999 resultados para iron detection


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Capillary C4d deposition has been recognized as a marker of antibody-mediated rejection (AMR). Although the detection of capillary C4d by means of immunofluorescence (IF) in cryostat sections is well established, frozen tissue is not always available, thus limiting the diagnosis of AMR. The aim of the present study was to analyze different techniques for C4d staining and the prevalence of C4d in renal allograft biopsies. Detection of C4d was carried out using IF or immunohistochemistry (IHC) on frozen and paraffin sections of renal allograft biopsies available from the same patients. Biopsies obtained from 20 patients were classified into 3 groups: no rejection, acute rejection, and chronic allograft nephropathy (CAN). The capillary C4d deposition prevalence in frozen-IF, considered the gold standard technique for C4d detection, was 45% (9/20 cases). Compared with frozen-IF, the frozen-IHC technique presented an 85% concordance rate (17/20 cases; r =.70; P <.001; sensitivity = 77.8%; specificity = 90.9%). The paraffin-IF technique showed similar results, with an 80% concordance rate (16/20 cases; r =.64; P <.005; sensitivity = 55.6%; specificity = 100%), whereas C4d detection occurred in only 65% of paraffin-IHC cases (13/20; r =.30; not significant; sensitivity = 66.7%; specificity = 63.6%). No capillary C4d deposition was detected in cases without evidence of rejection. However, 4/7 cases (57%) of acute rejection were C4d positive. In the CAN group, 5111 cases (45%) were C4d positive. In conclusion, these results demonstrated that frozen-IHC and paraffin-IF can be considered alternative techniques to frozen-IF for C4d detection. The paraffin-IHC technique displayed the lowest concordance rate for C4d detection.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The detection of acidophilic microorganisms from mining environments by culture methods is time consuming and unreliable. Several PCR approaches were developed to amplify small-subunit rRNA sequences from the DNA of six bacterial phylotypes associated with acidic mining environments, permitting the detection of the target DNA at concentrations as low as 10 fg.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Transmission electron microscopy has been used to study the microstructure of an experimental white cast iran, in which a combination of modified alloy composition and unconventional heat treatment has resulted in a fracture toughness of 40 MPa m(-1/2). Microstructural features of the alloy that contribute to the toughness improvement and hence distinguish it from conventional white irons have been investigated. In the as-cast condition the dendrites are fully austenitic and the eutectic consists of M7C3 carbides and martensite. During heat treatment at 1130 degrees C the austenite is partially destabilized by precipitation of chromium-rich M7C3 carbides. This results in a dendritic microconstituent consisting of bulk retained austenite and secondary carbides which are sheathed with martensite. The martensite sheaths, which contain interlath films of retained austenite, are irregular in shape with some laths extending into the bulk retained austenite. Emphasis has been placed on the morphology, distribution, and stability of the retained austenite and its transformation products in the dendrites. The implications of these findings on the transformation toughening mechanism in this alloy are discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present work is a report of the characterization of superparamagnetic iron oxide nanoparticles coated with silicone used as a contrast agent in magnetic resonance imaging of the gastrointestinal tract. The hydrodynamic size of the contrast agent is 281.2 rim, where it was determined by transmission electron microscopy and a Fe(3)O(4) crystalline structure was identified by X-ray diffraction, also confirmed by Mossbauer Spectroscopy. The blocking temperature of 190 K was determined from magnetic measurements based on the Zero Field Cooled and Field Cooled methods. The hysteresis loops were measured at different temperatures below and above the blocking temperature. Ferromagnetic resonance analysis indicated the superparamagnetic nature of the nanoparticles and a strong temperature dependence of the peak-to-peak linewidth Delta H(pp), giromagnetic factor g, number of spins N(S) and relaxation time T(2) were observed. This behavior can be attributed to an increase in the superexchange interaction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The histopathological counterpart of white matter hyperintensities is a matter of debate. Methodological and ethical limitations have prevented this question to be elucidated. We want to introduce a protocol applying state-of-the-art methods in order to solve fundamental questions regarding the neuroimaging-neuropathological uncertainties comprising the most common white matter hyperintensities [WMHs] seen in aging. By this protocol, the correlation between signal features in in situ, post mortem MRI-derived methods, including DTI and MTR and quantitative and qualitative histopathology can be investigated. We are mainly interested in determining the precise neuroanatomical substrate of incipient WMHs. A major issue in this protocol is the exact co-registration of small lesion in a tridimensional coordinate system that compensates tissue deformations after histological processing. The protocol is based on four principles: post mortem MRI in situ performed in a short post mortem interval, minimal brain deformation during processing, thick serial histological sections and computer-assisted 3D reconstruction of the histological sections. This protocol will greatly facilitate a systematic study of the location, pathogenesis, clinical impact, prognosis and prevention of WMHs. (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Superparamagnetic iron oxide nanoparticles (SPIONs) are applied in stem cell labeling because of their high