930 resultados para sequential injection analysis
Resumo:
INTRODUCTION: A significant proportion of prematurely born children encounter behavioral difficulties, such as attention deficit or hyperactivity, which could be due to executive function disorders. AIMS: To examine whether the standard neurodevelopmental assessment offered to premature children in Switzerland recognizes executive function disorders. METHODS: The study population consisted of 49 children born before 29 weeks of gestation who were examined between 5 and 6 years of age with a standard assessment, with additional items to assess executive functioning. Children with severe neurodevelopmental impairment were excluded (mental retardation, cerebral palsy, autism). Standard assessment consisted in the Kaufman Assessment Battery for Children (K-ABC), which comprises three subscales: sequential processes (analysis of sequential information), simultaneous processes (global analysis of visual information), and composite mental processes (CMP) (result of the other two scales), as well as a behavioral evaluation using the standardized Strengths and Difficulties Questionnaire (SDQ). Executive functioning was assessed with tasks evaluating visual attention, divided attention, and digit memory as well as with a specialized questionnaire, the Behavior Rating Index of Executive Functions (BRIEF), which evaluates several aspects of executive function (regulation, attention, flexibility, working memory, etc). RESULTS: Children were divided according to their results on the three K-ABC scales (< or>85), and the different neuropsychological tasks assessing executive function were compared between the groups. The CMP did not differentiate children with executive difficulties, whereas a score<85 on the sequential processes was significantly associated with worse visual and divided attention. There was a strong correlation between the SDQ and the BRIEF questionnaires. For both questionnaires, children receiving psychotherapy had significantly higher results. Children who presented behavioral problems assessed with the SDQ presented significantly higher scores on the BRIEF. CONCLUSION: A detailed analysis of the standard neurodevelopmental assessment allows the identification of executive function disorders in premature children. Children who performed below 85 on the sequential processes of the K-ABC had significantly more attentional difficulties on the neuropsychological tasks and therefore have to be recognized and carefully followed. Emotional regulation had a strong correlation with behavioral difficulties, which were suitably assessed with the SDQ, recognized by the families, and treated.
Resumo:
This review presents the latest advances of the mechanisation in sample preparation using microwave oven. The fundamental principles of microwaves field interaction with matter are presented, followed by the basic principles of microwave equipment construction. Hyphenation of microwave oven with flow injection analysis or robotic are discussed as well as some metodological difficulties and solutions by its implementation.
Resumo:
An automatic system for the direct determination of lead and tin by atomic absorption spectrometry is described. The on-line treatment of the metallic samples was obtained by anodic electrodissolution in a flow injection system. Lead was determined by flame atomic absorption spectrometry (FAAS) and tin by graphite furnace atomic absorption spectrometry (GFAAS). A computer program managed the current source and the solenoid valves that direct the fluids. Good linear correlations between absorbance and current intensity for lead and tin were observed. Results were in agreement with the certified values. Precision was always better than 5%. The recommended procedure allows the direct determination of 60 or 30 elements/h using FAAS or GFAAS, respectively.
Resumo:
Didactic experiments are proposed in order to demonstrate the characteristics of flow injection analysis and to extend the applications of FIA to the determination of physical chemistry parameters in undergraduate labs. All experiments can be performed with the same flow manifold by employing usual FIA devices. Analytical characteristics are presented by means of the determination of iron in river water, employing 1,10-phenantroline as chromogenic reagent. Physical chemistry applications were the determination of reaction stoichiometries by continuous variation and mole-ratio methods and the evaluation of the pH and ionic strength effects on the kinetic of the reduction of hexacianoferrate(III) by ascorbic acid.
Resumo:
A flow injection spectrophotometric system was projected for monitoring hydrogen peroxide during photodegradation of organic contaminants in photo-Fenton processes (Fe2+/H2O2/UV). Sample is injected manually in a carrier stream and then receives by confluence a 0.1 mol L-1 NH4VO3 solution in 0.5 mol L-1 H2SO4 medium. The product formed shows absorption at 446 nm which is recorded as a peak with height proportional to H2O2 concentration. The performance of the proposed system was evaluated by monitoring the consumption of H2O2 during the photodegradation of dichloroacetic acid solution by foto-Fenton reaction.
