58 resultados para multi-commodity flow
em Scielo Saúde Pública - SP
Resumo:
A multi-commuted flow system was developed to determine propylthiouracil (PTU) based on the reaction of its thiol form with iminoquinone radical generated by the oxidation of N,N-dimethyl-p-phenylenediamine in an alkaline medium. PTU can be found in tautomeric forms and the tautomeric equilibrium was displaced to enhance the thiol form. However, the reaction product is unstable and its residence time in the flow path was carefully investigated. The proposed procedure showed good precision (< 1.5%) and a limit of detection (3s) of 0.11 mg L-1. High recoveries were obtained in the validation test. The procedure was employed for propylthiouracil determination in medications.
LOW COST ANALYZER FOR THE DETERMINATION OF PHOSPHORUS BASED ON OPEN-SOURCE HARDWARE AND PULSED FLOWS
Resumo:
The need for automated analyzers for industrial and environmental samples has triggered the research for new and cost-effective strategies of automation and control of analytical systems. The widespread availability of open-source hardware together with novel analytical methods based on pulsed flows have opened the possibility of implementing standalone automated analytical systems at low cost. Among the areas that can benefit from this approach are the analysis of industrial products and effluents and environmental analysis. In this work, a multi-pumping flow system is proposed for the determination of phosphorus in effluents and polluted water samples. The system employs photometric detection based on the formation of molybdovanadophosphoric acid, and the fluidic circuit is built using three solenoid micropumps. The detection is implemented with a low cost LED-photodiode photometric detection system and the whole system is controlled by an open-source Arduino Uno microcontroller board. The optimization of the timing to ensure the color development and the pumping cycle is discussed for the proposed implementation. Experimental results to evaluate the system behavior are presented verifying a linear relationship between the relative absorbance and the phosphorus concentrations for levels as high as 50 mg L-1.
Resumo:
Microscopic visualization, especially in transparent micromodels, can provide valuable information to understand the transport phenomena at pore scale in different process occurring in porous materials (food, timber, soils, etc.). Micromodels studies focus mainly on the observation of multi-phase flow, which presents a greater proximity to reality. The aim of this study was to study the process of flexography and its application in the manufacture of polyester resin transparent micromodels and its application to carrots. Materials used to implement a flexo station for micromodels construction were thermoregulated water bath, exposure chamber to UV light, photosensitive substance (photopolymer), RTV silicone polyester resin, and glass plates. In this paper, data on size distribution of a particular kind of carrot we used, and a transparent micromodel with square cross-section as well as a Log-normal pore size distribution with pore radii ranging from 10 to 110 µm (average of 22 µm and micromodel size of 10 × 10 cm) were built. Finally, it stresses that it has successfully implemented the protocol processing 2D polyester resin transparent micromodels.
Resumo:
The multi-element determination of Al, Cr, Mn, Ni, Cu, Zn, Cd, Ba, Pb, SO4= and Cl- in riverine water samples was accomplished by inductively coupled plasma mass spectrometry (ICP-MS). The sample passed through a column containing the anionic resin AG1-X8 and the metals were determined directly. The retained anionic species were eluted and SO4= and Cl- were determined at m/z 48 and 35 correspondent to the ions SO+ and Cl+ formed at the plasma. Accuracy for metals was assessed by analysing the certified reference TM-26 (National Water Research Institute of Canada). Results for SO4= and Cl- were in agreement with those obtained by turbidimetry and spectrophotometry. LOD's of 0.1 µg l-1 for Cd, Ba and Pb; 0.2 µg l-1 for Al, Mn and Cu; 0.5 µg l-1 for Cr; 0.9 for Zn; 2.0 µg l-1for Ni , 60 µg l-1 for S and 200 µg l-1 Cl were attained.
Resumo:
The purpose of this study was to develop a rapid, simple and sensitive quantitation method for pseudoephedrine (PSE), paracetamol (PAR) and loratadine (LOR) in plasma and pharmaceuticals using liquid chromatography-tandem mass spectrometry with a monolithic column. Separation was achieved using a gradient composition of methanol-0.1% formic acid at a flow rate of 1.0 mL min-1. Mass spectral transitions were recorded in SRM mode. System validation was evaluated for precision, specificity and linearity. Limit of detection for pseudoephedrine, paracetamol, and loratadine were determined to be 3.14, 1.86 and 1.44 ng mL-1, respectively, allowing easy determination in plasma with % recovery of 93.12 to 101.56%.
