781 resultados para skull suture


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This research presents a new design of an adjustable suture that could provide a better intraocular pressure (IOP) control in the post treatment of trabeculectomy surgery and limit associated complication with the current suturing techniques. A better control in tension suture brings a great deal of advantages to this surgical technique compared with the traditional adjustable suture. A length adjustment can be added in advance to a 10-0 nylon suture which enables suture tension to be released during the postoperative period of trabeculectomy surgery. This adjustment has a D-ring geometry made of 10-0 nylon suture adhered to a 10-0 nylon surgical suture which is used to close the scalar flap. The D ring was adhered with about 180 microdroplet of Loctite 4311that was found to form a strong joint to connect the D ring to the main 10-0 nylon suture and strong enough to carry the added tension instead after cutting the central suture between the two joints of the D ring. The geometry of adjustment is the key factor of maintaining the IOP at the normal range and keeping the scleral flap tight enough and secure so that aqueous humor continues to percolate under the subconjunctiva. It has been found that a 365, and 450 µm length extensions can release suture tension postoperatively and relieve the intraocular pressure within the eye by 33, and 66% respectively. The fabrication process of the new adjustable suture was divided into two steps: fabrication of micro jig and forming microdroplets. A micro jig was fabricated in order to form and bond a precise length extension to the new design of the adjustable suture. In addition, a new liquid separation technique has been followed in this study in order to generate micro adhesive droplets as small as 50µm for bonding the new adjustable suture structure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim. Circumcision is the most common procedure for phimosis. In recent years, the value of foreskin properties as well as aesthetic reasons determined to other operations preserving the foreskin. We report 5-years experience with a technique that preserve the physical foreskin appearance intact. Patients and methods. Fifty-two patients, eligible to undergo phimosis surgery, underwent prepuce-sparing plasty and simple running suture. Evaluation of results was made with photos comparative and verified by using presence/absence of recurrence, scarring evaluation, and VAS for patient satisfaction. Results. Forty-eight patients reported no complications. There were no cases of bleeding, infection, pathological scarring, phimosis recurrence. The scar showed a good pliability and a thin thickness. Patient satisfaction was high. Conclusions. The association of prepuce-sparing plasty and simple running suture highlighted an effective and easy method for the correction of acquired phimosis in adult patients, with excellent functional and cosmetic results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Rapport présenté en vue de l’obtention du grade de M.Sc.A génie biomédical option génie clinique

Relevância:

20.00% 20.00%

Publicador:

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The periosteum plays an indispensable role in both bone formation and bone defect healing. In this study we constructed an artificial in vitro periosteum by incorporating osteogenic differentiated bone marrow stromal cells (BMSCs) and cobalt chloride (CoCl(2))-treated BMSCs. The engineered periostea were implanted both subcutaneously and into skull bone defects in SCID mice to investigate ectopic and orthotopic osteogenesis and vascularization. After two weeks in subcutaneous and four weeks in bone defect areas, the implanted constructs were assessed for ectopic and orthotopic osteogenesis and vascularization by micro-CT, histomorphometrical and immunohistochemical methods. The results showed that CoCl(2) pre-treated BMSCs induced higher degree of vascularization and enhanced osteogenesis within the implants in both ectopic and orthotopic areas. This study provided a novel approach using BMSCs sourced from the same patient for both osteogenic and pro-angiogenic purposes in constructing tissue engineered periosteum to enhance vascularized osteogenesis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Consider a person searching electronic health records, a search for the term ‘cracked skull’ should return documents that contain the term ‘cranium fracture’. A information retrieval systems is required that matches concepts, not just keywords. Further more, determining relevance of a query to a document requires inference – its not simply matching concepts. For example a document containing ‘dialysis machine’ should align with a query for ‘kidney disease’. Collectively we describe this problem as the ‘semantic gap’ – the difference between the raw medical data and the way a human interprets it. This paper presents an approach to semantic search of health records by combining two previous approaches: an ontological approach using the SNOMED CT medical ontology; and a distributional approach using semantic space vector space models. Our approach will be applied to a specific problem in health informatics: the matching of electronic patient records to clinical trials.