In this work, a spectrophotometric flow injection analysis system using a crude extract of avocado (Persea americana) as a source of polyphenol oxidase to dopamine determination was developed. The substrates and enzyme concentrations from 2.4x10-7 to 5.3x10-4 mol L-1 and 28 to 332 units mL-1 were evaluated, respectively. In addition, the FIA parameters such as sample loop (50 to 500 µL), flow rate (1.4 to 4.3 mL min-1) and reactor length (100 to 500 cm) were also evaluated in a 0.1 mol L-1 phosphate buffer solution (pH 7.0). Dopamine solution concentrations were determined using 277 units mL-1 enzyme solution, 400 mL enzyme loop, 375 µL sample loop, 2.2 mL min-1 flow rate and a reactor of 350 cm. The analytical curve showed a linearity from 5.3x10-5 to 5.3x10-4 mol L-1 dopamine with a detection limit of 1.3x10-5 mol L-1. The analytical frequency was 46 h-1 and the RSD lower than 0.5% for 5.3x10-4 mol L-1 dopamine solution (n=10). A paired t-test showed that all results obtained for dopamine in commercial formulations using the proposed flow injection procedure and a spectrophotometric procedure agree at the 95% confidence level.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

In this work two procedures were proposed for analytical curves construction using a single standard solution employing a flow injection system with solid phase spectrophotometric detection (FI-SPS). A flow cell contends the chromogenic reagent 1-(2-tiazolylazo)-2-naphtol was positioned on the optical path. The first procedure was based on controlled concentration of analyte on solid phase and the relations between absorbance and the total volume of injected allowed the calculation of analyte concentration. The second procedure was developed employing controlled dispersion/retention in flow system where analyte concentration was obtained by exploiting the relation between transient signals of samples and single standard solution at equivalent reading time. The procedures were successfully applied for zinc determination in synthetic solutions with good precision and accuracy at 95% confidence level.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The work describes a new procedure for cetylpyridinium chloride determination in oral disinfectants, based on a flow-injection system with potentiometric detection. The determination was based on the measurement of picrate concentration decrease as result of ion-pair reaction with the analyte present in the injected sample. In the optimised set-up the sample injection volume was kept at 400 µL and merged downstream with the reagent solution containing 1,0 x10-5 mol/L of picrate adjusted to pH 5.0 with citrate/citric acid buffer. The flow rate was fixed at 8 mL/min and the reactor length at 40 cm. The proposed procedure enables the determination of cetylpyridinium in the analytical range of 5,0x10-6 - 7,5x10-5 mol/L at a sampling rate of 60/h. The results for real samples had a precision better than 3% and were comparable to the labelled values.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Automatic flow procedures based on the multicommutation concept, dedicated to the determination of 3-hydroxybutyrate, glucose and cholesterol are proposed. The enzymes were immobilized on glass beads and packed into mini-columns that were coupled to a flow system. Sampling throughputs of 55, 40 and 40 determinations per hour, linear response from 10 to 150, 50 to 600, 25 to 125 mg L-1, detection limits of 1.5, 14 and 4 mg L-1 and relative standard deviations of 1, 2 and 2% for 3-hydroxybutyrate, glucose and cholesterol, respectively, were achieved.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

A simple flow injection procedure was developed for determining dipyrone (1-phenyl-2,3-dimethyl-4-methylaminomethano-5-pyrazolone sodium, metamizol, analgin) in pharmaceutical formulations. The determination is based on the reduction of Ag+ ions to Ag0 by dipyrone. A colloidal suspension of Ag0 produced was transported by carrier solution (0.01 mol L-1 NaOH) and turbidimetrically detected at 425 nm. The analytical curve for dipyrone was linear in the range from 5.0 x 10-4 to 2.5 x 10-3 mol L-1 with a correlation coefficient of 0.9990. The detection limit was 1.3 x 10-4 mol L-1 (3sigmaB/slope). The relative standard deviation for ten successive measurements was 1.8% and an analytical frequency of 45 h-1 was obtained. The recovery values from three samples ranged from 96.0 to 102%.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

An indirect flow injection spectrophotometric procedure is proposed for the determination of N-acetyl-L-cysteine in pharmaceutical formulations. In this system, ferroin ([Fe(II)-(fen)2]2+) in excess, with a strong absorption at 500 nm, is oxidized by cerium(IV) yielding cerium(III) and [Fe(III)-(fen)2]3+ (colorless), thus producing a baseline. When N-acetyl-L-cysteine solution is introduced into the flow injection system, it reacts with cerium(IV) increasing the analytical signal in proportion to the drug concentration. Under optimal experimental conditions, the linearity of the analytical curve for N-acetyl-L-cysteine ranged from 6.5x10-6 to 1.3x10-4 mol L-1. The detection limit was 5.0x10-6 mol L-1and recoveries between 98.0 and 106% were obtained. The sampling frequency was 60 determinations per hour and the RSD was smaller than 1.4% for 2.2x10-5 mol L-1 N-acetyl-L-cysteine.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

A flow injection turbidimetric procedure exploiting merging zones is proposed for determining homatropine methylbromide (HMB) in pharmaceutical preparations. The determination is based on the precipitation reaction of homatropine methylbromide with AgNO3 solution to form a precipitate, which was measured at 410 nm. The analytical curve was linear in the HMB concentration range from 8.0x10-4 to 1.7x10-3 mol L-1, with a detection limit of 9.5x10-5 mol L-1. The recoveries ranged from 94.9 to 104 %, the sampling frequency was 75 h-1 and relative standard deviations were smaller than 2.0 % for solutions containing 1.2x10-3 and 1.5x10-3 mol L-1 HMB (n=10). The results obtained for commercial formulations using the FIA procedure were in good agreement with those obtained by using a comparative method (r= 0.9983).

