Resumo:
A small break loss-of-coolant accident (SBLOCA) is one of problems investigated in an NPP operation. Such accident can be analyzed using an experiment facility and TRACE thermal-hydraulic system code. A series of SBLOCA experiments was carried out on Parallel Channel Test Loop (PACTEL) facility, exploited together with Technical Research Centre of Finland VTT Energy and Lappeenranta University of Technology (LUT), in order to investigate two-phase phenomena related to a VVER-type reactor. The experiments and a TRACE model of the PACTEL facility are described in the paper. In addition, there is the TRACE code description with main field equations. At the work, calculations of a SBLOCA series are implemented and after the calculations, the thesis discusses the validation of TRACE and concludes with an assessment of the usefulness and accuracy of the code in calculating small breaks.
Resumo:
Currently, the power generation is one of the most significant life aspects for the whole man-kind. Barely one can imagine our life without electricity and thermal energy. Thus, different technologies for producing those types of energy need to be used. Each of those technologies will always have their own advantages and disadvantages. Nevertheless, every technology must satisfy such requirements as efficiency, ecology safety and reliability. In the matter of the power generation with nuclear energy utilization these requirements needs to be highly main-tained, especially since accidents on nuclear power plants may cause very long term deadly consequences. In order to prevent possible disasters related to the accident on a nuclear power plant strong and powerful algorithms were invented in last decades. Such algorithms are able to manage calculations of different physical processes and phenomena of real facilities. How-ever, the results acquired by the computing must be verified with experimental data.
Resumo:
The purpose of this thesis is to study the scalability of small break LOCA experiments. The study is performed on the experimental data, as well as on the results of thermal hydraulic computation performed on TRACE code. The SBLOCA experiments were performed on PACTEL facility situated at LUT. The temporal scaling of the results was done by relating the total coolant mass in the system with the initial break mass flow and using the quotient to scale the experiment time. The results showed many similarities in the behaviour of pressure and break mass flow between the experiments.
Resumo:
The behavior of the nuclear power plants must be known in all operational situations. Thermal hydraulics computer applications are used to simulate the behavior of the plants. The computer applications must be validated before they can be used reliably. The simulation results are compared against the experimental results. In this thesis a model of the PWR PACTEL steam generator was prepared with the TRAC/RELAP Advanced Computational Engine computer application. The simulation results can be compared against the results of the Advanced Process Simulator analysis software in future. Development of the model of the PWR PACTEL vertical steam generator is introduced in this thesis. Loss of feedwater transient simulation examples were carried out with the model.
Resumo:
Diplomityössä kartoitetaan mahdollisuuksia aukko-osuuden mittaamiseksi ydinvoimalaitosta mallintavan PWR PACTEL -koelaitteiston pystyhöyrystimen sekundääripuolella. Työ on toteutettu osana kansallista SAFIR2014-ydinturvallisuustutkimusohjelmaa. Diplomityön tavoitteena on löytää kustannuksiltaan mahdollisimman järkevä ja toimiva menetelmä aukko-osuuden määrittämiseksi. Aukko-osuuden mittaaminen on tärkeää sekundääripuolen kaksifaasivirtauksen käyttäytymisen paremman tuntemuksen lisäämiseksi. Aukko-osuusmittausdataa tarvitaan muun muassa laskentakoodien validointiin. Diplomityössä perehdytään kaksifaasivirtauksen ja aukko-osuuden fysiikkaan sekä esitellään erityyppisiä aukko-osuuden mittausmenetelmiä. Kunkin mittausmenetelmän soveltuvuutta PWR PACTEL -koelaitteistoon arvioidaan erikseen. Aukko-osuuden mittaaminen höyrystimen sekundääripuolella osoittautuu käytännössä erittäin hankalaksi. Pääasiassa tämä johtuu höyrystimen rakenteesta sekä mittausmenetelmien korkeista kustannuksista. Tämän vuoksi työssä tarkastellaan myös edellytyksiä aukko-osuuden mittaamiselle erillisessä höyrystintä mallintavassa koelaitteistossa. Mikäli aukko-osuutta haluttaisiin mitata erilliskoelaitteistossa, tulisi höyrystinmallin rakennetta, materiaaleja tai kiertoainetta muuttaa PWR PACTELin höyrystimeen verrattuna.
Resumo:
Diplomityössä selvitetään PWR PACTEL -koelaitteiston APROS-mallin ylätilan toimi¬vuut¬ta ja tutkitaan tapoja parantaa mallin simulointitarkkuutta. Työssä on esitelty PWR PACTEL -koelaitteiston sekä APROS-simulointiohjelman pääpiirteet ja tutustuttu simu¬loin¬ti¬ohjelmien kelpoistukseen. Simulointiosiossa tarkastellaan yksinkertaisen ja muokatun ylätilamallin toimivuutta ver¬taa¬mal¬la simulointia koelaitteistolla tehtyjen kokeiden mittaustuloksiin. Lisäksi tutkitaan nel¬¬jää tapaa parantaa ylätilamallin toimivuutta: virtausvastusten säätö, lämpöhäviöiden sä䬬tö, rakenteelliset muutokset ja laskentakorrelaatioiden vaihtaminen. Simulointituloksia ver¬¬ra¬¬taan kahteen koelaitteistolla suoritettuun kokeeseen, joista toinen on tasapainotilankoe ja toinen dynaamisen tilan koe. Työssä havaittiin, että nykyisin käytössä olevaa mallia on kehitetty jo varsin paljon, ver¬rat¬tu¬na ns. yksinkertaiseen malliin. Testatuilla parannusvaihtoehdoilla saatiin hieman paran¬net¬tua ylätilan lämpötilojen simulointia tasapainotilassa. Dynaamisen tilan osalta havaittiin pien¬tä parannusta mallin toiminnassa ylätilamallin rakennemuutosten jälkeen. Tulosten poh¬jalta arvioitiin, että mallia on mahdollista kehittää muuttamalla ylätilamallin raken¬net¬ta.
Resumo:
Diplomityön tavoitteena on paineistimen yksityiskohtainen mallintaminen APROS- ja TRACE- termohydrauliikkaohjelmistoja käyttäen. Rakennetut paineistinmallit testattiin vertaamalla laskentatuloksia paineistimen täyttymistä, tyhjentymistä ja ruiskutusta käsittelevistä erilliskokeista saatuun mittausdataan. Tutkimuksen päätavoitteena on APROSin paineistinmallin validoiminen käyttäen vertailuaineistona PACTEL ATWS-koesarjan sopivia paineistinkokeita sekä MIT Pressurizer- ja Neptunus- erilliskokeita. Lisäksi rakennettiin malli Loviisan ydinvoimalaitoksen paineistimesta, jota käytettiin turbiinitrippitransientin simulointiin tarkoituksena selvittää mahdolliset voimalaitoksen ja koelaitteistojen mittakaavaerosta johtuvat vaikutukset APROSin paineistinlaskentaan. Kokeiden simuloinnissa testattiin erilaisia noodituksia ja mallinnusvaihtoehtoja, kuten entalpian ensimmäisen ja toisen kertaluvun diskretisointia, ja APROSin sekä TRACEn antamia tuloksia vertailtiin kattavasti toisiinsa. APROSin paineistinmallin lämmönsiirtokorrelaatioissa havaittiin merkittävä puute ja laskentatuloksiin saatiin huomattava parannus ottamalla käyttöön uusi seinämälauhtumismalli. Työssä tehdyt TRACE-simulaatiot ovat osa United States Nuclear Regulatory Commissionin kansainvälistä CAMP-koodinkehitys-ja validointiohjelmaa.
Resumo:
Uusi EPR-reaktorikonsepti on suunniteltu selviytymään tapauksista, joissa reaktorinsydän sulaa ja sula puhkaisee paineastian. Suojarakennuksen sisälle on suunniteltu alue, jolle sula passiivisesti kerätään, pidätetään ja jäähdytetään. Alueelle laaditaan valurautaelementeistä ns.sydänsieppari, joka tulvitetaan vedellä. Sydänsulan tuottama jälkilämpö siirtyyveteen, mistä se poistetaan suojarakennuksen jälkilämmönpoistojärjestelmän kautta. Suuri osa lämmöstä poistuu sydänsulasta sen yläpuolella olevaan veteen, mutta lämmönsiirron tehostamiseksi myös sydänsiepparin alapuolelle on sijoitettu vedellä täytettävät jäähdytyskanavat. Jotta sydänsiepparin toiminta voitaisiin todentaa, on Lappeenrannan Teknillisellä Yliopistolla rakennettu Volley-koelaitteisto tätä tarkoitusta varten. Koelaitteisto koostuu kahdesta täysimittaisesta valuraudasta tehdystä jäähdytyskanavasta. Sydänsulan tuottamaa jälkilämpöä simuloidaan koelaitteistossa sähkövastuksilla. Tässä työssä kuvataan simulaatioiden suorittaminen ja vertaillaan saatuja arvoja mittaustuloksiin. Työ keskittyy sydänsiepparista jäähdytyskanaviin tapahtuvan lämmönsiirron teoriaan jamekanismeihin. Työssä esitetään kolme erilaista korrelaatiota lämmönsiirtokertoimille allaskiehumisen tapauksessa. Nämä korrelaatiot soveltuvat erityisesti tapauksiin, joissa vain muutamia mittausparametreja on tiedossa. Työn toinen osa onVolley 04 -kokeiden simulointi. Ensin käytettyä simulointitapaa on kelpoistettuvertaamalla tuloksia Volley 04 ja 05 -kokeisiin, joissa