896 resultados para EQUIPMENT AND SUPPLIES


Relevância:

90.00% 90.00%

Publicador:

Resumo:

In 2002, AFL Queensland and the Brisbane Lions Football Club approached the Department of Primary Industries and Fisheries (Queensland) for advice on improving their Premier League sports fields. They were concerned about player safety and dissatisfaction with playing surfaces, particularly uneven turf cover and variable under-foot conditions. They wanted to get the best from new investments in ground maintenance equipment and irrigation infrastructure. Their sports fields were representative of community-standard, multi-use venues throughout Australia; generally ‘natural’ soil fields, with low maintenance budgets, managed by volunteers. Improvements such as reconstruction, drainage, or regular re-turfing are generally not affordable. Our project aimed to: (a) Review current world practice and performance benchmarks; (b) Demonstrate best-practice management for community-standard fields; (c) Adapt relevant methods for surface performance testing; (d) Assess current soils, and investigate useful amendments; (e) Improve irrigation system performance; and (e) Build industry capacity and encourage patterns for ongoing learning. Most global sports field research focuses on elite, sand-based fields. We adjusted elite standards for surface performance (hardness, traction, soil moisture, evenness, sward cover/height) and maintenance programs, to suit community-standard fields with lesser input resources. In regularly auditing ground conditions across 12 AFLQ fields in SE QLD, we discovered surface hardness (measured by Clegg Hammer) was the No. 1 factor affecting player safety and surface performance. Other important indices were turf coverage and surface compaction (measured by penetrometer). AFLQ now runs regularly audits affiliated fields, and closes grounds with hardness readings greater than 190 Gmax. Aerating every two months was the primary mechanical practice improving surface condition and reducing hardness levels to < 110 Gmax on the renovated project fields. With irrigation installation, these fields now record surface conditions comparable to elite fields. These improvements encouraged many other sporting organisations to seek advice / assistance from the project team. AFLQ have since substantially invested in an expanded ground improvement program, to cater for this substantially increased demand. In auditing irrigation systems across project fields, we identified low maintenance (with < 65% of sprinklers operating optimally) as a major problem. Retrofitting better nozzles and adjusting sprinklers improved irrigation distribution uniformity to 75-80%. Research showed that reducing irrigation frequency to weekly, and preparedness to withhold irrigation longer after rain, reduced irrigation requirement by 30-50%, compared to industry benchmarks of 5-6 ML/ha/annum. Project team consultation with regulatory authorities enhanced irrigation efficiency under imposed regional water restrictions. Laboratory studies showed incorporated biosolids / composts, or topdressed crumb rubber, improved compaction resistance of soils. Field evaluations confirmed compost incorporation significantly reduced surface hardness of high wear areas in dry conditions, whilst crumb rubber assisted turf persistence into early winter. Neither amendment was a panacea for poor agronomic practices. Under the auspices of the project Trade Mark Sureplay®, we published > 80 articles, and held > 100 extension activities involving > 2,000 participants. Sureplay® has developed a multi-level curator training structure and resource materials, subject to commercial implementation. The partnerships with industry bodies (particularly AFLQ), frequent extension activities, and engagement with government/regulatory sectors have been very successful, and are encouraged for any future work. Specific aspects of sports field management for further research include: (a) Understanding of factors affecting turf wear resistance and recovery, to improve turf persistence under wear; (b) Simple tests for pinpointing areas of fields with high hardness risk; and (c) Evaluation of new irrigation infrastructure, ‘water-saving’ devices, and irrigation protocols, in improving water use and turf cover outcomes.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