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives: The periosteum plays an indispensable role in both bone formation and bone defect healing. The aim of this project is to produce tissue engineered periosteum for bone defect treatment. Methods: In this study we constructed an artificial in vitro periosteum by incorporating osteogenic differentiated bone marrow stromal cells (BMSCs) and cobalt chloride (CoCl2)-treated BMSCs. The engineered periostea were implanted both subcutaneously and into skull bone defects in SCID mice to investigate ectopic and orthotopic osteogenesis and vascularisation. After two weeks in subcutaneous and four weeks in bone defect areas, the implanted constructs were assessed for ectopic and orthotopic osteogenesis and vascularisation by micro-CT, histomorphometrical and immunohistochemical methods. Results: The results showed that CoCl2 pre-treated BMSCs induced higher degree of vascularisation and enhanced osteogenesis within the implants in both ectopic and orthotopic areas. Conclusion: This study provided a novel approach using BMSCs sourced from the same patient for both osteogenic and pro-angiogenic purposes in constructing tissue engineered periosteum to enhance vascularized osteogenesis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: Regeneration of osseous defects by tissue-engineering or cell delivery approach provides a novel means of treatment utilizing cell biology, materials sciences, and molecular biology. The concept of in vitro explanted mesenchymal stem cells (MSCs) with an ability to induce new bone formation has been demonstrated in some small animal models. However, contradictory results have been reported regarding the regenerative capacity of MSCs after ex vivo expansion due to the lack of the understanding of microenvironment for MSC differentiation in vivo. ----- ----- Methods: In our laboratory tissue-derived and bone marrow-derived MSCs have been investigated in their osteogenesis. Cell morphology and proliferation were studied by microscopy, confocal microscopy, FACS and cell counting. Cell differentiation and matrix formation were analysed by matrix staining, quantitative PCR, and immunohistochemistry. A SCID skull defect model was used for cell transplantation studies.----- ----- Results: It was noted that tissue-derived and bone marrow-derived MSCs showed similar characteristics in cell surface marker expression, mesenchymal lineage differentiation potential, and cell population doubling. MSCs from both sources could initiate new bone formation in bone defects after delivery into a critical size defects. The bone forming cells were from both transplanted cells and endogenous cells from the host. Interestingly, the majority of in vitro osteogenic differentiated cells did not form new bone directly even though mineralized matrix was synthesized in vitro by MSCs. Furthermore, no new bone formation was detected when MSCs were transplanted subcutaneously.----- ----- Conclusion: This study unveiled the limitations of MSC delivery in bone regeneration and proposed that in vivo microenvironment needs to be optimized for MSC delivery in osteogenesis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction and aims: For a scaffold material to be considered effective and efficient for tissue engineering it must be biocompatible as well as bioinductive. Silk fiber is a natural biocompatible material suitable for scaffold fabrication; however, silk is tissue-conductive and lacks tissue-inductive properties. One proposed method to make the scaffold tissue-inductive is to introduce plasmids or viruses encoding a specific growth factor into the scaffold. In this study, we constructed adenoviruses encoding bone morphogenetic protein-7 (BMP-7) and incorporated these into silk scaffolds. The osteo-inductive and new bone formation properties of these constructs were assessed in vivo in a critical-sized skull defect animal model. Materials and methods: Silk fibroin scaffolds containing adenovirus particles coding BMP-7 were prepared. The release of the adenovirus particles from the scaffolds was quantified by tissue-culture infective dose (TCID50) and the bioactivity of the released viruses was evaluated on human bone marrow mesenchymal stromal cells (BMSCs). To demonstrate the in vivo bone forming ability of the virus-carrying silk fibroin scaffold, the scaffold constructs were implanted into calvarial defects in SCID mice. Results: In vitro studies demonstrated that the virus-carrying silk fibroin scaffold released virus particles over a 3 week period while preserving their bioactivity. In vivo test of the scaffold constructs in critical-sized skull defect areas revealed that silk scaffolds were capable of delivering the adenovirus encoding BMP-7, resulting significantly enhanced new bone formation. Conclusions: Silk scaffolds carrying BMP-7 encoding adenoviruses can effectively transfect cells and enhance both in vitro and in vivo osteogenesis. The findings of this study indicate silk fibroin is a promising biomaterial for gene delivery to repair critical-sized bone defects.