362 resultados para Circuitos integrados de alta velocidade


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This article describes the use of a conventional CRT monitor as a high voltage power supply for capillary electrophoresis. With this monitor, a 23-kV high voltage with a ripple of 1.32% was observed. The reproducibility of the applied high voltage was evaluated by measuring the standard deviations of peak area and migration time for five consecutive injections of a test mixture containing potassium, sodium, and lithium cations at 50 mmol L-1. The errors were about 2.5% and 0.6% for peak area and migration time, respectively. The maximum current tested was about 180 mA, which covers most capillary electrophoresis applications. This system has been successfully used for several months, maintaining the desired level of performance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A rapid and efficient method for the analysis of histamine in wines using HPLC with fluorescence detection after derivatization was developed and validated. The method LOD and LOQ values were 0.25 and 0.50 mg L-1 respectively. The repeatability and intermediary precision for the instrument and for the method presented RSD values of 3.7 and 2.9%, and 6.0 and 5.6%, respectively. The recoveries were 95.5 and 89.9% for the fortification levels of 2 and 10 mg L-1. The method was applied to determine the histamine content in Cabernet Sauvignon wines, which presented values between 1.2 and 5.7 mg L-1.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A method for HPLC determination of sulfadimethoxyne in milk is presented. The analyte isolation and concentration were performed by solid-phase extraction through a C-8 cartridge, pre-conditioned with hexane, methanol and water and eluted with MeOH. The recovery determination was done with a spiked solution of 20, 50 or 100 µg L-1. In this concentration range, the recovery was 83.2% with a RDS of 15.4%. For quantification, a Zorbax Eclipse XDB-C8 (4.6 mm x 150 mm, 5 µm), a mobile phase of MeCN: 0.01 mol L-1 KH2PO4 aq. (1:4), and a variable wavelength detector (275 nm) were used.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Synthetic dyes are much used in processed foods. HPLC was applied to different types of snacks, such as colored cereals, chocolate confetti, chewing gums and candies for the determination of those additives. In the case of artificially colored breakfast cereals, 71% of the samples exceeded the allowed limits. Regarding the portions recommended for consumption by the makers of two of the samples, the amounts exceeded those allowed by the Brazilian legislation. In the case of chocolate confetti and candies none of the samples showed higher amounts than those allowed. However 37% of the chewing gum samples presented larger contents than the authorized ones, and one sample contained five times more synthetic dyes than allowed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Paclobutrazol is a plant growth retardant which is used world-wide for increasing the yield of cereal crops. However, this compound remains active in the soil for several years and can severely affect the growth and development of subsequent crops, mainly by reducing vegetative vigor. The aim of this work was to develop and validate methods for the determination of paclobutrazol concentrations by both high performance liquid chromatography and spectroscopy. Both methods were satisfactory and showed appropriately low quantification limits. The determination by spectroscopy has, however, the advantage of being a method significantly less expensive than high performance liquid chromatography.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An HPLC method was validated to assay lamivudine and zidovudine combined in tablets. The chromatographic separation was carried out using methanol and acetate buffer pH 6.5 (50:50 v/v) and a RP-18 column, as mobile and stationary phase, respectively. The UV detection was at 270 nm. The method was linear in the range of 24 - 36 µg/mL (lamivudine) and 48 - 72 µg/mL (zidovudine). The recovery (accuracy) ranged from 101.35% to 103.04% and the precision (repeatability and intermediate precision) was less than 2%. The method can be also applied to the quantification of these drugs in the dissolution test of tablets containing both drugs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this work was to develop and validate an analytical methodology for simultaneous determination of mebendazole and thiabendazole, two benzimidazoles used as anthelmintics. The method was based on high performance liquid chromatography, using a C18 column, a mobile phase composed of KH2PO4 0.05 mol L-1 and methanol 40:60 (v/v) and UV detection at 312 nm. The results showed that the method presented linearity from 60.0 to 140.0 µg mL-1 for mebendazole and from 99.6 to 232.4 g µL-1 for thiabendazole and it was considered selective, accurate, precise and robust according to the specific resolution from ANVISA, the Brazilian regulatory agency.