Precise estimation of postoperative cup alignment from single standard X-ray radiograph with gonadal shielding


Autoria(s): Zheng, Guoyan; Steppacher, Simon; Zhang, Xuan; Tannast, Moritz
Data(s)

2007

Resumo

This paper addresses the problem of estimating postoperative cup alignment from single standard X-ray radiograph with gonadal shielding. The widely used procedure of evaluation of cup orientation following total hip arthroplasty using single standard anteroposterior radiograph is known inaccurate, largely due to the wide variability in individual pelvic position relative to X-ray plate. 2D-3D image registration methods have been introduced to estimate the rigid transformation between a preoperative CT volume and postoperative radiograph(s) for an accurate estimation of the postoperative cup alignment relative to an anatomical reference extracted from the CT data. However, these methods require either multiple radiographs or a radiograph-specific calibration, both of which are not avaiable for most retrospective studies. Furthermore, these methods were only evaluated on X-ray radiograph(s) without gonadal shielding. In this paper, we propose to use a hybrid 2D-3D registration scheme combining an iterative landmark-to-ray registration with a 2D-3D intensity-based registration to estimate the rigid transfromation for a precise estimation of cup alignment. Quantitative and qualitative results evaluated on clinical and cadaveric datasets are given which indicate the validity of our approach.

Formato

application/pdf

Identificador

http://boris.unibe.ch/24443/1/24443.pdf

Zheng, Guoyan; Steppacher, Simon; Zhang, Xuan; Tannast, Moritz (2007). Precise estimation of postoperative cup alignment from single standard X-ray radiograph with gonadal shielding. In: Medical Image Computing and Computer-Assisted Intervention – MICCAI 2007. Lecture notes in computer science: Vol. 10 (pp. 951-959). Berlin: Springer 10.1007/978-3-540-75759-7_115 <http://dx.doi.org/10.1007/978-3-540-75759-7_115>

doi:10.7892/boris.24443

info:doi:10.1007/978-3-540-75759-7_115

info:pmid:18044660

urn:issn:0302-9743

urn:isbn:978-3-540-75759-7

Idioma(s)

eng

Publicador

Springer

Relação

http://boris.unibe.ch/24443/

Direitos

info:eu-repo/semantics/restrictedAccess

Fonte

Zheng, Guoyan; Steppacher, Simon; Zhang, Xuan; Tannast, Moritz (2007). Precise estimation of postoperative cup alignment from single standard X-ray radiograph with gonadal shielding. In: Medical Image Computing and Computer-Assisted Intervention – MICCAI 2007. Lecture notes in computer science: Vol. 10 (pp. 951-959). Berlin: Springer 10.1007/978-3-540-75759-7_115 <http://dx.doi.org/10.1007/978-3-540-75759-7_115>

Tipo

info:eu-repo/semantics/conferenceObject

info:eu-repo/semantics/publishedVersion

PeerReviewed