This research project investigated a bioreactor system capable of high density cell growth intended for use in regenerative medicine and protein production. The bioreactor was based on a drip-perfusion concept and constructed with minimal costs, readily available components, and straightforward processes for usage. This study involved the design, construction, and testing of the bioreactor where the results showed promising three dimensional cell growth within a polymer structure. The accessibility of this equipment and the capability of high density, three dimensional cell growth would be suitable for future research in pharmaceutical drug manufacturing, and human organ and tissue regeneration.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Malnutrition and poor nutritional intake have been identified as key issues associated with poorer clinical outcomes in chronic obstructive pulmonary disease (COPD) patients. There is strong evidence showing nutritional support is effective in treating malnutrition in stable COPD, but there is only limited research regarding nutritional status in patients treated with noninvasive ventilation (NIV). The impact of NIV during acute exacerbations of respiratory disease on nutritional status requires further investigation.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Accurate characterization and reporting of organic photovoltaic (OPV) device performance remains one of the important challenges in the field. The large spread among the efficiencies of devices with the same structure reported by different groups is significantly caused by different procedures and equipment used during testing. The presented article addresses this issue by offering a new method of device testing using “suitcase sample” approach combined with outdoor testing that limits the diversity of the equipment, and a strict measurement protocol. A round robin outdoor characterization of roll-to-roll coated OPV cells and modules conducted among 46 laboratories worldwide is presented, where the samples and the testing equipment were integrated in a compact suitcase that served both as a sample transportation tool and as a holder and test equipment during testing. In addition, an internet based coordination was used via plasticphotovoltaics.org that allowed fast and efficient communication among participants and provided a controlled reporting format for the results that eased the analysis of the data. The reported deviations among the laboratories were limited to 5% when compared to the Si reference device integrated in the suitcase and were up to 8% when calculated using the local irradiance data. Therefore, this method offers a fast, cheap and efficient tool for sample sharing and testing that allows conducting outdoor measurements of OPV devices in a reproducible manner.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Gastric motility disorders, including delayed gastric emptying (gastroparesis), impaired postprandial fundic relaxation, and gastric myoelectrical disorders, can occur in type 1 diabetes, chronic renal failure, and functional dyspepsia (FD). Symptoms like upper abdominal pain, early satiation, bloating, nausea and vomiting may be related to gastroparesis. Diabetic gastroparesis is related to autonomic neuropathy. Scintigraphy is the gold standard in measuring gastric emptying, but it is expensive, requires specific equipment, and exposes patients to radiation. It also gives information about the intragastric distribution of the test meal. The 13C-octanoic acid breath test (OBT) is an alternative, indirect method of measuring gastric emptying with a stable isotope. Electrogastrography (EGG) registers the slow wave originating in the pacemaker area of the stomach and regulating the peristaltic contractions of the antrum. This study compares these three methods of measuring gastric motility in patients with type 1 diabetes, functional dyspepsia, and chronic renal failure. Currently no effective drugs for treating gastric motility disorders are available. We studied the effect of nizatidine on gastric emptying, because in preliminary studies this drug has proven to have a prokinetic effect due to its cholinergic properties. Of the type 1 patients, 26% had delayed gastric emptying of solids as measured by scintigraphy. Abnormal intragastric distribution of the test meal occurred in 37% of the patients, indicating impaired fundic relaxation. The autonomic neuropathy score correlated positively with the gastric emptying rate of solids (P = 0.006), but HbA1C, plasma glucose levels, or abdominal symptoms were unrelated to gastric emptying or intragastric distribution of the test meal. Gastric emptying of both solids and liquids was normal in all FD patients but abnormal intragastric distribution occurred in 38% of the patients. Nizatidine improved symptom scores and quality of life in FD patients, but not significantly. Instead of enhancing, nizatidine slowed gastric emptying in FD patients (P < 0.05). No significant difference appeared in the frequency of the gastric slow waves measured by EGG in the patients and controls. The correlation between gastric half-emptying times of solids measured by scintigraphy and OBT was poor both in type 1 diabetes and FD patients. According to this study, dynamic dual-tracer scintigraphy is more accurate than OBT or EGG in measuring gastric emptying of solids. Additionally it provides information about gastric emptying of liquids and the intragastric distribution of the ingested test meal.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Purpose: The aim of the present study was to develop and test new digital imaging equipment and methods for diagnosis and follow-up of ocular diseases. Methods: The whole material comprised 398 subjects (469 examined eyes), including 241 patients with melanocytic choroidal tumours, 56 patients with melanocytic iris tumours, 42 patients with diabetes, a 52-year old patient with chronic phase of VKH disease, a 30-year old patient with an old blunt eye injury, and 57 normal healthy subjects. Digital 50° (Topcon TRC 50 IA) and 45° (Canon CR6-45NM) fundus cameras, a new handheld digital colour videocamera for eye examinations (MediTell), a new subtraction method using the Topcon Image Net Program (Topcon corporation, Tokyo, Japan), a new method for digital IRT imaging of the iris we developed, and Zeiss photoslitlamp with a digital camera body were used for digital imaging. Results: Digital 50° red-free imaging had a sensitivity of 97.7% and two-field 45° and 50° colour imaging a sensitivity of 88.9-94%. The specificity of the digital 45°-50° imaging modalities was 98.9-100% versus the reference standard and ungradeable images that were 1.2-1.6%. By using the handheld digital colour video camera only, the optic disc and central fundus located inside 20° from the fovea could be recorded with a sensitivity of 6.9% for detection of at least mild NPDR when compared with the reference standard. Comparative use of digital colour, red-free, and red light imaging showed 85.7% sensitivity, 99% specificity, and 98.2 % exact agreement versus the reference standard in differentiation of small choroidal melanoma from pseudomelanoma. The new subtraction method showed growth in four of 94 melanocytic tumours (4.3%) during a mean ±SD follow-up of 23 ± 11 months. The new digital IRT imaging of the iris showed the sphincter muscle and radial contraction folds of Schwalbe in the pupillary zone and radial structural folds of Schwalbe and circular contraction furrows in the ciliary zone of the iris. The 52-year-old patient with a chronic phase of VKH disease showed extensive atrophy and occasional pigment clumps in the iris stroma, detachment of the ciliary body with severe ocular hypotony, and shallow retinal detachment of the posterior pole in both eyes. Infrared transillumination imaging and fluorescein angiographic findings of the iris showed that IR translucence (p=0.53), complete masking of fluorescence (p=0.69), presence of disorganized vessels (p=0.32), and fluorescein leakage (p=1.0) at the site of the lesion did not differentiate an iris nevus from a melanoma. Conclusions: Digital 50° red-free and two-field 50° or 45° colour imaging were suitable for DR screening, whereas the handheld digital video camera did not fulfill the needs of DR screening. Comparative use of digital colour, red-free and red light imaging was a suitable method in the differentiation of small choroidal melanoma from different pseudomelanomas. The subtraction method may reveal early growth of the melanocytic choroidal tumours. Digital IRT imaging may be used to study changes of the stroma and posterior surface of the iris in various diseases of the uvea. It contributed to the revealment of iris atrophy and serous detachment of the ciliary body with ocular hypotony together with the shallow retinal detachment of the posterior pole as new findings of the chronic phase of VKH disease. Infrared translucence and angiographic findings are useful in differential diagnosis of melanocytic iris tumours, but they cannot be used to determine if the lesion is benign or malignant.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

This paper analyses the influence of management on Technical Efficiency Change (TEC) and Technological Progress (TP) in the communication equipment and consumer electronics sub-sectors of Indian hardware electronics industry. Each sub-sector comprises 13 sample firms for two time periods.The primary objective is to determine the relative contribution of TP and TEC to TFP Growth (TFPG) and to establish the influence of firm specific operational management decision variables on these two components. The study finds that both the sub-sectors have strived and achieved steady TP but not TEC in the period of economic liberalisation to cope with the intensifying competition. The management decisions with respect to asset and profit utilization, vertical integration, among others, improved TP and TE in the sub-sectors. However, R&D investments and technology imports proved costly for TFP indicating inadequate efforts and/or poor resource utilisation by the management. Management was found to be complacent in terms of improving or developing their own technology as indicated by their higher dependence on import of raw materials and no influence of R&D on TP.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Low-power electronic devices used in digital telecom exchanges are vulnerable to surge voltages and currents primarily originating from natural lightning or due to the direct interactions between electric power and telecommunication lines, etc., causing the earth/ground potential rise, neutral potential rise, and faults in the system. The fault currents may flow directly to telecom lines or through the equipment to the customer's premises, causing adequate damage to the equipment and personnel safety. In wireline applications, analog or digital, central office, exchanges, and subscriber sides have to be protected. Decisive protection and protective methods have to be employed for proper functioning of the equipment under overvoltage/overcurrent conditions. Current investigation reports some interesting results obtained on the recently developed high-voltage high-current protection cards used in digital telecom exchanges. The performances of protection cards both for the ring wave and hybrid wave surges are evaluated and presented. The surge generators required for the investigation are developed and fabricated in house as per the relevant telecom standards.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Contributed to: "Measuring the Changes": 13th FIG International Symposium on Deformation Measurements and Analysis; 4th IAG Symposium on Geodesy for Geotechnical and Structural Enginering (Lisbon, Portugal, May 12-15, 2008).

