Spectrophotometric flow injection system for determination of Zn2+ in ophthalmic formulations using Alizarin red S


Autoria(s): Fatibello-Filho,Orlando; Vieira,Heberth Juliano
Data(s)

01/01/2009

Resumo

A spectrophotometric flow injection method for the determination of Zn(II) in ophthalmic formulations was developed. In this work, Zn(II) ion was complexed with Alizarin red S in borate buffer solution (pH 9.0) and the chromophore produced was monitored at 520 nm. The analytical curve was linear in the Zn(II) concentration range from 6.05 x 10-6 to 1.50 x 10-4 mol L-1 with a detection limit of 3.60 x 10-6 mol L-1. Recoveries ranged from 96.3 to 105 % and a relative standard deviation of 1.2 % (n = 10) for 5.5x10-5 mol L-1 Zn(II) reference solution were obtained. The sampling rate was 60 h-1 and the results obtained of Zn(II) in ophthalmic products using this procedure are in close agreement with those obtained using a comparative spectrophotometric procedure at 95 % confidence level.

Formato

text/html

Identificador

http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0100-46702009000200008

Idioma(s)

en

Publicador

Fundação Editora da Universidade Estadual Paulista Júlio de Mesquita Filho - UNESP

Fonte

Eclética Química v.34 n.2 2009

Palavras-Chave #Flow injection analysis #Zinc(II) #Alizarin red S #spectrophotometry #ophthalmic formulations
Tipo

journal article