933 resultados para receive circuit


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper proposes a substrate integrated waveguide
(SIW) cavity-based method that is compliant with
ground-signal–ground (GSG) probing technology for dielectric
characterization of printed circuit board materials at millimeter
wavelengths. This paper presents the theory necessary to retrieve
dielectric parameters from the resonant characteristics of SIW
cavities with particular attention placed on the coupling scheme
and means for obtaining the unloaded resonant frequency. Different
sets of samples are designed and measured to address the
influence of the manufacturing process on the method. Material
parameters are extracted at - and -band from measured data
with the effect of surface roughness of the circuit metallization
taken into account.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This invention relates to electronic circuit packages designed to hold high frequency circuits operating particularly, but not exclusively, in the microwave, millimeter wave, and sub-millimeter wave bands. The invention provides a package incorporating a cavity in a material for containment of the circuits, wherein the package further incorporates at least one conductive surface mounted on an inner surface extending into the cavity, the conductivity thereof being adapted to be at least partially absorbent to electromagnetic radiation. The conductive surface according to the present invention will tend to attenuate electromagnetic radiation present within the cavity, and so help to prevent undesired coupling from one point to another within the cavity. The conductivity of the conductive material is preferably arranged to match the impedance of the radiation mode estimated or computed to be present within the cavity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a lookup circuit with advanced memory techniques and algorithms that examines network packet headers at high throughput rates. Hardware solutions and test scenarios are introduced to evaluate the proposed approach. The experimental results show that the proposed lookup circuit is able to achieve at least 39 million packet header lookups per second, which facilitates the application of next-generation stateful packet classifications at beyond 20Gbps internet traffic throughput rates.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A bit-level systolic array for computing matrix x vector products is described. The operation is carried out on bit parallel input data words and the basic circuit takes the form of a 1-bit slice. Several bit-slice components must be connected together to form the final result, and authors outline two different ways in which this can be done. The basic array also has considerable potential as a stand-alone device, and its use in computing the Walsh-Hadamard transform and discrete Fourier transform operations is briefly discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

DDR-SDRAM based data lookup techniques are evolving into a core technology for packet lookup applications for data network, benefitting from the features of high density, high bandwidth and low price of DDR memory products in the market. Our proposed DDR-SDRAM based lookup circuit is capable of achieving IP header lookup for network line-rates of up to 10Gbps, providing a solution on high-performance and economic packet header inspections. ©2008 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper investigates the implementation of a number of circuits used to perform a high speed closest value match lookup. The design is targeted particularly for use in a search trie, as used in various networking lookup applications, but can be applied to many other areas where such a match is required. A range of different designs have been considered and implemented on FPGA. A detailed description of the architectures investigated is followed by an analysis of the synthesis results. © 2006 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: To determine the factors associated with a home death among older adults who received palliative care nursing home services in the home. Methods: The participants in this retrospective cohort study were 151 family caregivers of patients who had died approximately 9 months prior to the study telephone interview. The interview focused on the last year of life and covered two main areas, patient characteristics and informal caregiver characteristics. Results: Odds ratios [OR] and 95% confidence intervals [95% CI] were used to determine which of the 15 potential informal caregiver and seven patient predictor variables were associated with dying at home. Multivariate analysis revealed that the odds of dying at home were greater when the patient lived with a caregiver [OR = 7.85; 95% CI = (2.35, 26.27)], the patient stated a preference to die at home [OR= 6.51; 95% CI = (2.66,15.95)], and the family physician made home visits [OR = 4.79; 95% CI = (1.97,11.64)]. However the odds were lower for patients who had caregivers with fair to poor health status [OR = 0.22; 95% CI = (0.07, 0.65)] and for patients who used hospital palliative care beds [OR = 0.31; 95% CI = (0.12, 0.80)]. Discussion: The findings suggest that individuals who indicated a preference to die at home and resided with a healthy informal caregiver had better odds of dying at home. Home visits by a family physician were also associated with dying at home.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We analyze the effect of different pulse shaping filters on the orthogonal frequency division multiplexing (OFDM) based wireless local area network (LAN) systems in this paper. In particular, the performances of the square root raised cosine (RRC) pulses with different rolloff factors are evaluated and compared. This work provides some guidances on how to choose RRC pulses in practical WLAN systems, e.g., the selection of rolloff factor, truncation length, oversampling rate, quantization levels, etc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the present study the tensile and super-elastic behaviours of laser-welded NiTi wires in Hanks’ solution at open-circuit potential (OCP) were investigated using tensile and cyclic slow-strain-rate tests (SSRT). In comparison with NiTi weldment tested in oil (non-corrosive environment), the weldment in Hanks’ solution suffered from obvious degradation in the tensile properties as evidenced by lower tensile strength, reduced maximum elongation, and a brittle fracture mode. Moreover, a larger residual strain was observed in the weldment after stress–strain cycles in Hanks’ solution. In addition to the microstructural defects resulting from the welding process, the inferior tensile and super-elastic behaviours of the NiTi weldment in Hanks’ solution could be attributed to the trapping of a large amount of hydrogen in the weld zone and heat-affected zone.