801 resultados para operações de determinação e indeterminação


Relevância:

20.00% 20.00%

Publicador:

Resumo:

In honey 5-hydroxymethyl-2-furaldehyde (HMF) is one of the most typical products of degradation: it is usually absent in fresh honey, but its concentration tends to rise as a result of heating processes or long-term storage. The validation protocol was performed in terms of detection and quantification limits, precision (by repeatability and intermediate precision), linearity and accuracy (by recovery tests). The method has been tested on 15 honey samples of different ages and geographical origin. HMF correlated highly with the age of the samples has been considered a very important parameter to put these honeys on the market or not and/or to estimate their shelf life.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An analytical procedure for determination of estriol, 17β-estradiol, estrone and 17α-ethinylestradiol in drinking water is presented. The method employs solid phase extraction (SPE) and sample dechlorination as cleanup procedures, followed by HPLC-DAD analysis. Validation was carried out using RE No. 899/2003 guidelines established by the Agência Nacional de Vigilância Sanitária (National Agency of Sanitary Surveillance, Brazil), with some adaptations. The statistically evaluated results have shown that the method is selective, precise (0,06% to 19,40% CV) and accurate (91,52% to 109,41% average recoveries). The developed method was applied to the analysis of these contaminants in drinking water from São Luís, MA.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work proposed a procedure to examine ashes produced in burning lubricating oils used in public transportation, in Teresina PI. Sulphanilic acid was added to the oil samples, which were burned at 550 °C for three hours and 650 °C for two hours. The ash solutions were analyzed by FAAS and there were significant differences in the metal contents of the waste oil produced from normal car service. The quantification limits in μg g-1 were 5.9 (Fe), 4.4 (Pb), 1.7 (Ni), 2.1 (Cu), and 1.2 (Zn). The results showed positive accuracy and precision with recoveries between 88 and 108%, and RSD lower than 10%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work a new method (SPME-GC/FID) was developed to analyze the activity of binary liquid mixtures. The purpose is to demonstrate that SPME is capable to be used to determinate activity coefficients at infinite dilution knowing the fiber properties, with a lower cost than the conventional methods encountered in literature such as GLC. The activity coefficients at infinite dilution in furfural for n-hexane, n-heptane and cyclohexane at 298.15 K was determined using SPME and deviations of literature data was about 7%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, we analyze the use of electrical impedance spectroscopy applied to determination of cloud point. The slope of admittance measured at 100 kHz is reduced to temperature above the critical value which characterizes the phase transition, in a strong indication that this process is activated during the clouding. Additionally to this study we explored the influence of parameters such as additives and temperature on the performance of phase separation of residues (silver nanoparticles) by cloud point extraction. The interaction with salt maximizes the separation of chemical residues in a progressively reduced temperature.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the literature there are a considerable number of chemical and biochemical tests for evaluation of in vitro antioxidant activities of pure compounds or fractions and organic extracts. These tests are important tools for screening of synthetic and natural bioactive compound as well as they can be employed in food chemistry. This work is a critical review of the main methods employed for in vitro antioxidant determination.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The potentiality of the use of ultrasound radiation in association with a boron-doped diamond electrode was evaluated on the voltammetric determination of the pesticide carbaryl. Improvements in the sensitivity, limit of detection and reproducibility of the measurements were observed due to both, the enhancement of mass transport and the cleaning of the electrode surface provided by ultrasound. Satisfactory recovery levels for carbaryl in pure water (96-98%) and pineapple juice (89-92%) for quiescent and sonovoltammetric methodologies were obtained. These methodologies can be alternative tools for the analyses of pesticides in fruit samples, mainly the insonated condition that improve the analytical performance and dispense intermediary cleanings of the electrode surface.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Chicken meat is largely consumed in human nutrition and it is produced in extremely large scale in some countries, including Brazil. In this work graphite furnace atomic absorption spectrometry was used for determination of arsenic in chicken and chicken production-related samples. These samples were digested employing a microwave-assisted procedure in closed vessels using a 7 mol L-1 nitric acid solution plus concentrated hydrogen peroxide. The concentration range of total As determined in chicken production-related samples varied from 1.30 to 29.8 mg kg-1 of As. The detection and quantification limits reached were 0.055 and 0.182 mg kg-1, respectively (n = 15).