875 resultados para validação
Resumo:
This paper presents an application of AMMI models - Additive Main effects and Multiplicative Interaction model - for a thorough study about the effect of the interaction between genotype and environment in multi-environments experiments with balanced data. Two methods of crossed validation are presented and the improvement of these methods through the correction of eigenvalues, being these rearranged by the isotonic regression. A comparative study between these methods is made, with real data. The results show that the EASTMENT & KRZANOWSKI (1982) method selects a more parsimonious model and when this method is improved with the correction of the eigenvalues, the number of components are not modified. GABRIEL (2002) method selects a huge number of terms to hold back in the model, and when this method is improved by the correction of eigenvalue, the number of terms diminishes. Therefore, the improvement of these methods through the correction of eigenvalues brings a great benefit from the practical point of view for the analyst of data proceeding from multi-ambient, since the selection of numbers of multiplicative terms represents a profit of the number of blocks (or repetitions), when the model AMMI is used, instead of the complete model.
Resumo:
A eficiência de métodos para análise de 5-hidroximetilfurfural por cromatografia líquida de alta eficiência com detecção na região do ultravioleta e determinação de sacarose, glicose e frutose por cromatografia líquida com detecção por índice de refração foi avaliada. Após otimização das condições analíticas, os principais parâmetros de validação (linearidade, limite de quantificação, limite de detecção, recuperação, sensibilidade e precisão) foram determinados e demonstraram que os procedimentos analíticos podem ser aplicados para o controle do processo de produção de poli(3-hidroxibutirato).
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
FUNDAMENTO: A medida precisa da pressão arterial é fundamental para a investigação científica ou decisão clínica. Nesse sentido, é importante verificar valores fornecidos por equipamentos eletrônicos. OBJETIVO: Validar o monitor Omron HEM 742 de medida de pressão arterial em adolescentes, segundo os critérios sugeridos pela British Hypertension Society. MÉTODOS: Participaram do estudo 150 adolescentes com idades entre 10 e 16 anos. O monitor automático Omron HEM 742 foi conectado em Y com equipamento auscultatório de coluna de mercúrio, e realizaram-se três avaliações simultâneas, calculando-se as diferenças entre os dois equipamentos. Para verificar a relação entre ambos, utilizaram-se o coeficiente de correlação intraclasse e a plotagem de Bland-Altman (concordância). A especificidade e a sensibilidade do aparelho foram determinadas pela curva ROC. RESULTADOS: A comparação entre as medidas acusou uma diferença menor ou igual a 5 mmHg em 67,3% dos valores sistólicos e 69,3% dos valores diastólicos; uma diferença menor ou igual a 10 mmHg ocorreu em 87,3% e 90,6% dos valores sistólicos e diastólicos, respectivamente; e uma diferença menor ou igual a 15 mmHg em 96,6% dos valores sistólicos e 97,3% dos diastólicos. Esses resultados indicam grau A segundo o protocolo da British Hypertension Society. Observou-se ainda elevada concordância nos valores obtidos por meio do monitor automático, e verificou-se que esse equipamento é capaz de identificar a presença ou a ausência da pressão arterial elevada. CONCLUSÃO: O monitor Omron HEM 742 mostrou-se válido para medidas de pressão arterial em adolescentes, conforme os critérios sugeridos pela British Hypertension Society.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Nas últimas décadas, a produção de suínos, pressionada por uma crescente demanda por alimentos, tem-se caracterizado pela maior concentração de animais em grandes unidades de produção, dificultando o registro dos dados individuais. Os sistemas automáticos de identificação eletrônica podem auxiliar a detecção de doenças, a avaliação de respostas fisiológicas, o controle de ingestão de alimentos, a atividade física e ainda o impacto ambiental causado pelo sistema de produção, promovendo melhor controle da propriedade. Transponders injetáveis, brincos eletrônicos e o monitoramento por meio da análise de imagem estão sendo utilizados no processo de identificação. O objetivo desta pesquisa foi avaliar os diferentes locais de implante subcutâneo de microchips em leitões, verificando-se possíveis infecções e/ou rejeições, migrações dos microchips em relação ao local de implante e sua validação em relação à análise de imagem.