Resumo:
Non-linear functional representation of the aerodynamic response provides a convenient mathematical model for motion-induced unsteady transonic aerodynamic loads response, that accounts for both complex non-linearities and time-history effects. A recent development, based on functional approximation theory, has established a novel functional form; namely, the multi-layer functional. For a large class of non-linear dynamic systems, such multi-layer functional representations can be realised via finite impulse response (FIR) neural networks. Identification of an appropriate FIR neural network model is facilitated by means of a supervised training process in which a limited sample of system input-output data sets is presented to the temporal neural network. The present work describes a procedure for the systematic identification of parameterised neural network models of motion-induced unsteady transonic aerodynamic loads response. The training process is based on a conventional genetic algorithm to optimise the network architecture, combined with a simplified random search algorithm to update weight and bias values. Application of the scheme to representative transonic aerodynamic loads response data for a bidimensional airfoil executing finite-amplitude motion in transonic flow is used to demonstrate the feasibility of the approach. The approach is shown to furnish a satisfactory generalisation property to different motion histories over a range of Mach numbers in the transonic regime.
Resumo:
Implementing multi-level governance has been a key priority in EU cohesion policy. This study assesses the perceived achievements and shortcomings in implementing European Social Fund by analyzing the deficits and weaknesses as well as the poor participation of local agents who are in direct contact with the beneficiaries in order to design and implement this fund, which is the main financial instrument of EU social policy.
Resumo:
OBJECTIVE To describe the migration flows of demand for public and private hospital care among the health regions of the state of Sao Paulo, Brazil. METHODS Study based on a database of hospitalizations in the public and private systems of the state of Sao Paulo, Southeastern Brazil, in 2006. We analyzed data from 17 health regions of the state, considering people hospitalized in their own health region and those who migrated outwards (emigration) or came from other regions (immigration). The index of migration effectiveness of patients from both systems was estimated. The coverage (hospitalization coefficient) was analyzed in relation to the number of inpatient beds per population and the indexes of migration effectiveness. RESULTS The index of migration effectiveness applied to the hospital care demand flow allowed characterizing health regions with flow balance, with high emigration of public and private patients, and with high attraction of public and private patients. CONCLUSIONS There are differences in hospital care access and opportunities among health regions in the state of Sao Paulo, Brazil.
Resumo:
The determination of the rabies neutralizing antibody (VNA) response after immunization against rabies is an acceptable index of the efficacy of a vaccine and a successful treatment. Several tests have been developed in attempt to improve the assessment of VNA, from mice inoculation to cell-culture fluorescence inhibition tests. All of them, however, present special difficulties in terms of reading or accuracy. The present study describes a neutralization test performed in cell-culture appraised by flow cytometry (FC). Serial dilutions of the serum samples were mixed in vitro with rabies virus before the addition of BHK-21 cells. After 24h-incubation, cells were released by trypsin treatment, fixed and permeabilized with a p-formaldehyde solution and stained with a rabies virus nucleocapsid protein-specific antibody conjugate. The percentage of virus infection inhibition caused by specific antibodies present in the serum were evaluated in a Beckton & Dickinson FACSCalibur® flow cytometer. A correlation curve between the IU/ml content and the percentage of infective inhibition was built with a reference serum and the VNA titers of serum samples were obtained by extrapolation. Titers obtained by FC and standard test showed an effective pairing results (p < 0.01), with a correlation coefficient (r) = 0.7. These results permit to envisage the FC as a suitable technique to evaluate VNA in sera from immunized animals and likely in human serum samples. Nevertheless, new studies comparing FC to gold-standard techniques are required for determining the FC values of Sensibility and Specificity .
