9 resultados para liquid flow monitoring

em ArchiMeD - Elektronische Publikationen der Universität Mainz - Alemanha


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Understanding liquid flow at the vicinity of solid surfaces is crucial to the developmentrnof technologies to reduce drag. One possibility to infer flow properties at the liquid-solid interface is to compare the experimental results to solutions of the Navier-Stokes equations assuming the no-slip boundary condition (BC) or the slip BC. There is no consensus in the literature about which BC should be used to model the flow of aqueous solutions over hydrophilic surfaces. Here, the colloidal probe technique is used to systematically address this issue, measuring forces acting during drainage of water over a surface. Results show that experimental variables, especially the cantilever spring constant, lead to the discrepancy observed in the literature. Two different parameters, calculated from experimental variables, could be used to separate the data obtained in this work and those reported in the literature in two groups: one explained with the no-slip BC, and another with the slip BC. The observed residual slippage is a function of instrumental variables, showing a trend incompatible with the available physical justifications. As a result, the no-slip is the more appropriate BC. The parameters can be used to avoid situations where the no-slip BC is not satisfied.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Die pneumatische Zerstäubung ist die häufigste Methode der Probenzuführung von Flüssigkeiten in der Plasmaspektrometrie. Trotz der bekannten Limitierungen dieser Systeme, wie die hohen Probenverluste, finden diese Zerstäuber aufgrund ihrer guten Robustheit eine breite Anwendung. Die flussratenabhängige Aerosolcharakteristik und pumpenbasierte Signalschwankungen limitieren bisher Weiterentwicklungen. Diese Probleme werden umso gravierender, je weiter die notwendige Miniaturisierung dieser Systeme fortschreitet. Der neuartige Ansatz dieser Arbeit basiert auf dem Einsatz modifizierter Inkjet-Druckerpatronen für die Dosierung von pL-Tropfen. Ein selbst entwickelter Mikrokontroller ermöglicht den Betrieb von matrixkodierten Patronen des Typs HP45 mit vollem Zugriff auf alle essentiellen Betriebsparameter. Durch die neuartige Aerosoltransportkammer gelang die effiziente Kopplung des Tropfenerzeugungssystems an ein ICP-MS. Das so aufgebaute drop-on-demand-System (DOD) zeigt im Vergleich zu herkömmlichen und miniaturisierten Zerstäubern eine deutlich gesteigerte Empfindlichkeit (8 - 18x, elementabhängig) bei leicht erhöhtem, aber im Grunde vergleichbarem Signalrauschen. Darüber hinaus ist die Flexibilität durch die große Zahl an Freiheitsgraden des Systems überragend. So ist die Flussrate über einen großen Bereich variabel (5 nL - 12,5 µL min-1), ohne dabei die primäre Aerosolcharakteristik zu beeinflussen, welche vom Nutzer durch Wahl der elektrischen Parameter bestimmt wird. Das entwickelte Probenzuführungssystem ist verglichen mit dem pneumatischen Referenzsystem weniger anfällig gegenüber Matrixeffekten beim Einsatz von realen Proben mit hohen Anteilen gelöster Substanzen. So gelingt die richtige Quantifizierung von fünf Metallen im Spurenkonzentrationsbereich (Li, Sr, Mo, Sb und Cs) in nur 12 µL Urin-Referenzmaterial mittels externer Kalibrierung ohne Matrixanpassung. Wohingegen beim pneumatischen Referenzsystem die aufwändigere Standardadditionsmethode sowie über 250 µL Probenvolumen für eine akkurate Bestimmung der Analyten nötig sind. Darüber hinaus wird basierend auf der Dosierfrequenz eines dualen DOD-Systems eine neuartige Kalibrierstrategie vorgestellt. Bei diesem Ansatz werden nur eine Standard- und eine Blindlösung anstelle einer Reihe unterschiedlich konzentrierter Standards benötigt, um eine lineare Kalibrierfunktion zu erzeugen. Zusätzlich wurde mittels selbst entwickelter, zeitlich aufgelöster ICP-MS umfangreiche Rauschspektren aufgenommen. Aus diesen gelang die Ermittlung der Ursache