915 resultados para Total hip arthroplasty revision surgery · tabular reconstruction · Bone loss · Ceramics
Resumo:
Nitric oxide (NO) derived from inducible nitric oxide synthase (iNOS) plays an important role in host defense, as well as in inflammation-induced tissue lesions. Here we evaluated the role of NO in bone loss in bacterial infection-induced apical periodontitis by using iNOS-deficient mice (iNOS(-/-)). The iNOS(-/-) mice developed greater inflammatory cell recruitment and osteolytic lesions than WT mice. Moreover, tartrate-resistant acid-phosphatase-positive (TRAP(+)) osteoclasts were significantly more numerous in iNOS-/- mice. Furthermore, the increased bone resorption in iNOS(-/-) mice also correlated with the increased expression of receptor activator NF-kappaB (RANK), stromal-cell-derived factor-1 alpha (SDF-1 alpha/CXCL12), and reduced expression of osteoprotegerin (OPG). These results show that NO deficiency was associated with an imbalance of bone-resorption-modulating factors, leading to severe infection-stimulated bone loss.
Resumo:
Purpose: The implant-abutment connection (microgap) influences the pen-implant bone morphology. However, it is unclear if different microgap configurations additionally modify bone reactions. This preliminary study aimed to radiographically monitor pen-implant bone levels in two different microgap configurations during 3 months of nonsubmerged healing. Materials and Methods: Six dogs received two implants with internal Morse taper connection (INT group) on one side of the mandible and two implants with external-hex connection (EXT group) on the other side. One implant on each side was positioned at bone level (equicrestal); the second implant was inserted 1.5 mm below the bone crest (subcrestal). Healing abutments were attached directly after implant insertion, and the implants were maintained for 3 months without prosthetic loading. At implant placement and 1, 2, and 3 months, standardized radiographs were taken to monitor pen-implant bone levels. Results: All implants osseointegrated. A total bone loss of 0.48 +/- 0.66 mm was measured in the equicrestal INT group, 0.69 +/- 0.43 mm in the equicrestal EXT group, 0.79 +/- 0.93 mm in the subcrestal INT group, and 1.56 +/- 0.53 mm in the subcrestal EXT group (P>.05, paired t tests). Within the four groups, bone loss over time became significantly greater in the EXT groups than in the INT groups. The greatest bone loss was noted in the subcrestal EXT group. Conclusion: Within the limits of this animal study, it seems that even without prosthetic loading, different microgap configurations exhibit different patterns of bone loss during nonsubmerged healing. Subcrestal positioning of an external butt joint microgap may lead to faster radiographic bone loss. Int J Prosthodont 2011;24:445-452.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Background: Vascular endothelial growth factor (VEGF) is a macromolecule of importance in inflammation that has been implicated in periodontitis. The aims of this study were to investigate VEGF expression during the progression of periodontal disease and to evaluate the effect of a preferential cyclooxygenase (COX)-2 inhibitor meloxicam on VEGF expression and alveolar bone loss in experimentally induced periodontitis.Methods: A total of 120 Wistar rats were randomly separated into groups 1 (control) and 2 (meloxicam, 3 mg/kg/day, intraperitoneally, for 3, 7, 14, or 30 days). Silk ligatures were placed at the gingival margin level of the lower right first molar of all rats. VEGF expression was assessed by reverse transcription-polymerase chain reaction (RT-PCR), Western blot (WB), and immunohistochemical (IHC) analyses. The hemiarcades were processed for histopathologic analysis. RT-PCR and WB results were submitted to analysis of variance, the Tukey test, and Pearson correlation analysis (P<0.05).Results: A reduction in alveolar bone resorption was observed in the meloxicam-treated group compared to the control group at all periods studied. There was a positive correlation between COX-2 mRNA and VEGF mRNA in the gingival tissues and periodontal disease (R = 0.80; P = 0.026). Meloxicam significantly reduced the increased mRNA VEGF expression in diseased tissues after 14 days of treatment (P = 0.023). Some alterations in VEGF receptor I mRNA expression were observed, but these were not statistically significant. VEGF protein expression in WB experiments was significantly higher in diseased sites compared to healthy sites (P<0.05). After 14 days of treatment with meloxicam, an important decrease in VEGF protein expression was detected in diseased tissues (P = 0.08). Qualitative IHC analysis revealed that VEGF protein expression was higher in diseased tissues and decreased in tissues from rats treated with meloxicam.Conclusions: The present data suggest an important role for VEGF in the progression of periodontal disease. Systemic therapy with meloxicam can modify the progression of experimentally induced periodontitis in rats by reducing VEGF expression and alveolar bone loss.
