140 resultados para Assaying apparatus


Relevância:

10.00% 10.00%

Publicador:

Resumo:

We intend to divulge an easy experiment that permits the determination of molar masses of various compounds by cryoscopy. The major advantage of this is the use of the tert-butyl alcohol as a solvent, which requires simple apparatus and easy procedures. The melting point of this alcohol is around 25 ºC, which makes it easy to freeze and then melt the solutions. This solvent has a high cryoscopic constant and is miscible with both polar and non-polar compounds. The molar masses of acetone, water, chloroform, dichloro-methane, ethanol, hexane, carbon tetrachloride and toluene were determined. The results were good except for water. Even though there are reliable techniques of molar mass determination nowadays, this method is still frequently taught in undergraduate courses.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Seeds Citrus oils (C. sinensis, C. limon and C. reticulata) extraction with hexane in a soxhlet apparatus and through supercritical fluid (CO2) were done. Besides triglycerides, the oils obtained with hexane comprised volatile compounds such as terpenes and fatty alcohols, esters, and aldehydes. However, the oils obtained by extraction with supercritical fluid presented only triglycerides. These results indicate that the extraction using supercritical fluid presents better selectivity. The activity of the oils on the development of the ant symbiotic fungus, Leucoagaricus gongylophorus, showed week activity and the topic insecticide assay showed better activity for the tangerine seed oil.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A simple system to measure the magnetic susceptibility of different materials is presented. The system uses an analytical scale with sensitivity on the order of micrograms and a permanent NdBFe magnet, based in the Rankine method. In this apparatus, the sample is placed near to the magnet that is fixed on the scale. Depending on the magnetic properties of the sample, an attractive or repulsive force will appear between the magnet and the magnetizing sample. Measuring this force, registered by the scale as a mass, the magnetic parameters such as: permeability and susceptibility of the sample can be determined. Despite it is simplicity the method is quantitative, precise and easily reproducible in many laboratories, what makes it attractive for teaching experiments.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A laboratory procedure was devised to recover bromine from waste alkaline aqueous solutions used in the isotopic determination of N-15. The laboratory apparatus comprises two round bottom flasks (1 and 2 L), a dropping funnel, a gas bubbler, a gas regulator and glass fittings. The waste solution is acidified with sulfuric acid forming molecular bromine that is stripped out by a flow of nitrogen gas bubbled through the solution. This gas is then bubbled through a solution of lithium hydroxide generating lithium bromide and lithium hypobromite. The efficiency of bromine recovery was estimated to be 82±2%. This resulting solution was successfully reused in the isotopic determination of N-15. The procedure can recycle most of the bromine used in the laboratory saving resources and preserving the environment. The procedure can be adapted to recover bromine of other laboratory waste streams.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The volatile constituents obtained from a static cryogenic headspace of Caesalpinia echinata Lam. (Leguminosae) showed E-beta-ocimene as the major compound (57.2%), beside other monoterpenes, C6 derivatives like n-hexanal and (E)-2-hexenal and nitrogen compounds such as indole and methyl anthranilate. From the essential oil of the leaves obtained by hydrodistillation in a Clevenger apparatus, (E)-3-hexen-1-ol was identified as the major constituent while phenolic compounds were the most representative class of secondary metabolites.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The discussion based on surfactant cleaning action is commonly used in chemistry classrooms for the comprehension of theoretical concepts related to surface tension and micelle formation. The experimental quantification of surface tension of aqueous solutions of surfactants provides the practical instruments for this discussion. The present paper describes a simplification on the common apparatus employed for the drop-weight method, making the determination of surface tension accessible to any chemistry lab. The surface tension of various liquids and the critical micelle concentration, CMC, of three commercial surfactants were measured with this modified method, and proved to be consistent with literature values.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A new configuration for coupling a gas diffusion cell to a sequential injection system is presented. The matrix exchange is made without the need for additional rotary injection valves or peristaltic pumps, keeping the original mechanical components of the sequential injection apparatus: one syringe pump (or peristaltic pump) and one selection valve. The system was tested constructing analytical curves for sulfide exploring the formation of the methylene blue dye. The proposed method has a detection limit of 60 µg L-1 S2-, with a linear dynamic range between 0.10 and 4.0 mg L-1 S2- concentrations, with a sampling frequency of 20 h-1.