9 resultados para COUPLED-WAVE ANALYSIS
em ArchiMeD - Elektronische Publikationen der Universität Mainz - Alemanha
Resumo:
The systematic exploration of excited meson and baryon states was the central topic of the COMPASS physics program in the years 2008 and 2009 at the CERN facility. A hadron beam of 190 GeV/c particle momentum was impinging on a 40 cm long liquid hydrogen target to create excited states of beam particles by diffractive processes. The presented work is about the study of the process $K^- p rightarrow K^- pi^+ pi^- p_{recoil}$ where special emphasis is put on how kaons were distinguished from pions with the CEDAR detectors in the initial channel as well as with the RICH detector in the final states. At the end formed 270 000 events an invariant K pi pi mass distribution of overlapping resonances. In addition a detailed MC simulation study of 44 million decays in the range of 0.8 < m(K pi pi) [GeV/c^2] < 3.0 was performed and analysed for acceptance corrections.All information was combined into a mass independent partial wave analysis to observe resonances of individual particles. The main contribution was found in the JP = 0+, 1+, 2- and 2+ spin-parity states.
Resumo:
The quark model successfully describes all ground state bary-ons as members of $SU(N)$ flavour multiplets. For excited baryon states the situation is totally different. There are much less states found in the experiment than predicted in most theoretical calculations. This fact has been known for a long time as the 'missing resonance problem'. In addition, many states found in experiments are only poorly measured up to now. Therefore, further experimental efforts are needed to clarify the situation.rnrnAt mbox{COMPASS}, reactions of a $190uskgigaeVperclight$ hadron beam impinging on a liquid hydrogen target are investigated.rnThe hadron beam contains different species of particles ($pi$, $K$, $p$). To distinguish these particles, two Cherenkov detectors are used. In this thesis, a new method for the identification of particles from the detector information is developed. This method is based on statistical approaches and allows a better kaon identification efficiency with a similar purity compared to the method, which was used before.rnrnThe reaction $pprightarrow ppX$ with $X=(pi^0,~eta,~omega,~phi)$ is used to study different production mechanisms. A previous analysis of $omega$ and $phi$ mesons is extended to pseudoscalar mesons. As the resonance contributions in $peta$ are smaller than in $ppi^0$ a different behaviour of these two final states is expected as a function of kinematic variables. The investigation of these differences allows to study different production mechanisms and to estimate the size of the resonant contribution in the different channels.rnrnIn addition, the channel $pprightarrow ppX$ allows to study baryon resonances in the $pX$ system.rnIn the mbox{COMPASS} energy regime, the reaction is dominated by Pomeron exchange. As a Pomeron carries vacuum quantum numbers, no isospin is transferred between the target proton and the beam proton. Therefore, the $pX$ final state has isospin $textstylefrac{1}{2}$ and all baryon resonances in this channel are $N^ast$ baryons. This offers the opportunity to do spectroscopy without taking $Delta$ resonances into account. rnrnTo disentangle the contributions of different resonances a partial wave analysis (PWA) is used. Different resonances have different spin and parity $J^parity$, which results in different angular distributions of the decay particles. These angular distributions can be calculated from models and then be fitted to the data. From the fit the contributions of the single resonances as well as resonance parameters -- namely the mass and the width -- can be extracted. In this thesis, two different approaches for a partial wave analysis of the reaction $pprightarrow pppi^0$ are developed and tested.
