336 resultados para SPECTROPHOTOMETRIC DETERMINATION
Resumo:
A derivative UV spectrophotometric method for determination of estradiol valerate in tablets was validated. The parameters specificity, linearity, precision, accuracy, limit of detection and limit of quantitation were studied according to validation guidelines. The first-order derivative spectra were obtained at N = 5, Δλ = 4.0 nm, and determinations were made at 270 nm. The method showed specificity and linearity in the concentration range of 0.20 to 0.40 mg mL-1. The intra and interday precision data demonstrated the method has good reproducibility. Accuracy was also evaluated and results were satisfactory. The proposed method was successfully applied to a pharmaceutical formulation.
Resumo:
For determination of aliskiren in commercial samples, an analytical UV spectrophotometric method was developed and validate according to ICH guideline. The method was linear in the range between 40 and 100 μg mL-1 (r² = 0.9997, n = 7) and exhibited suitable specificity, accuracy, precision, and robustness. It is simple, it has low cost, and it has low use polluting reagents. Therefore, the proposed method was successfully applied for the assay and dissolution studies of aliskiren in tablet dosage forms, and the results were compared to a validated RP-LC method, showing non-significant difference (P > 0.05).
Resumo:
Nitrate is quantitatively retained with 2,6-bis(4-methoxyphenyl)-4-phenyl pyrylium perchlorate (PPP) on microcrystalline naphthalene in the pH range of 6.5-9.0 from a large volume of aqueous solutions of various samples. The method was based on the complexation between PPP and nitrate and then, extraction of the resulted complex from aqueous solution by microcrystalline naphthalene. The solid mass consisting of the nitrate complex and naphthalene was then dissolved in dimethyl formamide (DMF) and absorption of the resulted solution was obtained at 328 nm. The linear calibration range for the determination of nitrate was 15-135 μg L-1 with the detection limit of 10 μg L-1.
Resumo:
Sensitive and selective spectrophotometric and spectrofluorimetric methods have been developed for determination of some drugs such as Pramipexole, Nebivolol, Carvedilol, and Eletriptan, which commonly contain secondary amino group. The subject methods were developed via derivatization of the secondary amino groups with 7-Chloro-4-Nitrobenzofurazon in borate buffer where a yellow colored reaction product was obtained and measured spectrophotometrically or spectrofluorimetrically. Concentration ranges were found as 2.0 to 250 μg mL-1 and 0.1 to 3.0 μg mL-1, for spectrophotometric and spectrofluorimetric study, respectively. The described methods can be easily applied by the quality control laboratories in routine analyses of these drugs in pharmaceutical preparations.
Resumo:
A new simple and sensitive flotation-spectrophotometric method for the determination of cetylpyridinium chloride (CPC) is reported. The method is based on the formation of an ion- associate between CPC and Orange II (OR) which is floated in the interface of aqueous phase and n-hexane by vigorous shaking. The aqueous solution was discarded and the adsorbed ion associate on to the wall of a separating funnel was dissolved in a small volume of methanol solvent and its absorbance was measured at 480 nm. The apparent molar absorptivity (Ε) of the ion associate was determined to be 4.12 x 10(5) L mol-1 cm-1. The calibration graph was linear in the concentration range of 15-800 ng mL-1 of CPC with a correlation coefficient of 0.9988. The limit of detection (LOD) was 10.8 ng mL-1. The relative standard deviation (RSD) for determination of 100 and 800 ng mL-1 of CPC was 3.47 and 2.04% (n=7), respectively. The method was successfully applied to the determination of CPC in a commercial mouth washer product.
Resumo:
Two sensitive and simple spectrophotmetric methods were developed for determination of Atazanavir Sulfate in capsule dosage form. The first method was based on the oxidative coupling of ATV with 3-Methyl Benzothiazolin-2-one hydrazone (MBTH). The resulting green product had Λmax of 627.3 nm and was stable for 2 h. The second method was based on the reaction between diazotized drug with N-(1-napthyl)ethylenediamine dihydrochloride (NEDA) in neutral medium to yield yellowish orange product which had Λmax of 517.1 nm. The product was stable for 4 h. Both methods were highly reproducible and had been applied to pharmaceutical preparations.
