9 resultados para Reprimido-icc

em Universidade Federal do Rio Grande do Norte(UFRN)


Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study aimed at assessing the interobserver reliability of the Brazilian-Portuguese version of the Berg Balance Scale (BBS). The assessment was made by physiotherapists with extensive or little clinical experience in non-institutionalized elderly individuals. Participants comprised 12 elderly subjects (10 women and 2 men) with mean ages of 75.8 ± 8.4 years (range = 63-87) and 18 physiotherapists with varying clinical experience. Inter-examiner reliability obtained for each scale item yielded weighted kappa value > 0.75 in 11 of the 14 items (varying from 0.37 to 1.0). The intra-class correlation coefficient (ICC) for the total sum of BBS scores between the two groups of physiotherapists was 0.996 (95% confidence interval, 0.987 0.999) with a Cronbach alpha coefficient of 0.996. We found no difference between the rater groups when we compared the sum score means obtained with the student s T-test (p = 0.86). Although some items had low reliability values, in general our results suggest that the Brazilian Version of the BBS showed good levels of interrater reliability and agreement when used by physiotherapists with different clinical practice levels and without previous training on non-institutionalized elderly patients. We concluded that the BBS can be useful as an important evaluation instrument on a protocol for Rehabilitation clinics. It may be used by various health professionals, as: Physicians, Physical therapists, Physical educators, Occupational therapists, Nurses and Phonoaudiologists, so confirming the interdisciplinary character of this study

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: Chagas Disease is a serious public health problem, with 5 million infected individuals in Brazil. Of these, approximately 30% develop chronic Chagas cardiomyopathy (CCC), where the main symptoms are fatigue and dyspnea. Objective: To correlate maximal exercise capacity with pulmonary function, inspiratory muscle strength and quality of life in patients with CCC. Methodology: Twelve individuals suffering from CCC were evaluated (7 men), with a mean age of 54.91± 8.60 years and the following inclusion criteria: functional class II and III according to the New York Heart Association (NYHA); left ventricle ejection fraction below 45%; clinical stability (> 3 months); symptom duration > 1 year, body mass index (BMI) < 35Kg/m2 and non-smokers or ex-smokers with a history of smoking <10 packs/day. All subjects were submitted to spirometry, manometer testing, maximal cardiopulmonary exercise testing (CPX) and a quality of life questionnaire (Minnesota). Results: A negative correlation was observed between VO2máx and MLHFQ scores (r=-0.626; p=0.03) and a positive association with MIP (r=0.713; p=0.009). Positive correlations were also recorded between MIP and spirometric variables [FEV1(r=0.825;p=0.001 ), FVC(r=0.66;p=0.01 and FEF25-75%(r=0.639;p=0.02)]. Conclusion: The present study demonstrated that in patients with CCC: VO2MAX is directly related to inspiratory muscle strength and quality of life, while deteriorating lung function is directly associated with respiratory muscle weakness

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The Brain-Computer Interfaces (BCI) have as main purpose to establish a communication path with the central nervous system (CNS) independently from the standard pathway (nervous, muscles), aiming to control a device. The main objective of the current research is to develop an off-line BCI that separates the different EEG patterns resulting from strictly mental tasks performed by an experimental subject, comparing the effectiveness of different signal-preprocessing approaches. We also tested different classification approaches: all versus all, one versus one and a hierarchic classification approach. No preprocessing techniques were found able to improve the system performance. Furthermore, the hierarchic approach proved to be capable to produce results above the expected by literature

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introdução: The scales of cognitive screening are important tools for early detection of dementia, creating the possibility of developing measures to slow this process and assist in the management of the disease. Objective: To validate the Leganés Cognitive Test (Prueba Cognitive de Leganés) (PCL) for cognitive screening in low educated elderly Brazilians. Methods: The study sample was composed of 59 elderly residents from the city of Santa Cruz, Brazil with low schooling levels. Reliability was analyzed with a 2-day interval between assessments, and concurrent validity was assessed using the Mini Mental State Examination (MMSE). Results: According to the PCL, the prevalence of dementia was 11.8%. The scale items showed a moderate to strong correlation between domains (p <0.01), and inter-rater reliability exhibited ICC = 0.81, 95% CI (0.72-0.88). Factor analysis resulted in two factors: memory and orientation. Interscale agreement was considered poor (k = - 0.02), supporting the hypothesis of an educational impact on final MMSE scores. Conclusion: The results suggest that PCL has acceptable levels of reliability for use in low educated elderly Brazilians