Resumo:
Coupled-Cluster-Berechnungen von Parametern derKernspin-Resonanz-Spektroskopie Dissertationsschrift von Alexander A.Auer, Mainz 2002 Im Rahmen einer Studie der Berechnung von 13C-Verschiebungenwerdendie Einfluesse von Elektronenkorrelation, Basissatz,Gleichgewichtsgeometrie sowie Schwingungs- und Rotationseffekten separat betrachtet.Dabei zeigt sich, dass dieCoupled-Cluster-Singles-Doubles-Methode mitstoerungstheoretischer Behandlung der Dreifachanregungen(CCSD(T)) mit entsprechend grossen Basissaetzen bei Beruecksichtigung derNullpunktsschwingungseffekte Ergebnisse mit ca. 1 ppm Abweichung zum Experiment liefert. Eine Analyse der Elektronenkorrelationseffekte beiCoupled-Cluster- (CC-) Berechnungen von indirekten Spin-Spin-Kopplungskonstanten zeigt, dassCC-Methoden mit Hartree-Fock-Orbitalrelaxation zur Berechnung derKopplungskonstanten ungeeignet sind. Eine Loesung ist die Verwendung unrelaxierter CC-Methoden,in denendie HF-Orbitalrelaxation aus der Berechnung der gestoertenWellenfunktion ausgeschlossen wird. Full-Configuration-Interaction-Berechnungen fuer Borhydridzeigen,dass auf CC-Singles-Doubles-Niveau (CCSD) 94% und aufCC-Singles-Doubles-Triples-Niveau (CCSDT) 99% der Korrelationseffekte beschrieben werden. Weiterhin istdie Beruecksichtigung der Nullpunktsschwingung sowie die Wahl eines ausreichend grossen Basissatzes wichtig. Auf Grundlage der vorangegangenen Studien werden im letztenTeil zwei Beispiele zur Anwendung hochgenauer Berechnungen vonNMR-Parametern vorgestellt.Im Rahmen einer Studie der Spin-Spin-Kopplungskonstanten vonCyclopentan wird eine Karplus-Beziehungzwischen den Kopplungskonstanten und der Konformation desMolekuels aufgestellt, desweiteren werden die NMR-Parameter von Methylidinphosphanuntersucht.
Resumo:
An accurate and sensitive species-specific GC-ICP-IDMS (gas chromatography inductively coupled plasma isotope dilution mass spectrometry) method for the determination of trimethyllead and a multi-species-specific GC-ICP-IDMS method for the simultaneous determination of trimethyllead, methylmercury, and butyltins in biological and environmental samples were developed. They allow the determination of corresponding elemental species down to the low ng g-1 range. The developed synthesis scheme for the formation of isotopically labeled Me3206Pb+ can be used for future production of this spike. The novel extraction technique, stir bar sorptive extraction (SBSE), was applied for the first time in connection with species-specific isotope dilution GC-ICP-MS for the determination of trimethyllead, methylmercury and butyltins. The results were compared with liquid-liquid extraction. The developed methods were validated by the analysis of certified reference materials. The liquid-liquid extraction GC-ICP-IDMS method was applied to seafood samples purchased from a supermarket. The methylated lead fraction in these samples, correlated to total lead, varied in a broad range of 0.01-7.6 %. On the contrary, the fraction of methylmercury is much higher, normally in the range of 80-98 %. The highest methylmercury content of up to 12 µg g-1 has been determined in shark samples, an animal which is at the end of the marine food chain, whereas in other seafood samples a MeHg+ content of less than 0.2 µg g-1 was found. Butyltin species could only be determined in samples, where anthropogenic contaminations must be assumed. This explains the observed broad variation of the butylated tin fraction in the range of <0.3-49 % in different seafood samples. Because all isotope-labelled spike compounds, except trimethyllead, are commercially available, the developed multi-species-specific GC-ICP-IDMS method has a high potential in future for routine analysis.
