10 resultados para Absortometria de dupla energia

em Repositório da Produção Científica e Intelectual da Unicamp


Relevância:

90.00% 90.00%

Publicador:

Resumo:

Universidade Estadual de Campinas . Faculdade de Educação Física

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Universidade Estadual de Campinas . Faculdade de Educação Física

Relevância:

80.00% 80.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate the association between quantitative ultrasonography at hand phalanges (QUS) and dual energy X-ray absorptiometry (DXA), and between these methods with food intake and history of bone fractures. SUBJECTS AND METHODS:After two years of follow up of 270 schoolchildren, 10 of them, who showed bone mass below - 2 SD in QUS, were included in the present study. Laboratory results and DXA data were analyzed. RESULTS: Bone mass evaluated by DXA at L1-L4 ranged from -2.8 to -1.1 SDS, and whole body bone mass, from -2.9 to -1.2 SDS. Three children had history of non-pathological bone fractures. Dietary assessment showed low intake of calcium in 10 cases, of phosphorus in 6, and of vitamin D in 8 cases. There were no differences among the cases of bone mass below-2 SD in any of the three used methods. There was no association between history of bone fractures and food intake, and between these evaluations and bone mass. CONCLUSION: In this small group of schoolchildren there was an association between the methods QUS and DXA. However, there was no association between bone mass and the history of bone fractures, or calcium, phosphorus and vitamin D intake.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Universidade Estadual de Campinas . Faculdade de Educação Física

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dendrochemistry is based on the determination of elements retained in tree rings, which can be useful to characterize environmental occurrences. This work shows elemental mappings obtained by EDXRF of the cross section of a tree stem. The tree is originated from a polluted area in Campinas, São Paulo. Some profiles, as the sulfur one, show variations that can be attributed to external contributions, whereas the silicon one can be inferred to a protection defense natural mechanism. Besides being simultaneous and multielementar, the main advantages here are its performance through a non-destructive sample treatment and the ease of operation of XRF equipments.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work outlines the historic development of the concept and main theories of energy transfer, as well as the principal experiments carried out to confirm or refute the proposed theories. Energy transfer in coordination compounds is also discussed with a focus on rare earth systems.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To analyze if female Wistar rats at 56 weeks of age are a suitable model to study osteoporosis. MATERIALS AND METHODS: Female rats with 6 and 36 weeks of age (n = 8 per group) were kept over a 20-week period and fed a diet for mature rodents complete in terms of Ca, phosphorous, and vitamin D. Excised femurs were measured for bone mass using dual-energy x-ray absorptiometry, morphometry, and biomechanical properties. The following serum mar-kers of bone metabolism were analyzed: parathyroid hormone (PTH), osteocalcin (OC), osteoprotegerin (OPG), receptor activator of nuclear factor Κappa B ligand (RANKL), C-terminal peptides of type I collagen (CTX-I), total calcium, and alkaline phosphatase (ALP) activity. RESULTS: Rats at 56 weeks of age showed important bone metabolism differences when compared with the younger group, such as, highest diaphysis energy to failure, lowest levels of OC, CTX-I, and ALP, and elevated PTH, even with adequate dietary Ca. CONCLUSION: Rats at 26-week-old rats may be too young to study age-related bone loss, whereas the 56-week-old rats may be good models to represent the early stages of age-related changes in bone metabolism.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To study the effects of pupillary constriction on frequency doubling perimetry in a group of normal subjects. Methods: Eighteen healthy volunteers participated in the study. Only one eye per patient (right eye) underwent frequency doubling perimetry (Full Threshold C-20 strategy). For the second session, one drop of 2% pilocarpine was administered to the volunteers' right eye and the examination was repeated after 60 minutes. Results: Sixty minutes after administration of 2% pilocarpine, there was a significant reduction of the pupillary diameter from 4.22 ± 0.17 mm to 1.55 ± 0.51 mm (p<0.05). There was a significant reduction of the mean retinal sensibility after pupillary constriction. The threshold sensitivity of the central 5º worsened by 5.67 ± 2.49 dB; the area between 2.5º and 10º worsened by 4.49 ± 2.73 dB; and the area between 10º and 20º worsened by 5.10 ± 3.55 dB (p<0.01). A reduction of 4.06 ± 2.67 dB was observed in the mean deviation, as well as an increase of 0.64 ± 0.94 dB in the pattern standard deviation (p<0.01). No differences were observed regarding the number of fixation losses, false-positive and false-negatives responses, and duration of the examination. Conclusion: Changes in pupillary diameter may produce significant declines in threshold sensitivities of the 20º visual field tested by frequency doubling perimetry. These results suggest that is important to maintain a constant pupillary diameter in seriate examinations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate the learning effect, short-term fluctuation and long-term fluctuation in healthy subjects undergoing frequency doubling perimetry (FDP). METHODS: Twenty healthy young subjects underwent FDT (program N30, full threshold) in one eye (right). Each subject was tested once in the first three sessions and three times in the fourth session. Both short- and long-term fluctuations were studied as the average fluctuation of all the tested points or as a point-to-point fluctuation. To study the learning effect, the MDs values of the first session were compared to the second, third and fourth sessions. RESULTS: In the short-term analysis (3 examination done in the last session), the total mean sensitivity was 31.91 ± 1.20 dB and the mean MD and PSD were 0.84 ± 1.85 and 3.73 ± 1.55 dB, respectively. The average short-term fluctuation was 1.72 ± 0.38 dB. When the four examination, performed at different visits, were compared, the average mean sensitivity of all sessions and the average long-term fluctuation were 31.75 ± 1.11 and 2.16 ± 0.26 dB, respectively. The MD averages of the first, second, third and fourth tests were 0.11 ± 2.14 dB, 0.47 ± 1.64 dB, 1.16 ± 1.62 dB and 0.98 ± 1.92 dB respectively. The MD difference between the first and the third and between the first and the fourth examinations were statistically significant (p<0.05). CONCLUSION: The threshold sensitivity detected by FDP is influenced by both short- and long-term fluctuations. We observed a mild learning effect that shoud be taken into account whenever a patient undergoes this test for the first time.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Universidade Estadual de Campinas . Faculdade de Educação Física