10 resultados para CHROMATOGRAPHY-MASS-SPECTROMETRY
em ArchiMeD - Elektronische Publikationen der Universität Mainz - Alemanha
Resumo:
An accurate and sensitive species-specific GC-ICP-IDMS (gas chromatography inductively coupled plasma isotope dilution mass spectrometry) method for the determination of trimethyllead and a multi-species-specific GC-ICP-IDMS method for the simultaneous determination of trimethyllead, methylmercury, and butyltins in biological and environmental samples were developed. They allow the determination of corresponding elemental species down to the low ng g-1 range. The developed synthesis scheme for the formation of isotopically labeled Me3206Pb+ can be used for future production of this spike. The novel extraction technique, stir bar sorptive extraction (SBSE), was applied for the first time in connection with species-specific isotope dilution GC-ICP-MS for the determination of trimethyllead, methylmercury and butyltins. The results were compared with liquid-liquid extraction. The developed methods were validated by the analysis of certified reference materials. The liquid-liquid extraction GC-ICP-IDMS method was applied to seafood samples purchased from a supermarket. The methylated lead fraction in these samples, correlated to total lead, varied in a broad range of 0.01-7.6 %. On the contrary, the fraction of methylmercury is much higher, normally in the range of 80-98 %. The highest methylmercury content of up to 12 µg g-1 has been determined in shark samples, an animal which is at the end of the marine food chain, whereas in other seafood samples a MeHg+ content of less than 0.2 µg g-1 was found. Butyltin species could only be determined in samples, where anthropogenic contaminations must be assumed. This explains the observed broad variation of the butylated tin fraction in the range of <0.3-49 % in different seafood samples. Because all isotope-labelled spike compounds, except trimethyllead, are commercially available, the developed multi-species-specific GC-ICP-IDMS method has a high potential in future for routine analysis.
Resumo:
Within this PhD thesis matrix assisted laser desorption/ionization mass spectrometry (MALDI-MS) has been used as a reliable tool for the quantitative characterization of giant molecules, such as alkyl substituted and unsubstituted large polycyclic aromatic hydrocarbons (PAH), which cannot be characterized by conventional analytic techniques due to their lack of solubility. The use of the MALDI solvent-free technique for the sample preparation and the application of the standard addition method have allowed the quantitative characterization of synthetic PAH mixtures. The knowledge, acquired by studying these representative systems, has been then transferred to the quantitative analyses of complex and slightly soluble natural PAH mixtures, such as mesophase pitch. Moreover, the possibility to ionize intractable and insoluble molecules via mass spectrometry has been recognized to be not only a powerful analytical method, but also to represent a unique change to handle giant aromatic systems and to deposit them on a surface for further investigations, in a process, which is defined as “soft-landing”. Within this novel deposition technique, ions of the desired analytes or analyte mixtures are generated by means of an MS ionization source, discriminated by their different mass to charge ratios via a mass analyzer and landed with retention of their structure on a desired surface. This soft-deposition is guaranteed by the use of decelerating potentials, which have in this work been recognized to influence the final packing of the analyte molecules reaching the landing surface. For a more detailed study of the electrical field action on disc-like and rod-like molecules, soft-landing-independent experiments have been additionally carried out. As a result unidirectionally ordered films of the analyte molecules have been obtained due to the application of an external electrical strength. This versatile alignment technique has then been used for obtaining ordered layers of semiconducting materials for the fabrication of organic field effect transistors (OFET) with improved performances.