des erhöhten Signalrauschens des DOD, welches maßgeblich durch das zeitlich nicht äquidistante Eintreffen der Tropfen am Detektor verursacht wird. Diese Messtechnik erlaubt auch die Detektion einzeln zugeführter Tropfen, wodurch ein Vergleich der Volumenverteilung der mittels ICP-MS detektierten, gegenüber den generierten und auf optischem Wege charakterisierten Tropfen möglich wurde. Dieses Werkzeug ist für diagnostische Untersuchungen äußerst hilfreich. So konnte aus diesen Studien neben der Aufklärung von Aerosoltransportprozessen die Transporteffizienz des DOD ermittelt werden, welche bis zu 94 Vol.-% beträgt.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Therapeutisches Drug Monitoring (TDM) wird zur individuellen Dosiseinstellung genutzt, um die Effizienz der Medikamentenwirkung zu steigern und das Auftreten von Nebenwirkungen zu senken. Für das TDM von Antipsychotika und Antidepressiva besteht allerdings das Problem, dass es mehr als 50 Medikamente gibt. Ein TDM-Labor muss dementsprechend über 50 verschiedene Wirkstoffe und zusätzlich aktive Metaboliten messen. Mit der Flüssigchromatographie (LC oder HPLC) ist die Analyse vieler unterschiedlicher Medikamente möglich. LC mit Säulenschaltung erlaubt eine Automatisierung. Dabei wird Blutserum oder -plasma mit oder ohne vorherige Proteinfällung auf eine Vorsäule aufgetragen. Nach Auswaschen von störenden Matrixbestandteilen werden die Medikamente auf einer nachgeschalteten analytischen Säule getrennt und über Ultraviolettspektroskopie (UV) oder Massenspektrometrie (MS) detektiert. Ziel dieser Arbeit war es, LC-Methoden zu entwickeln, die die Messung möglichst vieler Antipsychotika und Antidepressiva erlaubt und die für die TDM-Routine geeignet ist. Eine mit C8-modifiziertem Kieselgel gefüllte Säule (20 µm 10x4.0 mm I.D.) erwies sich in Vorexperimenten als optimal geeignet bezüglich Extraktionsverhalten, Regenerierbarkeit und Stabilität. Mit einer ersten HPLC-UV-Methode mit Säulenschaltung konnten 20 verschiedene Psychopharmaka einschließlich ihrer Metabolite, also insgesamt 30 verschiedene Substanzen quantitativ erfasst werden. Die Analysenzeit betrug 30 Minuten. Die Vorsäule erlaubte 150 Injektionen, die analytische Säule konnte mit mehr als 300 Plasmainjektionen belastet werden. Abhängig vom Analyten, musste allerdings das Injektionsvolumen, die Flussrate oder die Detektionswellenlänge verändert werden. Die Methode war daher für eine Routineanwendung nur eingeschränkt geeignet. Mit einer zweiten HPLC-UV-Methode konnten 43 verschiedene Antipsychotika und Antidepressiva inklusive Metaboliten nachgewiesen werden. Nach Vorreinigung über C8-Material (10 µm, 10x4 mm I.D.) erfolgte die Trennung auf Hypersil ODS (5 µm Partikelgröße) in der analytischen Säule (250x4.6 mm I.D.) mit 37.5% Acetonitril im analytischen Eluenten. Die optimale Flussrate war 1.5 ml/min und die Detektionswellenlänge 254 nm. In einer Einzelprobe, konnten mit dieser Methode 7 bis 8 unterschiedliche Substanzen gemessen werden. Für die Antipsychotika Clozapin, Olanzapin, Perazin, Quetiapin und Ziprasidon wurde die Methode validiert. Der Variationskoeffizient (VK%) für die Impräzision lag zwischen 0.2 und 6.1%. Im erforderlichen Messbereich war die Methode linear (Korrelationskoeffizienten, R2 zwischen 0.9765 und 0.9816). Die absolute und analytische Wiederfindung lagen zwischen 98 und 118 %. Die für das TDM erforderlichen unteren Nachweisgrenzen wurden erreicht. Für Olanzapin betrug sie 5 ng/ml. Die Methode wurde an Patienten für das TDM getestet. Sie erwies sich für das TDM als sehr gut geeignet. Nach retrospektiver Auswertung von Patientendaten konnte erstmalig ein möglicher therapeutischer Bereich für Quetiapin (40-170 ng/ml) und Ziprasidon (40-130 ng/ml) formuliert werden. Mit einem Massenspektrometer als Detektor war die Messung von acht Neuroleptika und ihren Metaboliten möglich. 