266 resultados para vasodilatação mediada por fluxo
Resumo:
A flow system based on the sandwich technique is proposed for the sequential determination of ascorbic acid, dipyrone, acetylcysteine, captopril and paracetamol. The procedure is based on the reduction of Cu(II) by the analytes followed by the spectrophotometric measurement of the complex of Cu(I) with 2,2'-biquinoline 4,4'-dicarboxylic acid. Linear responses were achieved in the µmol L-1 range, with coefficients of variation better than 1.7%. Sampling rate was estimated as 60 determinations per hour, consuming 230 µg of BQA and generating 2.5 mL of waste per determination. Results for commercial samples agreed with those obtained by procedures recommended by the American and European pharmacopeias at the 95% confidence level.
Resumo:
The potentialities and applications of the Multiple Pulse Amperometric detection (MPA) coupled with Flow Injection Analysis (FIA) are evaluated. Important aspects as cleaning and activation of electrode surface, indirect and simultaneous analysis of electroactive compounds and the use of the internal standard method for quantifications utilizing FIA-MPA are presented. The main parameters concerning the detection of electroactive analytes by multiple pulse amperometric detection in flowing solutions were also discussed. In addition, aspects such as flow rate, sample volume, application time of the potential pulses and instrumentation necessary for implementing of the method were also addressed.
Resumo:
A flow injection spectrophotometric procedure for the determination of glyphosate in commercial formulations of herbicides is proposed. The determination is based on the reaction of glyphosate and p-dimethylaminocinnamaldehyde, in acid medium, yielding a colored compound (l máx = 495 nm). Under optimal conditions, Beer's law is obeyed in a concentration range 40-640 mg mL-1 with a correlation coefficient of 0.9996. The detection limit was 8.60 mg mL-1 for glyphosate. The method was successfully applied for the determination of glyphosate in commercial formulations of herbicides. Recovery of glyphosate from various commercial samples of herbicides range from 91.0 to 110%.
Resumo:
A simple flow system with multiple pulse amperometric detection using a single working electrode is proposed for simultaneous determination of ascorbic (AA) and acetylsalicylic (AAS) acids in pharmaceutical formulations. The procedure is based on application of two potential pulses: 0.90 V/50 ms: oxidation and determination of AA without the interference of AAS; 1.35 V/50 ms: oxidation of both compounds and quantification of AAS by current subtraction using a correction factor. Sampling rate was estimated as 125 injections per hour and the limits of detection were 0.17 and 0.16 µmol L-1 for AA and AAS, respectively. Results for commercial samples agreed with those obtained using HPLC.
Resumo:
A multi-commuted flow system was developed to determine propylthiouracil (PTU) based on the reaction of its thiol form with iminoquinone radical generated by the oxidation of N,N-dimethyl-p-phenylenediamine in an alkaline medium. PTU can be found in tautomeric forms and the tautomeric equilibrium was displaced to enhance the thiol form. However, the reaction product is unstable and its residence time in the flow path was carefully investigated. The proposed procedure showed good precision (< 1.5%) and a limit of detection (3s) of 0.11 mg L-1. High recoveries were obtained in the validation test. The procedure was employed for propylthiouracil determination in medications.
Resumo:
A didactic experiment is proposed aimed to extend the Flow Injection Analysis (FIA) based methodology to the area of physical chemistry/chemical reactors for undergraduate labs. Our prime objective was to describe the use of a gradient chamber for determination of the rate constant for the reaction between crystal violet and the hydroxide ion. The study was complemented by determining the effect of temperature on the rate constant. The kinetic parameters, activation energy and reaction rate constant are determined based on an assumption of rate orders. The main didactic advantages of the proposed experimental set-up are the use of less reagents, contributing to a more environmental friendly experiment. The experiment illustrates also the reduction of associated errors and time by using automated analysis owing to decreased operator manipulation.
