894 resultados para Ring opening metathesis polymerization


Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report experimental studies of metastable chaos in the far-infrared ammonia ring: laser. When the laser pump power is switched from above chaos threshold to slightly below, chaotic intensity pulsations continue for a varying time afterward before decaying to either periodic or cw emission. The behavior is in good qualitative agreement with that predicted by the Lorenz equations, previously used to describe this laser. The statistical distribution of the duration of the chaotic transient is measured and shown to be in excellent agreement with the Lorenz equations in showing a modified exponential distribution. We also give a brief numerical analysis and graphical visualization of the Lorenz equations in phase space illustrating the boundary between the metastable chaotic and the stable fixed point basins of attraction. This provides an intuitive understanding of the metastable dynamics of the Lorenz equations and the experimental system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Silastic rings are used in gastric bypass procedures for the treatment of obesity, but ring slippage may lead to gastric pouch outlet stenosis (GPOS). Conventional management has been ring removal through abdominal surgery. Objective: To describe a novel, safe, minimally invasive, endoscopic technique for the treatment of GPOS caused by ring slippage after gastric bypass. Design: Case series. Setting: Federal University of Pernambuco and sao Paulo University. Patients: This study involved 39 consecutive patients who-were screened for inclusion. Intervention: Endoscopic dilation with an achalasia balloon. Main Outcome Measurements: Technical success and safety of the procedure. Results: Among the 39 patients, 35 underwent endoscopic dilation at the ring slippage site for the relief of GPOS. The 4 patients who did not undergo endoscopic dilation underwent surgical removal of the ring, based on the exclusion criteria. The endoscopic approach was successful in 1 to 4 sessions in 100% of cases with radioscopic control (n = 12). The duration of the procedures ranged from 5 to 30 minutes, and the average internment was 14.4 hours. Dilation promoted either rupture (65.7%) or stretching (34.3%) of the thread within the ring, thereby increasing the luminal diameter of the GPOS. Complications included self-limited upper digestive tract hemorrhage (n = 1) and asymptomatic ring erosion (n = 4). There were no recurrences of obstructive symptoms during the follow-up period (mean of 33.3 months). Limitations: This was not a randomized, comparison study, and the number of patients was relatively small. Conclusion: The technique described promotes the relief of GPOS with low overall morbidity and avoids abdominal reoperation for ring removal. (Gastrointest Endosc 2010;72:44-9.)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Bariatric surgery before pregnancy may help prevent obesity-related gestational complications. However, maternal malnutrition is not without potential risks during pregnancy. The objective was to evaluate the influence of time to conception after silastic ring Roux-en-Y gastric bypass (SRYGB) on maternal anemia. Patients who underwent SRYGB for morbid obesity and who subsequently became pregnant were followed up at the prenatal. Thirty pregnancies occurred between July 2001 and September 2009. The patients were analyzed according to time to conception after bariatric surgery: 17 patients with time to conception < 4 years (48 months) and 13 patients with a parts per thousand yen4 years. First trimester hemoglobin levels were significantly lower in patients with time to conception a parts per thousand yen4 years (48 months) (median 9.6 g/dL, range 5.8-13.2 g/dL) than in patients with time to conception < 4 years (median 11.1 g/dL, range 9.8-13.6 g/dL; p = 0.047). The need for intravenous iron therapy or packed red cell transfusion was significantly more frequent among women who became pregnant a parts per thousand yen4 years after SRYGB compared to < 4 years (30.8% vs. 0%, p = 0.026). Pregnancy after 4 years of SRYGB is associated with maternal anemia and the need for more strict iron supplementation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present a 20-year follow-up on a patient with a ring chromosome 14. The ring chromosome was studied by fluorescence in-situ hybridization (FISH), multiplex-ligation probe amplification (MLPA), and genome wide SNP array, and no deletions of