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives: to translate and assess the psychometric properties of the Brazilian short-form of the Mobility Assessment Tool (MAT-sf) in Brazilians community elderly. Methds: the 12 items MAT-sf went through the process of translation and back translation into Portuguese of the Brazil, considering the semantic and cultural adaptation. In a sample of 150 aged 65-74 years living in the community, the instrument's psychometric properties were evaluated by analysis of convergent and construct validity and test-retest reliability. The main outcomes measures used for validation included in the battery of tests of physical ability, self-repor measures of functional limitations, health, depression, cognitive and sex. The test-retest reliability of the instrument was assessed using the intra-class correlation coefficient (ICC), 40 subjects were reassessed after an interval of 14 days of assessment. Results: the concurrent validity for the MAT-sf was evidenced by significant correlations with SPPB (r = 0,53), number of functional limitations (r = -0,62) and depressive symptoms (r = -0,45). The construct validity of the instrument was measured by gradual and significant increase of the MAT-sf scores with high levels of physical performance and with positive self-reported health, also found that MAT-sf scores were statistically differents according to sex. The variation in MAT-sf scores (R2 = 0,41) was explained by SPPB, number of limitations for activities of daily life and depressive symptoms. High values for test-retest reliability was evidencend by ICC = 0,94, 95% CI = 0,90 0,97. Conclusions: the Brazilian version of the short-form of the Mobility Assessment Tool has values of validity and reliability to ensure its use in elderly populations living in communities

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The Wii Balance Board (WBB) began to be investigated as a low-cost alternative for assessing static balance in vertical posture. However, studies employed methodological procedures that did not eliminate result variability between the tests and equipment used. Objective: Determine the validity and reproducibility of the WBB as an instrument for assessing static balance in the vertical position, using simultaneous data analysis and superimposed equipment. Methods: This is an accuracy study of 29 healthy young individuals of both sexes aged 18 to 30 years. Subjects were assessed 24h apart (test-retest), using unipodal and bipodal support tests, with eyes closed and open. To that end the WBB was placed on top of a force platform (FP) and data (postural sway) were collected simultaneously on both devices. Validity and reproducibility were analyzed using the interclass correlation coefficient (ICC). Finally, Bland-Altman analysis was applied to assess agreement. Results: The sample was composed of 23 women and 6 men, with mean age of 24.2±6.3 years, 60.7±6.3 kg and 1.64±4.2 m. The validity of the WBB compared to the FP was excellent for all 4 tasks proposed (ICC = 0.93 0.98). The reproducibility analyzed by test-retest was excellent for the bipodal support tasks (ICC = 0.93-0.98) and only moderate for the unipodal support tests (ICC = 0.46 0.70). Graphic analysis exhibited good agreement between the devices, since most of the measures were within the limits of agreement. Conclusion: this study proved the validity and reproducibility of the Wii Balance Board as an instrument for assessing static balance in vertical posture, using simultaneous analysis with superimposed equipment. Thus, the WBB has been increasingly used by physical therapists and other health professionals in their clinical practice, as both a rehabilitation and assessment tool

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The calculation of tooth mass discrepancy, essential for good planning and a proper orthodontic finishing, when performed manually, besides being laborious, requires considerable time consumption. The aim of this study was to develop and test Bolton Freeware, a software for analysis of the tooth mass discrepancy of Bolton, aiming to minimize the consumption of time in a less onerous way. The digital analysis of the software was done by means of two-dimensional scanning of plaster study models and compared to manual evaluation (gold standard), using 75 pairs of stone plaster study models divided into two groups according to the magnitude of the Curve of Spee (group I from 0 to 2 mm, group II greater than 2 to 3mm). All the models had permanent dentition and were in perfect condition. The manual evaluation was performed with a digital caliper and a calculator, and the time required to perform the analysis for both methods was recorded and compared. In addition, the software was evaluated by orthodontists regarding its use, by means of questionnaires developed specifically for this purpose. Calibration was performed prior to manual analysis, and excellent levels of inter-rater agreement were achieved, with ICC > 0.75 and r > 0.9 for total and anterior proportion. It was observed in the evaluation of error of the digital method that some teeth showed a significant systematic error, being the highest measured at 0.08 mm. The analysis of total tooth mass discrepancy performed by Bolton Freeware, for those cases in which the curve of Spee is mild and moderate, differ from manual analysis, on average, 0.09 mm and 0.07 mm respectively, for each tooth evaluated, with r> 0, 8 for total and anterior proportion. According to the specificity and sensitivity test, Bolton Freeware has an improved ability to detect true negatives, i.e. the presence of discrepancy. The Bolton analysis digitally performed was faster, with an average difference of time consumed to perform the analysis of Bolton between the two methods of approximately 6 minutes. Most experts interviewed (93%) approved the usability of the software

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior