30 resultados para 1207


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Patients with upper aerodigestive tract (UAT) cancers often suffer from malnutrition and compromised functional ability. We compared clinical outcome with percutaneous endoscopic gastrostomy (PEG) tube feeding begun at two different time points. The records of 151 patients with UAT carcinomas were reviewed retrospectively. We included patients undergoing radical radiochemotherapy and PEG tube feeding. Subjects were evaluated before PEG insertion and at the end of the treatment. Patients (n=15, 100%) were divided into two groups according to the presence (group A) or absence (group B) of mucositis. Group A (51.7% of patients) received early PEG: before or within 2 wk of radiotherapy. Group B (48.3%) received delayed PEG: between 2 wk and 3 mo after the start of radiotherapy. Mean weight loss was 1.03 kg in group A vs. 4.0 kg in group B, P=0.004. Treatment interruptions were significantly (P=0.01) more common in group B. Early PEG placement at the beginning of radiochemotherapy in patients with UAT tumors maintains the patient's nutritional state and reduces treatment interruptions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND Drinking eight glasses of fluid or water each day is widely believed to improve health, but evidence is sparse and conflicting. We aimed to investigate the association between fluid consumption and long-term mortality and kidney function. METHODS We conducted a longitudinal analysis within a prospective, population-based cohort study of 3858 men and women aged 49 years or older residing in Australia. Daily fluid intake from food and beverages not including water was measured using a food frequency questionnaire. We did multivariable adjusted Cox proportional hazard models for all-cause and cardiovascular mortality and a boot-strapping procedure for estimated glomerular filtration rate (eGFR). RESULTS Upper and lower quartiles of daily fluid intake corresponded to >3 L and <2 L, respectively. During a median follow-up of 13.1 years (total 43 093 years at risk), 1127 deaths (26.1 per 1000 years at risk) including 580 cardiovascular deaths (13.5 per 1000 years at risk) occurred. Daily fluid intake (per 250 mL increase) was not associated with all-cause [adjusted hazard ratio (HR) 0.99 (95% CI 0.98-1.01)] or cardiovascular mortality [HR 0.98 (95% CI 0.95-1.01)]. Overall, eGFR reduced by 2.2 mL/min per 1.73 m(2) (SD 10.9) in the 1207 (31%) participants who had repeat creatinine measurements and this was not associated with fluid intake [adjusted regression coefficient 0.06 mL/min/1.73 m(2) per 250 mL increase (95% CI -0.03 to 0.14)]. CONCLUSIONS Fluid intake from food and beverages excluding water is not associated with improved kidney function or reduced mortality.

Relevância:

10.00% 10.00%

Publicador:

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The T2K long-baseline neutrino oscillation experiment in Japan needs precise predictions of the initial neutrino flux. The highest precision can be reached based on detailed measurements of hadron emission from the same target as used by T2K exposed to a proton beam of the same kinetic energy of 30 GeV. The corresponding data were recorded in 2007-2010 by the NA61/SHINE experiment at the CERN SPS using a replica of the T2K graphite target. In this paper details of the experiment, data taking, data analysis method and results from the 2007 pilot run are presented. Furthermore, the application of the NA61/SHINE measurements to the predictions of the T2K initial neutrino flux is described and discussed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND AND AIMS Limited data from large cohorts are available on tumor necrosis factor (TNF) antagonists (infliximab, adalimumab, certolizumab pegol) switch over time. We aimed to evaluate the prevalence of switching from one TNF antagonist to another and to identify associated risk factors. METHODS Data from the Swiss Inflammatory Bowel Diseases Cohort Study (SIBDCS) were analyzed. RESULTS Of 1731 patients included into the SIBDCS (956 with Crohn's disease [CD] and 775 with ulcerative colitis [UC]), 347 CD patients (36.3%) and 129 UC patients (16.6%) were treated with at least one TNF antagonist. A total of 53/347 (15.3%) CD patients (median disease duration 9 years) and 20/129 (15.5%) of UC patients (median disease duration 7 years) needed to switch to a second and/or a third TNF antagonist, respectively. Median treatment duration was longest for the first TNF antagonist used (CD 25 months; UC 14 months), followed by the second (CD 13 months; UC 4 months) and third TNF antagonist (CD 11 months; UC 15 months). Primary nonresponse, loss of response and side effects were the major reasons to stop and/or switch TNF antagonist therapy. A low body mass index, a short diagnostic delay and extraintestinal manifestations at inclusion were identified as risk factors for a switch of the first used TNF antagonist within 24 months of its use in CD patients. CONCLUSION Switching of the TNF antagonist over time is a common issue. The median treatment duration with a specific TNF antagonist is diminishing with an increasing number of TNF antagonists being used.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

cpa-DNA monomers containing the bases adenine and thymine have been synthesized starting from the known compound 1 in 12 steps. Partially and fully modified cpa-thymidine and cpa-adenosine containing oligodeoxynucleotides were synthesized by standard oligonucleotide chemistry. Fully modified homo-cpa-A sequences lead to duplex destabilization by -1.4 degrees C/mod. relative to DNA. As its congener bca-DNA, cpa-DNA prefers left-handed duplex formation where possible