magnetic susceptibility as compared with ordinary paramagnetic species, their low toxicity, and their ease of magnetic manipulation. The present work is the study of CD133(+) stem cell labeling by SPIONs coupled to a specific antibody (AC133), resulting in the antigenic labeling of the CD133+ stem cell, and a method was developed for the quantification of the SPION content per cell, necessary for molecular imaging optimization. Flow cytometry analysis established the efficiency of the selection process and helped determine that the CD133 cells selected by chromatographic affinity express the transmembrane glycoprotein CD133. The presence of antibodies coupled to the SPION, expressed in the cell membrane, was observed by transmission electron microscopy. Quantification of the SPION concentration in the marked cells using the ferromagnetic resonance technique resulted in a value of 1.70 x 10 (13) mol iron (9.5 pg) or 7.0 x 10 (6) nanoparticles per cell ( the measurement was carried out in a volume of 2 mu L containing about 6.16 x 10 5 pg iron, equivalent to 4.5 x 10 (11) SPIONs). (c) 2008 Elsevier Inc. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We have developed a sensitive resonant four-wave mixing technique based on two-photon parametric four-wave mixing with the addition of a phase matched ''seeder'' field. Generation of the seeder field via the same four-wave mixing process in a high pressure cell enables automatic phase matching to be achieved in a low pressure sample cell. This arrangement facilitates sensitive detection of complex molecular spectra by simply tuning the pump laser. We demonstrate the technique with the detection of nitric oxide down to concentrations more than 4 orders of magnitude below the capability of parametric four-wave mixing alone, with an estimated detection threshold of 10(12) molecules/cm(3).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this work is to provide a quantitative method for analysis of the concentration of superparamagnetic iron oxide nanoparticles (SPION), determined by means of ferromagnetic resonance (FMR), with the nanoparticles coupled to a specific antibody (AC133), and thus to express the antigenic labeling evidence for the stem cells C D133(+). The FMR efficiency and sensitivity were proven adequate for detecting and quantifying the low amounts of iron content in the C D133(+) cells (similar to 6.16 x 10(5) pg in the volume of 2 mu l containing 4.5 x 1011 SPION). The quantitative method led to the result of 1.70 x 10(-13) mol of Fe (9.5 pg), or 7.0 x 10(6) nanoparticles per cell. For the quantification analysis via the FMR technique it was necessary to carry out a preliminary quantitative visualization of iron oxide-labeled cells in order to ensure that the nanoparticles coupled to the antibodies are indeed tied to the antigen at the stem cell surface and that the cellular morphology was conserved, as proof of the validity of this method. The quantitative analysis by means of FMR is necessary for determining the signal intensity for the study of molecular imaging by means of magnetic resonance imaging (MRI).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to establish parameters for the gaps-in-noise test in normal-hearing young adults. One hundred subjects (50 males and 50 females) received an audiological evaluation to rule out hearing loss and auditory processing disorder. The gaps-in-noise test was then conducted on all subjects. The mean gap detection threshold was 4.19 ms. A psychometric function by gap duration was constructed, revealing that the percentage of correct responses was less than or equal to 5% for a gap duration of 2 ms, 10-30% for a gap duration of 3 ms, 60-70% for a gap duration of 4 ms, and over 96% for gap durations of 5 ms or longer. The results suggest that the data obtained can be applied as reference values for future testing. In the subjects evaluated, the gaps-in-noise test proved to be consistent with low variability.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: In Brazil hospital malnutrition is highly prevalent. physician awareness of malnutrition is low, and nutrition therapy is underprescribed. One alternative to approach this problem is to educate health care providers in clinical nutrition. The present study aims to evaluate the effect of an intensive education course given to health care professionals and students on the diagnosis ability concerning to hospital malnutrition. Materials and methods: An intervention study based on a clinical nutrition educational program, offered to medical and nursing students and professionals, was held in a hospital of the Amazon region. Participants were evaluated through improvement of diagnostic ability, according to agreement of malnutrition diagnosis using Subjective Global Assessment before and after the workshop, as compared to independent evaluations (Kappa Index, k). To evaluate the impact of the educational intervention on the hospital malnutrition diagnosis, medical records were reviewed for documentation of parameters associated with nutritional status of in-patients. The SPSS statistical software package was used for data analysis. Results: A total of 165 participants concluded the program. The majority (76.4%) were medical and nursing students. Malnutrition diagnosis improved after the course (before k = 0.5; after k = 0.64; p < 0.05). A reduction of false negatives from 50% to 33.3% was observed. During the course, concern of nutritional diagnosis was increased W = 17.57; p < 0.001) and even after the course, improvement on the height measurement was detected chi(2) 12.87;p < 0.001). Conclusions: Clinical nutrition education improved the ability of diagnosing malnutrition; however the primary impact was on medical and nursing students. To sustain diagnostic capacity a clinical nutrition program should be part of health professional curricula and be coupled with continuing education for health care providers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A rapid DNA extraction was used for T. cruzi detection in triatomines dry fecal spots collected on filter paper and analyzed by PCR. Fifty T infestans were fed on experimentally infected Balb/C mice with high T. cruzi parasitemia and divided into five groups of len triatomines, and 100 triatomines were infected with lower parasitemia and divided into five groups of 20 triatomines, One dry fecal spot was analyzed per group on days 1, 2, 3, 4 and 5 post feeding. Amplification targeted T. cruzi TCZ sequence and resulted positive from day 4 after bugs feeding in the two models (high and lower parasitemia). The rapid DNA isolation and PCR proposed are suitable for detection of T. cruzi DNA in in filter paper and should be considered in field research.