Resumo:
Therapeutisches Drug Monitoring (TDM) wird zur individuellen Dosiseinstellung genutzt, um die Effizienz der Medikamentenwirkung zu steigern und das Auftreten von Nebenwirkungen zu senken. Für das TDM von Antipsychotika und Antidepressiva besteht allerdings das Problem, dass es mehr als 50 Medikamente gibt. Ein TDM-Labor muss dementsprechend über 50 verschiedene Wirkstoffe und zusätzlich aktive Metaboliten messen. Mit der Flüssigchromatographie (LC oder HPLC) ist die Analyse vieler unterschiedlicher Medikamente möglich. LC mit Säulenschaltung erlaubt eine Automatisierung. Dabei wird Blutserum oder -plasma mit oder ohne vorherige Proteinfällung auf eine Vorsäule aufgetragen. Nach Auswaschen von störenden Matrixbestandteilen werden die Medikamente auf einer nachgeschalteten analytischen Säule getrennt und über Ultraviolettspektroskopie (UV) oder Massenspektrometrie (MS) detektiert. Ziel dieser Arbeit war es, LC-Methoden zu entwickeln, die die Messung möglichst vieler Antipsychotika und Antidepressiva erlaubt und die für die TDM-Routine geeignet ist. Eine mit C8-modifiziertem Kieselgel gefüllte Säule (20 µm 10x4.0 mm I.D.) erwies sich in Vorexperimenten als optimal geeignet bezüglich Extraktionsverhalten, Regenerierbarkeit und Stabilität. Mit einer ersten HPLC-UV-Methode mit Säulenschaltung konnten 20 verschiedene Psychopharmaka einschließlich ihrer Metabolite, also insgesamt 30 verschiedene Substanzen quantitativ erfasst werden. Die Analysenzeit betrug 30 Minuten. Die Vorsäule erlaubte 150 Injektionen, die analytische Säule konnte mit mehr als 300 Plasmainjektionen belastet werden. Abhängig vom Analyten, musste allerdings das Injektionsvolumen, die Flussrate oder die Detektionswellenlänge verändert werden. Die Methode war daher für eine Routineanwendung nur eingeschränkt geeignet. Mit einer zweiten HPLC-UV-Methode konnten 43 verschiedene Antipsychotika und Antidepressiva inklusive Metaboliten nachgewiesen werden. Nach Vorreinigung über C8-Material (10 µm, 10x4 mm I.D.) erfolgte die Trennung auf Hypersil ODS (5 µm Partikelgröße) in der analytischen Säule (250x4.6 mm I.D.) mit 37.5% Acetonitril im analytischen Eluenten. Die optimale Flussrate war 1.5 ml/min und die Detektionswellenlänge 254 nm. In einer Einzelprobe, konnten mit dieser Methode 7 bis 8 unterschiedliche Substanzen gemessen werden. Für die Antipsychotika Clozapin, Olanzapin, Perazin, Quetiapin und Ziprasidon wurde die Methode validiert. Der Variationskoeffizient (VK%) für die Impräzision lag zwischen 0.2 und 6.1%. Im erforderlichen Messbereich war die Methode linear (Korrelationskoeffizienten, R2 zwischen 0.9765 und 0.9816). Die absolute und analytische Wiederfindung lagen zwischen 98 und 118 %. Die für das TDM erforderlichen unteren Nachweisgrenzen wurden erreicht. Für Olanzapin betrug sie 5 ng/ml. Die Methode wurde an Patienten für das TDM getestet. Sie erwies sich für das TDM als sehr gut geeignet. Nach retrospektiver Auswertung von Patientendaten konnte erstmalig ein möglicher therapeutischer Bereich für Quetiapin (40-170 ng/ml) und Ziprasidon (40-130 ng/ml) formuliert werden. Mit einem Massenspektrometer als Detektor war die Messung von acht Neuroleptika und ihren Metaboliten möglich. 12 Substanzen konnten in einem Lauf bestimmt werden: Amisulprid, Clozapin, N-Desmethylclozapin, Clozapin-N-oxid, Haloperidol, Risperidon, 9-Hydroxyrisperidon, Olanzapin, Perazin, N-Desmethylperazin, Quetiapin und Ziprasidon. Nach Vorreinigung mit C8-Material (20 µm 10x4.0 mm I.D.) erfolgte die Trennung auf Synergi MAX-RP C12 (4 µm 150 x 4.6 mm). Die Validierung der HPLC-MS-Methode belegten einen linearen Zusammenhang zwischen Konzentration und Detektorsignal (R2= 0,9974 bis 0.9999). Die Impräzision lag zwischen 0.84 bis 9.78%. Die für das TDM erforderlichen unteren Nachweisgrenzen wurden erreicht. Es gab keine Hinweise auf das Auftreten von Ion Suppression durch Matrixbestandteile. Die absolute und analytische Wiederfindung lag zwischen 89 und 107 %. Es zeigte sich, dass die HPLC-MS-Methode ohne Modifikation erweitert werden kann und anscheinend mehr als 30 verschiedene Psychopharmaka erfasst werden können. Mit den entwickelten flüssigchromatographischen Methoden stehen neue Verfahren für das TDM von Antipsychotika und Antidepressiva zur Verfügung, die es erlauben, mit einer Methode verschiedene Psychopharmaka und ihre aktiven Metabolite zu messen. Damit kann die Behandlung psychiatrischer Patienten insbesondere mit Antipsychotika verbessert werden.