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We tested the assumption that ego depletion would affect the sprint start in a sample of N = 38 athletes without track and field experience in an experiment by applying a mixed between- (depletion vs. non-depletion) within- (T1: before manipulation of ego depletion vs. T2: after manipulation of ego depletion) subjects design. We assumed that ego depletion would increase the possibility for a false start, as regulating the impulse to initiate the sprinting movement too soon before the starting signal requires self-control. In line with our assumption, we found a significant interaction as there was only a significant increase in the number of false starts from T1 to T2 for the depletion group while this was not the case for the non-depletion group. We conclude that ego depletion has a detrimental influence on the sprint start in athletes without track and field experience.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND Current reporting guidelines do not call for standardised declaration of follow-up completeness, although study validity depends on the representativeness of measured outcomes. The Follow-Up Index (FUI) describes follow-up completeness at a given study end date as ratio between the investigated and the potential follow-up period. The association between FUI and the accuracy of survival-estimates was investigated. METHODS FUI and Kaplan-Meier estimates were calculated twice for 1207 consecutive patients undergoing aortic repair during an 11-year period: in a scenario A the population's clinical routine follow-up data (available from a prospective registry) was analysed conventionally. For the control scenario B, an independent survey was completed at the predefined study end. To determine the relation between FUI and the accuracy of study findings, discrepancies between scenarios regarding FUI, follow-up duration and cumulative survival-estimates were evaluated using multivariate analyses. RESULTS Scenario A noted 89 deaths (7.4%) during a mean considered follow-up of 30±28months. Scenario B, although analysing the same study period, detected 304 deaths (25.2%, P<0.001) as it scrutinized the complete follow-up period (49±32months). FUI (0.57±0.35 versus 1.00±0, P<0.001) and cumulative survival estimates (78.7% versus 50.7%, P<0.001) differed significantly between scenarios, suggesting that incomplete follow-up information led to underestimation of mortality. Degree of follow-up completeness (i.e. FUI-quartiles and FUI-intervals) correlated directly with accuracy of study findings: underestimation of long-term mortality increased almost linearly by 30% with every 0.1 drop in FUI (adjusted HR 1.30; 95%-CI 1.24;1.36, P<0.001). CONCLUSION Follow-up completeness is a pre-requisite for reliable outcome assessment and should be declared systematically. FUI represents a simple measure suited as reporting standard. Evidence lacking such information must be challenged as potentially flawed by selection bias.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND Recent technical development allows the digital manufacturing of monolithic reconstructions with high-performance materials. For implant-supported crowns, the fixation requires an abutment design onto which the reconstruction can be bonded. PURPOSE The aim of this laboratory investigation was to analyze stiffness, strength, and failure modes of implant-supported, computer-assisted design and computer-aided manufacturing (CAD/CAM)-generated resin nano ceramic (RNC) crowns bonded to three different titanium abutments. MATERIALS AND METHODS Eighteen monolithic RNC crowns were produced and loaded in a universal testing machine under quasi-static condition according to DIN ISO 14801. With regard to the type of titanium abutment, three groups were defined: (1) prefabricated cementable standard; (2) CAD/CAM-constructed individualized; and (3) novel prefabricated bonding base. Stiffness and strength were measured and analyzed statistically with Wilcoxon rank sum test. Sections of the specimens were examined microscopically. RESULTS Stiffness demonstrated high stability for all specimens loaded in the physiological loading range with means and standard deviations of 1,579 ± 120 N/mm (group A), 1,733 ± 89 N/mm (group B), and 1,704 ± 162 N/mm (group C). Mean strength of the novel prefabricated bonding base (group C) was 17% lower than of the two other groups. Plastic deformations were detectable for all implant-abutment crown connections. CONCLUSIONS Monolithic implant crowns made of RNC seem to represent a feasible and stable prosthetic construction under laboratory testing conditions with strength higher than the average occlusal force, independent of the different abutment designs used in this investigation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Automated tissue characterization is one of the most crucial components of a computer aided diagnosis (CAD) system for interstitial lung diseases (ILDs). Although much research has been conducted in this field, the problem remains challenging. Deep learning techniques have recently achieved impressive results in a variety of computer vision problems, raising expectations that they might be applied in other domains, such as medical image analysis. In this paper, we propose and evaluate a convolutional neural network (CNN), designed for the classification of ILD patterns. The proposed network consists of 5 convolutional layers with 2×2 kernels and LeakyReLU activations, followed by average pooling with size equal to the size of the final feature maps and three dense layers. The last dense layer has 7 outputs, equivalent to the classes considered: healthy, ground glass opacity (GGO), micronodules, consolidation, reticulation, honeycombing and a combination of GGO/reticulation. To train and evaluate the CNN, we used a dataset of 14696 image patches, derived by 120 CT scans from different scanners and hospitals. To the best of our knowledge, this is the first deep CNN designed for the specific problem. A comparative analysis proved the effectiveness of the proposed CNN against previous methods in a challenging dataset. The classification performance (~85.5%) demonstrated the potential of CNNs in analyzing lung patterns. Future work includes, extending the CNN to three-dimensional data provided by CT volume scans and integrating the proposed method into a CAD system that aims to provide differential diagnosis for ILDs as a supportive tool for radiologists.