101 resultados para Pinning force


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Forces generated by polymerizing/de-polymerizing actin filaments confined between two mica surfaces were measured using the Surface Forces Apparatus. The measurements show that confined actin filaments exhibit complex force-generation dynamics involving multiple “modes”, the predominance of which is determined by the confinement gap and the applied force (confining pressure).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study assessed the validity of a tri-axial accelerometer worn on the upper body to estimate peak forces during running and change-of-direction tasks. Seventeen participants completed four different running and change-of-direction tasks (0°, 45°, 90°, and 180°; five trials per condition). Peak crania-caudal and resultant acceleration was converted to force and compared against peak force plate ground reaction force (GRF) in two formats (raw and smoothed). The resultant smoothed (10 Hz) and crania-caudal raw (except 180°) accelerometer values were not significantly different to resultant and vertical GRF for all running and change-of-direction tasks, respectively. Resultant accelerometer measures showed no to strong significant correlations (r = 0.00–0.76) and moderate to large measurement errors (coefficient of variation [CV] = 11.7–23.9%). Crania-caudal accelerometer measures showed small to moderate correlations (r = − 0.26 to 0.39) and moderate to large measurement errors (CV = 15.0–20.6%). Accelerometers, within integrated micro-technology tracking devices and worn on the upper body, can provide a relative measure of peak impact force experienced during running and two change-of-direction tasks (45° and 90°) provided that resultant smoothed values are used.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Noncovalent recognition between peptides and inorganic materials is an established phenomenon. Key to exploiting these interactions in a wide range of materials self-assembly applications would be to harness the facet-selective control of peptide binding onto these materials. Fundamental understanding of what drives facet-selectivity in peptide binding is developing, but as yet is not sufficient to enable design of predictable facet-specific sequences. Computational simulation of the aqueous peptide-gold interface, commonly used to understand the mechanisms driving adsorption at an atomic level, has thus far neglected the role that surface reconstruction might play in facet specificity. Here the polarizable GolP-CHARMM suite of force fields is extended to include the reconstructed Au(100) surface. The force field, compatible with the bio-organic force field CHARMM, is parametrized using first-principles data. Our extended force field is tailored to reproduce the heterogeneity of weak chemisorbing N and S species to specific locations in the Au(100)(5 × 1) surface identified from the first-principles calculations. We apply our new model to predict and compare the three-dimensional structure of liquid water at Au(111), Au(100)(1 × 1), and Au(100)(5 × 1) interfaces. Using molecular dynamics simulations, we predict an increased likelihood for water-mediated peptide adsorption at the aqueous-Au(100)(1 × 1) interface compared with the Au(100)(5 × 1) interface. Therefore, our findings suggest that peptide binding can discriminate between the native and reconstructed Au(100) interfaces and that the role of reconstruction on binding at the Au(100) interface should not be neglected. © 2013 American Chemical Society.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An automated laparoscopic instrument capable of non-invasive measurement of tip/tissue interaction forces for direct application in robotic assisted minimally invasive surgery systems_ is introduced in this paper. It has the capability to measure normal grasping forces as well as lateral interaction forces without any sensor mounted on the tip jaws. Further to non-invasive actuation of the tip, the proposed instrument is also able to change the grasping direction during surgical operation. Modular design of the instrument allows conversion between surgical modalities (e.g., grasping, cutting, and dissecting). The main focus of this paper is on evaluation of the grasping force capability of the proposed instrument. The mathematical formulation of fenestrated insert is presented and its non-linear behaviour is studied. In order to measure the stiffness of soft tissues, a device was developed that is also described in this paper. Tissue characterisation experiments were conducted and results are presented and analysed here. The experimental results verify the capability of the proposed instrument in accurately measuring grasping forces and in characterising artificial tissue samples of varying stiffness.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives:  Via an international panel of experts, this paper attempts to document, review, interpret, and propose operational definitions used to describe the course of bipolar disorders for worldwide use, and to disseminate consensus opinion, supported by the existing literature, in order to better predict course and treatment outcomes. Methods:  Under the auspices of the International Society for Bipolar Disorders, a task force was convened to examine, report, discuss, and integrate findings from the scientific literature related to observational and clinical trial studies in order to reach consensus and propose terminology describing course and outcome in bipolar disorders. Results:  Consensus opinion was reached regarding the definition of nine terms (response, remission, recovery, relapse, recurrence, subsyndromal states, predominant polarity, switch, and functional outcome) commonly used to describe course and outcomes in bipolar disorders. Further studies are needed to validate the proposed definitions. Conclusion:  Determination and dissemination of a consensus nomenclature serve as the first step toward producing a validated and standardized system to define course and outcome in bipolar disorders in order to identify predictors of outcome and effects of treatment. The task force acknowledges that there is limited validity to the proposed terms, as for the most part they represent a consensus opinion. These definitions need to be validated in existing databases and in future studies, and the primary goals of the task force are to stimulate research on the validity of proposed concepts and further standardize the technical nomenclature.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

ABB has written a new chapter in the book of robot applications. While in the past it had been a tedious and time-consuming effort to program a robot for delicate fine-tuning operations, robots can now learn how to best manage such tasks themselves. This innovative approach can reduce overall programming times by up to 80 percent for robots used to grind castings, vastly improving productivity levels. With ABB’s new Flex Finishing system featuring RobotWare Machining FC (force control), one of the last real barriers to productivity improvement in this sector has been lifted.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We discuss the rationale behind staging systems described specifically for bipolar disorders. Current applications, future directions and research gaps in clinical staging models for bipolar disorders are outlined.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Magnetic force microscopy (MFM) signals have recently been detected from whole pieces of mechanically exfoliated graphene and molybdenum disulfide (MoS2) nanosheets, and magnetism of the two nanomaterials was claimed based on these observations. However, non-magnetic interactions or artefacts are commonly associated with MFM signals, which make the interpretation of MFM signals not straightforward. A systematic investigation has been done to examine possible sources of the MFM signals from graphene and MoS2 nanosheets and whether the MFM signals can be correlated with magnetism. It is found that the MFM signals have significant non-magnetic contributions due to capacitive and electrostatic interactions between the nanosheets and conductive cantilever tip, as demonstrated by electric force microscopy and scanning Kevin probe microscopy analyses. In addition, the MFM signals of graphene and MoS2 nanosheets are not responsive to reversed magnetic field of the magnetic cantilever tip. Therefore, the observed MFM response is mainly from electric artefacts and not compelling enough to correlate with magnetism of graphene and MoS2 nanosheets.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cooperative control of multiple mobile robots is an attractive and challenging problem which has drawn considerable attention in the recent past. This paper introduces a scalable decentralized control algorithm to navigate a group of mobile robots (swarm) into a predefined shape in 2D space. The proposed architecture uses artificial forces to control mobile agents into the shape and spread them inside the shape while avoiding intermember collisions. The theoretical analysis of the swarm behavior describes the motion of the complete swarm and individual members in relevant situations. We use computer simulated case studies to verify the theoretical assertions and to demonstrate the robustness of the swarm under external disturbances such as death of agents, change of shape etc. Also the performance of the proposed distributed swarm control architecture was investigated in the presence of realistic implementation issues such as localization errors, communication range limitations, boundedness of forces etc.