12 Substanzen konnten in einem Lauf bestimmt werden: Amisulprid, Clozapin, N-Desmethylclozapin, Clozapin-N-oxid, Haloperidol, Risperidon, 9-Hydroxyrisperidon, Olanzapin, Perazin, N-Desmethylperazin, Quetiapin und Ziprasidon. Nach Vorreinigung mit C8-Material (20 µm 10x4.0 mm I.D.) erfolgte die Trennung auf Synergi MAX-RP C12 (4 µm 150 x 4.6 mm). Die Validierung der HPLC-MS-Methode belegten einen linearen Zusammenhang zwischen Konzentration und Detektorsignal (R2= 0,9974 bis 0.9999). Die Impräzision lag zwischen 0.84 bis 9.78%. Die für das TDM erforderlichen unteren Nachweisgrenzen wurden erreicht. Es gab keine Hinweise auf das Auftreten von Ion Suppression durch Matrixbestandteile. Die absolute und analytische Wiederfindung lag zwischen 89 und 107 %. Es zeigte sich, dass die HPLC-MS-Methode ohne Modifikation erweitert werden kann und anscheinend mehr als 30 verschiedene Psychopharmaka erfasst werden können. Mit den entwickelten flüssigchromatographischen Methoden stehen neue Verfahren für das TDM von Antipsychotika und Antidepressiva zur Verfügung, die es erlauben, mit einer Methode verschiedene Psychopharmaka und ihre aktiven Metabolite zu messen. Damit kann die Behandlung psychiatrischer Patienten insbesondere mit Antipsychotika verbessert werden.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Therapeutisches Drug Monitoring (TDM) umfasst die Messung von Medikamentenspiegeln im Blut und stellt die Ergebnisse in Zusammenhang mit dem klinischen Erscheinungsbild der Patienten. Dabei wird angenommen, dass die Konzentrationen im Blut besser mit der Wirkung korrelieren als die Dosis. Dies gilt auch für Antidepressiva. Voraussetzung für eine Therapiesteuerung durch TDM ist die Verfügbarkeit valider Messmethoden im Labor und die korrekte Anwendung des Verfahrens in der Klinik. Ziel dieser Arbeit war es, den Einsatz von TDM für die Depressionsbehandlung zu analysieren und zu verbessern. Im ersten Schritt wurde für das neu zugelassene Antidepressivum Duloxetin eine hochleistungsflüssig-chromatographische (HPLC) Methode mit Säulenschaltung und spektrophotometrischer Detektion etabliert und an Patienten für TDM angewandt. Durch Analyse von 280 Patientenproben wurde herausgefunden, dass Duloxetin-Konzentrationen von 60 bis 120 ng/ml mit gutem klinischen Ansprechen und einem geringen Risiko für Nebenwirkungen einhergingen. Bezüglich seines Interaktionspotentials erwies sich Duloxetin im Vergleich zu anderen Antidepressiva als schwacher Inhibitor des Cytochrom P450 (CYP) Isoenzyms 2D6. Es gab keinen Hinweis auf eine klinische Relevanz. Im zweiten Schritt sollte eine Methode entwickelt werden, mit der möglichst viele unterschiedliche Antidepressiva einschließlich deren Metaboliten messbar sind. Dazu wurde eine flüssigchromatographische Methode (HPLC) mit Ultraviolettspektroskopie (UV) entwickelt, mit der die quantitative Analyse von zehn antidepressiven und zusätzlich zwei antipsychotischen Substanzen innerhalb von 25 Minuten mit ausreichender Präzision und Richtigkeit (beide über 85%) und Sensitivität erlaubte. Durch Säulenschaltung war eine automatisierte Analyse von Blutplasma oder –serum möglich. Störende Matrixbestandteile konnten auf einer Vorsäule ohne vorherige Probenaufbereitung abgetrennt werden. Das kosten- und zeiteffektive Verfahren war eine deutliche Verbesserung für die Bewältigung von Proben im Laboralltag und damit für das TDM von Antidepressiva. Durch Analyse des klinischen Einsatzes von TDM wurden eine Reihe von Anwendungsfehlern identifiziert. Es wurde deshalb versucht, die klinische Anwendung des TDM von Antidepressiva durch die Umstellung von einer weitgehend händischen Dokumentation auf eine elektronische Bearbeitungsweise zu verbessern. Im Rahmen der Arbeit wurde untersucht, welchen Effekt man mit dieser Intervention erzielen konnte. Dazu wurde eine Labor-EDV eingeführt, mit der der Prozess vom Probeneingang bis zur Mitteilung der Messergebnisse auf die Stationen elektronisch erfolgte und die Anwendung von TDM vor und nach der Umstellung untersucht. Die Umstellung fand bei den behandelnden Ärzten gute Akzeptanz. Die Labor-EDV erlaubte eine kumulative Befundabfrage und eine Darstellung des Behandlungsverlaufs jedes