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work proposes a separation, recovery and reuse procedure of chemical residues with chromium. This residue was generated by the determination of oxidizable carbon in organic fertilizers samples. The Cr(VI) of the residue was reduced with ethanol and precipitated with NaOH. The Cr(OH)3 precipitate was separated and oxidized to dichromate ions with hydrogen peroxide. This solution was used another time in organic carbon determination. The uses of recycled dichromate solution were appropriated in four successive recycling. The accuracy was proven using potassium hydrogen phthalate and ten organic fertilizer samples. The organic carbon results, determined with recycled solutions, were similar the conventional solution.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A method for quantifying urinary 2,5-hexanedione was optimized and validated. Urine samples were hydrolyzed and derivatized with 2,4-dinitrophenylhydrazine. The analyte was separated in a high performance liquid chromatography system with a diode array detector, using a C18 column (150 x 4.6 mm, p.d. 5 µm) and a mobile phase composed of phosphate buffer pH 2.3:acetonitrile (40:60, v/v), at a flow rate of 1 mL/min. The chromatograms were monitored at 334 nm. Retention time was 7.3 minutes. Main validation parameters were: coefficient of determination: 0.9994, accuracy: 96 to 107%; intra-assay precision (RSD): 3.08 to 6.72%; inter-assay precision (RSD): 2.54 to 8.17% and limit of quantitation of 0.19 µg/mL.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work deals with the method validation for the determination of acetic, propionic and butyric acids (VFAs) in wastewaters from anaerobic reactors by HPLC-DAD. Separation was performed using a C18 column and the mobile phase composition were water pH 3.0 and methanol 90:10 (v/v). The detection and quantification was carried out at 220 nm. The method shows good linearity (r²>0.996), with adequate accuracy (89-102%) and relative standard deviations lower than 18%. The matrix effect was considered low (-4.1, -3.9 and 1.4%). The developed method is fast, simple and cheap; and it was applied in wastewater samples from anaerobic reactor.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Asphaltenes are fractions of crude oils that can precipitate and one of the parameters used in the prediction of the conditions in which this phenomenon occurs is the Hildebrand solubility parameter. In this work, it was evaluated the uncertainty propagation in the experimental determination of the solubility parameter of different crude oils, calculated from data of the asphaltenes precipitation by the addition of n-heptane, identified by optical microscopy. It was verified that the solubility parameter of an oil and the associated uncertainty are specific, being recommended that, whenever viable, it is determined parallel both, conferring higher credibility to the results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A method for simultaneous analysis of trihalomethanes and organochloride and pyrethroid pesticides in water utilizing SPME-HS and GC-ECD was developed. In the optimized method 25 mL of water containing 2% (w/v) Na2HPO4 were heated to 60 °C for 50 min. The fiber (PDMS - 100 μm) was exposed to a headspace for the same period. For all analytes it was found that LOQ < MCL (Maximum Contaminant Level), CV < 20% and r > 0.9. The method was applied to potable and surface water samples. Some trihalomethanes were encountered in potable waters, at levels below the MCL.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Multivariate models were developed using Artificial Neural Network (ANN) and Least Square - Support Vector Machines (LS-SVM) for estimating lignin siringyl/guaiacyl ratio and the contents of cellulose, hemicelluloses and lignin in eucalyptus wood by pyrolysis associated to gaseous chromatography and mass spectrometry (Py-GC/MS). The results obtained by two calibration methods were in agreement with those of reference methods. However a comparison indicated that the LS-SVM model presented better predictive capacity for the cellulose and lignin contents, while the ANN model presented was more adequate for estimating the hemicelluloses content and lignin siringyl/guaiacyl ratio.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The gravimetric and electrochemical tests are the most common techniques used in determining the corrosion rate. However, the use of electrochemical polarization is limited to electrolytes with sufficient conductivity for which Tafel curves are linear. In this study, we investigated a technique in which working microelectrodes of AISI 1020 steel were used to obtain the Tafel curves in diesel oil. The strategy was to reduce the electrode area and hence the ohmic drop. The diameter of the microelectrode was reduced to a value where the compensation of the Tafel curves became unnecessary. The results showed that for electrodes with diameters below 50 μm, the ohmic drop tends to a minimum and independent of the microelectrode diameter.