Resumo:
Heutzutage gewähren hochpräzise Massenmessungen mit Penning-Fallen tiefe Einblicke in die fundamentalen Eigenschaften der Kernmaterie. Zu diesem Zweck wird die freie Zyklotronfrequenz eines Ions bestimmt, das in einem starken, homogenen Magnetfeld gespeichert ist. Am ISOLTRAP-Massenspektrometer an ISOLDE / CERN können die Massen von kurzlebigen, radioaktiven Nukliden mit Halbwertszeiten bis zu einigen zehn ms mit einer Unsicherheit in der Größenordnung von 10^-8 bestimmt werden. ISOLTRAP besteht aus einem Radiofrequenz-Quadrupol zum akkumulieren der von ISOLDE gelieferten Ionen, sowie zwei Penning-Fallen zum säubern und zur Massenbestimmung der Ionen. Innerhalb dieser Arbeit wurden die Massen von neutronenreichen Xenon- und Radonisotopen (138-146Xe und 223-229Rn) gemessen. Für elf davon wurde zum ersten Mal die Masse direkt bestimmt; 229Rn wurde im Zuge dieses Experimentes sogar erstmalig beobachtet und seine Halbwertszeit konnte zu ungefähr 12 s bestimmt werden. Da die Masse eines Nuklids alle Wechselwirkungen innerhalb des Kerns widerspiegelt, ist sie einzigartig für jedes Nuklid. Eine dieser Wechselwirkungen, die Wechselwirkung zwischen Protonen und Neutronen, führt zum Beispiel zu Deformationen. Das Ziel dieser Arbeit ist eine Verbindung zwischen kollektiven Effekten, wie Deformationen und Doppeldifferenzen von Bindungsenergien, sogenannten deltaVpn-Werten zu finden. Insbesondere in den hier untersuchten Regionen zeigen deltaVpn-Werte ein sehr ungewöhnliches Verhalten, das sich nicht mit einfachen Argumenten deuten lässt. Eine Erklärung könnte das Auftreten von Oktupoldeformationen in diesen Gebieten sein. Nichtsdestotrotz ist eine quantitative Beschreibung von deltaVpn-Werten, die den Effekt von solchen Deformationen berücksichtigt mit modernen Theorien noch nicht möglich.
Resumo:
In this study the Aerodyne Aerosol Mass Spectrometer (AMS) was used during three laboratory measurement campaigns, FROST1, FROST2 and ACI-03. The FROST campaigns took place at the Leipzig Aerosol Cloud Interaction Simulator (LACIS) at the IfT in Leipzig and the ACI-03 campaign was conducted at the AIDA facility at the Karlsruhe Institute of Technology (KIT). In all three campaigns, the effect of coatings on mineral dust ice nuclei (IN) was investigated. During the FROST campaigns, Arizona Test Dust (ATD) particles of 200, 300 and 400 nm diameter were coated with thin coatings (< 7 nm) of sulphuric acid. At these very thin coatings, the AMS was operated close to its detection limits. Up to now it was not possible to accurately determine AMS detection limits during regular measurements. Therefore, the mathematical tools to analyse the detection limits of the AMS have been improved in this work. It is now possible to calculate detection limits of the AMS under operating conditions, without losing precious time by sampling through a particle filter. The instrument was characterised in more detail to enable correct quantification of the sulphate loadings on the ATD particle surfaces. Correction factors for the instrument inlet transmission, the collection efficiency, and the relative ionisation efficiency have been determined. With these corrections it was possible to quantify the sulphate mass per particle on the ATD after the condensation of sulphuric acid on its surface. The AMS results have been combined with the ice nucleus counter results. This revealed that the IN-efficiency of ATD is reduced when it is coated with sulphuric acid. The reason for this reduction is a chemical reaction of sulphuric acid with the particle's surface. These reactions are increasingly taking place when the aerosol is humidified or heated after the coating with sulphuric acid. A detailed analysis of the solubility and the evaporation temperature of the surface reaction products revealed that most likely aluminium sulphate is produced in these reactions.
Resumo:
The composition of the atmosphere is frequently perturbed by the emission of gaseous and particulate matter from natural as well as anthropogenic sources. While the impact of trace gases on the radiative forcing of the climate is relatively well understood the role of aerosol is far more uncertain. Therefore, the study of the vertical distribution of particulate matter in the atmosphere and its chemical composition contribute valuable information to bridge this gap of knowledge. The chemical composition of aerosol reveals information on properties such as radiative behavior and hygroscopicity and therefore cloud condensation or ice nucleus potential. rnThis thesis focuses on aerosol pollution plumes observed in 2008 during the POLARCAT (Polar Study using Aircraft, Remote Sensing, Surface Measurements and Models, of Climate, Chemistry, Aerosols, and Transport) campaign over Greenland in June/July and CONCERT (Contrail and Cirrus Experiment) campaign over Central and Western Europe in October/November. Measurements were performed with an Aerodyne compact time-of-flight aerosol mass spectrometer (AMS) capable of online size-resolved chemical characterization of non-refractory submicron particles. In addition, the origins of pollution plumes were determined by means of modeling tools. The characterized pollution episodes originated from a large variety of sources and were encountered at distinct altitudes. They included pure natural emissions from two volcanic eruptions in 2008. By the time of detection over Western Europe between 10 and 12 km altitude the plume was about 3 months old and composed to 71 % of particulate sulfate and 21 % of carbonaceous compounds. Also, biomass burning (BB) plumes were observed over Greenland between 4 and 7 km altitude (free troposphere) originating from Canada and East Siberia. The long-range transport took roughly one and two weeks, respectively. The aerosol was composed of 78 % organic matter and 22 % particulate sulfate. Some Canadian and all Siberian BB plumes were mixed with anthropogenic emissions from fossil fuel combustion (FF) in North America and East Asia. It was found that the contribution of particulate sulfate increased with growing influences from anthropogenic activity and Asia reaching up to 37 % after more than two weeks of transport time. The most exclusively anthropogenic emission source probed in the upper troposphere was engine exhaust from commercial aircraft liners over Germany. However, in-situ characterization of this aerosol type during aircraft chasing was not possible. All long-range transport aerosol was found to have an O:C ratio close to or greater than 1 implying that low-volatility oxygenated organic aerosol was present in each case despite the variety of origins and the large range in age from 3 to 100 days. This leads to the conclusion that organic particulate matter reaches a final and uniform state of oxygenation after at least 3 days in the free troposphere. rnExcept for aircraft exhaust all emission sources mentioned above are surface-bound and thus rely on different types of vertical transport mechanisms, such as direct high altitude injection in the case of a volcanic eruption, or severe BB, or uplift by convection, to reach higher altitudes where particles can travel long distances before removal mainly caused by cloud scavenging. A lifetime for North American mixed BB and FF aerosol of 7 to 11 days was derived. This in consequence means that emission from surface point sources, e.g. volcanoes, or regions, e.g. East Asia, do not only have a relevant impact on the immediate surroundings but rather on a hemispheric scale including such climate sensitive zones as the tropopause or the Arctic.
Resumo:
Eisbohrkerne stellen wertvolle Klimaarchive dar, da sie atmosphärisches Aerosol konservieren. Die Analyse chemischer Verbindungen als Bestandteil atmosphärischer Aerosole in Eisbohrkernen liefert wichtige Informationen über Umweltbedingungen und Klima der Vergangenheit. Zur Untersuchung der α-Dicarbonyle Glyoxal und Methylglyoxal in Eis- und Schneeproben wurde eine neue, sensitive Methode entwickelt, die die Stir Bar Sorptive Extraction (SBSE) mit der Hochleistungsflüssigchromatographie-Massenspektrometrie (HPLC-MS) kombiniert. Zur Analyse von Dicarbonsäuren in Eisbohrkernen wurde eine weitere Methode entwickelt, bei der die Festphasenextraktion mit starkem Anionenaustauscher zum Einsatz kommt. Die Methode erlaubt die Quantifizierung aliphatischer Dicarbonsäuren (≥ C6), einschließlich Pinsäure, sowie aromatischer Carbonsäuren (wie Phthalsäure und Vanillinsäure), wodurch die Bestimmung wichtiger Markerverbindungen für biogene und anthropogene Quellen ermöglicht wurde. Mit Hilfe der entwickelten Methoden wurde ein Eisbohrkern aus den Schweizer Alpen analysiert. Die ermittelten Konzentrationsverläufe der Analyten umfassen die Zeitspanne von 1942 bis 1993. Mittels einer Korrelations- und Hauptkomponentenanalyse konnte gezeigt werden, dass die organischen Verbindungen im Eis hauptsächlich durch Waldbrände und durch vom Menschen verursachte Schadstoffemissionen beeinflusst werden. Im Gegensatz dazu sind die Konzentrationsverläufe einiger Analyten auf den Mineralstaubtransport auf den Gletscher zurückzuführen. Zusätzlich wurde ein Screening der Eisbohrkernproben mittels ultrahochauflösender Massenspektrometrie durchgeführt. Zum ersten Mal wurden in diesem Rahmen auch Organosulfate und Nitrooxyorganosulfate in einem Eisbohrkern identifiziert.
Resumo:
Reactive halogen compounds are known to play an important role in a wide variety of atmospheric processes such as atmospheric oxidation capacity and coastal new particle formation. In this work, novel analytical approaches combining diffusion denuder/impinger sampling techniques with gas chromatographic–mass spectrometric (GC–MS) determination are developed to measure activated chlorine compounds (HOCl and Cl2), activated bromine compounds (HOBr, Br2, BrCl, and BrI), activated iodine compounds (HOI and ICl), and molecular iodine (I2). The denuder/GC–MS methods have been used to field measurements in the marine boundary layer (MBL). High mixing ratios (of the order of 100 ppt) of activated halogen compounds and I2 are observed in the coastal MBL in Ireland, which explains the ozone destruction observed. The emission of I2 is found to correlate inversely with tidal height and correlate positively with the levels of O3 in the surrounding air. In addition the release is found to be dominated by algae species compositions and biomass density, which proves the “hot-spot” hypothesis of atmospheric iodine chemistry. The observations of elevated I2 concentrations substantially support the existence of higher concentrations of littoral iodine oxides and thus the connection to the strong ultra-fine particle formation events in the coastal MBL.
Resumo:
Flüchtige organische Verbindungen (volatile organic compounds, VOCs), besonders rnTerpene, gelten als Vorläufer des sekundären organischen Aerosols (secondary rnorganic aerosols, SOA). Terpene werden von Pflanzen zur Abwehr oder zur rnAttraktion von Bestäubern emittiert. Ungesättigten Verbindungen, wie Sesquiterpene, rnsind sehr ozonolyseempfindlich und weisen nur geringe Konzentrationen in der rnAtmosphäre auf. Zudem lassen sie sich mit handelsüblichen rnThermodesorptionseinheiten meist nicht ohne Artefakte nachweisen, da sie eine hohe rnReaktivität mit vielen Oberflächen zeigen. rnDiese Arbeit präsentiert Forschungsergebnisse der qualitativen und rn(semi)quantitativen Auswertungen flüchtiger organischer Verbindungen in rnLaborstudien und biogenen Emissionsproben (Feldmessungen) mittels rnThermodesorption-Gaschromatographie-Massenspektrometrie (TD-GC/MS). Speziell rnzur Analyse hochreaktiver Verbindungen wurde eine Thermodesorptionseinheit für die rnGC/MS entwickelt. Diese besteht aus einer Kryofokussierung, einem Desorptionsofen rnund einer Heizung. Die Steuerung erfolgt über eine eigens dafür geschaffene rnBedienoberf läche von Labview® an einem PC über eine nachgeschaltete SPS rn(speicherprogrammierbare Steuerung). Das komplette Desorptionsprogramm und der rnStart der GC/MS-Analyse wurden automatisiert. rnDie Quantifizierung alle Proben wurde über Diffusionsquellen und rnVergleichsmessungen durch auf Adsorptionsröhrchen aufgebrachte rnVerdünnungsreihen realisiert. Um Informationen über die mutmaßlichen Vorläufer des rnsekundären organischen Aerosols zu erhalten, wurde zudem eine Ozon-Scrubber-rnMethode basierend auf Propen entwickelt. Diese wurde anhand von Standards in einer rnReaktionskammer getestet und in Feldmessungen erfolgreich angewendet. rnQuantitative Analysen zeigen, dass die meisten Terpene so vollständig vor der rnOzonolyse bewahrt werden können. Für hochreaktive Analyte wie α-Humulen oder rnβ-Caryophyllen wurden Wiederfindungsraten von über 80 % erreicht. So konnte die rnTemperaturabhängigkeit der Terpen-Emissionen der Fichte (Picea abies) in rnFeldmessungen nachgewiesen werden. rnEine weitere Anwendungsmöglichkeit wurde mit der Unterscheidung verschiedener rnArten der gleichen Gattung anhand der Emissionsmuster und der möglichen rnAbgrenzung verschiedener Bestäubertypen am Beispiel der Gattung Salvia untersucht. rnDie Emissionsanalysen zeigen, dass eine Zuordnung der Verwandtschaftsverhältnisse rnzusätzlich zu anderen Vergleichen möglich ist. Das gleiche gilt für die Differenzierung rnvon Bestäubertypen. Die Ergebnisse der Feldmessungen wurden durch rnMethodenvergleich zwischen biogenen Emissionsmessungen mit anschließender rnTD-GC/MS-Analyse und Extraktionen der jeweiligen Blüten/Blätter mit rnanschließender GC/MS-Messung bestätigt.
Resumo:
Flüchtige organische Halogenverbindungen übernehmen in der Chemie der Troposphäre eine Schlüsselrolle. Photolytisch gebildete Halogenatome reagieren mit troposphärischem Ozon und können durch Oxidation, vor allem von Iod, zur Neubildung von Partikeln beitragen. Auf diese Weise beeinflussen Halogenalkane den Strahlungshaushalt der Atmosphäre. Aus analytischem Blickwinkel ist es wichtig die Konzentration der einzelnen Spezies zu untersuchen um Rückschlüsse auf deren biotische oder abiotische Quellen ziehen und die Emissionswege besser verstehen zu können. Im Rahmen der vorliegenden Arbeit wurde daher eine sensitive Methode zur Untersuchung von halogenierten Kohlenwasserstoffen entwickelt, basierend auf anreichernder Probenahme mit anschließender Thermodesorption und der Analyse mittels Massenspektrometrie mit negativer chemischer Ionisation. Die Kennwerte der Methode sind: Nachweisgrenzen zwischen 0.11 pg und 5.86 pg bzw. zwischen 1.0 ppqV und 44.7 ppqV, Linearität zwischen R2=0.993 und R2=1.000, Reproduzierbarkeit (Triplikate) RSD < 15 % und ein sicheres Probenahmevolumen von 10 L. Die Methode wurde im Anschluss im Rahmen von zwei Feldmessungen, in Mace Head, Irland und auf einer Schiffskampagne im antarktischen Amundsen-Meer, angewendet. Durch die Ergebnisse aus Irland kann gezeigt werden, dass die Mischungsverhältnisse der Iodalkane mit denen früherer Studien vergleichbar sind, und dass die verschiedenen untersuchten Algenarten deutlich unterschiedliche Emissionsraten zeigen. Die Ergebnisse der Kampagne im Amundsen-Meer zeigen einen großen Einfluss der Windrichtung auf die Halogenalkan-Konzentrationen. So sind die Mischungsverhältnisse der Halogenalkane deutlich höher, wenn der Wind zuvor über die antarktischen Eisflächen strömt. Für die biotischen Quellen wurden die Emissionsraten ausgewählter Makroalgen unter dem Einfluss von Ozon untersucht. Die Emissionsrate der Iodalkane zeigt einen exponentiellen Zusammenhang, sowohl zur I2-Emission als auch zum Gesamtiodgehalt der Algen. Unter oxidativen Bedingungen zeigt L. Digitata eine linear steigende Iodalkanemission. Mit diesem Verhalten wird die These der Bildung von Iodalkanen als Nebenprodukt beim Abbau reaktiver Sauerstoffspezies unterstützt. Neben