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work proposes a simple, fast and inexpensive method to determine As in natural waters, using X-ray fluorescence. 50 µL of each sample containing 100 mg L-1 of yttrium as internal standard were deposited over a 2.5 µm thickness MylarTM film. The samples were dried at 50 °C for 2 h. X-ray spectra were obtained using an EDXRF apparatus. The accuracy was determined by analyte addition/recovery and by comparison with Hydride Generation Atomic Absorption Spectrometry (HG AAS). A recovery of about 100% was obtained and the results were in good agreement with HG AAS. The method showed a relative standard deviation of 6.8% and a detection limit of 10.5 µg L-1 of As.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A threshold photoelectron spectrometer applied to the study of atomic and molecular threshold photoionization processes is described. The spectrometer has been used in conjunction with a toroidal grating monochromator at the National Synchrotron Radiation Laboratory (LNLS), Brazil. It can be tuned to accept threshold electrons (< 20 meV) and work with a power resolution of 716 (~18 meV at 12 eV) with a high signal/noise ratio. The performance of this apparatus and some characteristics of the TGM (Toroidal Grating Monochromator) beam line of LNLS are described and discussed by means of argon, O2 and N2 threshold photoelectron spectra.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A method is proposed for the determination of the moisture content of aromatic plants. This method is based on the co-distillation of the starting material in a modified Clevenger apparatus with four organic solvents (toluene, cyclohexane, dichloromethane and carbon tetrachloride). The results were compared with those obtained by oven drying at 105 ºC and steam distillation of the essential oil. The efficiencies of the methods were shown to be equivalent. The solvent distillation method was more practical, especially with respect to operating time (2 h).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The modern stopped-flow reaction analyzer has shown high efficiency and flexibility, which provides outstanding sample economy with a dead-time of less than 1 ms. However the cost of the equipment imposes a serious restriction to many Brazilian scientists and teachers. In this work we describe the construction of a low-cost stopped-flow system coupled to a UV-Vis spectrophotometer. The performance of the system was checked by monitoring the kinetics of two reactions: the fading of phenolphthalein in aqueous alkaline solution and the chlorophyll a demetallation in acid medium. The apparatus showed reasonable efficiency with a dead-time of 0.3 to 0.5 s. The very good results obtained in these two illustrative processes show that the system is satisfactory for determining rate constants with mean reaction times ranging from seconds to minutes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The design and use of a novel apparatus for a variant of vacuum distillation is described. Relative to a conventional device, the apparatus/technique described permits superior recovery of multigram quantities of moderately volatile liquids from vacuum distillations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This article describes the construction and optimization of an inexpensive apparatus for the production of uniform and porous chitosan microspheres. It also describes the control of the main operational parameters and strategies for the production of uniform chitosan microspheres.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The microbiological bioassay, UV-spectrophotometry and HPLC methods for assaying gatifloxacin in tablets were compared. Validation parameters such as linearity, precision, accuracy, limit of detection and limit of quantitation were determined. Beer's law was obeyed in the ranges 4.0-14.0 μg/mL for HPLC and UV-spectrophotometric method, and 4.0-16.0 μg/mL for bioassay. All methods were reliable within acceptable limits for antibiotic pharmaceutical preparations being accurate, precise and reproducible. The bioassay and HPLC are more specific than UV-spectrophotometric analysis. The application of each method as a routine analysis should be investigated considering cost, simplicity, equipment, solvents, speed, and application to large or small workloads.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This article describes a projection spectrograph for use in optical spectroscopy classrooms demonstrations. The apparatus is based on an overhead projector and permits the visualization of several phenomena such as, light dispersion by diffraction gratings, diffraction order, optical fluorescence, continuous and discrete optical emission spectra, and light absorption by liquids and solids. A historical survey about the optical spectroscopy development is also presented.