Resumo:
This study aimed at morphometrically evaluating the influence of variable caloric values of ethanol consumption on alveolar bone loss in periodontitis in male rats. Thirty-six male rats were randomized into four groups of nine rats each, as follows: Test group A (low) - rats were fed an ethanol-containing liquid diet (ethanol representing 22% of total caloric value); Control group A - rats were fed a pair-fed control diet (ethanol replaced by isocaloric amounts of carbohydrate); Test group B (high) - rats were fed an ethanol-containing liquid diet (ethanol representing 36% of total caloric value); Control group B - rats were fed a pair-fed control diet for Test B. Following anesthesia, cotton ligatures were placed around the cervix of the right upper second molar. At eight weeks, the maxillary bones were removed and alveolar bone loss was analyzed by measuring the distance between the cementoenamel junction and the alveolar bone crest at buccal and palatal sites of the upper second molar. The unligated groups showed no significant differences between the bone loss values observed for the low and high caloric values of ethanol (p > 0.05). In the ligated groups, the rats receiving low caloric values of ethanol showed significantly greater bone loss compared to the isocaloric rats (p < 0.05); however, the rats receiving high caloric values of ethanol showed no significant differences compared to the controls. Analysis of the results demonstrated that, in male rats, ethanol itself affected ligature-induced bone loss when representing a low value in the total caloric value.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Lo scopo di questo studio è stato quello di determinare se a lungo termine le concentrazioni sieriche di ioni nei pazienti con protesi di rivestimento d’anca metallo-metallo (MOM-HR, metal-on-metal hip resurfacing) fossero differenti da quelle valutate nei pazienti con protesi totale d’anca metallo-metallo e testa del diametro di 28 mm (MOM-THA, metal-on-metal total hip arthroplasty); inoltre è stato valutato se le concentrazioni ioniche fossero al di sopra dei valori di riferimento e se fosse possibile stabilire l’esistenza di una relazione tra sesso e concentrazioni di ioni con riferimento al tipo di impianto. Il gruppo MOM-HR era costituito da 25 pazienti mentre il gruppo MOM-THA era di 16 pazienti. Per poter ricavare i valori di riferimento sono stati reclutati 48 donatori sani. La misurazione delle concentrazioni degli ioni cobalto (Co), cromo (Cr), nickel (Ni) e molibdeno (Mo) è stata effettuata utilizzando la spettrofotometria ad assorbimento atomico su fornace di grafite. A parte il Ni, le concentrazioni di ioni nei pazienti con MOM-HR erano più elevate rispetto ai controlli. Il rilascio di ioni Cr e Co nei pazienti con MOM-HR è risultato superiore rispetto ai soggetti con MOM-THA. Da un’analisi basata sul sesso, è emerso che nelle femmine con MOM-HR i livelli di ioni Cr e Co sono risultati significativamente aumentati rispetto alle femmine con MOM-THA. Indipendentemente dal tipo di impianto, gli accoppiamenti metallo-metallo (MOM) producono concentrazioni di ioni metallici significativamente più alte a follow-up a lungo termine rispetto a quelle osservate nei soggetti sani. Un fattore che deve essere attentamente considerato nella scelta dell’impianto, e in particolar modo nei soggetti giovani, è il cospicuo rilascio di ioni Cr e Co nella popolazione femminile con MOM-HR.
Resumo:
To date, obesity affects a substantial population in industrialised countries. Due to the increased awareness of obesity-related morbidity, efficient dietary regimens and the recent successes with bariatric surgery, there is now a high demand for body contouring surgery to correct skin abundancies after massive weight loss. The known risks for this type of surgery are mainly wound-healing complications, and, more rarely, thromboembolic or respiratory complications. We present two female patients (23 and 39 years of age) who, in spite of standard positioning and precautions, developed sciatic neuropathy after combined body contouring procedures, including abdominoplasty and inner thigh lift. Complete functional loss of the sciatic nerve was found by clinical and electroneurographic examination on the left side in patient one and bilaterally in patient two. Full nerve conductance recovery was obtained after 6 months in both patients. Although the occurrence of spontaneous neuropathies after heavy weight loss is well documented, this is the first report describing the appearance of such a phenomenon following body contouring surgery. One theoretical explanation may be the compression of the nerve during the semirecumbent positioning combined with hip flexion and abduction, which was required for abdominal closure and simultaneous access to the inner thighs. We advise to avoid this positioning and to include the risk of sciatic neuropathy in the routine preoperative information of patients scheduled for body contouring surgery after heavy weight loss.