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The final shape of the "Internet of Things" ubiquitous computing promises relies on a cybernetic system of inputs (in the form of sensory information), computation or decision making (based on the prefiguration of rules, contexts, and user-generated or defined metadata), and outputs (associated action from ubiquitous computing devices). My interest in this paper lies in the computational intelligences that suture these positions together, and how positioning these intelligences as autonomous agents extends the dialogue between human-users and ubiquitous computing technology. Drawing specifically on the scenarios surrounding the employment of ubiquitous computing within aged care, I argue that agency is something that cannot be traded without serious consideration of the associated ethics.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The interaction between host and donor cells is believed to play an important role in osteogenesis. However, it is still unclear how donor osteogenic cells behave and interact with host cells in vivo. The purpose of this study was to track the interactions between transplanted osteogenic cells and host cells during osteogenesis. In vitro migration assay was carried out to investigate the ability of osteogenic differentiated humanmesenchymal stemcells (O-hMSCs) to recruit MSCs. At the in vivo level, O-hMSCs were implanted subcutaneously or into skull defects in severe combined immunodeficient (SCID) mice. New bone formation was observed bymicro-CT and histological procedures. In situ hybridization (ISH) against human Alu sequences was performed to distinguish donor osteogenic cells from host cells. In vitro migration assay revealed an increased migration potential of MSCs by co-culturing with O-hMSCs. In agreement with the results of in vitro studies, ISH against human Alu sequences showed that host mouse MSCs migrated in large numbers into the transplantation site in response to O-hMSCs. Interestingly, host cells recruited by O-hMSCs were the major cell populations in newly formed bone tissues, indicating that O-hMSCs can trigger and initiate osteogenesis when transplanted in orthotopic sites. The observations fromthis study demonstrated that in vitro induced O-hMSCs were able to attract hostMSCs in vivo andwere involved inosteogenesis togetherwith host cells,whichmay be of importance for bone tissue-engineering applications.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Scaffolds for bone tissue engineering should be designed to optimize cell migration, enhance new bone formation and give mechanical support. In the present study, we used polycaprolactone-tricalciumphosphate (PCL/TCP) scaffolds with two different fibre lay down patterns which were coated with hydroxyapatite and gelatine as an approach for optimizing bone regeneration in a critical sized calvarial defect. After 12 weeks bone regeneration was quantified using microCT analysis, biomechanical testing and histological evaluation. Notably, the experimental groups containing coated scaffolds showed lower bone formation and lower biomechanical properties within the defect compared to the uncoated scaffolds. Surprisingly, the different lay down pattern of the fibres resulted in different bone formation and biomechanical properties; namely 0/60/120° scaffolds revealed lower bone formation and biomechanical properties compared to the 0/90° scaffolds in all the experimental groups. The different architecture of the scaffold fibres may have an effect on nutrition supply as well as the attachment of the newly formed matrix to the scaffold. Therefore, future bone regeneration strategies utilising scaffolds should consider scaffold architecture as an important factor during the scaffold optimisation stages in order to move closer to a clinical application.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Cardiovascular diseases are a leading cause of death throughout the developed world. With the demand for donor hearts far exceeding the supply, a bridge-to-transplant or permanent solution is required. This is currently achieved with ventricular assist devices (VADs), which can be used to assist the left ventricle (LVAD), right ventricle (RVAD), or both ventricles simultaneously (BiVAD). Earlier generation VADs were large, volume-displacement devices designed for temporary support until a donor heart was found. The latest generation of VADs use rotary blood pump technology which improves device lifetime and the quality of life for end stage heart failure patients. VADs are connected to the heart and greater vessels of the patient through specially designed tubes called cannulae. The inflow cannulae, which supply blood to the VAD, are usually attached to the left atrium or ventricle for LVAD support, and the right atrium or ventricle for RVAD support. Few studies have characterized the haemodynamic difference between the two cannulation sites, particularly with respect to rotary RVAD support. Inflow cannulae are usually made of metal or a semi-rigid polymer to prevent collapse with negative pressures. However suction, and subsequent collapse, of the cannulated heart chamber can be a frequent occurrence, particularly with the relatively preload insensitive rotary blood pumps. Suction events may be associated with endocardial damage, pump flow stoppages and ventricular arrhythmias. While several VAD control strategies are under development, these usually rely on potentially inaccurate sensors or somewhat unreliable inferred data to estimate preload. Fixation of the inflow cannula is usually achieved through suturing the cannula, often via a felt sewing ring, to the