Resumo:
Aim: The objective was to describe an outbreak of bloodstream infections by Burkholderia cepacia complex (Bcc) in bone marrow transplant and hematology outpatients.Methods: On February 15, 2008 a Bcc outbreak was suspected. 24 cases were identified. Demographic and clinical data were evaluated. Environment and healthcare workers' (HCW) hands were cultured. Species were determined and typed. Reinforcement of hand hygiene, central venous catheter (CVC) care, infusion therapy, and maintenance of laminar flow cabinet were undertaken. 16 different HCWs had cared for the CVCs. Multi-dose heparin and saline were prepared on counter common to both units.Findings: 14 patients had B. multivorans(one patient had also B. cenopacia), six non-multivorans Bcc and one did not belong to Bcc. Clone A B. multivorans occurred in 12 patients (from Hematology); in 10 their CVC had been used on February 11/12. Environmental and HCW cultures were negative. All patients were treated with meropenem, and ceftazidime lock-therapy. Eight patients (30%) were hospitalized. No deaths occurred. After control measures (multidose vial for single patient; CVC lock with ceftazidime; cleaning of laminar flow cabinet; hand hygiene improvement; use of cabinet to store prepared medication), no new cases occurred.Conclusions: This polyclonal outbreak may be explained by a common source containing multiple species of Bcc, maybe the laminar flow cabinet common to both units. There may have been contamination by B. multivorans (clone A) of multi-dose vials.
Resumo:
SUMMARYAIDS-related cryptococcal meningitis continues to cause a substantial burden of death in low and middle income countries. The diagnostic use for detection of cryptococcal capsular polysaccharide antigen (CrAg) in serum and cerebrospinal fluid by latex agglutination test (CrAg-latex) or enzyme-linked immunoassay (EIA) has been available for over decades. Better diagnostics in asymptomatic and symptomatic phases of cryptococcosis are key components to reduce mortality. Recently, the cryptococcal antigen lateral flow assay (CrAg LFA) was included in the armamentarium for diagnosis. Unlike the other tests, the CrAg LFA is a dipstick immunochromatographic assay, in a format similar to the home pregnancy test, and requires little or no lab infrastructure. This test meets all of the World Health Organization ASSURED criteria (Affordable, Sensitive, Specific, User friendly, Rapid/robust, Equipment-free, and Delivered). CrAg LFA in serum, plasma, whole blood, or cerebrospinal fluid is useful for the diagnosis of disease caused by Cryptococcusspecies. The CrAg LFA has better analytical sensitivity for C. gattii than CrAg-latex or EIA. Prevention of cryptococcal disease is new application of CrAg LFA via screening of blood for subclinical infection in asymptomatic HIV-infected persons with CD4 counts < 100 cells/mL who are not receiving effective antiretroviral therapy. CrAg screening of leftover plasma specimens after CD4 testing can identify persons with asymptomatic infection who urgently require pre-emptive fluconazole, who will otherwise progress to symptomatic infection and/or die.
Resumo:
We report a rapid method for the flow cytometric quantitation of phagocytosis in heparinized complete peripherial blood (HCPB), using commercially available phycoerythrin-conjugated latex particles of 1µm diameter. The method is faster and shows greater reproducibility than Bjerknes' (1984) standard technique using propidium iodide-stained Candida albicans, conventionally applied to the leukocytic layer of peripherial blood but here modified for HCPB. We also report a modification of Bjerknes' Intracellular Killing Test to allow its application to HCPB.
Resumo:
Mycobaterium leprae infection was investigated in armadillos from the State of Espírito Santo, Brazil. The ML Flow test was performed on 37 nine-banded armadillos and positive results were found in 11 (29.7%). The ML Flow test may be used to identify possible sources of Mycobaterium leprae among wild armadillos.
Resumo:
O ML Flow e o ELISA PGL-I são testes sorológicos que detectam anticorpos IgM contra o glicolipídio fenólico I específico do Mycobacterium leprae. Para avaliar o comportamento destes testes em áreas endêmica e não endêmica para hanseníase foram estudados 351 voluntários no Brasil e no Chile, incluindo pacientes com hanseníase, controles sadios, portadores de outras doenças infecciosas, não infecciosas e dermatoses que fazem diagnóstico diferencial com hanseníase. O ponto de corte do ELISA foi estabelecido pelo método da Curva ROC (> 0,157). Em área endêmica, o ML Flow apresentou resultados positivos em 70% dos pacientes com hanseníase; o ELISA foi positivo em 53,3%. Em área não endêmica, o ML Flow foi negativo em todos os voluntários testados; o ELISA foi positivo em 4 voluntários. O ML Flow é um ensaio mais rápido, facilmente aplicável e, portanto, mais adequado para ser utilizado na Atenção Básica; o ELISA necessita, alem de uma infra-estrutura de laboratório adequada, pessoal treinado e especializado em sua execução.