944 resultados para Waste water treatment plants
Resumo:
Dissertação de mestrado integrado em Engenharia Civil
Resumo:
Dissertação de mestrado integrado em Engenharia Civil
Resumo:
This study characterized the fecal indicator bacteria (FIB), including Escherichia coli (E. coli) and Enteroccocus (ENT), disseminated over time in the Bay of Vidy, which is the most contaminated area of Lake Geneva. Sediments were collected from a site located at similar to 500 m from the present waste water treatment plant (WWTP) outlet pipe, in front of the former WWTP outlet pipe, which was located at only 300 m from the coastal recreational area (before 2001). E. coil and ENT were enumerated in sediment suspension using the membrane filter method. The FIB characterization was performed for human Enterococcus faecalis (E. faecalis) and Enterococcus faecium (E. faecium) and human specific bacteroides by PCR using specific primers and a matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS). Bacterial cultures revealed that maximum values of 35.2 x 10(8) and 6.6 x 10(6) CFU g(-1) dry sediment for E. coil and ENT, respectively, were found in the sediments deposited following eutrophication of Lake Geneva in the 1970s. whereas the WWTP started operating in 1964. The same tendency was observed for the presence of human fecal pollution: the percentage of PCR amplification with primers ESP-1/ESP-2 for E. faecalis and E. faecium indicated that more than 90% of these bacteria were from human origin. Interestingly, the PCR assays for specific-human bacteroides HF183/HF134 were positive for DNA extracted from all isolated strains of sediment surrounding WWPT outlet pipe discharge. The MALDI-TOF MS confirmed the presence of general E. coli and predominance E. faecium in isolated strains. Our results demonstrated that human fecal bacteria highly increased in the sediments contaminated with WWTP effluent following the eutrophication of Lake Geneva. Additionally, other FIB cultivable strains from animals or adapted environmental strains were detected in the sediment of the bay. The approaches used in this research are valuable to assess the temporal distribution and the source of the human fecal pollution in aquatic environments. (C) 2011 Elsevier Inc. All rights reserved.
Resumo:
This report is presented in two parts . P a r t I takes a new look at the design of rest area stabilization ponds after nearly 10 years' experience with some of the existing ponds and in the light of new design standards issued by Iowa DEQ. The Iowa DOT is embarking on improvements t o the ponds a t some of the r e s t areas. These improvements may include installation of drainage tile around the ponds to lower the water table below the pond bottom, sealing of the ponds with bentonite clay to reduce the infiltration to limits recently established by Iowa DEQ, and the enlargement of the ponds installation of aeration equipment t o increase the pond capacity. As the Iowa DOT embarks on this improvement program, it behooves them t o make only the improvements that are absolutely necessary to achieve waste water treatment goals. These ponds are subject to an extremely seasonal load and thus the ordinary standards used for pond design are not appropriate. Thus, Part I of the report presents a rationale for design and operation of the ponds which is deemed appropriate for t h e i r unique seasonally loaded character. Part I1 of the report looks a t the feasibility of using wind power for the aeration of the ponds, if and when aeration is deemed necessary.
Resumo:
Astonishing as it may seem, one organism's waste is often ideal food for another. Many waste products generated by human activities are routinely degraded by microorganisms under controlled conditions during waste-water treatment. Toxic pollutants resulting from inadvertent releases, such as oil spills, are also consumed by bacteria, the simplest organisms on Earth. Biodegradation of toxic or particularly persistent compounds, however, remains problematic. What has escaped the attention of many is that bacteria exposed to pollutants can adapt to them by mutating or acquiring degradative genes. These bacteria can proliferate in the environment as a result of the selection pressures created by pollutants. The positive outcome of selection pressure is that harmful compounds may eventually be broken down completely through biodegradation. The downside is that biodegradation may require extremely long periods of time. Although the adaptation process has been shown to be reproducible, it remains very difficult to predict.
