17 resultados para electric energy
em Universidade Federal do Rio Grande do Norte(UFRN)
Resumo:
Cells the solid oxide fuel are systems capable to directly convert energy of a chemical reaction into electric energy in clean, quiet way and if its components in the solid state differentiate of excessively the techniques for having all. Its more common geometric configurations are: the tubular one and to glide. Geometry to glide beyond the usual components (anode, cathode and electrolyte) needs interconnect and sealant. E the search for materials adjusted for these components is currently the biggest challenge found for the production of the cells. The sealants need to present chemical stability in high temperatures, to provoke electric isolation, to have coefficient of compatible thermal expansion with the excessively component ones. For presenting these characteristics the glass-ceramics materials are recommended for the application. In this work the study of the partial substitution of the ZrO2 for the Al2O3 in system LZS became it aiming at the formation of system LZAS, this with the addition of natural spodumene with 10, 20 and 30% in mass. The compositions had been casting to a temperature of 1500°C and later quickly cooled with the objective to continue amorphous. Each composition was worn out for attainment of a dust with average diameter of approximately 3μm and characterized by the techniques of DRX, FRX, MEV, dilatometric analysis and particle size analysis. Later the samples had been conformed and treated thermally with temperatures in the interval between 700-1000 °C, with platform of 10 minutes and 1 hour. The analyses for the treated samples had been: dilatometric analysis, DRX, FRX, electrical conductivity and tack. The results point with respect to the viability of the use of system LZAS for use as sealant a time that had presented good results as isolating electric, they had adhered to a material with similar α of the components of a SOFC and had presented steady crystalline phases
Resumo:
The present work has as aim to analyze the reorganization process of the rural education in Jardim de Piranhas-RN, on the context of the education policies, in particular of the period of 1999-2006, having as reference the transformations in the political, cultural and socio-economic setting in the national, regional and local level, above all from the decade of 1990. The studies carried out in diverse sources made possible to understand from the context in which they had developed the education policies, in particular, that one directed for the rural way, as well as the mediation of this with the education reorganization in the local scope. Besides these research procedures, we carry out interviews - semi-structuralized - with managers and teachers, and we analyze documents from the produced ones in national level to those local ones. From the viewpoint theoretician-methodological, we focus the national discussion that comes developing under a new ideological political configuration and, being entitled by the Field Education, understood as a policy directed to education specifities in this sector and consolidated in the Operational Guidelines for the Basic Education in the Field Schools (CNE/MEC/2002). As particularity of this object in Jardim de Piranhas-RN, we emphasize events occurred that had marked the rural education reorganization in that city, especially from the creation of the Rural Education named Center Teacher Maria Edite Batista. Studies make possible to realize that until the Center creation, the schools functioned in rather precarious infrastructure and physical conditions, that is, without electric energy and water supplying, as well as the lack of school snack and the management structure. There was not a project or specific pedagogical accompaniment for the sector. Moreover, the teachers worked predominantly with several grade classes and still they fulfilled the manager functions, caretakers, and cook- in some cases as school secretary. However, exactly with the creation of the Rural Education Center, the education municipal system did not become capable to overcome problems as of the evasion and school failure, as well as decreasing the work overload of teachers, neither to give greater consistency to the pedagogical project of the field schools in that city
Resumo:
A modeling of criterias and alternatives is through and applied a questionnaire based on method AHP to proprietors of gas stations. The considered alternatives had been the maintenance of the current state with electric energy of the deliverer and the generation in small scale based on the natural gas. The used criteria had been Cost of the Investment, Final Cost of the Energy, Operational cost, Ambient Benefits, Risk and Variation of Costs. The study it was carried through in the city of Natal, RN in ranks that make use of the natural as for resale, where the generation alternative on the basis of the available gas is present. The main results evidence in a dimension the viability of use of method AHP with questionnaire by means of validation of the judgments with analysis of variance beyond proper the normal mechanisms of analysis of consistency to the method. The main results of the analysis help to show that in this in case that the profile of models of criteria and judgments of the actors is similar, with the final evidence of that it has a dominance of the maintenance of the energy of the deliverer. The main criterion to influence this decision was the risk
Resumo:
The usual programs for load flow calculation were in general developped aiming the simulation of electric energy transmission, subtransmission and distribution systems. However, the mathematical methods and algorithms used by the formulations were based, in majority, just on the characteristics of the transmittion systems, which were the main concern focus of engineers and researchers. Though, the physical characteristics of these systems are quite different from the distribution ones. In the transmission systems, the voltage levels are high and the lines are generally very long. These aspects contribute the capacitive and inductive effects that appear in the system to have a considerable influence in the values of the interest quantities, reason why they should be taken into consideration. Still in the transmission systems, the loads have a macro nature, as for example, cities, neiborhoods, or big industries. These loads are, generally, practically balanced, what reduces the necessity of utilization of three-phase methodology for the load flow calculation. Distribution systems, on the other hand, present different characteristics: the voltage levels are small in comparison to the transmission ones. This almost annul the capacitive effects of the lines. The loads are, in this case, transformers, in whose secondaries are connected small consumers, in a sort of times, mono-phase ones, so that the probability of finding an unbalanced circuit is high. This way, the utilization of three-phase methodologies assumes an important dimension. Besides, equipments like voltage regulators, that use simultaneously the concepts of phase and line voltage in their functioning, need a three-phase methodology, in order to allow the simulation of their real behavior. For the exposed reasons, initially was developped, in the scope of this work, a method for three-phase load flow calculation in order to simulate the steady-state behaviour of distribution systems. Aiming to achieve this goal, the Power Summation Algorithm was used, as a base for developing the three phase method. This algorithm was already widely tested and approved by researchers and engineers in the simulation of radial electric energy distribution systems, mainly for single-phase representation. By our formulation, lines are modeled in three-phase circuits, considering the magnetic coupling between the phases; but the earth effect is considered through the Carson reduction. It s important to point out that, in spite of the loads being normally connected to the transformer s secondaries, was considered the hypothesis of existence of star or delta loads connected to the primary circuit. To perform the simulation of voltage regulators, a new model was utilized, allowing the simulation of various types of configurations, according to their real functioning. Finally, was considered the possibility of representation of switches with current measuring in various points of the feeder. The loads are adjusted during the iteractive process, in order to match the current in each switch, converging to the measured value specified by the input data. In a second stage of the work, sensibility parameters were derived taking as base the described load flow, with the objective of suporting further optimization processes. This parameters are found by calculating of the partial derivatives of a variable in respect to another, in general, voltages, losses and reactive powers. After describing the calculation of the sensibility parameters, the Gradient Method was presented, using these parameters to optimize an objective function, that will be defined for each type of study. The first one refers to the reduction of technical losses in a medium voltage feeder, through the installation of capacitor banks; the second one refers to the problem of correction of voltage profile, through the instalation of capacitor banks or voltage regulators. In case of the losses reduction will be considered, as objective function, the sum of the losses in all the parts of the system. To the correction of the voltage profile, the objective function will be the sum of the square voltage deviations in each node, in respect to the rated voltage. In the end of the work, results of application of the described methods in some feeders are presented, aiming to give insight about their performance and acuity
Resumo:
The usual programs for load flow calculation were in general developped aiming the simulation of electric energy transmission, subtransmission and distribution systems. However, the mathematical methods and algorithms used by the formulations were based, in majority, just on the characteristics of the transmittion systems, which were the main concern focus of engineers and researchers. Though, the physical characteristics of these systems are quite different from the distribution ones. In the transmission systems, the voltage levels are high and the lines are generally very long. These aspects contribute the capacitive and inductive effects that appear in the system to have a considerable influence in the values of the interest quantities, reason why they should be taken into consideration. Still in the transmission systems, the loads have a macro nature, as for example, cities, neiborhoods, or big industries. These loads are, generally, practically balanced, what reduces the necessity of utilization of three-phase methodology for the load flow calculation. Distribution systems, on the other hand, present different characteristics: the voltage levels are small in comparison to the transmission ones. This almost annul the capacitive effects of the lines. The loads are, in this case, transformers, in whose secondaries are connected small consumers, in a sort of times, mono-phase ones, so that the probability of finding an unbalanced circuit is high. This way, the utilization of three-phase methodologies assumes an important dimension. Besides, equipments like voltage regulators, that use simultaneously the concepts of phase and line voltage in their functioning, need a three-phase methodology, in order to allow the simulation of their real behavior. For the exposed reasons, initially was developped, in the scope of this work, a method for three-phase load flow calculation in order to simulate the steady-state behaviour of distribution systems. Aiming to achieve this goal, the Power Summation Algorithm was used, as a base for developping the three phase method. This algorithm was already widely tested and approved by researchers and engineers in the simulation of radial electric energy distribution systems, mainly for single-phase representation. By our formulation, lines are modeled in three-phase circuits, considering the magnetic coupling between the phases; but the earth effect is considered through the Carson reduction. Its important to point out that, in spite of the loads being normally connected to the transformers secondaries, was considered the hypothesis of existence of star or delta loads connected to the primary circuit. To perform the simulation of voltage regulators, a new model was utilized, allowing the simulation of various types of configurations, according