den Makroalgen wurden auch Mikroalgen als biotische Quellen untersucht. Hierbei können zwei unterschiedliche Emissionsmuster der Halogenalkane für Diatomeen und Phaeocystis sp. gezeigt werden. Im Gegensatz zur Iodalkan-Emission hängt die I2 Emission der Mikroalgenproben von der Ozonkonzentration der Luft ab. Durch die lineare Korrelation der I2-Emission mit der Iodid-Konzentration der wässrigen Phase einerseits, und dem Ozonverbrauch andererseits, kann die Bildung von I2 durch Oxidation von Iodid durch Ozon bestätigt werden. Für das Emissionsverhalten der Mikroalgenprobe aus dem Sylter Wattenmeer, welche keine Korrelation mit dem verbrauchten Ozon zeigt, gibt es zwei Erklärungen: Zum einen kann I2 durch den hohen Gehalt an organischen Verbindungen an diesen adsorbiert bzw. chemisch gebunden werden und wird dann nicht mehr in die Gasphase emittiert. Zum anderen können aktive organische Verbindungen das Gleichgewicht zwischen HOI und I2 in Richtung HOI verlagern. Im Versuch zur abiotischen Bildung von Iodalkanen aus Partikeln, bestehend aus I2O5 und verschiedenen Alkoholen, kann gezeigt werden, dass die Bildung von Iodmethan und Diiodmethan abläuft, dass jedoch die Emission bis zu zwei Größenordnungen kleiner ist als die von I2. Somit trägt die Bildung von Iodalkanen nur in einem sehr eingeschränkten Rahmen zum Recycling des Iods in der Atmosphäre bei. Der vorgestellte abiotische Bildungsweg hängt sowohl vom pH-Wert als auch vom Mischungsverhältnis im Partikel ab.
Resumo:
In den letzten Jahren stieg in Deutschland der Gebrauch bzw. Missbrauch von Opioid-Analgetika zunehmend an. Das entwickelte Verfahren sollte unter Einbeziehung neuer Substanzen möglichst viele verschiedene Opioide und auch ihre pharmakologisch aktiven Stoffwechselprodukte berücksichtigen.rnVor Analyse wurden Blut-, Serum- oder Urinproben mit Phosphatpuffer versetzt und mittels Festphasenextraktion an C18-Säulenmaterial aufgearbeitet. Post-Mortem-Gewebematerial wurde mit isotonischer Kochsalzlösung versetzt, homogenisiert und anschließend durch eine Festphasenextraktion aufgereinigt. Haarproben wurden nach Zerkleinerung mit Methanol unter Ultrabeschallung extrahiert. Die Flüssigchromatographie gekoppelt mit Tandem-Massenspektrometrie (Elektrosprayionisation im positiven Modus) erwies sich als geeignetes Verfahren für die simultane Bestimmung der Opioide in biologischem Probenmaterial (Körperflüssigkeiten, Gewebe und Haaren). Der Multi-Analyt Assay erlaubt die quantitative Analyse von 35 verschiedenen Opioiden. Die Analyten wurden durch eine Phenyl-Hexyl Säule und einen Wasser/Acetonitril Gradienten durch eine UPLC 1290 Infinity gekoppelt mit einem 6490 Triple Quadrupol von Agilent Technologies separiert.rnDie LC/MS Methode zur simultanen Bestimmung von 35 Opioiden in Serum und Haaren wurde nach den Richtlinien der Gesellschaft für Toxikologische und Forensische Chemie (GTFCh) validiert. Im Fall der Serumvalidierung lagen die Nachweisgrenzen zwischen 0.02 und 0.6 ng/ml und die Bestimmungsgrenzen im Bereich von 0.1 bis 2.0 ng/ml. Die Kalibrationskurven waren für die Kalibrationslevel 1 bis 6 linear. Wiederfindungsraten lagen für alle Verbindungen zwischen 51 und 88 %, außer für