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The present work purposes the development of an analytical method for amitriptyline determination in pharmaceutical formulations using FIA system. It was based on interaction of amitriplyline with sodium lauryl sulphate in acid medium (pH 2.5) resulting in the ion-pair formation turbidimetrically detected at 410 nm. The fitting regression equation for range curve from 2.0 x 10-3 up to 3.2 x 10-3 mol L-1 was found to be analytical signal = -2.7417 + 0.1538 [amitriptyline] (r = 0.99991) with a detection limit of 1.8 x 10-3 mol L-1. The precision assessed as relative standard deviation (n = 10) was found to be 2.40 and 1.94%, for the respective concentration of amitriplyline 2.0 x 10-3 and 3.2 x 10-3 mol L-1 and the sample throughout was 60 h-1. The accuracy of method was successfully assessed in pharmaceutical formulation after comparison with a reference analytical method.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

This paper describes a homemade autosampler for flow injection analysis (FIA), constructed with two step motors from old floppy disk drives (5¼-inch). The autosampler was connected to a computer through the parallel port and the sampling process was controlled by software in Quick Basic. The performance of the system was assessed by the determination of ammonium, based on the gaseous diffusion into a bromocresol purple solution, following the spectrophotometric determination of change in absorbance. The easy and simple construction is the main characteristics of this equipment and analytical results with RSD lower than 1% were obtained.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

A flow injection chemiluminescence method for the determination of paracetamol in pharmaceutical formulations is described. It is based on the consumption of the sodium hypochlorite by paracetamol and decreases of the analytical signal. The analytical curve was linear in the paracetamol concentration range from 5.0 x 10-6 to 5.0 x 10-5 mol L-1, with a detection limit of 1.8 x 10-6 mol L-1. The RSDs were 2.0 and 1.2% respectively for 2.0 x 10-5 and 4.0 x 10-5 mol L-1 paracetamol solutions (n = 10) and a sampling frequency of 180 h-1 was obtained.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

A simple, accurate and precise flow-injection turbidimetric procedure for the determination of fluoxetine hydrochloride in pharmaceutical formulations is reported. The procedure is based on the precipitation of chloride of fluoxetine hydrochloride with silver nitrate solution and the yielded insoluble AgCl(s) was monitored at 420 nm. The analytical curve was linear in the fluoxetine hydrochloride concentration range 3.0 x 10-5 - 5.0 x 10-4 mol L-1 with a detection limit of 10 µmol L-1 and, a sample throughout of 60 h-1.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The present work purposes the preparation of a silica gel sorbent organically modified with 2-aminoethyl-3-aminobutylmethyldimethoxysilane (AAMDMS) and imprinted with Cu2+ ions by means surface imprinting technique and its use for selective on-line sorbent preconcentration of Cu2+ ions with further UV-VIS spectrophotometric determination by flow injection analysis. The Cu2+-imprinted silica gel, when compared with non imprinted silica gel and silica gel, showed from the binary mixture of Cu2+/Ni2+ relative selectivity coefficient (k') of 6.84 and 5.43 and 6.64 and 19.83 for the mixture Cu2+/Pb2+, thus demonstrating higher selectivity of Cu2+-imprinted silica gel towards Cu2+ ions. Under optimized condition, the on-line preconcentration method provided detection limit of 3.4 μg L-1 and linear range ranging from 30.0 up to 300.0 μg L-1 (r = 0.995). The accuracy of method was successfully assessed by analyzing different kind of spiked water samples with recovery values ranging from 92.2 up to 103.0%.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

A flow injection on-line pre-concentration system coupled to thermospray flame furnace atomic absorption spectrometry (TS-FF-AAS) for cadmium determination at sub μg L-1 levels in seawater samples was developed. The on-line system was evaluated by analysing cadmium containing in a synthetic seawater matrix (2.5% m/v NaCl, 0.5% m/v MgCl2 and 0.8% m/v CaCl2). A sample volume of 2 mL allows determining Cd with a detection limits of 30 ng L-1 (3* σblank/slope), pre-concentration factor of 34 and repeatability of 1,8% (calculated as RSD, N=8 and containing 200 ng L-1 of Cd ).

Relevância:

90.00% 90.00%

Publicador:

Resumo:

A simple flow-injection amperometric procedure using a three-electrode-integrated sensor for the determination of H2O2 in antiseptic mouthwash is reported. This method involves the use of a working composite electrode modified with Prussian Blue (PB) particles that was easily adapted as detector in FIA. The best amperometric response was observed for a composite containing 30% of graphite modified with PB particles (GAP) and 70% of pure graphite (GR). The proposed method presents a linear response in the range of 10 to 200 μmol L-1. The detection and quantification limits were 0.8 and 2.6 μmol L-1, respectively.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

A flow injection spectrophotometric procedure for the determination of glyphosate in commercial formulations of herbicides is proposed. The determination is based on the reaction of glyphosate and p-dimethylaminocinnamaldehyde, in acid medium, yielding a colored compound (l máx = 495 nm). Under optimal conditions, Beer's law is obeyed in a concentration range 40-640 mg mL-1 with a correlation coefficient of 0.9996. The detection limit was 8.60 mg mL-1 for glyphosate. The method was successfully applied for the determination of glyphosate in commercial formulations of herbicides. Recovery of glyphosate from various commercial samples of herbicides range from 91.0 to 110%.