219 resultados para determination of value


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Two simple and sensitive spectrophotometric methods (M1 and M2) for the determination of mosapride in pure and in pharmaceutical preparations are described. These methods are based on the interaction of diazotized mosapride (MSP) couples with chromotropic acid (CTA) [M1] in alkaline medium and diphenylamine (DPA) [M2] in acidic medium. The resulting azo-dyes exhibit maximum absorption at 560 nm and at 540 nm for methods M1 and M2, respectively. All variables were studied in order to optimize the reaction conditions. No interferences were observed from excipients, and the validity of the each method was tested against reference method.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

National Health Surveillance Agency (ANVISA) established in the decree number 54 maximum allowed levels for Ni and Pb in mineral and natural waters at 20 µg L-1 and 10 µg L-1, respectively. For screening analysis purposes, the high-resolution continuum source flame atomic absorption spectrometry technique (HR-CS FAAS) was evaluated for the fast-sequential determination of nickel and lead in mineral waters.Two atomic lines for Ni (232.003 nm - main and 341.477 nm - secondary) and Pb (217.0005 nm - main and 283.306 nm - secondary) at different wavelength integrated absorbance (number of pixels) were evaluated. Sensitivity enhanced with the increase of the number of pixels and with the summation of the atomic lines absorbances. The main figures of merit associated to the HR-CS FAAS technique were compared with that obtained by line-source flame atomic absorption spectrometry (LS FAAS). Water samples were pre-concentrated about 5-fold by evaporation before analysis. Recoveries of Pb significantly varied with increased wavelength integrated absorbance. Better recoveries (92-93%) were observed for higher number of pixels at the main line or summating the atomic lines (90-92%). This influence was irrelevant for Ni, and recoveries in the 92-104% range were obtained in all situations.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Two sensitive spectrophotometric methods are described for the determination of simvastatin (SMT) in bulk drug and in tablets. The methods are based on the oxidation of SMT by a measured excess of cerium (IV) in acid medium followed by determination of unreacted oxidant by two different reaction schemes. In one procedure (method A), the residual cerium (IV) is reacted with a fixed concentration of ferroin and the increase in absorbance is measured at 510 nm. The second approach (method B) involves the reduction of the unreacted cerium (IV) with a fixed quantity of iron (II), and the resulting iron (III) is complexed with thiocyanate and the absorbance measured at 470 nm. In both methods, the amount of cerium (IV) reacted corresponds to SMT concentration. The experimental conditions for both methods were optimized. In method A, the absorbance is found to increase linearly with SMT concentration (r = 0.9995) whereas in method B, the same decreased (r = -0.9943). The systems obey Beer's law for 0.6-7.5 and 0.5-5.0 µg mL-1 for method A and method B, respectively. The calculated molar absorptivity values are 2.7 X 10(4) and 1.06 X 10(5) Lmol-1 cm-1, respectively; and the corresponding sandel sensitivity values are 0.0153 and 0.0039µg cm-2, respectively. The limit of detection (LOD) and quantification (LOQ) are reported for both methods. Intra-day and inter-day precision, and accuracy of the methods were established as per the current ICH guidelines. The methods were successfully applied to the determination of SMT in tablets and the results were statistically compared with those of the reference method by applying the Student's t-test and F-test. No interference was observed from the common excipients added to tablets. The accuracy and validity of the methods were further ascertained by performing recovery experiments via standard addition procedure.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A direct, extraction-free spectrophotometric method has been developed for the determination of acebutolol hydrochloride (ABH) in pharmaceutical preparations. The method is based on ion-pair complex formation between the drug and two acidic dyes (sulphonaphthalein) namely bromocresol green (BCG) and bromothymol blue (BTB). Conformity to Beer's law enabled the assay of the drug in the range of 0.5-13.8 µg mL-1 with BCG and 1.8-15.9 µg mL-1 with BTB. Compared with a reference method, the results obtained were of equal accuracy and precision. In addition, these methods were also found to be specific for the analysis of acebutolol hydrochloride in the presence of excipients, which are co-formulated in the drug.