Resumo:
This study describes the validation of UV spectrophotometric method for quantitative determination of gemifloxacin mesylate (GFM) in tablets using methanol as solvent. The method was specific, linear, precise, exact and robust at 272 and 343 nm. The results confirmed that the method in both wavelengths is valid and useful to the routine quality control of GFM in coated tablets. The validate method was compared to liquid chromatography (HPLC), microbiological assay and visible (VIS) spectrophotometry, which were previously developed and validated to the same drug. There was not significative difference between the methods for GFM quantitation.
Resumo:
A derivative spectrophotometric method was validated for quantification of acyclovir in poly (n-butylcyanoacrylate) (PBCA) nanoparticles. Specificity, linearity, precision, accuracy, recovery, detection (LOD) and quantification (LOQ) limits were established for method validation. First-derivative at 295.2 nm eliminated interferences from nanoparticle ingredients and presented linearity for acyclovir concentrations ranging from 1.25 to 40.0 µg/mL (r = 0.9999). Precision and accuracy data demonstrated good reproducibility. Recovery ranged from 99.3 to 101.2. LOD was 0.08 µg/mL and LOQ, 0.25 µg/mL. Thus, the proposed method proved to be easy, low cost, and accurate, and therefore, an useful alternative to quantify acyclovir in nanoparticles.
Resumo:
A spectrophotometric method based on the formation of ion-pair complex between haloperidol and eriochrome black T (EBT) at pH 1.85 has been described. The formed complex was extracted quantitatively into chloroform and measured at 510 nm. Infra red (IR) studies were performed to confirm the formation of ion-pair complex. Beer's law was obeyed in the concentration range of 2.0-9.0 µg mL-1 with molar absorptivity of 2.67 × 10(4) L mol-1 cm-1. The detection limit was found to be 0.18 µg mL-1. Statistical comparison of the results of the proposed method with those of the reference method shows excellent agreement and indicates no significant difference in accuracy and precision.
Resumo:
A direct, extraction-free spectrophotometric method has been developed for the determination of acebutolol hydrochloride (ABH) in pharmaceutical preparations. The method is based on ion-pair complex formation between the drug and two acidic dyes (sulphonaphthalein) namely bromocresol green (BCG) and bromothymol blue (BTB). Conformity to Beer's law enabled the assay of the drug in the range of 0.5-13.8 µg mL-1 with BCG and 1.8-15.9 µg mL-1 with BTB. Compared with a reference method, the results obtained were of equal accuracy and precision. In addition, these methods were also found to be specific for the analysis of acebutolol hydrochloride in the presence of excipients, which are co-formulated in the drug.
Resumo:
A spectrophotometric flow injection method for the determination of paracetamol in pharmaceutical formulations is proposed. The procedure was based on the oxidation of paracetamol by sodium hypochloride and the determination of the excess of this oxidant using o-tolidine dichloride as chromogenic reagent at 430 nm. The analytical curve was linear in the paracetamol concentration range from 8.50 x 10-6 to 2.51 x 10-4 mol L-1 with a detection limit of 5.0 x 10-6 mol L-1. The relative standard deviation was smaller than 1.2% for 1.20 x 10-4 mol L-1 paracetamol solution (n = 10). The results obtained for paracetamol in pharmaceutical formulations using the proposed flow injection method and those obtained using a USP Pharmacopoeia method are in agreement at the 95% confidence level.