Resumo:
A spectrophotometric flow injection analysis (FIA) procedure employing natural urease enzyme source for the determination of urea in animal blood plasma was developed. Among leguminous plants used in the Brazilian agriculture, the Cajanus cajan specie was selected as urease source considering its efficiency and availability. A minicolumn was filled with leguminous fragments and coupled to the FIA manifold, where urea was on-line converted to ammonium ions and subsequently it was quantified by spectrophotometry. The system was employed to determine urea in animal plasma samples without any prior treatment. Accuracy was assessed by comparison results with those obtained employing the official procedure and no significant difference at 90 % confidence level was observed. Other profitable features such as an analytical throughput of 30 determinations per hour, a reagent consumption of 19.2 mg sodium salicylate, 0.5 mg sodium hipochloride and a relative standard deviation of 1.4 % (n= 12) were also obtained.
Resumo:
An important component for the automation of flow injection analysis (FIA) systems is the sample injection valve. A simple and inexpensive commutator with 16 pinch valves (8 normally open and 8 closed) was developed and configured as a multichannel injection valve. It is activated by a single solenoid of 3 Kgf, powered by a pulsed driver circuit, controlled by a microcomputer or a switch. FIA with spectrophometric detection of potassium dichromate solution was used for the evaluation of the new injection valve and its comparison with other valves, for sample loops of 50, 100, 200, 300 and 500 muL. The repeatability was favorable (RSD 1.0% for 15 injections at each loop volume) compared to a manual injector, an electropneumatic injector and an injector configured with three mini solenoid valves (RSD 1.1, 1.3 and 1.0%, respectively, for15 injections at each loop volume).
Resumo:
A review about the state-of-the-art of flow injection analysis (FIA) -- capillary electrophoresis (CE) systems is presented. The basic principles of flow injection and capillary electrophoresis are briefly revised. The main aspects of the FIA-CE hybridization, including advantages and shortcomings, are discussed. Some applications involving all different designs are also presented. This review covers the literature from 1997 up to 2000.
Resumo:
This technical note describes a new and simple electronic circuit for driving solenoid valves. The circuit is based on a single integrated circuit DRV103, which is able to drive resistive or inductive loads up to 1.5 A. Switching of 12-V loads can be controlled by TTLlevel signals in two distinct steps. Initially, 12 V is applied during 110 ms, followed by 4.2 V RMS until the end of the activation TTL pulse. This mode of operation is particularly suitable to drive solenoids, because it requires a higher voltage to start and a lower maintenance voltage. By using this circuit, power consumption and heating are reduced and the solenoid lifetime is enhanced. Moreover, this circuit is specially appropriated to build computercontrolled solenoid valves systems.
Resumo:
The present paper has as objective to apply a sequential Cluster Analysis to the atmospheric particles: Hierarchical Cluster Analysis followed by Nonhierarchical Cluster Analysis. The hierarchical cluster analysis results were used as start point for the nonhierarchical cluster analysis as an agglomerative technique. These particles were taken from two areas of the metropolitan region of Porto Alegre, Charqueadas and Sapucaia do Sul., from may /97 to may/98, using a High Volume Sampler (Hi-Vol). Around 10,000 particles were analysed by Scanning Electron Microscope with Energy-Dispersive X-Ray microanalysis (SEM-EDS). The Hierarchical Cluster Analysis allowed the identification of five groups of particles, whose amounts were differentiated according to the summer and the winter campaigns. The abundance of each type of particles inside each group according to the different sections was verified by the Nonhierarchical Cluster Analysis, resulting in information about the emissions sources. The groups of particles of Si/Al and Si and of Fe/Zn and Fe for Charqueadas were more significant in section 2 and 3 (NW and W wind directions) and in section 1 (SE wind direction), evidencing the influence of the coal power plant and steel industry, respectively located in these quadrants. In Sapucaia do Sul the data were more heterogeneous, causing a certain difficulty to identify the source as anthropogenic. Nevertheless the group of particles containing Fe was found in sectors of NW/W wind directions which shows the influence of the steel plant.
