966 resultados para Analytical results
Resumo:
The characteristics, performance, and application of an electrode, namely, Pt vertical bar Hg vertical bar Hg-2(IBP)(2)vertical bar Graphite, where IBP stands for ibuprofenate ion, are described. This electrode responds to IBP with sensitivity of (58.6 +/- 0.9) mV decade 1 over the range 5.0 x 10(-5)-1.0 x 10(-1) mol L-1 at pH 6.0-9.0 and a detection limit of 3.8 x 10(-5) mol L-1. The electrode is easily constructed at a relatively low cost with fast response time (within 1530 s) and can be used for a period of 5 months without any considerable divergence in potentials. The proposed sensor displayed good selectivity for ibuprofen in the presence of several substances, especially concerning carboxylate and inorganic anions. It was used for the direct assay of ibuprofen in commercial tablets by means of the standard additions method. The analytical results obtained by using this electrode are in good agreement with those given by the United States Pharmacopeia procedure. (c) 2006 Elsevier B.V. All rights reserved.
Resumo:
A spectrophotometric method for the determination of dipyrone in pharmaceutical preparations is proposed. This method is based on selective oxidation of dipyrone, in the presence of sulphuric acid, splitting off formaldehyde which reacts with chromotropic acid, also in a sulphuric acid medium, producing a violet-red compound (lambda(max) 575 nm). Beer's law is obeyed in a concentration range of 0.57-5.7 ppm dipyrone with an excellent correlation coefficient (r = 0.9997). The results show a simple, accurate, selective and readily applied method to the determination of dipyrone in pharmaceutical products. The analytical results obtained for these products by the proposed method are in agreement with those of the Brazilian Pharmacopoeia procedure. No interference was observed from common excipients in formulations. Recoveries were within 98.7-101.2%, with standard deviations ranging from 0.2 to 1.7%. (C) 1999 Elsevier B.V. S.A. All rights reserved.
Resumo:
Exact and closed-form expressions for the level crossing rate and average fade duration are presented for the M branch pure selection combining (PSC), equal gain combining (EGC), and maximal ratio combining (MRC) techniques, assuming independent branches in a Nakagami environment. The analytical results are thoroughly validated by reducing the general case to some special cases, for which the solutions are known, and by means of simulation for the more general case. The model developed here is general and can be easily applied to other fading statistics (e.g., Rice).
Resumo:
A robust 12 kW rectifier with low THD in the line currents, based on an 18-pulse transformer arrangement with reduced kVA capacities followed by a high-frequency isolation stage is presented in this work. Three full-bridge (buck-based) converters are used to allow galvanic isolation and to balance the dc-link currents, without current sensing or current controller. The topology provides a regulated dc output with a very simple and well-known control strategy and natural three-phase power factor correction. The phase-shift PWM technique, with zero-voltage switching is used for the high-frequency dc-dc stage. Analytical results from Fourier analysis of winding currents and the vector diagram of winding voltages are presented. Experimental results from a 12 kW prototype are shown in the paper to verify the efficiency, robustness and simplicity of the command circuitry to the proposed concept.
Resumo:
The characteristics, performance, and application of an electrode, namely Pt| Hg|Hg-2(DCF)(2)|graphite, where DCF stands for diclofenac ion, are described. This electrode responds to diclofenac with sensitivity of (58.1 +/- 0.8) mV/decade over the range 5.0 x 10(-5) to 1.0 x 10(-2) Mol l(-1) at pH 6.5-9.0 and a detection limit of 3.2 x 10(-5) mol l(-1). The electrode is easily constructed at a relatively low cost with fast response time (within 10-30 s) and can be used for a period of 5 months without any considerable divergence in potentials. The proposed sensor displayed good selectivity for diclofenac in the presence of several substances, especially concerning carboxylate and inorganic anions. It was used to determine diclofenac in pharmaceutical preparations by means of the standard additions method. The analytical results obtained by using this electrode are in good agreement with those given by the United States Pharmacopeia procedures. (c) 2005 Elsevier B.V. All rights reserved.
Resumo:
This work describes an analytical procedure for vanadium determination in human hair slurries by electrothermal AAS using longitudinal heating (LHGA) and transversal heating (THGA) graphite furnace atomizers. The samples were powdered using cryogenic grinding and the hair slurries containing 0.2% (m/v) were prepared in three different media for determination of vanadium: 0.14 mol L-1 HNO3, 0.1% (v/v) Triton X-100 and 0.1% (v/v) water soluble tertiary amines (CFA-C, pH 8). The limits of detection (LOD), limits of quantification (LOQ), and characteristic masses obtained were 0.28, 0.95 mu g L-1 and 35 pg (LHGA) and 0.34, 1.13 mu g L-1 and 78 pg (THGA), respectively. The accuracy of the analytical results obtained by the proposed procedure in both equipments was confirmed by a paired t-test at the 95% confidence level and compared with a conventional procedure based on acid digestion. (c) 2006 Elsevier B.V. All rights reserved.
Resumo:
Initially this paper shows the ground wire reduction process for generic multiphase transmission lines and after, the ground wire reduction process for a specilic 440-kV three-phase overhead transmission line. Following this, the influence of the ground wire reduction process considering two situations is shown: first, considering frequency independence and second, when these parameters are considered as frequency dependent. This paper presents analytical results for generic multiphase transmission lines. For a specific 440-kV three-phase overhead transmission line, analytical and graphic results are shown considering real data for every frequency between 10 Hz and 1 MHz.