Resumo:
Ympäristönsuojelulain (86/2000) 19 §:n nojalla kunnilla voi olla ympäristönsuojelumääräykset. Määräysten antaminen on kunnille vapaaehtoista. Määräysten tulee olla ympäristönsuojelulain täytäntöönpanon kannalta tarpeellisia, kunnan paikallisista olosuhteista johtuvia kuntaa tai sen osaa koskevia yleisiä määräyksiä. Määräykset antaa kunnanvaltuusto. Ympäristönsuojelumääräyksillä on muuta lainsäädäntöä täydentävä, ei korvaava asema. Tämän työn tavoitteena oli laatia Kotkan kaupungille ehdotus kunnan ympäristönsuojelumääräyksiksi. Työn teoriaosassaon selvitetty kunnan ympäristönsuojelumääräysten oikeudelliset lähtökohdat ja suhde muuhun lainsäädäntöön. Tulososassa on selvitetty mitä toimintoja Kotkassa tulisi säännellä kunnan ympäristönsuojelumääräyksin. Työn toimeksiantajan kannalta oleellisimmat tulokset on esitetty työn liiteosassa. Ehdotuksen määräykset koskevat jätevesien käsittelyä, lumenkaatopaikkojen aiheuttamia ympäristöhaittoja, pölyn torjuntaa, tilapäisen melun torjuntaa, öljysäiliöiden tarkastamista ja käytöstä poistamista sekä hevosten pidon ympäristövaikutuksia. Ympäristönsuojelumääräysten voimaantulon myötä osa ympäristönsuojeluviranomaisen antamista suosituksista saa sitovan vaikutuksen. Ympäristönsuojelumääräykset osaltaan selventävät ympäristönsuojeluviranomaisen mahdollisuuksia puuttua eri toimintojen ympäristövaikutuksiin ennakolta.
Resumo:
Työssä tutkittiin, mikä on kustannustehokkain tapa lisätä ilmastuskapasiteettia ja selvitettiin, saostaako vesilaitokselta flotaatioaltaasta poistettava ferrisulfaattisakka jäteveden fosforia esiselkeyttimessä. Työssä määritettiin teoreettinen hapentarve ilmastusaltaassa maksimikuormituksen aikana ja hapensiirtonopeus jäteveteen olemassa olevalla laitteistolla. Hapensiirtonopeuden funktion korjauskertoimet ja sekä kokonaishapensiirtokerroin määritettiin laboratorio-olosuhteissa. Lisäksi laskettiin kuinka paljon nykyisten ilmastimien kautta saadaan happea jäteveteen liukenemaan ja verrattiin tätä lukua teoreettiseen hapentarpeeseen. Jälkimmäistä menettelytapaa käyttäen arvioitiin lisähapen tarve. Tulokseksi saatiin, että maksimi BOD-kuormituksen aikana happea tarvitsee saada jäteveteen liuotettua 5200 m³/d lisää. Ilmastuskapasiteetin lisäyksen kustannuslaskelmassa verrattiin neljää vaihtoehtoa: puhdasta happea liuotettuna happimattojen kautta tai OKI-ilmastimen kautta, onsite-happilaitoksen puhdasta happea liuotettuna OKI-ilmastimen kautta tai ilman happea liuotettuna jäteveteen EDI-ilmastimien kautta. Laskelmat osoittivat uusien EDI-ilmastimien hankinnan olevan edullisin vaihtoehto pitkällä aikavälillä. Vaikka EDI-ilmastimien investointikustannukset ovat korkeat, tulevat ne käyttökustannuksiltaan kaikkein edullisimmaksi. Vesilaitokselta tulevan rautasuolasakan fosforia saostavaa vaikutusta tutkittiin laboratoriossa astiakokein. Näytteet otettiin vesilaitokselta jätevesilaitokselle menevästä rautasuolasakasta sekä esiselkeyttimen kirkasteesta. Näitä eri suhteissa keskenään sekoittamalla saatiin selville, että rautasuolasakka ja sakan mukana tuleva reagoimaton rautasuola saostavat liukoista ja kokonaisfosforia esiselkeytyksessä.