einzelnen Patienten inklusive vorhergehender Klinikaufenthalte. Auf die Qualität der Anwendung von TDM hatte die Implementierung des Systems jedoch nur einen geringen Einfluss. Viele Anforderungen waren vor und nach der Einführung der EDV unverändert fehlerhaft, z.B. wurden häufig Messungen vor Erreichen des Steady State angefordert. Die Geschwindigkeit der Bearbeitung der Proben war im Vergleich zur vorher händischen Ausführung unverändert, ebenso die Qualität der Analysen bezüglich Richtigkeit und Präzision. Ausgesprochene Empfehlungen hinsichtlich der Dosierungsstrategie der angeforderten Substanzen wurden häufig nicht beachtet. Verkürzt wurde allerdings die mittlere Latenz, mit der eine Dosisanpassung nach Mitteilung des Laborbefundes erfolgte. Insgesamt ist es mit dieser Arbeit gelungen, einen Beitrag zur Verbesserung des Therapeutischen Drug Monitoring von Antidepressiva zu liefern. In der klinischen Anwendung sind allerdings Interventionen notwendig, um Anwendungsfehler beim TDM von Antidepressiva zu minimieren.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Five different methods were critically examined to characterize the pore structure of the silica monoliths. The mesopore characterization was performed using: a) the classical BJH method of nitrogen sorption data, which showed overestimated values in the mesopore distribution and was improved by using the NLDFT method, b) the ISEC method implementing the PPM and PNM models, which were especially developed for monolithic silicas, that contrary to the particulate supports, demonstrate the two inflection points in the ISEC curve, enabling the calculation of pore connectivity, a measure for the mass transfer kinetics in the mesopore network, c) the mercury porosimetry using a new recommended mercury contact angle values. rnThe results of the characterization of mesopores of monolithic silica columns by the three methods indicated that all methods were useful with respect to the pore size distribution by volume, but only the ISEC method with implemented PPM and PNM models gave the average pore size and distribution based on the number average and the pore connectivity values.rnThe characterization of the flow-through pore was performed by two different methods: a) the mercury porosimetry, which was used not only for average flow-through pore value estimation, but also the assessment of entrapment. It was found that the mass transfer from the flow-through pores to mesopores was not hindered in case of small sized flow-through pores with a narrow distribution, b) the liquid penetration where the average flow-through pore values were obtained via existing equations and improved by the additional methods developed according to Hagen-Poiseuille rules. The result was that not the flow-through pore size influences the column bock pressure, but the surface area to volume ratio of silica skeleton is most decisive. Thus the monolith with lowest ratio values will be the most permeable. rnThe flow-through pore characterization results obtained by mercury porosimetry and liquid permeability were compared with the ones from imaging and image analysis. All named methods enable a reliable characterization of the flow-through pore diameters for the monolithic silica columns, but special care should be taken about the chosen theoretical model.rnThe measured pore characterization parameters were then linked with the mass transfer properties of monolithic silica columns. As indicated by the ISEC results, no restrictions in mass transfer resistance were noticed in mesopores due to their high connectivity. The mercury porosimetry results also gave evidence that no restrictions occur for mass transfer from flow-through pores to mesopores in the small scaled silica monoliths with narrow distribution. rnThe prediction of the optimum regimes of the pore structural parameters for the given target parameters in HPLC separations was performed. It was found that a low mass transfer resistance in the mesopore volume is achieved when the