chromosome 14 were detected, although the telomeric repeat sequence was absent from the ring chromosome. The patient had skeletal abnormalities, and susceptibility to infections, as well as seizures and retinal pigmentation, which are commonly found in individuals with a ring 14. Our patient corroborates the idea that even when no genes are lost during ring formation, a complete ring chromosome can produce phenotypic alterations, which presumably result from ring instability or gene silencing due to the new chromosomal architecture. (C) 2010 Wiley-Liss, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Essential blepharospasm is an idiopathic disorder that consists of spontaneous, spasmodic, and involuntary eyelid closure in the absence of ocular disease. Some patients develop an inability to open their eyelids in the absence of orbicularis spasms. These patients have essential blepharospasm combined with apraxia of eyelid opening. Botulinum toxin injections are the treatment of choice for blepharospasm but results may be insufficient, especially in cases associated with apraxia. Apraxia can be treated surgically by levator aponeurosis advancement, frontalis suspension, and upper myectomy. The authors report the first browlift using polypropylene suture to manage eyelid apraxia associated with blepharospasm as an alternative and minimally invasive procedure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recent in vitro data have suggested that the flavonoid quercetin (1) does not affect the functioning of neutrophils. Therefore, we evaluated in vivo and in vitro whether or not 1 affects neutrophil function, focusing on recruitment. The in vivo treatment with 1 inhibited in a dose-dependent manner the recruitment of neutrophils to the peritoneal cavity of mice induced by known chemotatic factors such as CXCL1, CXCL5, LTB(4), and fMLP. Further-more, 1 also inhibited in a concentration-dependent manner the chemoattraction of human neutrophils induced by CXCL8, LTB(4), and fMLP in a Boyden chamber. In vitro treatment with 1 did not affect human neutrophil surface expression of CXCR1, CXCR2, BLT1, or FLPR1, but rather reduced actin polymerization. These results suggest that 1 inhibits actin polymerization, hence, explaining the inhibition of neutrophil recruitment in vivo and in vitro and highlighting its possible usefulness to diminish excessive neutrophil migration during inflammation.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Progress in polymer science has led to continuous reduction of polymerization shrinkage, exemplified by a new generation of ""low-shrink composites"". The common inference that shrinkage stress effects will be reduced in teeth restored with such restoratives with lower shrinkage was tested in extracted human premolars. Mesio-occluso-distal slot-shaped cavities were cut and restored with a conventional (SupremePlus) or low-shrink (RefleXions, Premise, Kalore, and LS) composite (N = 5). We digitized the coronal surfaces before and 10 min after restoration to determine cuspal deflection from the buccal and lingual volume change/area. We also determined the main properties involved (total shrinkage, post-gel shrinkage, degree of conversion, and elastic modulus), as well as microleakage, to verify adequate bonding. It was shown that, due to shrinkage stresses, buccal and lingual surfaces pulled inward after restoration (9-14 microns). Only Kalore and LS resulted in significantly lower tooth deformation (ANOVA/Student-Newman-Keuls post hoc, p = 0.05). The other two low-shrink composites, despite having the lowest and highest total shrinkage values, did not cause significant differences in cuspal deflection. Deflection seemed most related to the combination of post-gel shrinkage and elastic modulus. Therefore, even for significantly lower total shrinkage values, shrinkage stress is not necessarily reduced.