Resumo:
Schauman Wood Oy Pelloksen tehtaat on Euroopan suurin havuvanerin valmistaja. Tehtailla tukkien haudonnassa ja kuorien kuivaamisessa syntyvät jätevedet sekä sosiaalijätevedet puhdistetaan omassa biologisessa puhdistamossa. Puhdistamo rakennettiin alun perin aktiivilietelaitokseksi ja muutettiin kuormituksen kasvaessa vuonna 2002 kantoaineprosessiksi. Puhdistamolle laskettiin ensin optimaalinen kuormitus, jonka perusteella kuormitusta ryhdyttiin nostamaan. Tavoitteena oli saavuttaa virtaaman nostolla ja ajomallien muutoksilla tilavuuskuorma 1-3 kgBOD/m3•d. Kun tulovirtaamaa oli saatu nostettua riittävästi, tehtiin laskeutuskokeita laskeutuskemikaalin optimimäärän selvittämiseksi. Koeajojakson lopuksi pidettiin kolmen viikon tehotarkkailujakso, jolloin kokeiltiin puhdistamon ajoa erilaisilla kemikaalimäärillä. Näin saatiin selville tasemielessä tietyn puumäärän aiheuttama kuormitus puhdistamolle. Jätevedenpuhdistamon tulovirtaama saatiin nostettua tasolle 300- 350 m³/d, jolloin tilaavuuskuormaksi tuli 1,68 kgBOD/m3•d. Kolmen viikon tehotarkkailujakson aikana saatiin selvitettyä optimikemikaaliannostus sekä laskettua kolmesta eri vaihtoehdosta taloudellisesti kannattavin ajomalli. Puhdistusreduktioiden, puhdistamon toimivuuden ja taloudellisuuden kannalta paras vaihtoehto oli laskeutuskemikaalin ja polymeerin yhteiskäyttö.
Resumo:
Object of the Master’s thesis was to obtain clarification to problems related to sludge treatment at the waste water treatment plant at Stora Enso Varkaus Mill. From time to time these problems have caused emissions to exceed given limits. Case was studied by examining existing data, fiber length fractions and experimental methods. Changes at the Mill have reduced total solids emissions. At the same time the requirement for tertiary treatment has grown. Treatment of tertiary sludge is hard. In the future emission limits shall tighten and the urge for tertiary treatment will grow. The significance of thesis’s results may have a great impact to Stora Enso Varkaus Mill in the future. The results give valuable information to follow-up research and guidelines to sludge treatment. The results encourage observing researched matters at longer period of time. Future recommendations emphasize the meaning of maintenance and systematic, appropriate experiments.
Resumo:
COD discharges out of processes have increased in line with elevating brightness demands for mechanical pulp and papers. The share of lignin-like substances in COD discharges is on average 75%. In this thesis, a plant dynamic model was created and validated as a means to predict COD loading and discharges out of a mill. The assays were carried out in one paper mill integrate producing mechanical printing papers. The objective in the modeling of plant dynamics was to predict day averages of COD load and discharges out of mills. This means that online data, like 1) the level of large storage towers of pulp and white water 2) pulp dosages, 3) production rates and 4) internal white water flows and discharges were used to create transients into the balances of solids and white water, referred to as “plant dynamics”. A conversion coefficient was verified between TOC and COD. The conversion coefficient was used for predicting the flows from TOC to COD to the waste water treatment plant. The COD load was modeled with similar uncertainty as in reference TOC sampling. The water balance of waste water treatment was validated by the reference concentration of COD. The difference of COD predictions against references was within the same deviation of TOC-predictions. The modeled yield losses and retention values of TOC in pulping and bleaching processes and the modeled fixing of colloidal TOC to solids between the pulping plant and the aeration basin in the waste water treatment plant were similar to references presented in literature. The valid water balances of the waste water treatment plant and the reduction model of lignin-like substances produced a valid prediction of COD discharges out of the mill. A 30% increase in the release of lignin-like substances in the form of production problems was observed in pulping and bleaching processes. The same increase was observed in COD discharges out of waste water treatment. In the prediction of annual COD discharge, it was noticed that the reduction of lignin has a wide deviation from year to year and from one mill to another. This made it difficult to compare the parameters of COD discharges validated in plant dynamic simulation with another mill producing mechanical printing papers. However, a trend of moving from unbleached towards high-brightness TMP in COD discharges was valid.