Resumo:
“Plasmon” is a synonym for collective oscillations of the conduction electrons in a metal nanoparticle (excited by an incoming light wave), which cause strong optical responses like efficient light scattering. The scattering cross-section with respect to the light wavelength depends not only on material, size and shape of the nanoparticle, but also on the refractive index of the embedding medium. For this reason, plasmonic nanoparticles are interesting candidates for sensing applications. Here, two novel setups for rapid spectral investigations of single nanoparticles and different sensing experiments are presented.rnrnPrecisely, the novel setups are based on an optical microscope operated in darkfield modus. For the fast single particle spectroscopy (fastSPS) setup, the entrance pinhole of a coupled spectrometer is replaced by a liquid crystal device (LCD) acting as spatially addressable electronic shutter. This improvement allows the automatic and continuous investigation of several particles in parallel for the first time. The second novel setup (RotPOL) usesrna rotating wedge-shaped polarizer and encodes the full polarization information of each particle within one image, which reveals the symmetry of the particles and their plasmon modes. Both setups are used to observe nanoparticle growth in situ on a single-particle level to extract quantitative data on nanoparticle growth.rnrnUsing the fastSPS setup, I investigate the membrane coating of gold nanorods in aqueous solution and show unequivocally the subsequent detection of protein binding to the membrane. This binding process leads to a spectral shift of the particles resonance due to the higher refractive index of the protein compared to water. Hence, the nanosized addressable sensor platform allows for local analysis of protein interactions with biological membranes as a function of the lateral composition of phase separated membranes.rnrnThe sensitivity on changes in the environmental refractive index depends on the particles’ aspect ratio. On the basis of simulations and experiments, I could present the existence of an optimal aspect ratio range between 3 and 4 for gold nanorods for sensing applications. A further sensitivity increase can only be reached by chemical modifications of the gold nanorods. This can be achieved by synthesizing an additional porous gold cage around the nanorods, resulting in a plasmon sensitivity raise of up to 50 % for those “nanorattles” compared to gold nanorods with the same resonance wavelength. Another possibility isrnto coat the gold nanorods with a thin silver shell. This reduces the single particle’s resonance spectral linewidth about 30 %, which enlarges the resolution of the observable shift. rnrnThis silver coating evokes the interesting effect of reducing the ensemble plasmon linewidth by changing the relation connecting particle shape and plasmon resonance wavelength. This change, I term plasmonic focusing, leads to less variation of resonance wavelengths for the same particle size distribution, which I show experimentally and theoretically.rnrnIn a system of two coupled nanoparticles, the plasmon modes of the transversal and longitudinal axis depend on the refractive index of the environmental solution, but only the latter one is influenced by the interparticle distance. I show that monitoring both modes provides a self-calibrating system, where interparticle distance variations and changes of the environmental refractive index can be determined with high precision.