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A simple spectrophotometric method for the determination of cefotaxime, ceftriaxone, cefadroxil and cephalexin with variamine blue is presented. The determination is based on the hydrolysis of β-lactam ring of cephalosporins with sodium hydroxide which subsequently reacts with iodate to liberate iodine in acidic medium. The liberated iodine oxidizes variamine blue to violet colored species of maximum absorption at 556 nm. The absorbance is measured within the pH range of 4.0-4.2. Beer's law is obeyed in the range of 0.5-5.8 µg mL-1, 0.2-7.0 µg mL-1, 0.2-5.0 µg mL-1 and 0.5-8.5 µg mL-1 for cefotaxime, ceftriaxone, cefadroxil and cephalexin respectively. The analytical parameters were optimized and the method is successfully applied for the determination of cefotaxime, ceftriaxone, cefadroxil and cephalexin in pharmaceuticals.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A spectrophotometric flow injection method for the determination of paracetamol in pharmaceutical formulations is proposed. The procedure was based on the oxidation of paracetamol by sodium hypochloride and the determination of the excess of this oxidant using o-tolidine dichloride as chromogenic reagent at 430 nm. The analytical curve was linear in the paracetamol concentration range from 8.50 x 10-6 to 2.51 x 10-4 mol L-1 with a detection limit of 5.0 x 10-6 mol L-1. The relative standard deviation was smaller than 1.2% for 1.20 x 10-4 mol L-1 paracetamol solution (n = 10). The results obtained for paracetamol in pharmaceutical formulations using the proposed flow injection method and those obtained using a USP Pharmacopoeia method are in agreement at the 95% confidence level.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A simple, rapid and sensitive spectrophotometric method has been developed for the determination of methyldopa in pharmaceutical formulations. The method is based on the reaction between tetrachloro-p-benzoquinone (p-chloranil) and methyldopa, accelerated by hydrogen peroxide (H2O2), producing a violet-red compound (λmax = 535 nm) at ambient temperature (25.0 ± 0.2 ºC). Experimental design methodologies were used to optimize the measurement conditions. Beer's law is obeyed in a concentration range from 2.10 x 10-4 to 2.48 x 10-3 mol L-1 (r = 0.9997). The limit of detection was 7.55 x 10-6 mol L-1 and the limit of quantification was 2.52 x 10-5 mol L-1. The intraday precision and interday precision were studied for 10 replicate analyses of 1.59 x 10-3 mol L-1 methyldopa solution and the respective coefficients of variation were 0.7 and 1.1 %. The proposed method was successfully applied to the determination of methyldopa in commercial brands of pharmaceuticals. No interferences were observed from the common excipients in the formulations. The results obtained by the proposed method were favorably compared with those given by the Brazilian Pharmacopoeia procedure at 95 % confidence level.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper, a new, simple and sensitive method for arsenic determination in soil is proposed. This is based on the reduction of silver (I) and iron (III) ions by arsine followed by a complexation reaction of iron (II) with the spectrophotometric reagent Br-PADAP 2-(5-bromo-2-pyridylazo)-5-di-ethylaminophenol. Arsenic determination with a Sandell's sensitivity of 3.1 10-4 cm-2, linear range from 0.1 µg ml-1 to 2.0 µg ml-1 (r560 = 0.9995), molar absorptivity of 2.45 10(5) l mol-1 cm-1 and a concentration detection limit of 1.4 ng ml-1 (3s) were obtained using a 10 ml sample volume. Selectivity was increased with the use of EDTA as a masking agent. The proposed method was applied for arsenic determination in the presence of several ions amounts in digested soil samples. The results revealed that antimony (III), mercury (II), germanium (IV), platinum (IV) interferes at all analyzed proportions. The interferences can be easily removed by the use of EDTA. Precision and accuracy obtained were satisfactory with a R.S.D. < 5 %. Recovery of arsenic in soil samples varied from 95.55 to 102.70 % with a mean of 99.63 %. These results demonstrated that the proposed method is applicable for arsenic analysis in different soil samples.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Highly sensitive and selective spectrophotometric methods (A and B) were developed for the determination of micro amounts of olanzapine (OLZ). Method A (direct method) is based on the oxidation of olanzapine with a known excess of iodine monochloride (ICl) in an acidic medium. Under the same condition, thymol blue was iodinated by unreacted ICl, and the absorbance of uniodinated thymol blue was measured at 536 nm. The decrease in ICl concentration is a measure of drug concentration. In method B (indirect method), oxidation of OLZ by a known excess of Ce(IV) in sulfuric acid medium followed by the reaction of unreacted Ce(IV) with leuco crystal violet (LCV) to crystal violet (CV), which is measured in an acetate buffer medium ( pH 4.9) at 580 nm. These methods obey the Beer's law in the concentration range of 0.2-1.6 µg mL-1 (method A) and 0.1-1.4 µg mL-1 (method B). The developed procedures have been successfully applied to the determination of OLZ in pure and in dosage forms. The results exhibit no interference from the presence of excipients. The reliability of the methods was established by parallel determination of OLZ against the reference method.