Relevância:

90.00% 90.00%

Publicador:

Resumo:

A new method of frequency-shifting for a diode laser is realized. Using a sample-and-hold circuit, the error signal can be held by the circuit during frequency shifting. It can avoid the restraint of locking or even lock-losing caused by the servo circuit when we input a step-up voltage into piezoelectric transition (PZT) to achieve laser frequency-shifting.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

It is often difficult to define ‘water quality’ with any degree of precision. One approach is that suggested by Battarbee (1997) and is based on the extent to which individual lakes have changed compared with their natural ‘baseline’ status. Defining the base-line status of artificial lakes and reservoirs however, is, very difficult. In ecological terms, the definition of quality must include some consideration of their functional characteristics and the extent to which these characteristics are self-sustaining. The challenge of managing lakes in a sustainable way is particularly acute in semi-arid, Mediterranean countries. Here the quality of the water is strongly influenced by the unpredictability of the rainfall as well as year-to-year variations in the seasonal averages. Wise management requires profound knowledge of how these systems function. Thus a holistic approach must be adopted and the factors influencing the seasonal dynamics of the lakes quantified over a range of spatial and temporal scales. In this article, the authors describe some of the ways in which both long-term and short-term changes in the weather have influenced the seasonal and spatial dynamics of phytoplankton in El Gergal, a water supply reservoir situated in the south of Spain. The quality of the water stored in this reservoir is typically very good but surface blooms of algae commonly appear during warm, calm periods when the water level is low. El Gergal reservoir is managed by the Empresa Municipal de Abastecimiento y Saneamiento (EMASESA) and supplies water for domestic, commercial and industrial use to an area which includes the city of Seville and twelve of its surrounding towns (ca. 1.3 million inhabitants). El Gergal is the last of two reservoirs in a chain of four situated in the Rivera de Huelva basin, a tributary of the Guadalquivir river. It was commissioned by EMASESA in 1979 and since then the company has monitored its main limnological parameters on, at least, a monthly basis and used this information to improve the management of the reservoir. As a consequence of these intensive studies the physical, chemical and biological information acquired during this period makes the El Gergal database one of the most complete in Spain. In this article the authors focus on three ‘weather-related’ effects that have had a significant impact on the composition and distribution of phytoplankton in El Gergal: (i) the changes associated with severe droughts; (ii) the spatial variations produced by short-term changes in the weather; (iii) the impact of water transfers on the seasonal dynamics of the dinoflagellate Ceratium.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Presented here is another in the list of historic accounts of iconic research cruises of the USFC Steamer Albatross, this a reminiscence of the renowned scientist Alexander Agassiz edited by his son G. R. Agassiz, a chapter from the volume “Letters and Recollections of Alexander Agassiz,” published in 1913. Agassiz made three major cruises in the Albatross in 1891, 1899–1900, and 1904–05, adding greatly to the world’s store of specimens and knowledge of thalasography, his favored term for oceangraphy, and specifically of the Pacific Ocean. Having made important cruises and studies with the Blake in the Caribbean, he sought to do comparable research in the Pacific. His opportunity came in 1890, and with the consent of President Benjamin Harrison, he took charge of this Albatross research cruise, paying much of the expense himself. In contrast with the other ships he had been on, he found the laboratories, equipment, and furnishings to be comparatively luxurious and extremely well appointed for his work. Further, the Albatross was then captained by Lieutenant Commander Zera Luther Tanner who seemed to take as much interest in the oceanographic research as did the scientists, and Agassiz appreciated working with him, too. Little of the original text has been altered, and readers are cautioned that some of the views expressed may reflect unfortunate prejudices of that era toward individuals, nationalities, etc.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