Resumo:
The efficiency of two methods for determining 3-hydroxybutyrate and 3-hydroxyvalerate content in the biopolymer (poly(3-hydroxybutyrate-co-3-hydroxyvalerate) has been evaluated. Both methods are based on (a) the hydrolysis of polymers, (b) the esterification with methyl (method A) and isoamilic alcohol (method B) and (c) analysis of the esters by gas chromatography using flame ionization detection (GC-FID). After optimization of the analytical conditions, the main validation parameters (linearity, quantification limit, detection limit, recovery, sensitivity and precision) were determined showing that both analytical procedures can be applied to control the process of poly(3-hydroxybutyrate) production. However, method B gives better analytical results than method A and has the advantage of not using chlorinated solvents.
Resumo:
The present article deals with the adaptation of the Moral Judgment Test (MJT) for the Portuguese language. The principles of the test, its format and the process of content, construct and criterion validation are presented. In the same way, reliability is discussed using Brazilian research results that produced the necessity of elaborating another dilemma to compose the MJT-xt (extended).
Resumo:
Due necessity of better understanding leptin and reproduction relations, a specific radioimmunoassay (RIA) to bovine leptin was avalidated. First, an antibody production protocol was developed using recombinant equine leptin inoculated in a rabbit, that results in 28,05% of maximum binding (MB) 105 days after the protocol beginning. The tests of validations verified parallelism between standard curve and dilutions of high and low controls (P < 0,01). Antibody against equine leptin showed specificity to bovine leptin (P < 0,01). The recuperation tax of bovine leptin by antibody against recombinant equine leptin was from 98,4 to 101,6% (P < 0, 01). When the samples were stored in ambient temperature or refrigerated to 4°C, ligation stability was verified (P > 0,2), however, temperatures above 37°C impaired the bovine leptin recuperation. The use of assay buffer with or without bovine plasma did not show any difference (P > 0,3). These results showed that the antibody produced in rabbit against equine leptin were able to detect plasmatic bovine leptin, and that the RIA to bovine leptin quantification had adequate characteristics to the development of a valid assay.
Resumo:
Triamcinolone (TRI), a drug widely used in the treatment of ocular inflammatory diseases, is practically insoluble in water, which limits its use in eye drops. Cyclodextrins (CDs) have been used to increase the solubility or dissolution rate of drugs. The purpose of the present study was to validate a UV-Vis spectrophotometric method for quantitative analysis of TRI in inclusion complexes with beta-cyclodextrin (B-CD) associated with triethanolamine (TEA) (ternary complex). The proposed analytical method was validated with respect to the parameters established by the Brazilian regulatory National Agency of Sanitary Monitoring (ANVISA). The analytical measurements of absorbance were made at 242nm, at room temperature, in a 1-cm path-length cuvette. The precision and accuracy studies were performed at five concentration levels (4, 8, 12, 18 and 20μg.mL -1). The B-CD associated with TEA did not provoke any alteration in the photochemical behavior of TRI. The results for the measured analytical parameters showed the success of the method. The standard curve was linear (r2 > 0.999) in the concentration range from 2 to 24 μg.mL -1. The method achieved good precision levels in the inter-day (relative standard deviation-RSD <3.4%) and reproducibility (RSD <3.8%) tests. The accuracy was about 80% and the pH changes introduced in the robustness study did not reveal any relevant interference at any of the studied concentrations. The experimental results demonstrate a simple, rapid and affordable UV-Vis spectrophotometric method that could be applied to the quantitation of TRI in this ternary complex.
Resumo:
Pós-graduação em Alimentos e Nutrição - FCFAR