nominal diameter of the number average size distribution of the mesopores is appr. an order of magnitude larger that the molecular radius of the analyte. The effective diffusion coefficient of an analyte molecule in the mesopore volume is strongly dependent on the value of the nominal pore diameter of the number averaged pore size distribution. The mesopore size has to be adapted to the molecular size of the analyte, in particular for peptides and proteins. rnThe study on flow-through pores of silica monoliths demonstrated that the surface to volume of the skeletons ratio and external porosity are decisive for the column efficiency. The latter is independent from the flow-through pore diameter. The flow-through pore characteristics by direct and indirect approaches were assessed and theoretical column efficiency curves were derived. The study showed that next to the surface to volume ratio, the total porosity and its distribution of the flow-through pores and mesopores have a substantial effect on the column plate number, especially as the extent of adsorption increases. The column efficiency is increasing with decreasing flow through pore diameter, decreasing with external porosity, and increasing with total porosity. Though this tendency has a limit due to heterogeneity of the studied monolithic samples. We found that the maximum efficiency of the studied monolithic research columns could be reached at a skeleton diameter of ~ 0.5 µm. Furthermore when the intention is to maximize the column efficiency, more homogeneous monoliths should be prepared.rn

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Der Erfolg einer Schizophrenie-Behandlung ist zum größten Teil abhängig vom Ansprechen des Patienten auf seine antipsychotische Medikation. Welches Medikament und welche Dosis bei einem individuellen Patienten wirksam sind, kann derzeit erst nach mehrwöchiger Behandlung beurteilt werden. Ein Grund für variierendes Therapieansprechen sind variable Plasmakonzentrationen der Antipsychotika. Ziel dieser Arbeit war es, zu untersuchen, in wieweit der Therapieerfolg zu einem frühen Zeitpunkt der Behandlung durch objektive Symptomerfassung vorhersagbar ist und welche Faktoren die hohe Variabilität der Antipsychotikaspiegel im Blut beeinflussen. rnEine 18-monatige naturalistische klinische Studie an schizophrenen Patienten wurde durchgeführt, um folgende Fragen zu beantworten: Kann man das Therapieansprechen prädizieren und welche Instrumente sind dafür geeignet? Die Psychopathologie wurde anhand zweier Messskalen (Brief Psychiatric Rating Scale, BPRS und Clinical Global Impressions, CGI) wöchentlich ermittelt, um die Besserung der Krankheitssymptome im Verlauf von 8 Wochen zu bewerten. Therapiebegleitend wurden noch die Serum-Konzentrationen der Antipsychotika gemessen. Objektive Symptomerfassung durch BPRS oder CGI waren als Messinstrumente geeignet, Therapieansprechen vorherzusagen. Bezogen auf den Behandlungsbeginn war eine Verminderung der Symptome hoch prädiktiv für späteres Therapieversagen oder -ansprechen. Eine Verminderung um mehr als 36,5% auf der BPRS Skala in Woche 2 wurde als signifikanter Schwellenwert für Nichtansprechen ermittelt. Patienten, deren Symptombesserung unterhalb des Schwellenwertes lag, hatten eine 11,2-fach höhere Wahrscheinlichkeit, am Ende der Studie nicht auf ihre medikamentöse Therapie anzusprechen als die Patienten, die sich um mindestens 36,5% verbesserten. Andere Faktoren, wie Alter, Geschlecht, Dauer der Erkrankung oder Anzahl der stationären Aufenthalte hatten keinen Einfluss auf die Prädiktion des Therapieansprechens. Therapeutische Antipsychotika-Spiegel übten einen positiven Einfluss auf die Ansprechrate aus. Bei Patienten mit therapeutischen Spiegeln war das Ansprechen rascher und die Ansprechrate größer als unter denjenigen deren Spiegel außerhalb der therapeutisch üblichen Bereiche lag. rnEine wichtige Voraussetzung für den Einsatz von TDM ist das Vorhandensein einer präzisen, reproduzierbaren, zeit- und kostensparenden analytischen