Resumo:
The efficiency of two methods for determining 3-hydroxybutyrate and 3-hydroxyvalerate content in the biopolymer (poly(3-hydroxybutyrate-co-3-hydroxyvalerate) has been evaluated. Both methods are based on (a) the hydrolysis of polymers, (b) the esterification with methyl (method A) and isoamilic alcohol (method B) and (c) analysis of the esters by gas chromatography using flame ionization detection (GC-FID). After optimization of the analytical conditions, the main validation parameters (linearity, quantification limit, detection limit, recovery, sensitivity and precision) were determined showing that both analytical procedures can be applied to control the process of poly(3-hydroxybutyrate) production. However, method B gives better analytical results than method A and has the advantage of not using chlorinated solvents.
Resumo:
The feasibility of using internal standardization (IS) to correct for interferences in hydride generation with in situ trapping in graphite furnace was evaluated. Arsenic was chosen as internal standard for Sb determination and Ir was used as permanent modifier. Fluctuations in the main parameters that affect the analytical results were minimized by IS and an effective contribution was verified in the studies of liquid phase interferences. Cobalt and Ni2+ were selected to illustrate the potential use of IS on the correction of interference by transition metals. The application of IS allows the Sb determination in samples containing up to 20-fold higher concentration of the Co2+ and Ni2+ when compared to the procedure without IS. The relative standard deviation of measurements varied from 0.3% to 0.7% and from 1.1% to 3.2% with and without IS, respectively. Recoveries within 92% and 107% of spiked aqueous solution containing Sb(III) and Sb(V) were found. (c) 2005 Elsevier B.V. All rights reserved.
Resumo:
The study aimed to relate the photosynthetic pigments, which were extracted in a laboratory and the readings were obtained by the portable chlorophyll meter ClorofiLOG 1030, by using mathematical models in sesame leaves. This work was conducted in December 2010, at Empresa Brasileira de Pesquisa Agropecuária (EMBRAPA) Cotton, where feaf discs were removed to measure chlorophyll indexes through the portable chlorophyll meter. The same leaf discs were subjected to extraction of photosynthetic pigments, by using 5 mL dimethyl sulfoxide (DMSO), and were kept in a water bath at 70 degrees C for 30 min. Afterwards, an aliquot of 3 mL was removed to be read in a spectrophotometer at wavelengths of 470, 646 and 663 nm. Based on analytical results, mathematical models were adjusted by using the chlorophyll index to predict the levels of chlorophyll a, b, and total, and of carotenoids and their relationships. The study concluded that the portable chlorophyll meter ClorofiLOG 1030 can be used to estimate the concentration of photosynthetic pigments in sesame leaves with high precision, besides saving resources and time.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
This work presents a new high power factor three-phase rectifier based on a Y-connected differential autotransformer with reduced kVA and 18-pulse input current followed by three DC-DC boost converters. The topology provides a regulated output voltage and natural three-phase input power factor correction. The lowest input current harmonic components are the 17th and the 19th. Three boost converters, with constant input currents and regulated parallel connected output voltages are used to process 4kW each one. Analytical results from Fourier analyses of winding currents and the vector diagram of winding voltages are presented. Simulation results to verify the proposed concept and experimental results are shown in the paper.
Resumo:
A calibration method was developed using flow injection analysis (FI) with a Gradient Calibration Method (GCM). The method allows the rapid determination of zinc In foods (approximately 30 min) after treatment with concentrated sulphuric acid and 30% hydrogen peroxide, and analysis with flame atomic absorption spectrometry (FAAS). The method provides analytical results with a relative standard deviation of about 2% and requires less time than by conventional FI calibration. The electronic selection of different segments along the gradient and monitoring of the technique covers wide concentration ranges while maintaining the inherent high precision of flow injection analysis. Concentrations, flow rates, and flow times of the reagents were optimized in order to obtain best accuracy and precision. Flow rates of 10 mL/min were selected for zinc. In addition, the system enables electronic dilution and calibration where a multipoint curve can be constructed using a single sample injection.
Resumo:
A new, simple, precise, rapid and low-cost spectrophotometric method for methyldopa determination in pharmaceutical preparations is described. This method is based on the complexation reaction of methyldopa with molybdate. Absorbance of the resulting yellow coloured product is measured at 410 nm. Beer's Law is obeyed in a concentration range of 50 - 200 μg ml -1 methyldopa with an excellent correlation coefficient (r = 0.9999). No interference was observed from common excipients in formulations. The results show a simple, accurate, fast and readily applied method to the determination of methyldopa in pharmaceutical products. The analytical results obtained for these products by the proposed method are in agreement with those of the Brazilian Pharmacopoeia procedure at 95% confidence level.
Resumo:
The characteristics, performance, and application of an electrode, namely, Pt|Hg|Hg 2(NAP) 2| Graphite, where NAP stands for naproxenate ion, are described. This electrode responds to NAP with sensivity of (58.1± 0.9) mV decade -1 over the range 5.0 × 10 -5 - 1.0 × 10 -2 mol L -1 at pH 6.0-9.0 and a detection limit of 3.9 × 10 -5 mol L -1. The electrode is easily constructed at a relatively low cost with fast response time (within 10-35 s) and can be used for a period of 6 months without any considerable divergence in potentials. The proposed sensor displayed good selectivity for naproxen in the presence of several substances, especially concerning carboxylate and inorganic anions. It was used for the direct assay of naproxen in commercial tablets by means of the standard additions method. The analytical results obtained by using this electrode are in good agreement with those given by the United States Pharmacopeia procedure. ©2006 Sociedade Brasileira de Química.