cannulated chamber. This technique extends the time on cardiopulmonary bypass which is associated with several postoperative complications. The overall objective of this thesis was to improve the placement and design of rotary LVAD and RVAD inflow cannulae to achieve enhanced haemodynamic performance, reduced incidence of suction events, reduced levels of postoperative bleeding and a faster implantation procedure. Specific objectives were: * in-vitro evaluation of LVAD and RVAD inflow cannula placement, * design and in-vitro evaluation of a passive mechanism to reduce the potential for heart chamber suction, * design and in-vitro evaluation of a novel suture-less cannula fixation device. In order to complete in-vitro evaluation of VAD inflow cannulae, a mock circulation loop (MCL) was developed to accurately replicate the haemodynamics in the human systemic and pulmonary circulations. Validation of the MCL’s haemodynamic performance, including the form and magnitude of pressure, flow and volume traces was completed through comparisons of patient data and the literature. The MCL was capable of reproducing almost any healthy or pathological condition, and provided a useful tool to evaluate VAD cannulation and other cardiovascular devices. The MCL was used to evaluate inflow cannula placement for rotary VAD support. Left and right atrial and ventricular cannulation sites were evaluated under conditions of mild and severe heart failure. With a view to long term LVAD support in the severe left heart failure condition, left ventricular inflow cannulation was preferred due to improved LVAD efficiency and reduced potential for thrombus formation. In the mild left heart failure condition, left atrial cannulation was preferred to provide an improved platform for myocardial recovery. Similar trends were observed with RVAD support, however to a lesser degree due to a smaller difference in right atrial and ventricular pressures. A compliant inflow cannula to prevent suction events was then developed and evaluated in the MCL. As rotary LVAD or RVAD preload was reduced, suction events occurred in all instances with a rigid inflow cannula. Addition of the compliant segment eliminated suction events in all instances. This was due to passive restriction of the compliant segment as preload dropped, thus increasing the VAD circuit resistance and decreasing the VAD flow rate. Therefore, the compliant inflow cannula acted as a passive flow control / anti-suction system in LVAD and RVAD support. A novel suture-less inflow cannula fixation device was then developed to reduce implantation time and postoperative bleeding. The fixation device was evaluated for LVAD and RVAD support in cadaveric animal and human hearts attached to a MCL. LVAD inflow cannulation was achieved in under two minutes with the suture-less fixation device. No leakage through the suture-less fixation device – myocardial interface was noted. Continued development and in-vivo evaluation of this device may result in an improved inflow cannulation technique with the potential for off-bypass insertion. Continued development of this research, in particular the compliant inflow cannula and suture-less inflow cannulation device, will result in improved postoperative outcomes, life span and quality of life for end-stage heart failure patients.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We provide a taxonomic redescription of the ubiquitous and variable dasyurid marsupial Yellow-footed Antechinus, Antechinus flavipes (Waterhouse), which comprises three currently recognized subspecies whose combined geographic distribution spans almost the length and breadth of Australia. A. flavipes leucogaster Gray is confined to south-west Western Australia; A. flavipes flavipes is distributed in south-eastern Australia across four states—South Australia, Victoria, New South Wales and Queensland; A. flavipes rubeculus Van Dyck is confined to the wet tropics of Queensland. A. flavipes is readily distinguished from all extant congeners based on external morphology by the following combination of features: a grey head; orange-yellow toned flanks/rump, feet and tail base; pale eye-rings and a darkened tail tip. A. flavipes skulls are stout, being broad at the level of the rear upper molars, have small palatal vacuities and small entoconid cusps on the lower molars. However, notable differences among subspecies of A. flavipesprevent any obvious collection of skull characters being diagnostic for species-level discrimination among congeners. A. flavipes rubeculus is the largest of the three subspecies of Yellow-footed Antechinus and most similar in skull morphology to A. leo, A. bellus and A. godmani—all four species are geographically limited to tropical Australia. A. f. rubeculus is notably larger in many characters than its conspecifics: A. f. flavipes, the next largest, and A. f. leucogaster, the smallest of the group. A. f. flavipes and A. f. leucogaster diverge significantly at only a few skull characters, and both subspecies have cranial morphological affinities with the recently discovered A. mysticus, most notably A. f. leucogaster. Phylogenies generated from mt- and nDNA data strongly support Antechinus flavipes as monophyletic with respect to other members of the genus; within A. flavipes, each of the three recognized subspecies form distinctive monophyletic clades.