Resumo:
Although surgical navigation reduces the rate of malpositioned acetabular cups in total hip arthroplasty (THA), its use has not been widely adopted. As a result of our perceived need for simple and efficient methods of navigation, we developed a mechanical navigation device for acetabular cup orientation.
Resumo:
OBJECTIVE: To compare six different parameters described in literature for estimation of pelvic tilt on an anteroposterior pelvic radiograph and to create a simple nomogram for tilt correction of prosthetic cup version in total hip arthroplasty. DESIGN: Simultaneous anteroposterior and lateral pelvic radiographs are taken routinely in our institution and were analyzed prospectively. The different parameters (including three distances and three ratios) were measured and compared to the actual pelvic tilt on the lateral radiograph using simple linear regression analysis. PATIENTS: One hundred and four consecutive patients (41 men, 63 women with a mean age of 31.7 years, SD 9.2 years, range 15.7-59.1 years) were studied. RESULTS: The strongest correlation between pelvic tilt and one of the six parameters for both men and women was the distance between the upper border of the symphysis and the sacrococcygeal joint. The correlation coefficient was 0.68 for men (P<0.001) and 0.61 for women (P<0.001). Based on this linear correlation, a nomogram was created that enables fast, tilt-corrected cup version measurements in clinical routine use. CONCLUSION: This simple method for correcting variations in pelvic tilt on plain radiographs can potentially improve the radiologist's ability to diagnose and interpret malformations of the acetabulum (particularly acetabular retroversion and excessive acetabular overcoverage) and post-operative orientation of the prosthetic acetabulum.
Resumo:
This paper addresses the problem of estimating postoperative cup alignment from single standard X-ray radiograph with gonadal shielding. The widely used procedure of evaluation of cup orientation following total hip arthroplasty using single standard anteroposterior radiograph is known inaccurate, largely due to the wide variability in individual pelvic position relative to X-ray plate. 2D-3D image registration methods have been introduced to estimate the rigid transformation between a preoperative CT volume and postoperative radiograph(s) for an accurate estimation of the postoperative cup alignment relative to an anatomical reference extracted from the CT data. However, these methods require either multiple radiographs or a radiograph-specific calibration, both of which are not avaiable for most retrospective studies. Furthermore, these methods were only evaluated on X-ray radiograph(s) without gonadal shielding. In this paper, we propose to use a hybrid 2D-3D registration scheme combining an iterative landmark-to-ray registration with a 2D-3D intensity-based registration to estimate the rigid transfromation for a precise estimation of cup alignment. Quantitative and qualitative results evaluated on clinical and cadaveric datasets are given which indicate the validity of our approach.
Resumo:
Spinal cord injury (SCI) leads to severe bone loss in the paralysed limbs and to a resulting increased fracture risk thereof. Since long bone fractures can lead to comorbidities and a reduction in quality of life, it is important to improve bone strength in people with chronic SCI. In this prospective longitudinal cohort study, we investigated whether functional electrical stimulation (FES) induced high-volume cycle training can partially reverse the loss of bone substance in the legs after chronic complete SCI. Eleven participants with motor-sensory complete SCI (mean age 41.9+/-7.5 years; 11.0+/-7.1 years post injury) were recruited. After an initial phase of 14+/-7 weeks of FES muscle conditioning, participants performed on average 3.7+/-0.6 FES-cycling sessions per week, of 58+/-5 min each, over 12 months at each individual's highest power output. Bone and muscle parameters were investigated in the legs by means of peripheral quantitative computed tomography before the muscle conditioning (t1), and after six (t2) and 12 months (t3) of high-volume FES-cycle training. After 12 months of FES-cycling, trabecular and total bone mineral density (BMD) as well as total cross-sectional area in the distal femoral epiphysis increased significantly by 14.4+/-21.1%, 7.0+/-10.8% and 1.2+/-1.5%, respectively. Bone parameters in the femoral shaft showed small but significant decreases, with a reduction of 0.4+/-0.4% in cortical BMD, 1.8+/-3.0% in bone mineral content, and 1.5+/-2.1% in cortical thickness. These decreases mainly occurred between t1 and t2. No significant changes were found in any of the measured bone parameters in the tibia. Muscle CSA at the thigh increased significantly by 35.5+/-18.3%, while fat CSA at the shank decreased by 16.7+/-12.3%. Our results indicate that high-volume FES-cycle training leads to site-specific skeletal changes in the paralysed limbs, with an increase in bone parameters at the actively loaded distal femur but not the passively loaded tibia. Thus, we conclude that high-volume FES-induced cycle training has clinical relevance as it can partially reverse bone loss and thus may reduce fracture risk at this fracture prone site.