Alfentanil, Bisnortiliidn, Pethidin und Morphin-3-Glucuronid. Der Matrixeffekt lag zwischen 86 % (Ethylmorphin) und 105 % (Desomorphin). Für fast alle Analyten konnten akzeptable Werte bei der Bestimmung der Genauigkeit und Richtigkeit nach den Richtlinien der GTFCh erhalten werden. Im Fall der Validierung der Haarproben lagen die Nachweisgrenzen zwischen 0.004 und 0.6 ng/Probe und die Bestimmungsgrenzen zwischen 0.1 ng/Probe und 2.0 ng/Probe. Für die Kalibrationslevel 1 bis 6 waren alle Kalibrationsgeraden linear. Die Wiederfindungsraten lagen für die Opioide im Bereich von 73.5 % (Morphin-6-Glucuronid) und 114.1 % (Hydrocodon). Die Werte für die Bestimmung der Richtigkeit lagen zwischen - 6.6 % (Methadon) und + 11.7 % (Pholcodin). Präzisionsdaten wurden zwischen 1.0 % für Dextromethorphan und 11.5 % für Methadon ermittelt. Die Kriterien der GTFCh konnten bei Ermittlung des Matrixeffekts für alle Substanzen erfüllt werden, außer für 6-Monoacetylmorphin, Bisnortilidin, Meperidin, Methadon, Morphin-3-glucuronid, Morphin-6-glucuronid, Normeperidin, Nortilidin und Tramadol.rnZum Test des Verfahrens an authentischem Probenmaterial wurden 206 Proben von Körperflüssigkeiten mit Hilfe der simultanen LC/MS Screening Methode untersucht. Über 150 Proben wurden im Rahmen von forensisch-toxikologischen Untersuchungen am Instituts für Rechtsmedizin Mainz analysiert. Dabei konnten 23 der 35 Opioide in den realen Proben nachgewiesen werden. Zur Untersuchung der Pharmakokinetik von Opioiden bei Patienten der anästhesiologischen Intensivstation mit Sepsis wurden über 50 Blutproben untersucht. Den Patienten wurde im Rahmen einer klinischen Studie einmal täglich vier Tage lang Blut abgenommen. In den Serumproben wurde hauptsächlich Sufentanil (0.2 – 0.8 ng/ml in 58 Fällen) und Piritramid (0.4 – 11 ng/ml in 56 Fällen) gefunden. Außerdem wurden die Proben von Körperflüssigkeiten und Gewebe von 13 verschiedenen Autopsiefällen mit Hilfe des Multi-Analyt Assays auf Opioide untersucht.rnIn einem zweiten Schritt wurde die Extraktions- und Messmethode zur Quantifizierung der 35 Opioide am Forensic Medicine Center in Ho Chi Minh City (Vietnam) etabliert. Insgesamt wurden 85 Herzblutproben von Obduktionsfällen mit Verdacht auf Opiatintoxikation näher untersucht. Der überwiegende Teil der untersuchten Fälle konnte auf eine Heroin- bzw. Morphin-Vergiftung zurückgeführt werden. Morphin wurde in 68 Fällen im Konzentrationsbereich 1.7 – 1400 ng/ml und der Heroinmetabolit 6-Monoactetylmorphin in 34 Fällen (0.3 – 160 ng/ml) nachgewiesen werden.rnSchließlich wurden noch 15 Haarproben von Patienten einer psychiatrischen Klinik, die illegale Rauschmittel konsumiert hatten, mit Hilfe der simultanen Opioid-LC/MS Screeningmethode gemessen. Die Ergebnisse der Untersuchung wurden mit früheren Auswertungen von gaschromatographischen Analysen verglichen. Es zeigte sich eine weitgehende Übereinstimmung der Untersuchungsergebnisse für die Opioide 6-Monoacetylmorphin, Morphin, Codein, Dihydrocodein und Methadon. Mit der LC/MS Methode konnten weitere Substanzen, wie zum Beispiel Bisnortilidin, Dextromethorphan und Tramadol in den Haarproben gefunden werden, die bislang nicht entdeckt worden waren.rn