Methode zur quantitativen Bestimmung der untersuchten Substanzen. Die Entwicklung und Validierung einer solchen geeigneten Methode wurde für den Nachweis von Haloperidol vorgenommen. Eine HPLC-Methode mit Säulenschaltung erwies sich für TDM geeignet. rnBasierend auf den Ergebnissen der eigenen klinischen Studie zur Response Prädiktion wurde untersucht, welche Faktoren die Variabilität der Pharmakokinetik von Antipsychotika beeinflussen. Die Variabilität der Pharmakokinetik ist ein Grund für fehlendes oder unzureichendes Ansprechen. Es wurde zum einen der Einfluss der galenischen Formulierung auf die Freisetzung und zum anderen der Einfluss von entzündlichen Prozessen auf die Metabolisierung eines Antipsychotikums untersucht. Dazu wurden Patientendaten retrospektiv ausgewertet.rnDie Analyse von 247 Serumspiegeln von Patienten, die mit Paliperidon in OROS®Formulierung, einer neu eingeführten Retardform, behandelt wurden, zeigte, dass die intraindividuelle Variabilität der Talspiegel (Vk) von Paliperidon 35% betrug. Er war damit vergleichbar wie für nicht retardiertes Risperidon 32% (p=n.s.). Die Retardierung hatte demnach keinen Varianz mindernden Effekt auf die Talspiegel des Antipsychotikums. Der Wirkstoff-Konzentrations-Bereich lag bei 21-55 ng/ml und entsprach ebenfalls nahezu dem therapeutischen Bereich von Risperidon (20-60 ng/ml). rnEntzündliche Prozesse können die Metabolisierung von Medikamenten verändern. Dies wurde bisher für Medikamente nachgewiesen, die über CYP1A2 abgebaut werden. Durch die eigene Analyse von 84 Patienten-Serumspiegeln konnte festgestellt werden, dass die Metabolisierung von Quetiapin während eines entzündlichen Prozesses beeinträchtigt war, wahrscheinlich durch Hemmung von CYP3A4. Dies sprach dafür, dass auch Wirkstoffe, die über CYP3A4 abgebaut werden, während eines entzündlichen Prozesses im Körper in ihrer Pharmakokinetik beeinträchtigt sein können. Aus diesem Grund sollte während einer Infektion unter der Therapie mit Quetiapin besonders auf die Nebenwirkungen geachtet werden und der Serumspiegel sollte in dieser Zeit überwacht werden, um den Patienten vor eventuellen Nebenwirkungen oder sogar Intoxikationen zu schützen. rnDie Befunde dieser Arbeit zeigen, dass bei einer Behandlung schizophrener Patienten mit Antipsychotika die Messung der Psychopathologie zur Vorhersage des Therapieansprechens und die Messung der Blutspiegel zur Identifizierung von Faktoren, die die pharmakokinetische Variabilität bedingen, geeignet sind. Objektive Symptomerfassung und Therapeutisches Drug Monitoring sind demnach Instrumente, die für die Steuerung der antipsychotischen Pharmakotherapie genutzt werden sollten.rn

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Therapeutisches Drug Monitoring (TDM) findet Anwendung in der Therapie mit Immunosuppressiva, Antibiotika, antiretroviraler Medikation, Antikonvulsiva, Antidepressiva und auch Antipsychotika, um die Effizienz zu steigern und das Risiko von Intoxikationen zu reduzieren. Jedoch ist die Anwendung von TDM für Substanzen, die Einsatz finden in der Rückfallprophylaxe, der Substitution oder dem Entzug von Abhängigkeitserkrankungen nicht etabliert. Für diese Arbeit wurde im ersten Schritt eine sensitive Rating-Skala mit 22 Items entwickelt, mit Hilfe derer der theoretische Nutzen von TDM in der Pharmakotherapie von substanzbezogenen Abhängigkeitserkrankungen auf der Basis von pharmakologischen Eigenschaften der Medikamente und von Patientencharakteristika evaluiert wurde. Die vorgenommene Einschätzung zeigte für Bupropion, Buprenorphin, Disulfiram (oder einen Metaboliten), Methadon (chirale Bestimmung wenn möglich) und Naltrexon einen potentiellen Nutzen von TDM.rnFür die meisten Medikamente, die zur Behandlung von Abhängigkeitserkrankungen zugelassen sind, fehlen valide Messverfahren für TDM. Im Alltag werden überwiegend Drogen Screening-Tests in Form immunologischer Schnelltests angewendet. Für die Anwendung von TDM wurden in dieser Arbeit chromatographische Verfahren für die Bestimmung von Naltrexon