Resumo:
A simple, rapid and sensitive spectrophotometric method has been developed for the determination of methyldopa in pharmaceutical formulations. The method is based on the reaction between tetrachloro-p-benzoquinone (p-chloranil) and methyldopa, accelerated by hydrogen peroxide (H2O2), producing a violet-red compound (λmax = 535 nm) at ambient temperature (25.0 ± 0.2 ºC). Experimental design methodologies were used to optimize the measurement conditions. Beer's law is obeyed in a concentration range from 2.10 x 10-4 to 2.48 x 10-3 mol L-1 (r = 0.9997). The limit of detection was 7.55 x 10-6 mol L-1 and the limit of quantification was 2.52 x 10-5 mol L-1. The intraday precision and interday precision were studied for 10 replicate analyses of 1.59 x 10-3 mol L-1 methyldopa solution and the respective coefficients of variation were 0.7 and 1.1 %. The proposed method was successfully applied to the determination of methyldopa in commercial brands of pharmaceuticals. No interferences were observed from the common excipients in the formulations. The results obtained by the proposed method were favorably compared with those given by the Brazilian Pharmacopoeia procedure at 95 % confidence level.
Resumo:
Highly sensitive and selective spectrophotometric methods (A and B) were developed for the determination of micro amounts of olanzapine (OLZ). Method A (direct method) is based on the oxidation of olanzapine with a known excess of iodine monochloride (ICl) in an acidic medium. Under the same condition, thymol blue was iodinated by unreacted ICl, and the absorbance of uniodinated thymol blue was measured at 536 nm. The decrease in ICl concentration is a measure of drug concentration. In method B (indirect method), oxidation of OLZ by a known excess of Ce(IV) in sulfuric acid medium followed by the reaction of unreacted Ce(IV) with leuco crystal violet (LCV) to crystal violet (CV), which is measured in an acetate buffer medium ( pH 4.9) at 580 nm. These methods obey the Beer's law in the concentration range of 0.2-1.6 µg mL-1 (method A) and 0.1-1.4 µg mL-1 (method B). The developed procedures have been successfully applied to the determination of OLZ in pure and in dosage forms. The results exhibit no interference from the presence of excipients. The reliability of the methods was established by parallel determination of OLZ against the reference method.
Resumo:
A spectrophotometric flow injection method for the determination of Zn(II) in ophthalmic formulations was developed. In this work, Zn(II) ion was complexed with Alizarin red S in borate buffer solution (pH 9.0) and the chromophore produced was monitored at 520 nm. The analytical curve was linear in the Zn(II) concentration range from 6.05 x 10-6 to 1.50 x 10-4 mol L-1 with a detection limit of 3.60 x 10-6 mol L-1. Recoveries ranged from 96.3 to 105 % and a relative standard deviation of 1.2 % (n = 10) for 5.5x10-5 mol L-1 Zn(II) reference solution were obtained. The sampling rate was 60 h-1 and the results obtained of Zn(II) in ophthalmic products using this procedure are in close agreement with those obtained using a comparative spectrophotometric procedure at 95 % confidence level.
Resumo:
A novel sensitive and relatively selective kinetic method is presented for the determination of V(V), based on its catalytic effect on the oxidation reaction of Ponceau Xylydine by potassium bromate in presence of 5-sulfosalicylic acid (SSA) as activator. The reaction was monitored spectrophotometrically by measuring the decrease in absorbance of Ponceau Xylydine at 640 nm between 0.5 to 7 min (the fixed time method) in H3PO4 medium at 25ºC. The effect of various parameters such as concentrations of H3PO4, SSA, bromate and Ponceau Xylydine, temperature and ionic strength on the rate of net reaction were studied. The method is free from most interferences, especially from large amounts of V(IV). The decrease in absorbance is proportional to the concentration of V(V) over the entire concentration range tested (1-15 ng mL−1) with a detection limit of 0.46 ng mL-1 (according to statistical 3Sblank/k criterion) and a coefficient of variation (CV) of 1.8% (for ten replicate measurement at 95% confidence level). The proposed method suffers few interferences such as Cr(VI) and Hg(II) ions. The method was successfully applied to the determination of V(V) in tap water, drinking water, bottled mineral water samples and a certified standard reference material such as SRM-1640 with satisfactory results. The vanadium contents of water samples were also determined by FAAS for a comparison. The recovery of spiked vanadium(V) was found to be quantitative and the reproducibility was satisfactory. It was observed that the results of the SRM 1640 were in good agreement with the certified value.