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A simple analytical method for quantification of atenolol in pharmaceutical formulations by diffuse reflectance spectroscopy is described. The method is based on the reaction, on the filter paper surface, between the drug and p-chloranil producing a colored compound. The best reaction conditions were obtained with 20 µL of atenolol solution and 20 µL of p-chloranil. All reflectance measurements were carried out at 550 nm and the linear range was from 1.13x10-2 to 7.88x10-2 mol L-1 (r = 0.9992). The limit of detection was 2.80 x 10-3 mol L-1. The proposed method was successfully applied to analysis of different commercial brands of pharmaceutical formulations and the results obtained by the proposed method were in good agreement with those obtained using the British Pharmacopoeia method.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Two simple sensitive and reproducible spectrophotometric methods have been developed for the determination of metronidazole either in pure form or in their tablets. The proposed methods are based on the reduction of the nitro group to amino group of the drug. The reduction of metronidazole was carried out with zinc powder and 5 N hydrochloric acid at room temperature in methanol. The resulting amine was then subjected to a condensation reaction with aromatic aldehyde namely, vanillin and p-dimethyl amino benzaldehyde (PDAB) to yield yellow colored Schiff's bases. The formed Schiff's bases are quantified spectrophotometrically at their absorption maxima at 422 nm for vanillin and 494 nm for PDAB. Beer's law was obeyed in the concentration ranges 10 to 65 µg mL-1 and 5 to 40 µg mL-1 with a limit of detection (LOD) of 0.080 µg mL-1 and 0.090 µg mL-1 for vanillin and PDAB, respectively. The mean percentage recoveries were found to be 100.05 ± 0.37 and 99.01 ± 0.76 for the two methods respectively. The proposed methods were successfully applied to determine the metronidazole in their tablet formulations and the results compared favorably to that of reference methods. The proposed methods are recommended for quality control and routine analysis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Five flavanones and three chalcones were isolated from Campomanesia adamantium Berg. (Myrtaceae) leaves. The contents of these compounds were determined by HPLC. The phenolic contents were also determined. The monitoring of the antioxidant activity was carried out by inhibition of peroxidation using the linoleic acid system and radical-scavenging (DPPH). The plants were collected from 4 distinct cities of the Mato Grosso do Sul State, Brazil. The different samples exhibited a range of 4.67-232.35 mg/g chalcones and 15.62-50.71 mg/g flavanones and phenolic contents of the 7.24-21.19 mg/g gallic acid. All extracts showed high antioxidant activity with a wide range of the radical-scavenging (DPPH) from 52.0 to 92.2 % and inhibition oxidation of linoleic acid from 14.6 to 94.2%.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A direct spectrophotometric method for simultaneous determination of Co(II) and Ni(II), with diethanoldithiocarbamate (DEDC) as complexing agent, is proposed using the maximum absorption at 360 and 638 nm (Co(II)/DEDC) and 390 nm (Ni/DEDC). Adjusting the best metal/ligand ratio, supporting eletrolite, pH, and time of analysis, linear analytical curves from 1.0 10-6-4.0 10-4 for Co(II) in the presence of Ni 1.0 10-6-1.0 10-4 mol L-1 were observed. No further treatment or calculation processes have been necessary. Recoveries in different mixing ratios were of 99%. Interference of Fe(III), Cu(II), Zn(II) and Cd(II), and anions as NO3-, Cl-, ClO4-, citrate and phosphate has been evaluated. The method was applied to natural waters spiked with the cations.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A potentiometric titration method for the determination of minoxidil based on its redox reaction with K2Cr2O7 is described. The best results were observed using 1.00 x 10-3 mol L-1 K2Cr2O7 and 1.00 x 10-2 mol L-1 minoxidil solutions, and the minoxidil as titrant in 2.00 mol L-1 H2SO4 medium. The method was applied to commercial samples and compared with the results from a chromatographic procedure. Recoveries from 97.4 to 98.7 % were observed depending on the sample. Comparison with the chromatographic procedure reveled agreement within 90% confidence level.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A spectrophotometric flow injection method for the determination of Zn(II) in ophthalmic formulations was developed. In this work, Zn(II) ion was complexed with Alizarin red S in borate buffer solution (pH 9.0) and the chromophore produced was monitored at 520 nm. The analytical curve was linear in the Zn(II) concentration range from 6.05 x 10-6 to 1.50 x 10-4 mol L-1 with a detection limit of 3.60 x 10-6 mol L-1. Recoveries ranged from 96.3 to 105 % and a relative standard deviation of 1.2 % (n = 10) for 5.5x10-5 mol L-1 Zn(II) reference solution were obtained. The sampling rate was 60 h-1 and the results obtained of Zn(II) in ophthalmic products using this procedure are in close agreement with those obtained using a comparative spectrophotometric procedure at 95 % confidence level.