und 6β-Naltrexol, Bupropion und Hydroxybupropion sowie R,S-Methadon und R,S-2-Ethyliden-1,5-dimethyl-3,3-diphenylpyrrolidin entwickelt, optimiert und validiert. Es handelt sich dabei HPLC-UV-Methoden mit Säulenschaltung sowie zur Bestimmung von Naltrexon und 6β-Naltrexol zusätzlich eine LC-MS/MS-Methode. Voraussetzung für die Interpretation der Plasmaspiegel ist im Wesentlichen die Kenntnis eines therapeutischen Bereichs. Für Naltrexon und seinen aktiven Metaboliten 6β-Naltrexol konnte eine signifikante Korrelation zwischen dem auftretenden Craving und der Summenkonzentration gefunden werden. Mittels Receiver-Operation-Characteristics-Kurven-Analyse wurde ein Schwellenwert von 16,6 ng/ml ermittelt, oberhalb dessen mit einem erhöhten Ansprechen gerechnet werden kann. Für Levomethadon wurde bezüglich der Detoxifikationsbehandlung ein Zusammenhang in der prozentualen Reduktion des Plasmaspiegels und den objektiven und subjektiven Entzugssymptomen gefunden. rnDoch nicht nur die Wirkstoffe, sondern auch das Patientenmerkmal substanzbezogene Abhängigkeit wurde charakterisiert, zum einen bezüglich pharmakokinetischer Besonderheiten, zum anderen in Hinsicht auf die Therapietreue (Adhärenz). Für Patienten mit komorbider Substanzabhängigkeit konnte eine verminderte Adhärenz unabhängig von der Hauptdiagnose gezeigt werden. Die Betrachtung des Einflusses von veränderten Leberwerten zeigt für komorbide Patienten eine hohe Korrelation mit dem Metabolisiererstatus, nicht aber für Patienten ohne Substanzabhängigkeit.rnÜbergeordnetes Ziel von TDM ist die Erhöhung der Therapiesicherheit und die Steigerung der Therapieeffizienz. Dies ist jedoch nur möglich, wenn TDM im klinischen Alltag integriert ist und korrekt eingesetzt wird. Obwohl es klare Evidenz für TDM von psychiatrischer Medikation gibt, ist die Diskrepanz zwischen Laborempfehlung und der klinischen Umsetzung hoch. Durch Intensivierung der interdisziplinären Zusammenarbeit zwischen Ärzten und Labor, der Entwicklung von interaktivem TDM (iTDM), konnte die Qualität der Anwendung von TDM verbessert und das Risiko von unerwünschten Arzneimittelwirkungen vermindert werden. rnInsgesamt konnte durch die eigenen Untersuchungen gezeigt werden, dass TDM für die medikamentöse Einstellung von Patienten mit Abhängigkeitserkrankung sinnvoll ist und dass optimales TDM eine interdisziplinäre Zusammenarbeit erfordert.rn

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Liquid crystalline elastomers (LCEs) are known to perform a reversible change of shape upon the phase transition from the semi-ordered liquid crystalline state to the chaotic isotropic state. This unique behavior of these “artificial muscles” arises from the self-organizing properties of liquid crystals (mesogens) in combination with the entropy-elasticity of the slightly crosslinked elastomer network. In this work, micrometer-sized LCE actuators are fabricated in a microfluidic setup. The microtubular shear flow provides for a uniform orientation of the mesogens during the crosslinking, a perquisite for obtaining actuating LCE samples. The scope of this work was to design different actuator geometries and to broaden the applicability of the microfluidic device for different types of liquid crystalline mesogens, ranging from side-chain to main-chain systems, as well as monomer and polymer precursors. For example, the thiol-ene “click” mechanism was used for the polymerization and crosslinking of main-chain LCE actuators. The main focus was, however, placed on acrylate monomers and polymers with LC side chains. A LC polymer precursor, comprising mesogenic and crosslinkable side-chains was synthesized. Used in combination with an LC monomer, the polymeric crosslinker promoted a stable LC phase, which allowed the mixture to be isothermally handled in the microfluidic reactor. If processed without the additional LC components, the polymer precursor yielded actuating fibers. A suitable co-flowing continuous phase facilitates the formation of a liquid jet and lowers the tendency for drop formation. By modification of the microfluidic device, it was further possible to prepare core-shell particles, comprised of an LCE shell and filled with an isotropic liquid. In analogy to the heart, a hollow muscle, the elastomer shell expels the inner liquid core upon its contraction. The feasibility of the core-shell particles as micropumps was demonstrated. In general, the synthesized LCE microactuators may be utilized as active components in micromechanical and lab-on-chip systems.