary diameter may produce significant declines in threshold sensitivities of the 20º visual field tested by frequency doubling perimetry. These results suggest that is important to maintain a constant pupillary diameter in seriate examinations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Universidade Estadual de Campinas . Faculdade de Educação Física

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Universidade Estadual de Campinas . Faculdade de Educação Física

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Universidade Estadual de Campinas . Faculdade de Educação Física

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Universidade Estadual de Campinas . Faculdade de Educação Física

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Universidade Estadual de Campinas. Faculdade de Educação Física

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Universidade Estadual de Campinas. Faculdade de Educação Física

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Universidade Estadual de Campinas . Faculdade de Educação Física

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Universidade Estadual de Campinas. Faculdade de Educação Física

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Universidade Estadual de Campinas . Faculdade de Educação Física

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Universidade Estadual de Campinas . Faculdade de Educação Física