Produção de concentrados de ácidos graxos por hidrólise de óleos vegetais mediada por lipase vegetal
Resumo:
The aim of this work was to verify the ability of enzymatic crude extract from dormant castor bean seeds to yield concentrated fatty acids by hydrolysis of polyunsaturated vegetable oils such as corn and sunflower. The enzymatic extract exhibited higher activity towards corn oil, which was selected for further studies to determine optimum hydrolysis conditions by factorial design. Maximum hydrolysis percentage (≈84%) was reached at 60% wt. oil:buffer acetate 100 mM pH 4.5, 33 ºC and 5.0% wt. of crude extract after 70 min of reaction. These results suggest that the use of low-cost lipase from castor bean seeds has potential for oil hydrolysis.
Resumo:
This paper describes the use of the open source hardware platform, denominated "Arduino", for controlling solenoid valves for solutions handling in flow analysis systems. System assessment was carried out by spectrophotometric determination of iron (II) in natural water. The sampling rate was estimated as 45 determinations per hour and the coefficient of variation was lower than 3%. Per determination, 208 µg of 1-10-phenanthroline and ascorbic acid were consumed, generating 1.3 mL of waste. "Arduino" proved a reliable microcontroller with low cost and simple interfacing, allowing USB communication for solenoid device switching in flow systems.
Resumo:
A simple and fast method for the determination of nimesulide (NI) using flow injection analysis with multiple-pulse amperometric (FIA-MPA) detection at a boron-doped diamond (BDD) electrode was developed. The method was based mainly on the application of a four-potential waveform, E1(det) = -0.8 V / 30 ms, E2(det) = 0.6 V / 30 ms, E3(det) = -0.4 V / 30 ms and E4(cleaning) = -0.45 V / 300 ms versus Ag/AgCl (3.0 mol L-1 KCl). NI was detected at three different electrode potentials, at which the nitro group undergoes different redox reactions. The proposed method was selective and sensitive (detection limit of 81.0 nmol L-1), and successfully applied for the determination of NI in pharmaceutical formulations, yielding similar results to those obtained by the reference method.
Resumo:
This work describes a simple and inexpensive flow injection analysis system in which gravity force provides fluid propulsion while needles for insulin administration or metallic wires act as electrodes for amperometric detection. The proposed system was able to demonstrate the influence of several operational parameters on the transient signals. Moreover, this system was successfully used to evaluate both the stoichiometry of Cu2+-EDTA complex and the effect of pH on the kinetics of the reaction between ferricyanide and ascorbic acid. Therefore, the proposed system can be regarded as an efficient and accessible didactic tool for the teaching of FIA principles.
Resumo:
AbstractA device comprising a lab-made chamber with mechanical stirring and computer-controlled solenoid valves is proposed for the mechanization of liquid-liquid extractions. The performance was demonstrated by the extraction of ethanol from biodiesel as a model of the extraction of analytes from organic immiscible samples to an aqueous medium. The volumes of the sample and extractant were precisely defined by the flow-rates and switching times of the valves, while the mechanic stirring increased interaction between the phases. Stirring was stopped for phase separation, and a precise time-control also allowed a successful phase separation (i.e., the absence of the organic phase in the aqueous extract). In the model system, a linear response between the analytical response and the number of extractions was observed, indicating the potential for analyte preconcentration in the extract. The efficiency and reproducibility of the extractions were demonstrated by recoveries of ethanol spiked to biodiesel samples within 96% and 100% with coefficients of variation lower than 3.0%.
Resumo:
In the past few years, photoredox catalysis has become a powerful tool in the field of organic synthesis. Using this efficient method, it is possible to excite organic compounds from visible light and attain alternative mechanistic pathways for the formation of chemical bonds, a result which is not obtainable by classical methods. The rapid growth of work in the area of photoredox catalysis is due to its low cost, broad chemical utility protocols, and, especially, its relevancy from the green and sustainable chemistry viewpoints. Thus, this study proposes a brief theoretical discussion of and highlights recent advances in visible-light-induced photoredox catalysis through the analysis of catalytic cycles and intermediates.