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Electron stimulated ion desorption (ESID) and degradation studies of polypyrrole doped with dodecylsulfate (PPy/DS) deposited on FTO were performed using time-of-flight mass spectrometry (TOF-MS) for ion analysis. The results suggest a strong contribution from fragments of the dodecylsulfate hydrocarbon chain to the mass spectra. In the 650-1500 eV energy range the ion yield curves show maxima at about 600, 1200 and 1400 eV, which can be related to carbon, nitrogen and oxygen-containing fragments, respectively, and interpreted in terms of the Auger Stimulated Ion Desorption (ASID) mechanism. Degradation studies indicate rapid loss of heavier hydrocarbons and an increase of bulk and substrate fragments. Some degradation profiles suggest formation of new species.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a simple and practical thermogravimetric method for determining the layer thickness of immobilized polymer stationary phases used in reversed-phase high-performance liquid chromatography. In this method, the weight loss of different polysiloxanes immobilized onto chromatographic supports, determined over the temperature range 150-650 ºC, demonstrated excellent agreement with the sum of carbon and hydrogen content obtained by elemental analysis. The results presented here suggest that the thermogravimetric procedure is an accurate and precise method to determine the polymeric material content on polymer-coated stationary phases.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pb/Ti, Sn and Mg-based nanocomposite materials were prepared by the high-energy mechanical milling of commercial powders. The surface of these ceramic compounds was strongly influenced by the doping, diameter of the milling spheres and time of the mechanical milling (amorphization process). Such milling leads to the formation of nanocrystalline materials. The mechanical processing parameters of these compounds were investigated through Brunauer, Emmett and Teller isotherms, wide angle X-ray diffraction, transmission electron microscopy and CO2 adsorption.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An analytical method has been developed and validated for the quantitation of lamivudine, zidovudine and nevirapine in the fixed-dose combination film-coated tablet by high performance liquid chromatography, in accordance with RE No. 899/2003, National Sanitary Surveillance Agency. It was based on an isocratic elution system with a potassium phosphate buffer pH 3.0: acetonitrile (60:40 v/v) mobile phase, C18, 250 x 46 mm column, 10µm particle size, λ 270 nm. The statistically evaluated results have shown that the method is specific, precise, accurate, and robust, ensuring the analytical safety of 3TC, AZT and NVP determination, which emerges as a new therapeutic alternative for antiretroviral treatment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Biological monitoring is very important to guarantee health to workers. This method was developed for simultaneous determination of xylene, toluene, styrene and ethylbenzene metabolites. It involves only dilution and centrifugation of urine samples and improved chromatographic conditions. Analyses show recovery > 95%; r² > 0.99; intermediate precision CV% < 6% and % bias < ±10. Exposed subjects presented at least three metabolites in urine. The method proved to be feasible, reliable and important in biological monitoring, especially in exposure to organic solvent mixtures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Three technologies were tested (TiO2/UV, H2O2/UV, and TiO2/H2O2/UV) for the degradation and color removal of a 25 mg L-1 mixture of three acid dyes: Blue 9, Red 18, and Yellow 23. A low speed rotating disc reactor (20 rpm) and a H2O2 concentration of 2.5 mmol L-1 were used. The dyes did not significantly undergo photolysis, although they were all degraded by the studied advanced oxidation processes. With the TiO2/H2O2/UV process, a strong synergism was observed (color removal reached 100%). Pseudo first order kinetic constants were estimated for all processes, as well as the respective apparent photonic efficiencies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work optimized the HPLC conditions for the simultaneous determination of luteolin, apigenin, myricetin, quercetin and kaempferol in aglycone form, as well defined the best conditions for hydrolysis/extraction of these flavonoids in fruits, using the statistical central composite design and response surface analysis. A reverse phase method was developed using a gradient of methanol/water acidified with 0.3% formic acid as mobile phase and a photodiode array detector. The samples were extracted with methanol/water (50:50 v/v) at 90 ºC. The optimum time and HCl concentration varied for the different fruits investigated, demonstrating the necessity of optimizing these conditions for each fruit analyzed. Good recovery (87.1 to 96.3%), repeatability and linearity were obtained.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A HPLC method was developed to quantify thymine and thymidine impurities in stavudine bulk drug. The separation was carried out in isocratic mode using methanol/water (20:80) as mobile phase, a C18 column and UV detection at 266 nm. The method provided selectivity based on peak purities and resolution among peaks. It was linear over the range of 0.5-5.0 µg/mL. The quantitation limits were 0.021 µg/mL for thymine and 0.134 µg/mL for thymidine. The average accuracies of three concentrations ranged from 97.06 to 102.61% and precision was close to 1%. The method showed robustness, remaining unaffected by deliberate variations in relevant parameters.