O objetivo deste trabalho foi avaliar a potencialidade de implantação da Produção Mais Limpa (P+L), através do estudo de caso em Laboratório Biomédico de Referência em uma instituição pública de ensino e pesquisa localizada no Rio de Janeiro. Esta investigação é exploratória e analítica, utilizando-se como instrumentos a revisão bibliográfica e documental, a observação direta e a entrevista com aplicação de questionários voltados aos responsáveis pela área ambiental do laboratório pesquisado. A análise foi realizada confrontando-se os dados levantados com as recomendações da metodologia de P+L, identificando-se as lacunas e oportunidades para a melhoria dos serviços e processos de trabalho. O laboratório possui instalações modernas, organização, sistemas de avaliação da matéria-prima e insumos usados, além do gerenciamento dos resíduos. Contudo, nem todos os procedimentos são validados ou estão adequados às normas. Em geral, problemas em laboratórios dizem respeito ao uso excessivo de substâncias perigosas e ao manejo inadequado de resíduos, o qual pode ser contornado com a P+L, tendo como enfoque a prevenção da poluição e a minimização na fonte geradora. A redução do consumo de materiais e insumos, além da implantação de mudanças nos processos de trabalho, podem diminuir os custos financeiros e os impactos ambientais, como foi demonstrado no estudo. Para a melhoria da gestão dos laboratórios, recomenda-se a continuidade na aquisição, manutenção de equipamentos e infraestrutura. É importante a divulgação de informações ambientais e treinamento permanente para funcionários e alunos. A Sustentabilidade Ambiental só pode ser alcançada quando for bem entendida e absorvida por todos, sendo a alta administração das instituições a maior responsável para liderar esse processo. Para estudos futuros, propõe-se melhor definição e ampliação dos indicadores para o monitoramento e aprimoramento da gestão ambiental. Complementarmente, indicam-se estudos sobre a aquisição de conceitos pelos atores sobre a P+L e como eles podem contribuir com a Sustentabilidade Ambiental e a melhoria no ambiente de trabalho. Espera-se que esta pesquisa auxilie com o aperfeiçoamento da gestão no laboratório estudado e em instituições similares que a venham implantar a P+L.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Due to inadequacies of previous underwater towing techniques and the special needs of a recent underwater survey, a modified mania-board technique was developed. With this new technique, the diver holds on to the manta-board with one arm; consequently, the board is referred to as a single-armed manta-board (sam-board). The sam-board proved inexpensive and highly maneuverable, allowing the divers to freely collect samples or record information. Through some experimenting with the board and changing some of the variables, such as rope lengths, towing speeds, etc., a highly efficient towing method can be achieved. Preplanning and strict diving safety procedures must, however, be implemented to assure efficiency. This paper presents the materials, guidelines for board construction, equipment, and preplanning and diving safety procedures necessary for the sam-board towing operation.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

We have recently exchanged and integrated into a single database tag detections for conch, teleost and elasmobranch fish from four separately maintained arrays in the U.S. Virgin Islands including the NMFS queen conch array (St. John nearshore), NOAA’s Biogeography Branch array (St. John nearshore & midshelf reef); UVI shelf edge arrays (Marine Conservation District, Grammanik & other shelf edge); NOAA NMFS Apex Predator array COASTSPAN (St. John nearshore). The integrated database has over 7.5 million hits. Data is shared only with consent of partners and full acknowledgements. Thus, the summary of integrated data here uses data from NOAA and UVI arrays under a cooperative agreement. The benefits of combining and sharing data have included increasing the total area of detection resulting in an understanding of broader scale connectivity than would have been possible with a single array. Partnering has also been cost-effectiveness through sharing of field work, staff time and equipment and exchanges of knowledge and experience across the network. Use of multiple arrays has also helped in optimizing the design of arrays when additional receivers are deployed. The combined arrays have made the USVI network one of the most extensive acoustic arrays in the world with a total of 150+ receivers available, although not necessarily all deployed at all times. Currently, two UVI graduate student projects are using acoustic array data.