Resumo:
A indução de resistência sistêmica mediada por rizobactérias promotoras do crescimento de plantas foi avaliada para a ferrugem do eucalipto (Eucalyptus spp.) causada por Puccinia psidii. Para isso, mudas com cerca de 80 dias de idade, previamente enraizadas em substrato tratado com diferentes isolados de rizobactérias foram inoculadas com uma suspensão de inóculo de P. psidii ajustada para 2 x 10(4) urediniósporos/ml. As plantas inoculadas foram mantidas em câmara de nevoeiro com nebulização intermitente a 25 ºC, no escuro por 24 h, e posteriormente transferidas para câmara de crescimento a 22 ºC, com fotoperíodo de 12 h e intensidade luminosa de 40 mmoles.s-1.m-2. Utilizou-se um delineamento inteiramente casualizado com quatro repetições, cada uma delas com quatro plantas. Após 13 dias da inoculação, avaliaram-se número médio de pústulas/folha, número de uredínias/amostra e número médio de esporos produzidos/uredínia. Os isolados FL2 e MF4 foram eficientes na redução da severidade da ferrugem. Além disso, o tratamento das mudas com rizobactérias, apenas uma semana antes da inoculação, com P. psidii foi menos eficiente em reduzir a severidade da doença do que o tratamento em que foram utilizadas mudas produzidas em substrato previamente rizobacterizadas, ou seja, com 80 dias. Estes resultados indicam que estes isolados de rizobactérias podem induzir maior resistência a doenças foliares diminuindo a necessidade de aplicação de fungicidas e otimizando a produção de mudas clonais de eucalipto.
Resumo:
Visando explorar a mutagênese insercional em Magnaporthe grisea, foram avaliadas a transformação dos protoplastos obtidos após adequação do protocolo e a eficiência da integração de pAN7-1 no genoma do ascomiceto na presença da enzima de restrição Hind III. Os protoplastos de M. grisea I-22 foram prontamente transformados para a resistência à higromicina. Quando o vetor linearizado com Hind III foi usado para transformar o fungo na presença de Hind III, a eficiência de transformação foi 1,1 a 8,1 vezes superior ao tratamento sem a adição da enzima. No geral, a melhor concentração de Hind III foi 5 unidades/reação de transformação. Tal concentração promoveu a produção média de 332 transformantes/µg de pAN7-1/10(7) protoplastos. A presença do gene de seleção hph no genoma de 18 indivíduos resistentes à higromicina foi confirmada por PCR.
Resumo:
Um sistema de injeção em fluxo envolvendo complexação com dietilditiofosfato de amônio e sorção de complexos metálicos em minicolunas de sílica gel modificada por grupos octadecil C18 é proposto para determinações multielementares em espectrometria de massa com plasma indutivamente acoplado. Influência da concentração de reagentes, natureza do ácido, tempo de reação, tempos de comutação, vazões e interferência de sódio foram investigadas. Água ou solução 2% v/v HNO3 podem ser utilizadas para lavar a coluna antes da eluição dos analitos com etanol. Amostras contendo 5000 mg Na L-1 e analisadas diretamente com o sistema proposto produzem uma concentração aparente de 63Cu de 0,45 µg L-1; por outro lado não foi observada interferência para As, Pb, Bi, Se, In, Tl, Cd, Hg e 65Cu. Para 0,25 % w/v NH4DTP e 3 mL de solução de amostra, curvas analíticas para Bi, Cu, Pb, As, Se, In, Tl, Cd, Hg no intervalo de 0,10 a 2,00 µg L-1 podem ser construídas com boas correlações (r2 > 0.998). A velocidade analítica e sensibilidade podem ser melhoradas pois dependem das condições de pré-concentração e eluição selecionadas. Com os parâmetros acima fixados, limites de detecção de 0.014 (Cu), 0.027 (As), 0.06 (Se), 0.02 (Cd), 0.029 (In), 0.043 (Hg), 0.02 (Tl), 0.06 (Pb) e 0.002 µg L-1 (Bi) foram obtidos.