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this thesis cholesteric films made of liquid crystalline cellulose derivatives with improved optical properties were prepared. The choice of the solvent, hydrogen bond influencing additives, the synthetic realization of a very high degree of substitution on the cellulosic polymer and the use of mechanical stirring at the upper concentration limit of the liquid crystalline range were the basis for an improved alignment of the applied cellulose tricarbamates. In combination with a tuned substrate treatment and film preparation method, cholesteric films were obtained, with optical properties that were theoretically predicted and only known from low molecular weight liquid crystals so far. Subsequent polymerization allowed a permanent fixing of the alignment and the fabrication of free standing and insensitive films.rnThe incorporation of inorganic nanorods into the cholesteric host material was mediated with tailored block copolymers, available via controlled radical polymerization methods. In addition to the shape match between the rodlike mesogens of the host and the nanorods it was possible to increase the miscibility of both materials. Nevertheless, the size of the nanorods, in comparison to the mesogens, in these densely packed liquid crystalline phases as well as their long equilibration times were the reasons for phase separation. Nanorods are, in principle, valuable substitutes for organics, but their utilization in cellulosic CLC was not to be combined with a high quality alignment of the cholesteric structure.rnA swelling process of polymerized films in a dye solution or dissolving dyes in non-polymerized CLC was used for incorporation of the organic chromophores. With the first method the CLC could be aligned and polymerized without any disturbance due to dye molecules. The optical properties of dye and CLC were matched, with regard to mirrorless lasing devices. The dye was optically excited and laser emission supported by the cholesteric cavity was obtained. The polarization and wavelength of the emitted radiation as well as its bandwidth, the obtained interference pattern and threshold behavior of the emission proofed the feedback mechanism that was not believed to be realizable in liquid crystalline polymers. rnUtilization of a microfluidic co-flow injection device enabled us to transfer the properties of cellulosic CLC from the planar film shape to spherical micrometer sized particles. The pure material yielded particles with distorted mesogen alignment similar to films prepared by capillary flow. Dilution of the CLC with a solvent that migrated into the carrier phase during particle preparation provided the basis for particles with well ordered areas. rnAlthough cellulose derivatives were known for their liquid crystalline behavior for decades and synthesized in mass production, their application as feedback material was affected by bad optical properties. In comparison to low molar mass compounds, the low degree of order in the CLC phase was the cause. With the improved material, defined lasing emission was shown and characterized. Derivatives of cellulose are desirable materials, because, as a renewable resource, they are available in large amounts for a low price and need only simple derivatization reactions. The fabrication of CLC films with tunable lasing emission, for which this thesis can provide a starting point, is in good agreement with today's requirements of modern technology and its miniaturization.rn