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To evaluate the impact of atypical retardation patterns (ARP) on detection of progressive retinal nerve fiber layer (RNFL) loss using scanning laser polarimetry with variable corneal compensation (VCC). DESIGN: Observational cohort study. METHODS: The study included 377 eyes of 221 patients with a median follow-up of 4.0 years. Images were obtained annually with the GDx VCC (Carl Zeiss Med, itec Inc, Dublin, California, USA), along with optic disc stereophotographs and standard automated perimetry (SAP) visual fields. Progression was determined by the Guided Progression Analysis software for SAP and by masked assessment of stereophotographs by expert graders. The typical scan score (TSS) was used to quantify the presence of ARPs on GDx VCC images. Random coefficients models were used to evaluate the relationship between ARP and RNFL thickness measurements over time. RESULTS: Thirty-eight eyes (10%) showed progression over time on visual fields, stereophotographs, or both. Changes in TSS scores from baseline were significantly associated with changes in RNFL thickness measurements in both progressing and nonprogressing eyes. Each I unit increase in TSS score was associated with a 0.19-mu m decrease in RNFL thickness measurement (P < .001) over time. CONCLUSIONS: ARPs had a significant effect on detection of progressive RNFL loss with the GDx VCC. Eyes with large amounts of atypical patterns, great fluctuations on these patterns over time, or both may show changes in measurements that can appear falsely as glaucomatous progression or can mask true changes in the RNFL. (Am J Ophthalmol 2009;148:155-163. (C) 2009 by Elsevier Inc. All rights reserved.)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To compare the ability of Fourier-domain (FD) optical coherence tomography (3D OCT-1000; Top, con, Tokyo, Japan) and time domain (TD) OCT (Stratus; Carl Zeiss Meditec Inc, Dublin, California, USA) to detect axonal loss in eyes with band atrophy (BA) of the optic nerve. DESIGN: Cross-sectional study. METHODS: Thirty-six eyes from 36 patients with BA and temporal visual field (VF) defect from chiasmal compression and 36 normal eyes were studied. Subjects were submitted to standard automated perimetry and macular and retinal nerve fiber layer (RNFL) measurements were taken using 3D OCT-1000 and Stratus OCT. Receiver operating characteristic (ROC) curves were calculated for each parameter. Spearman correlation coefficients were obtained to evaluate the relationship between RNFL and macular thickness parameters and severity of VF loss. Measurements from the two devices were compared. RESULTS: Regardless of OCT device, all RNFL and macular thickness parameters were significantly lower in eyes with BA compared with normal eyes, but no statistically significant difference was found with regard to the area under the ROC curve. Structure-function relationships were also similar for the two devices. In both groups, RNFL and macular thickness measurements were generally and in some cases significantly smaller with 3D OCT-1000 than with Stratus OCT. CONCLUSIONS: The introduction of FD technology did not lead to better discrimination ability for detecting BA of the optic nerve compared with TD technology when using the software currently provided by the manufacturer. 3D OCT-1000 FD OCT RNFL and macular measurements were generally smaller than TD Stratus OCT measurements. Investigators should be aware of this fact when comparing measurements obtained with these two devices. (Am J Oplathalmol 2009;147: 56-63. (c) 2009 by Elsevier Inc. All rights reserved.)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim To compare the ability of scanning laser polarimeter (SLP) with variable corneal compensation (GDx VCC) and optical coherence tomograph (Stratus OCT) to discriminate between eyes with band atrophy (BA) of the optic nerve and healthy eyes. Methods The study included 37 eyes with BA and temporal visual field (VF) defects from chiasmal compression, and 29 normal eyes. Subjects underwent standard automated perimetry (SAP) and retinal nerve fibre layer (RNFL) scans using GDx VCC and Stratus OCT. The severity of the VF defects was evaluated by the temporal mean defect (TMD), calculated as the average of 22 values of the temporal total deviation plot on SAP. Receiver operating characteristic (ROC) curves were calculated. Pearson`s correlation coefficients were used to evaluate the relationship between RNFL thickness parameters and the TMD. Results No significant difference was found between the ROC curves areas (AUCs) for the GDx VCC and Stratus OCT with regard to average RNFL thickness (0.98 and 0.99, respectively) and the superior (0.94; 0.95), inferior (0.96; 0.97), and nasal (0.92; 0.96) quadrants. However, the AUC in the temporal quadrant (0.77) was significantly smaller (P < 0.001) with GDx VCC than with Stratus OCT (0.98). Lower TMD values were associated with smaller RNFL thickness in most parameters from both equipments. Conclusion Adding VCC resulted in improved performance in SLP when evaluating eyes with BA, and both technologies are sensitive in detecting average, superior, inferior, and nasal quadrant RNFL loss. However, GDx VCC still poorly discriminates RNFL loss in the temporal quadrant when compared with Stratus OCT.