Resumo:
rnThis thesis is on the flavor problem of Randall Sundrum modelsrnand their strongly coupled dual theories. These models are particularly wellrnmotivated extensions of the Standard Model, because they simultaneously address rntherngauge hierarchy problem and the hierarchies in the quarkrnmasses and mixings. In order to put this into context, special attention is given to concepts underlying therntheories which can explain the hierarchy problem and the flavor structure of the Standard Model (SM). ThernAdS/CFTrnduality is introduced and its implications for the Randall Sundrum model withrnfermions in the bulk andrngeneral bulk gauge groups is investigated. It will be shown that the differentrnterms in the general 5D propagator of a bulk gauge field can be related tornthe corresponding diagrams of the strongly coupled dual, which allows for arndeeperrnunderstanding of the origin of flavor changing neutral currents generated by thernexchange of the Kaluza Klein excitations of these bulk fields.rnIn the numerical analysis, different observables which are sensitive torncorrections from therntree-levelrnexchange of these resonances will be presented on the basis of updatedrnexperimental data from the Tevatron and LHC experiments. This includesrnelectroweak precision observables, namely corrections to the S and Trnparameters followed by corrections to the Zbb vertex, flavor changingrnobservables with flavor changes at one vertex, viz. BR (Bd -> mu+mu-) and BR (Bs -> mu+mu-), and two vertices,rn viz. S_psiphi and |eps_K|, as well as bounds from direct detectionrnexperiments. rnThe analysis will show that all of these bounds can be brought in agreement withrna new physics scale Lambda_NP in the TeV range, except for the CPrnviolating quantity |eps_K|, which requires Lambda_NP= Ord(10) TeVrnin the absencernof fine-tuning. The numerous modifications of the Randall Sundrum modelrnin the literature, which try to attenuate this bound are reviewed andrncategorized.rnrnSubsequently, a novel solution to this flavor problem, based on an extendedrncolor gauge group in the bulk and its thorough implementation inrnthe RS model, will be presented, as well as an analysis of the observablesrnmentioned above in the extended model. This solution is especially motivatedrnfromrnthe point of view of the strongly coupled dual theory and the implications forrnstrongly coupled models of new physics, which do not possess a holographic dual,rnare examined.rnFinally, the top quark plays a special role in models with a geometric explanation ofrnflavor hierarchies and the predictions in the Randall-Sundrum model with andrnwithout the proposed extension for the forward-backward asymmetryrnA_FB^trnin top pair production are computed.
Resumo:
Aerosol particles are important actors in the Earth’s atmosphere and climate system. They scatter and absorb sunlight, serve as nuclei for water droplets and ice crystals in clouds and precipitation, and are a subject of concern for public health. Atmospheric aerosols originate from both natural and anthropogenic sources, and emissions resulting from human activities have the potential to influence the hydrological cycle and climate. An assessment of the extent and impacts of this human force requires a sound understanding of the natural aerosol background. This dissertation addresses the composition, properties, and atmospheric cycling of biogenic aerosol particles, which represent a major fraction of the natural aerosol burden. The main focal points are: (i) Studies of the autofluo-rescence of primary biological aerosol particles (PBAP) and its application in ambient measure-ments, and (ii) X-ray microscopic and spectroscopic investigations of biogenic secondary organic aerosols (SOA) from the Amazonian rainforest.rnAutofluorescence of biological material has received increasing attention in atmospheric science because it allows real-time monitoring of PBAP in ambient air, however it is associated with high uncertainty. This work aims at reducing the uncertainty through a comprehensive characterization of the autofluorescence properties of relevant biological materials. Fluorescence spectroscopy and microscopy were applied to analyze the fluorescence signatures of pure biological fluorophores, potential non-biological interferences, and various types of reference PBAP. Characteristic features and fingerprint patterns were found and provide support for the operation, interpretation, and further development of PBAP autofluorescence measurements. Online fluorescence detection