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective. To compare currently available low-shrinkage composites with others regarding polymerization stress, volumetric shrinkage (total and post-gel), shrinkage rate and elastic modulus. Methods. Seven BisGMA-based composites (Durafill/DU, Filtek Z250/FZ, Heliomolar/HM, Aelite LS Posterior/AP, Point 4/P4, Filtek Supreme/SU, ELS/EL), a silorane-based (Filtek LS, LS), a urethane-based (Venus Diamond, VD) and one based on a dimethacrylate-derivative of dimer acid (N`Durance, ND) were tested. Polymerization stress was determined in 1-mm high specimens inserted between two PMMA rods attached to a universal testing machine. Total volumetric shrinkage was measured using a mercury dilatometer. Maximum shrinkage rate was used as a parameter of the reaction speed. Post-gel shrinkage was measured using strain-gages. Elastic modulus was obtained by three-point bending. Data were submitted to one-way ANOVA/Tukey test (p = 0.05), except for elastic modulus (Kruskal-Wallis). Results. Composites ranked differently for total and post-gel shrinkage. Among the materials considered as ""low-shrinkage"" by the respective manufacturers, LS, EL and VD presented low post-gel shrinkage, while AP and ND presented relatively high values. Polymerization stress showed a strong correlation with post-gel shrinkage except for LS, which presented high stress. Elastic modulus and shrinkage rate showed weak relationships with polymerization stress. Significance. Not all low-shrinkage composites demonstrated reduced polymerization shrinkage. Also, in order to effectively reduce polymerization stress, a low post-gel shrinkage must be associated to a relatively low elastic modulus. (C) 2010 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective. Stress development at the tooth/restoration interface is one of the most important reasons for failure of adhesive restorations. The aim of this study was to evaluate the influence of BisGMA/TEGDMA (B/T) and UDMA/TEGDMA (U/T) ratios on polymerization stress (PS) and on the variables related to its development: degree of conversion (DC), polymerization maximum rate (Rp(max)), volumetric shrinkage (VS), elastic modulus (E), stress relaxation (SR) and viscosity of experimental composites. Method. Composites were formulated containing B/T or U/T in mol% ratios of 2: 8, 3: 7, 4: 6, 5: 5, 6: 4, 7: 3 and 8: 2, and 15 wt% of fumed silica. PS was determined with a universal testing machine. VS was measured with a linometer. E and SR were obtained in three-point bending. DC and Rp(max) were determined by real time NIR spectroscopy and viscosity was measured in viscometer. Data were submitted to one-way ANOVA, Tukey test (alpha = 0.05%) and regression analyses. Results. PS, VS, E and DC decreased and viscosity and Rp(max) increased with base monomer content in both series. PS showed strong correlation with VS, DC and viscosity. PS, VS and DC were higher and viscosity was lower for UDMA-based materials. Significance. Reduced viscosity, kinetics parameters and molecular characteristics led UDMA-based composites to elevated conversion and relatively lower PS at lower TEGDMA contents, compared to B/T composites. (C) 2010 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Our objective was to compare the polymerization stress (sigma(pol)) of a series of composites obtained using poly(methyl methacrylate) (PMMA) or glass as bonding substrates, and to compare the results with those from in vitro microleakage of composite restorations. The tested hypothesis was that stress values obtained in a less rigid testing system (i.e. using PMMA) would show a better relationship with microleakage data. Five dental composites were tested: Filtek Z250 (FZ), Z100 (Z1), Concept (CO), Durafill (DU) and Heliomolar (HM). sigma(pol) was determined in 1 mm high specimens inserted between two rods (empty set = 5 mm) of either PMMA or glass. The composite elastic modulus (E) was obtained by three-point bending. sigma(pol) and E data were submitted to a one-way analysis of variance/Tukey test (alpha = 0.05). For the microleakage test (MI), bovine incisors received cylindrical cavities (empty set = 5 mm, h = 2 mm), which were restored in bulk. After storage for 24 h in water, specimens were subjected to dye penetration using AgNO(3) as tracer. Specimens were sectioned twice, perpendicularly, and microleakage was measured (in millimeters) under 20x magnification. Data from MI were submitted to the Kruskal-Wallis test. Means (SD) of sigma(pol) (MPa) using glass/PMMA were FZ: 7.5(1.8)(A)/2.5(0.2)(bc); Z1: 7.3(0.5)(A)/2.8(0.3)(ab); CO: 6.8(1.1)(A)/3.2(0.5)(a); DU: 4.5(0.7)(B)/2.0(0.2)(bc); HM: 3.5(0.2)(B)/2.3(0.3)(c). sigma(pol) obtained using PMMA rods were 34-67% lower than with glass. Means (SD) for tooth average/tooth maximum microleakage were FZ: 0.92(0.19)(B)/1.53(0.30)(a); Z1: 1.19(0.21)(A)/1.75(0.20)(a); CO: 1.26(0.25)(A)/1.78(0.24)(a); DU: 0.83(0.30)(B)/1.68(0.46)(a): HM: 0.81(0.27)(B)/1.64(0.54)(a). The tested hypothesis was confirmed, as the composites showed the same ordering both in the polymerization stress test using PMMA rods and in the microleakage test. (C) 2009 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.