988 resultados para Age estimation


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The Japan Sea experienced bottom water anoxia at the last glacial maximum (LGM) since it is surrounded by four shallow straits, the sill depths of which are close to, or shallower than, the drop in sea level (~120 m) that occurred then. A distinctive negative d18O excursion of planktonic foraminifera also took place during the LGM. This excursion has been interpreted from foraminiferal data as recording a drop in the paleosalinity of surface waters on the assumption of a constant low sea surface temperatures between 34 and 11 ka. We present here a profile of alkenone-based sea surface temperatures (alkenone-SSTs) over the past 36 kyr. Our results suggest that SSTs during the LGM were much higher than those previously assumed. After considering the factors that might affect estimation of alkenone-SSTs and comparisons of core-top alkenone-SSTs values with values for modern seawater we conclude that the higher alkenone-SSTs during the LGM are reliable and reasonable. These warm SSTs were probably caused by radiative equilibrium associated with the development of stable water stratification in the Japan Sea during the LGM.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this research was to implement a methodology through the generation of a supervised classifier based on the Mahalanobis distance to characterize the grapevine canopy and assess leaf area and yield using RGB images. The method automatically processes sets of images, and calculates the areas (number of pixels) corresponding to seven different classes (Grapes, Wood, Background, and four classes of Leaf, of increasing leaf age). Each one is initialized by the user, who selects a set of representative pixels for every class in order to induce the clustering around them. The proposed methodology was evaluated with 70 grapevine (V. vinifera L. cv. Tempranillo) images, acquired in a commercial vineyard located in La Rioja (Spain), after several defoliation and de-fruiting events on 10 vines, with a conventional RGB camera and no artificial illumination. The segmentation results showed a performance of 92% for leaves and 98% for clusters, and allowed to assess the grapevine’s leaf area and yield with R2 values of 0.81 (p < 0.001) and 0.73 (p = 0.002), respectively. This methodology, which operates with a simple image acquisition setup and guarantees the right number and kind of pixel classes, has shown to be suitable and robust enough to provide valuable information for vineyard management.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The objective of this paper is to estimate technical efficiency in retailing; and the influence of inventory investment, wage levels, and firm age on this efficiency. We use the output supermarket chains’ sales volume, calculated isolating the retailer price effect on its sales revenue. This output allows us to estimate a strictly technical concept of efficiency. The methodology is based on the estimation of a stochastic parametric function. The empirical analyses applied to panel data on a sample of 42 supermarket chains between 2000 and 2002 show that inventory investment and wage level have an impact on technical efficiency. In comparison, the effect of these factors on efficiency calculated through a monetary output (sales revenue) shows some differences that could be due to aspects related to product prices.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: The aim of this study was to analyze theoretically the errors in the central corneal power calculation in eyes with keratoconus when a keratometric index (nk) is used and to clinically confirm the errors induced by this approach. Methods: Differences (DPc) between central corneal power estimation with the classical nk (Pk) and with the Gaussian equation (PGauss c ) in eyes with keratoconus were simulated and evaluated theoretically, considering the potential range of variation of the central radius of curvature of the anterior (r1c) and posterior (r2c) corneal surfaces. Further, these differences were also studied in a clinical sample including 44 keratoconic eyes (27 patients, age range: 14–73 years). The clinical agreement between Pk and PGauss c (true net power) obtained with a Scheimpflug photography–based topographer was evaluated in such eyes. Results: For nk = 1.3375, an overestimation was observed in most cases in the theoretical simulations, with DPc ranging from an underestimation of 20.1 diopters (D) (r1c = 7.9 mm and r2c = 8.2 mm) to an overestimation of 4.3 D (r1c = 4.7 mm and r2c = 3.1 mm). Clinically, Pk always overestimated the PGauss c given by the topography system in a range between 0.5 and 2.5 D (P , 0.01). The mean clinical DPc was 1.48 D, with limits of agreement of 0.71 and 2.25 D. A very strong statistically significant correlation was found between DPc and r2c (r = 20.93, P , 0.01). Conclusions: The use of a single value for nk for the calculation of corneal power is imprecise in keratoconus and can lead to significant clinical errors.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