Resumo:
Centrifugal compressors are widely used for example in refrigeration processes, the oil and gas industry, superchargers, and waste water treatment. In this work, five different vaneless diffusers and six different vaned diffusers are investigated numerically. The vaneless diffusers vary only by their diffuser width, so that four of the geometries have pinch implemented to them. Pinch means a decrease in the diffuser width. Four of the vaned diffusers have the same vane turning angle and a different number of vanes, and two have different vane turning angles. The flow solver used to solve the flow fields is Finflo, which is a Navier-Stokes solver. All the cases are modeled with the Chien's k – έ- turbulence model, and selected cases are modeled also with the k – ώ-SST turbulence model. All five vaneless diffusers and three vaned diffusers are investigated also experimentally. For each construction, the compressor operating map is measured according to relevant standards. In addition to this, the flow fields before and after the diffuser are measured with static and total pressure, flow angle and total temperature measurements. When comparing the computational results to the measured results, it is evident that the k – ώ-SST turbulence model predicts the flow fields better. The simulation results indicate that it is possible to improve the efficiency with the pinch, and according to the numerical results, the two best geometries are the ones with most pinch at the shroud. These geometries have approximately 4 percentage points higher efficiency than the unpinched vaneless diffusers. The hub pinch does not seem to have any major benefits. In general, the pinches make the flow fields before and after the diffuser more uniform. The pinch also seems to improve the impeller efficiency. This is down to two reasons. The major reason is that the pinch decreases the size of slow flow and possible backflow region located near the shroud after the impeller. Secondly, the pinches decrease the flow velocity in the tip clearance, leading to a smaller tip leakage flow and therefore slightly better impeller efficiency. Also some of the vaned diffusers improve the efficiency, the increment being 1...3 percentage points, when compared to the vaneless unpinched geometry. The measurement results confirm that the pinch is beneficial to the performance of the compressor. The flow fields are more uniform with the pinched cases, and the slow flow regions are smaller. The peak efficiency is approximately 2 percentage points and the design point efficiency approximately 4 percentage points higher with the pinched geometries than with the un- pinched geometry. According to the measurements, the two best geometries are the ones with the most pinch at the shroud, the case with the pinch only at the shroud being slightly better of the two. The vaned diffusers also have better efficiency than the vaneless unpinched geometries. However, the pinched cases have even better efficiencies. The vaned diffusers narrow the operating range considerably, whilst the pinch has no significant effect on the operating range.
Resumo:
The growing concern of environmental surveillance of the quality of hydric resources guides the development of research on management of residues generated in water treatment plants (WTP). Approximately 8.000 WTPs in Brazil operate without a treatment program of the residues, disposing these effluents in the environment. This work evaluated WTP discharges into watercourses by collecting superficial waters, sediments and benthic samples at the town of Registro, São Paulo State, Brazil. Even though superficial waters and benthic samples showed no further contamination, sediment analysis pointed out that aluminum deposits detected near sludge discharges may represent a potential risk to the environment.
Resumo:
The work reported here involved the characterization of sludges produced at water treatment plants in Jaboticabal-SP using FeCl3 as flocculant, and in Taquaritinga-SP and Manaus-AM using Al2(SO4)3 as flocculant. An evaluation was also made of the interaction of organic matter extracted from the sludges with different metal species. The results indicated that all the sludges produced at water treatment plants have an important agricultural potential and that their use depends on the characteristics of the raw water and the type of flocculant employed in conventional treatment. The humic substances extracted from the sludges showed different affinities for metal species, favoring eventual exchanges between potentially toxic metals and macro- and micronutrients. An alternative for the use of sludge in agriculture is to pretreat it to remove potentially toxic metals and enrich it with micro- and macronutrients that can be released to the plant.