Resumo:
Our goal was to validate accuracy, consistency, and reproducibility/reliability of a new method for determining cup orientation in total hip arthroplasty (THA). This method allows matching the 3D-model from CT images or slices with the projected pelvis on an anteroposterior pelvic radiograph using a fully automated registration procedure. Cup orientation (inclination and anteversion) is calculated relative to the anterior pelvic plane, corrected for individual malposition of the pelvis during radiograph acquisition. Measurements on blinded and randomized radiographs of 80 cadaver and 327 patient hips were investigated. The method showed a mean accuracy of 0.7 +/- 1.7 degrees (-3.7 degrees to 4.0 degrees) for inclination and 1.2 +/- 2.4 degrees (-5.3 degrees to 5.6 degrees) for anteversion in the cadaver trials and 1.7 +/- 1.7 degrees (-4.6 degrees to 5.5 degrees) for inclination and 0.9 +/- 2.8 degrees (-5.2 degrees to 5.7 degrees) for anteversion in the clinical data when compared to CT-based measurements. No systematic errors in accuracy were detected with the Bland-Altman analysis. The software consistency and the reproducibility/reliability were very good. This software is an accurate, consistent, reliable, and reproducible method to measure cup orientation in THA using a sophisticated 2D/3D-matching technique. Its robust and accurate matching algorithm can be expanded to statistical models.
Resumo:
INTRODUCTION To present the accuracy of reduction, complications and results two years after open reduction and internal fixation of displaced acetabular fractures involving the anterior column (AC) through the Pararectus approach. Frequencies for conversion to total hip replacement in the early follow up, the clinical outcome in preserved hips, and the need for an extension of the approach (1st window of the ilioinguinal approach) are compared to the literature about the modified Stoppa approach. METHODS Forty-eight patients (mean age 62 years, range: 16–98; 41 male) with displaced acetabular fractures involving the AC (AC: n = 9; transverse fracture: n = 2; AC and hemitransverse: n = 24; both column: n = 13) were treated between 12/2009 and 12/2011 using the Pararectus approach. Surgical data and accuracy of reduction (using computed tomography) were assessed. Patients were routinely followed up at eight weeks, 6, 12 and 24 months postoperatively. Failure was defined as the need for total hip arthroplasty. Twenty-four months postoperatively the outcome was rated according to Matta. RESULTS In four patients there were four intraoperative complications (minor vascular damage in two, small perforations of the peritoneum in two) which were managed intraoperatively. Fracture reduction showed statistically significant decreases (mean ± SD, pre- vs. postoperative, in mm) in “step-offs”: 2.6 ± 1.9 vs. 0.1 ± 0.3, p < 0.001 and “gaps”: 11.2 ± 6.8 vs. 0.7 ± 0.9, p < 0.001. Accuracy of reduction was “anatomical” in 45, “imperfect” in three. Five (13%) from 38 available patients required a total hip arthroplasty. Of 33 patients with a preserved hip the clinical outcome was graded as “excellent” in 13 or “good” in 20; radiographically, 27 were graded as “excellent”, four as “good” and two as “fair”. An extension of the approach was infrequently used (1st window ilioinguinal approach in 2%, mini-incision at the iliac crest in 21%). CONCLUSION In the treatment of acetabular fractures involving the anterior column the Pararectus approach allowed for anatomic restoration with minimal access morbidity. Results obtained by means of the Pararectus approach after two years at least parallel those reported after utilisation of the modified Stoppa approach. In contrast to the modified Stoppa approach, a relevant extension of the Pararectus approach was almost not necessary.
Resumo:
OBJECTIVE The aim of this cross-sectional study was to estimate bone loss of implants with platform-switching design and analyze possible risk indicators after 5 years of loading in a multi-centered private practice network. METHOD AND MATERIALS Peri-implant bone loss was measured radiographically as the distance from the implant shoulder to the mesial and distal alveolar crest, respectively. Risk factor analysis for marginal bone loss included type of implant prosthetic treatment concept and dental status of the opposite arch. RESULTS A total of 316 implants in 98 study patients after 5 years of loading were examined. The overall mean value for radiographic bone loss was 1.02 mm (SD ± 1.25 mm, 95% CI 0.90- 1.14). Correlation analyses indicated a strong association of peri-implant bone loss > 2 mm for removable implant-retained prostheses with an odds ratio of 53.8. CONCLUSION The 5-year-results of the study show clinically acceptable values of mean bone loss after 5 years of loading. Implant-supported removable prostheses seem to be a strong co-factor for extensive bone level changes compared to fixed reconstructions. However, these results have to be considered for evaluation of the included special cohort under private dental office conditions.