Resumo:
In this work, a spectrophotometric flow injection analysis system using a crude extract of avocado (Persea americana) as a source of polyphenol oxidase to dopamine determination was developed. The substrates and enzyme concentrations from 2.4x10-7 to 5.3x10-4 mol L-1 and 28 to 332 units mL-1 were evaluated, respectively. In addition, the FIA parameters such as sample loop (50 to 500 µL), flow rate (1.4 to 4.3 mL min-1) and reactor length (100 to 500 cm) were also evaluated in a 0.1 mol L-1 phosphate buffer solution (pH 7.0). Dopamine solution concentrations were determined using 277 units mL-1 enzyme solution, 400 mL enzyme loop, 375 µL sample loop, 2.2 mL min-1 flow rate and a reactor of 350 cm. The analytical curve showed a linearity from 5.3x10-5 to 5.3x10-4 mol L-1 dopamine with a detection limit of 1.3x10-5 mol L-1. The analytical frequency was 46 h-1 and the RSD lower than 0.5% for 5.3x10-4 mol L-1 dopamine solution (n=10). A paired t-test showed that all results obtained for dopamine in commercial formulations using the proposed flow injection procedure and a spectrophotometric procedure agree at the 95% confidence level.
Resumo:
In this work two procedures were proposed for analytical curves construction using a single standard solution employing a flow injection system with solid phase spectrophotometric detection (FI-SPS). A flow cell contends the chromogenic reagent 1-(2-tiazolylazo)-2-naphtol was positioned on the optical path. The first procedure was based on controlled concentration of analyte on solid phase and the relations between absorbance and the total volume of injected allowed the calculation of analyte concentration. The second procedure was developed employing controlled dispersion/retention in flow system where analyte concentration was obtained by exploiting the relation between transient signals of samples and single standard solution at equivalent reading time. The procedures were successfully applied for zinc determination in synthetic solutions with good precision and accuracy at 95% confidence level.
Resumo:
Automatic flow procedures based on the multicommutation concept, dedicated to the determination of 3-hydroxybutyrate, glucose and cholesterol are proposed. The enzymes were immobilized on glass beads and packed into mini-columns that were coupled to a flow system. Sampling throughputs of 55, 40 and 40 determinations per hour, linear response from 10 to 150, 50 to 600, 25 to 125 mg L-1, detection limits of 1.5, 14 and 4 mg L-1 and relative standard deviations of 1, 2 and 2% for 3-hydroxybutyrate, glucose and cholesterol, respectively, were achieved.
Resumo:
The sensitivity and accuracy of sequential injection methods are dependent on efficient overlapping of reagent and sample zones as they are propelled toward the detector cell. The formation of the reduced phosphomolybdic acid is used to demonstrate that the overlapping efficiency in a fixed reaction coil relies on a suitable choice of reagent to sample volume ratio. Additionally, under poor mixing conditions or highly concentrated samples, the reaction extension is strongly dependent on the reagent concentration. The zone-sampling concept is exploited to determine phosphate in cola-based soft drinks after in-line dilution in an auxiliary coil.
Resumo:
This paper describes a homemade autosampler for flow injection analysis (FIA), constructed with two step motors from old floppy disk drives (5¼-inch). The autosampler was connected to a computer through the parallel port and the sampling process was controlled by software in Quick Basic. The performance of the system was assessed by the determination of ammonium, based on the gaseous diffusion into a bromocresol purple solution, following the spectrophotometric determination of change in absorbance. The easy and simple construction is the main characteristics of this equipment and analytical results with RSD lower than 1% were obtained.