Comparison of the GDx VCC scanning laser polarimeter and the stratus optical coherence tomograph in the detection of band atrophy of the optic nerve


Autoria(s): MONTEIRO, M. L. R.; MOURA, F. C.
Contribuinte(s)

UNIVERSIDADE DE SÃO PAULO

Data(s)

19/10/2012

19/10/2012

2008

Resumo

Aim To compare the ability of scanning laser polarimeter (SLP) with variable corneal compensation (GDx VCC) and optical coherence tomograph (Stratus OCT) to discriminate between eyes with band atrophy (BA) of the optic nerve and healthy eyes. Methods The study included 37 eyes with BA and temporal visual field (VF) defects from chiasmal compression, and 29 normal eyes. Subjects underwent standard automated perimetry (SAP) and retinal nerve fibre layer (RNFL) scans using GDx VCC and Stratus OCT. The severity of the VF defects was evaluated by the temporal mean defect (TMD), calculated as the average of 22 values of the temporal total deviation plot on SAP. Receiver operating characteristic (ROC) curves were calculated. Pearson`s correlation coefficients were used to evaluate the relationship between RNFL thickness parameters and the TMD. Results No significant difference was found between the ROC curves areas (AUCs) for the GDx VCC and Stratus OCT with regard to average RNFL thickness (0.98 and 0.99, respectively) and the superior (0.94; 0.95), inferior (0.96; 0.97), and nasal (0.92; 0.96) quadrants. However, the AUC in the temporal quadrant (0.77) was significantly smaller (P < 0.001) with GDx VCC than with Stratus OCT (0.98). Lower TMD values were associated with smaller RNFL thickness in most parameters from both equipments. Conclusion Adding VCC resulted in improved performance in SLP when evaluating eyes with BA, and both technologies are sensitive in detecting average, superior, inferior, and nasal quadrant RNFL loss. However, GDx VCC still poorly discriminates RNFL loss in the temporal quadrant when compared with Stratus OCT.

Identificador

EYE, v.22, n.5, p.641-648, 2008

0950-222X

http://producao.usp.br/handle/BDPI/22296

10.1038/sj.eye.6702694

http://dx.doi.org/10.1038/sj.eye.6702694

Idioma(s)

eng

Publicador

NATURE PUBLISHING GROUP

Relação

Eye

Direitos

closedAccess

Copyright NATURE PUBLISHING GROUP

Palavras-Chave #optical coherence tomography #scanning laser polarimeter #retinal nerve fibre layer #band atrophy #FIBER LAYER THICKNESS #CORNEAL COMPENSATION #AXONAL LOSS #GLAUCOMA #EYES #BIREFRINGENCE #Ophthalmology
Tipo

article

original article

publishedVersion