Resumo:
Lappeenrannassa kerätään ja hyödynnetään tällä hetkellä kaatopaikkakaasua 0,3 milj.m3 vuodessa. Biokaasua voitaisiin tuottaa Lappeenrannassa mädättämällä bioperäisiä jätteitä ja biokaasuntuotantoa varten kasvatettuja energiakasveja. Biokaasuntuotantoon soveltuvia jätteitä ovat erilliskerätty biojäte, jätevedenpuhdistamon jätevesiliete, puutarhajäte, lietelannat ja oljet. Kesannolla olevilla peltoaloilla voitaisiin kasvattaa ruokohelpeä. Biokaasun tuotantoon soveltuvia materiaaleja voitaisiin kerätä 143 000 t/a ja kasvattaa 68 000 t/a. Työssä tarkastellaan vaihtoehtoa, jossa mädätetään vain puhdistamoliete, sekä useita materiaaleja mädättävää yhteismädättämöä, johon liittyen tutkitaan kolmea eri vaihtoehtoa: kunnallisen jätteen mädätystä, kaiken jätteen mädätystä ja jätteen sekä energiakasvien mädätystä. Paras sijoituspaikka mädättämölle olisi jätevedenpuhdistamon läheisyydessä. Jätemateriaalista saataisiin kaasua enintään 12 milj. m3 ja energiakasveista enintään 16 milj. m3. Kaasusta voitaisiin tuottaa energiaa CHP-laitoksessa enintään 184 GWh. Mikäli biokaasun tuotannolla halutaan ensisijaisesti vähentää kasvi-huonekaasupäästöjä, kannattaa kaasu jalostaa ajoneuvopolttoaineeksi. Jalostettu kaasu on mahdollista myös syöttää maakaasuverkostoon. Suurimmat tulot on mahdollista saavuttaa yhdistetyssä sähkön- ja lämmöntuotannossa, mikäli biokaasulle suunniteltu syöttötariffi toteutuu. Muussa tapauksessa suurimmat tulot saadaan jalostamalla biokaasua ajoneuvojen polttoaineeksi.
Resumo:
Työssä käytiin läpi Porvoon jalostamon haihtuvien orgaanisten yhdisteiden päästömääritysmenetelmiä ja arvioitiin nykyisin käytössä olevien sekä uusien menetelmien soveltuvuutta Porvoon jalostamon päästömääritykseen. Nykyisten menetelmien arviointia tehtiin käymällä läpi eri alueiden 2000-luvun päästömäärät sekä vertaamalla päästömääriä muiden jalostamojen vastaaviin päästömääriin. Haihtuvista orgaanisista yhdisteistä puhuttaessa jätetään yleisesti metaani määritelmän ulkopuolelle ja käytetään termiä NMVOC-yhdisteet. Työssä laskettiin arvio Porvoon jalostamon metaanin päästömäärälle ja arvioitiin sen vaikutusta NMVOC-kokonaispäästömäärään. Metaanin kokonaispäästömäärien havaittiin olevan noin kymmenen kertaa haihtuvien orgaanisten yhdisteiden päästömääriä pienempiä, ja näin ollen niiden lisäämisellä NMVOC-päästöihin ei ole juuri vaikutusta. Myös menetelmien investointi- ja käyttökustannuksia, sekä pidemmän aikavälin kustannuksia arvioitiin. Kustannuksiltaan tällä hetkellä Porvoon jalostamolla käytössä olevat menetelmät ovat kustannustehokkaita. Uusista menetelmistä DIAL, SOF ja OGI ovat kustannuksiltaan huomattavasti kalliimpia, myös pitkän aikavälin vertailulla. Nykyisten menetelmien vuosittaiset kustannukset aiheutuvat mittausten vaatimista henkilötyötunneista. Uusista menetelmistä SOF ja DIAL vaativat ulkopuolisten mittaajien käyttämistä. Massavirran määrityksen suhteen vielä kehitysvaiheessa olevalla OGI-kameralla mitatessa voidaan käyttää mittaajina omaa henkilökuntaa. Toisin kuin DIAL- ja SOF-menetelmien laitteistot, OGI-kamera ostetaan omaksi ja näin ollen sitä voidaan käyttää tarpeen vaatiessa vuoden ympäri esimerkiksi suurien vuotajien paikallistamiseen ja LDAR-kiristysohjelman tukena. Tarkastelun perusteella olisi suositeltavaa tarkastaa nykyisin käytettävistä laskentamenetelmistä erityisesti prosessi- ja säiliöalueen sekä jätevesijärjestelmä päästömäärät käyttäen tarkempia DIAL-, SOF- tai myöhemmin OGI-menetelmiä ja muokata laskentamenetelmiä vastamaan näillä määritettyjä päästömääriä.