to their real functioning. Finally, was considered the possibility of representation of switches with current measuring in various points of the feeder. The loads are adjusted during the iteractive process, in order to match the current in each switch, converging to the measured value specified by the input data. In a second stage of the work, sensibility parameters were derived taking as base the described load flow, with the objective of suporting further optimization processes. This parameters are found by calculating of the partial derivatives of a variable in respect to another, in general, voltages, losses and reactive powers. After describing the calculation of the sensibility parameters, the Gradient Method was presented, using these parameters to optimize an objective function, that will be defined for each type of study. The first one refers to the reduction of technical losses in a medium voltage feeder, through the installation of capacitor banks; the second one refers to the problem of correction of voltage profile, through the instalation of capacitor banks or voltage regulators. In case of the losses reduction will be considered, as objective function, the sum of the losses in all the parts of the system. To the correction of the voltage profile, the objective function will be the sum of the square voltage deviations in each node, in respect to the rated voltage. In the end of the work, results of application of the described methods in some feeders are presented, aiming to give insight about their performance and acuity
Resumo:
T'his dissertation proposes alternative models to allow the interconnectioin of the data communication networks of COSERN Companhia Energética do Rio Grande do Norte. These networks comprise the oorporative data network, based on TCP/IP architecture, and the automation system linking remote electric energy distribution substations to the main Operatin Centre, based on digital radio links and using the IEC 60870-5-101 protoco1s. The envisaged interconnection aims to provide automation data originated from substations with a contingent route to the Operation Center, in moments of failure or maintenance of the digital radio links. Among the presented models, the one chosen for development consists of a computational prototype based on a standard personal computer, working under LINUX operational system and running na application, developesd in C language, wich functions as a Gateway between the protocols of the TCP/IP stack and the IEC 60870-5-101 suite. So, it is described this model analysis, implementation and tests of functionality and performance. During the test phase it was basically verified the delay introduced by the TCP/IP network when transporting automation data, in order to guarantee that it was cionsistent with the time periods present on the automation network. Besides , additional modules are suggested to the prototype, in order to handle other issues such as security and prioriz\ation of the automation system data, whenever they are travesing the TCP/IP network. Finally, a study hás been done aiming to integrate, in more complete way, the two considered networks. It uses IP platform as a solution of convergence to the communication subsystem of na unified network, as the most recente market tendencies for supervisory and other automation systems indicate
Resumo:
The Electrical Submersible Pump (ESP) has been one of the most appropriate solutions for lifting method in onshore and offshore applications. The typical features for this application are adverse temperature, viscosity fluids and gas environments. The difficulties in equipments maintenance and setup contributing to increasing costs of oil production in deep water, therefore, the optimization through automation can be a excellent approach for decrease costs and failures in subsurface equipment. This work describe a computer simulation related with the artificial lifting method ESP. This tool support the dynamic behavior of ESP approach, considering the source and electric energy transmission model for the motor, the electric motor model (including the thermal calculation), flow tubbing simulation, centrifugal pump behavior simulation with liquid nature effects and reservoir requirements. In addition, there are tri-dimensional animation for each ESP subsytem (transformer, motor, pump, seal, gas separator, command unit). This computer simulation propose a improvement for monitoring oil wells for maximization of well production. Currenty, the proprietaries simulators are based on specific equipments manufactures. Therefore, it is not possible simulation equipments of another manufactures. In the propose approach there are support for diverse kinds of manufactures equipments
Resumo:
The electric energy is essential to the development of modern society and its increasing demand in recent years, effect from population and economic growth, becomes the companies more interested in the quality and continuity of supply, factors regulated by ANEEL (Agência Nacional de Energia Elétrica). These factors must be attended when a permanent fault occurs in the system, where the defect location that caused the power interruption should be identified quickly, which is not a simple assignment because the current systems complexity. An example of this occurs in multiple terminals transmission lines, which interconnect existing circuits to feed the demand. These transmission lines have been adopted as a feasible solution to suply loads of magnitudes that do not justify economically the construction of new substations. This paper presents a fault location algorithm for multiple terminals transmission lines - two and three terminals. The location method is based on the use of voltage and current fundamental phasors, as well as the representation of the line through its series impedance. The wavelet transform is an effective mathematical tool in signals analysis with discontinuities and, therefore, is used to synchronize voltage and current data. The Fourier transform is another tool used in this work for extract voltage and current fundamental phasors. Tests to validate the location algorithm applicability used data from faulty signals simulated in ATP (Alternative Transients Program) as well as real data obtained from oscillographic recorders installed on CHESF s lines.
Resumo:
One of the most important decisions to turn a substation automatic and no attended it relates to the communication media between this substation and Operation Center. Generally energy companies uses radio or optic fiber, depending of distances and infrastructure of each situation. This rule applies to common substations. Mobile substations are a particular case, therefore they are conceived for use at provisional situations, emergencies, preventive or corrective maintenance. Thus the telecommunication solution used at common substations are not applied so easily to mobile substations, due absence of infrastructure (media) or difficulty to insert the mobile substation data in existing automation network not long. The ideal media must supply covering in a great geographic area to satisfy presented requirements. The implantation costs of this big infrastructure are expensive, however a existing operator may be used. Two services that fulfill that requirements are satellite and cellular telephony. This work presents a solution for automation of mobile substations through satellite. It was successfully implanted at a brazilian electric energy concessionaire named COSERN. The operation became transparent to operators. Other gotten benefits had been operational security, quality in the supply of electric energy and costs reduction. The project presented is a new solution, designed to substations and general applications where few data should be transmitted, but there is difficulties in relation to the media. Despite the satellite having been used, the same resulted can be gotten using celullar telephony, through Short Messages or packet networks as GPRS or EDGE.
Resumo:
This work purposes the application of a methodology to optimize the implantation cost of an wind-solar hybrid system for oil pumping. The developed model is estimated the implantation cost of system through Multiple Linear Regression technique, on the basis of the previous knowledge of variables: necessary capacity of storage, total daily energy demand, wind power, module power and module number. These variables are gotten by means of sizing. The considered model not only can be applied to the oil pumping, but also for any other purposes of electric energy generation for conversion of solar, wind or solar-wind energy, that demand short powers. Parametric statistical T-student tests had been used to detect the significant difference in the average of total cost to being considered the diameter of the wind, F by Snedecor in the variance analysis to test if the coefficients of the considered model are significantly different of zero and test not-parametric statistical by Friedman, toverify if there is difference in the system cost, by being considered the photovoltaic module powers. In decision of hypothesis tests was considered a 5%-significant level. The configurations module powers showed significant differences in total cost of investment by considering an electrical motor of 3 HP. The configurations module powers showed significant differences in total cost of investment by considering an electrical motor of 5 HP only to wind speed of 4m/s and 6 m/s in wind of 3 m, 4m and 5 m of diameter. There was not significant difference in costs to diameters of winds of 3 m and 4m. The mathematical model and the computational program may be used to others applications which require electrical between 2.250 W and 3.750 W. A computational program was developed to assist the study of several configurations that optimizes the implantation cost of an wind-solar system through considered mathematical model
Resumo:
This work verifies the impact caused by the Emergencial Program of Reduction of Consumption of Electric Energy (energy-rationing program) in the results of the concessionary private companies of the public service of electric energy distribution localized in the Northeast Area. As the rationing invigorated from June 2001 to February 2002, its effects are diluted in the results presented by these companies in the second semester of 2001 and first quarter of 2002, with prominence for the last quarter of 2001, when the revenue of extraordinary tariff restore was instituted by the National Agency of Electric Energy (ANEEL), consequence of the so-called General Agreement of the Electric Sector made between the federal government and the companies of the electric sector. The structure of a generic electric sector and a historical review of the Brazilian electric sector from the time it was controlled by the private enterprises, including the State control period, about 1960, and returning to the control of the private enterprises in 1990, under a new regulation structure are presented. An explanation of the models of economic regulation that Brazil used for the electric sector is made, with prominence for the price cap that is the actual effective model. The process of tariff revision foreseen in the concession contracts signed by the federal government and the concessionary companies is presented, highlighting its two stages: the tariff rebalancing that defines the new price cap and the calculation of the factor X that establishes the efficiency goals for the companies. There is made a presentation of the Emergencial Program of Reduction of Consumption of Electric Energy and of the consequent General Agreement of the Electric Sector, which created the revenue of extraordinary tariff restore. A conceptual revision on reviews is presented, regarding to concepts, accomplishment and recognition. A brief review of the six companies that made part of the worked sample is also presented. Analyzing the quarters historical review and of amount of sold energy, it was possible to conclude that the energy-rationing altered the results of the studied companies significantly and that alteration was masked by the accounting process of the revenue of extraordinary tariff restore
Resumo:
This paper addresses the theme of retrotif applied to buildings that belong to the modernist architectural production of historical interest located in the urban area of Natal . The overall objective is to identify and harmonize procedures for retrofit and architectural heritage preservation using elements of constructive analysis of expression and Benefit Cost Ratio ( BCR ) parameters established by the National Electric Energy Agency - ANEEL . The hypothesis put forward is that by stimulating the projetual year analysis , retrofit interventions , it is possible to obtain better results with projects RCB addressing the issues of preservation of architectural heritage . For both flow analysis of process solutions and proposals for action of elements and systems that seek to improve the energy performance of the building , restoring or preserving the architectural elements were developed . The proposed interventions undergo performance through computer simulations of systems such as DesignBuilder, Solar and Sun Tool. The energy results were converted to the analysis of RCB parameter and compared to the constructive expression of the project because the prenatal and intervention. From the results , a plot was constructed which results in a comparison between the RCB and the constructive expression of the simulated interventions
Resumo:
The growing need for food is something that worries the world, which has a population that is growing at a geometric progression while their resources grows at an arithmetic progression. To alleviate this problem there are some proposals, including increased food production or reduce waste thereof. Many studies have been conducted in the world in order to reduce food waste that can reach 40% of production, depending on the region. For this purpose techniques are used to retard degradation of foods, including drying. This paper presents a design of a hybrid fruit dryer that uses solar energy and electric energy with automation of the process. To accomplish drying tests were chosen Typical fruits with good acceptability as processed fruits. During the experiments were measured temperature values at different points. Were also measured humidity values, solar radiation and mass. A data acquisition system was built using a Arduino for obtaining temperatures. The data were sent to a program named Secador de Frutas, done in this work, to plot the same. The volume of the drying chamber was 423 liters and despite the unusual size test using mirrors to increase the incidence of direct radiation, showed that the drier is competitive when compared with other solar dryers produced in Hydraulic Machines and Solar Energy Laboratory (LMHES ) UFRN. The drier has been built at a cost of 3 to 5 times smaller than industrial dryers that operate with the same load of fruit. And the energy cost to produce dried fruits was more feasible compared with such dryers that use LPG as an energy source. However, the drying time was longer.
Resumo:
In Brazil, the National Agency of Electric Energy (ANEEL) represents the energy regulator. The rates review have been one of its main tasks, which establish a pricing practice at a level to cover the efficient operating costs and also the appropriate return of the distributors investments. The changes in the procedures to redefine the efficient costs and the several studies on the methodologies employed to regulate this segment denote the challenge faced by regulators about the best methodological strategy to be employed. In this context, this research aims to propose a benchmarking evaluation applied to the national regulation system in the establishment of efficient operating costs of electricity distribution utilities. The model is formulated to promote the electricity market development, partnering with government policies ant to society benefit. To conduct this research, an integration of Data Envelopment Analysis (DEA) with the Stochastic Frontier Analysis (SFA) is adopted in a three stages procedure to correct the efficiency in terms of environmental effects: (i) evaluation by means of DEA to measure operating costs slacks of the utilities, in which environmental variables are omitted; (ii) The slacks calculated in the first stage are regressed on a set of environmental variables by means of SFA and operating costs are adjusted to account the environmental impact and statistical noise effects; and, (iii) reassess the performance of the electric power distribution utilities by means of DEA. Based on this methodology it is possible to obtain a performance evaluation exclusively expressed in terms of management efficiency, in which the operating environment and statistical noise effects are controlled.
Resumo:
Cells the solid oxide fuel are systems capable to directly convert energy of a chemical reaction into electric energy in clean, quiet way and if its components in the solid state differentiate of excessively the techniques for having all. Its more common geometric configurations are: the tubular one and to glide. Geometry to glide beyond the usual components (anode, cathode and electrolyte) needs interconnect and sealant. E the search for materials adjusted for these components is currently the biggest challenge found for the production of the cells. The sealants need to present chemical stability in high temperatures, to provoke electric isolation, to have coefficient of compatible thermal expansion with the excessively component ones. For presenting these characteristics the glass-ceramics materials are recommended for the application. In this work the study of the partial substitution of the ZrO2 for the Al2O3 in system LZS became it aiming at the formation of system LZAS, this with the addition of natural spodumene with 10, 20 and 30% in mass. The compositions had been casting to a temperature of 1500°C and later quickly cooled with the objective to continue amorphous. Each composition was worn out for attainment of a dust with average diameter of approximately 3μm and characterized by the techniques of DRX, FRX, MEV, dilatometric analysis and particle size analysis. Later the samples had been conformed and treated thermally with temperatures in the interval between 700-1000 °C, with platform of 10 minutes and 1 hour. The analyses for the treated samples had been: dilatometric analysis, DRX, FRX, electrical conductivity and tack. The results point with respect to the viability of the use of system LZAS for use as sealant a time that had presented good results as isolating electric, they had adhered to a material with similar α of the components of a SOFC and had presented steady crystalline phases