AIM: To evaluate the prediction error in intraocular lens (IOL) power calculation for a rotationally asymmetric refractive multifocal IOL and the impact on this error of the optimization of the keratometric estimation of the corneal power and the prediction of the effective lens position (ELP). METHODS: Retrospective study including a total of 25 eyes of 13 patients (age, 50 to 83y) with previous cataract surgery with implantation of the Lentis Mplus LS-312 IOL (Oculentis GmbH, Germany). In all cases, an adjusted IOL power (PIOLadj) was calculated based on Gaussian optics using a variable keratometric index value (nkadj) for the estimation of the corneal power (Pkadj) and on a new value for ELP (ELPadj) obtained by multiple regression analysis. This PIOLadj was compared with the IOL power implanted (PIOLReal) and the value proposed by three conventional formulas (Haigis, Hoffer Q and Holladay). RESULTS: PIOLReal was not significantly different than PIOLadj and Holladay IOL power (P>0.05). In the Bland and Altman analysis, PIOLadj showed lower mean difference (-0.07 D) and limits of agreement (of 1.47 and -1.61 D) when compared to PIOLReal than the IOL power value obtained with the Holladay formula. Furthermore, ELPadj was significantly lower than ELP calculated with other conventional formulas (P<0.01) and was found to be dependent on axial length, anterior chamber depth and Pkadj. CONCLUSION: Refractive outcomes after cataract surgery with implantation of the multifocal IOL Lentis Mplus LS-312 can be optimized by minimizing the keratometric error and by estimating ELP using a mathematical expression dependent on anatomical factors.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: To evaluate the predictability of the refractive correction achieved with a positional accommodating intraocular lenses (IOL) and to develop a potential optimization of it by minimizing the error associated with the keratometric estimation of the corneal power and by developing a predictive formula for the effective lens position (ELP). Materials and Methods: Clinical data from 25 eyes of 14 patients (age range, 52–77 years) and undergoing cataract surgery with implantation of the accommodating IOL Crystalens HD (Bausch and Lomb) were retrospectively reviewed. In all cases, the calculation of an adjusted IOL power (PIOLadj) based on Gaussian optics considering the residual refractive error was done using a variable keratometric index value (nkadj) for corneal power estimation with and without using an estimation algorithm for ELP obtained by multiple regression analysis (ELPadj). PIOLadj was compared to the real IOL power implanted (PIOLReal, calculated with the SRK-T formula) and also to the values estimated by the Haigis, HofferQ, and Holladay I formulas. Results: No statistically significant differences were found between PIOLReal and PIOLadj when ELPadj was used (P = 0.10), with a range of agreement between calculations of 1.23 D. In contrast, PIOLReal was significantly higher when compared to PIOLadj without using ELPadj and also compared to the values estimated by the other formulas. Conclusions: Predictable refractive outcomes can be obtained with the accommodating IOL Crystalens HD using a variable keratometric index for corneal power estimation and by estimating ELP with an algorithm dependent on anatomical factors and age.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

There are very few studies in Spain that treat underachievement rigorously, and those that do are typically related to gifted students. The present study examined the proportion of underachieving students using the Rasch measurement model. A sample of 643 first-year high school students (mean age = 12.09; SD = 0.47) from 8 schools in the province of Alicante (Spain) completed the Battery of Differential and General Skills (Badyg), and these students' General Points Average (GPAs) were recovered by teachers. Dichotomous and Partial credit Rasch models were performed. After adjusting the measurement instruments, the individual underachievement index provided a total sample of 181 underachieving students, or 28.14% of the total sample across the ability levels. This study confirms that the Rasch measurement model can accurately estimate the construct validity of both the intelligence test and the academic grades for the calculation of underachieving students. Furthermore, the present study constitutes a pioneer framework for the estimation of the prevalence of underachievement in Spain.