and offline fluorescence microscopy were jointly applied in a comprehensive bioaerosol field measurement campaign that provided unprecedented insights into PBAP-linked biosphere-atmosphere interactions in a North-American semi-arid forest environment. Rain showers were found to trigger massive bursts of PBAP, including high concentrations of biological ice nucleators that may promote further precipitation and can be regarded as part of a bioprecipitation feedback cycle in the climate system. rnIn the pristine tropical rainforest air of the Amazon, most cloud and fog droplets form on bio-genic SOA particles, but the composition, morphology, mixing state and origin of these particles is hardly known. X-ray microscopy and spectroscopy (STXM-NEXAFS) revealed distinctly different types of secondary organic matter (carboxyl- vs. hydroxy-rich) with internal structures that indicate a strong influence of phase segregation, cloud and fog processing on SOA formation, and aging. In addition, nanometer-sized potassium-rich particles emitted by microorganisms and vegetation were found to act as seeds for the condensation of SOA. Thus, the influence of forest biota on the atmospheric abundance of cloud condensation nuclei appears to be more direct than previously assumed. Overall, the results of this dissertation suggest that biogenic aerosols, clouds and precipitation are indeed tightly coupled through a bioprecipitation cycle, and that advanced microscopic and spectroscopic techniques can provide detailed insights into these mechanisms.rn
Resumo:
In der vorliegenden Arbeit wird die Theorie der analytischen zweiten Ableitungen für die EOMIP-CCSD-Methode formuliert sowie die durchgeführte Implementierung im Quantenchemieprogramm CFOUR beschrieben. Diese Ableitungen sind von Bedeutung bei der Bestimmung statischer Polarisierbarkeiten und harmonischer Schwingungsfrequenzen und in dieser Arbeit wird die Genauigkeit des EOMIP-CCSD-Ansatzes bei der Berechnung dieser Eigenschaften für verschiedene radikalische Systeme untersucht. Des Weiteren können mit Hilfe der ersten und zweiten Ableitungen vibronische Kopplungsparameter berechnet werden, welche zur Simulation von Molekülspektren in Kombination mit dem Köppel-Domcke-Cederbaum (KDC)-Modell - in der Arbeit am Beispiel des Formyloxyl (HCO2)-Radikals demonstriert - benötigt werden.rnrnDer konzeptionell einfache EOMIP-CC-Ansatz wurde gewählt, da hier die Wellenfunktion eines Radikalsystems ausgehend von einem stabilen geschlossenschaligen Zustand durch die Entfernung eines Elektrons gebildet wird und somit die Problematik der Symmetriebrechung umgangen werden kann. Im Rahmen der Implementierung wurden neue Programmteile zur Lösung der erforderlichen Gleichungen für die gestörten EOMIP-CC-Amplituden und die gestörten Lagrange-Multiplikatoren zeta zum Quantenchemieprogramm CFOUR hinzugefügt. Die unter Verwendung des Programms bestimmten Eigenschaften werden hinsichtlich ihrer Leistungsfähigkeit im Vergleich zu etablierten Methoden wie z.B. CCSD(T) untersucht. Bei der Berechnung von Polarisierbarkeiten und harmonischen Schwingungsfrequenzen liefert die EOMIP-CCSD-Theorie meist gute Resultate, welche nur wenig von den CCSD(T)-Ergebnissen abweichen. Einzig bei der Betrachtung von Radikalen, für die die entsprechenden Anionen nicht stabil sind (z.B. NH2⁻ und CH3⁻), liefert der EOMIP-CCSD-Ansatz aufgrund methodischer Nachteile keine aussagekräftige Beschreibung. rnrnDie Ableitungen der EOMIP-CCSD-Energie lassen sich auch zur Simulation vibronischer Kopplungen innerhalb des KDC-Modells einsetzen.rnZur Kopplung verschiedener radikalischer Zustände in einem solchen Modellpotential spielen vor allem die Ableitungen von Übergangsmatrixelementen eine wichtige Rolle. Diese sogenannten Kopplungskonstanten können in der EOMIP-CC-Theorie besonders leicht definiert und berechnet werden. Bei der Betrachtung des Photoelektronenspektrums von HCO2⁻ werden zwei Alternativen untersucht: Die vertikale Bestimmung an der Gleichgewichtsgeometrie des HCO2⁻-Anions und die Ermittlung adiabatischer Kraftkonstanten an den Gleichgewichtsgeometrien des Radikals. Lediglich das adiabatische Modell liefert bei Beschränkung auf harmonische Kraftkonstanten eine qualitativ sinnvolle Beschreibung des Spektrums. Erweitert man beide Modelle um kubische und quartische Kraftkonstanten, so nähern sich diese einander an und ermöglichen eine vollständige Zuordnung des gemessenen Spektrums innerhalb der ersten 1500 cm⁻¹. Die adiabatische Darstellung erreicht dabei nahezu quantitative Genauigkeit.