koetta voitiin jatkaa tasapainotilaan ja joissa jäähdytteen käyttäytyminen jäähdytyskanavassa on tallennettu myös videokameralla. Näiden simulaatioiden tulokset ovat hyvin samanlaisiakuin mittaustulokset. Korkeammilla lämmitystehoilla kokeissa esiintyi vesi-iskuja, jotka rikkoivat videoinnin mahdollistavia ikkunoita. Tämän johdosta osassa Volley 04 -kokeita ikkunat peitettiin metallilevyillä. Joitakin kokeita jouduttiin keskeyttämään laitteiston suurten lämpöjännitysten johdosta. Tällaisten testien simulaatiot eivät ole yksinkertaisia suorittaa. Veden pinnan korkeudesta ei ole visuaalista havaintoa. Myöskään jäähdytteen tasapainotilanlämpötiloista ei ole tarkkaa tietoa, mutta joitakin oletuksia voidaan tehdä samoilla parametreilla tehtyjen Volley 05 -kokeiden perusteella. Mittaustulokset Volley 04 ja 05 -kokeista, jotka on videoitu ja voitu ajaa tasapainotilaan saakka, antoivat simulaatioiden kanssa hyvin samankaltaisia lämpötilojen arvoja. Keskeytettyjen kokeiden ekstrapolointi tasapainotilaan ei onnistunut kovin hyvin. Kokeet jouduttiin keskeyttämään niin paljon ennen termohydraulista tasapainoa, ettei tasapainotilan reunaehtoja voitu ennustaa. Videonauhoituksen puuttuessa ei veden pinnan korkeudesta saatu lisätietoa. Tuloksista voidaan lähinnä esittää arvioita siitä, mitä suuruusluokkaa mittapisteiden lämpötilat tulevat olemaan. Nämä lämpötilat ovat kuitenkin selvästi alle sydänsiepparissa käytettävän valuraudan sulamislämpötilan. Joten simulaatioiden perusteella voidaan sanoa, etteivät jäähdytyskanavien rakenteet sula, mikäli niissä on pienikin jäähdytevirtaus, eikä useampia kuin muutama vierekkäinen kanava ole täysin kuivana.
Resumo:
The present study focuses on two effects of the presence of a noncondensable gas on the thermal-hydraulic behavior of thecoolant of the primary circuit of a nuclear reactor in the VVER-440 geometry inabnormal situations. First, steam condensation with the presence of air was studied in the horizontal tubes of the steam generator (SG) of the PACTEL test facility. The French thermal-hydraulic CATHARE code was used to study the heat transfer between the primary and secondary side in conditions derived from preliminary experiments performed by VTT using PACTEL. In natural circulation and single-phase vapor conditions, the injection of a volume of air, equivalent to the totalvolume of the primary side of the SG at the entrance of the hot collector, did not stop the heat transfer from the primary to the secondary side. The calculated results indicate that air is located in the second half-length (from the mid-length of the tubes to the cold collector) in all the tubes of the steam generator The hot collector remained full of steam during the transient. Secondly, the potential release of the nitrogen gas dissolved in the water of the accumulators of the emergency core coolant system of the Loviisa nuclear power plant (NPP) was investigated. The author implemented a model of the dissolution and release ofnitrogen gas in the CATHARE code; the model created by the CATHARE developers. In collaboration with VTT, an analytical experiment was performed with some components of PACTEL to determine, in particular, the value of the release time constant of the nitrogen gas in the depressurization conditions representative of the small and intermediate break transients postulated for the Loviisa NPP. Such transients, with simplified operating procedures, were calculated using the modified CATHARE code for various values of the release time constant used in the dissolution and release model. For the small breaks, nitrogen gas is trapped in thecollectors of the SGs in rather large proportions. There, the levels oscillate until the actuation of the low-pressure injection pumps (LPIS) that refill the primary circuit. In the case of the intermediate breaks, most of the nitrogen gas is expelled at the break and almost no nitrogen gas is trapped in the SGs. In comparison with the cases calculated without taking into account the release of nitrogen gas, the start of the LPIS is delayed by between 1 and 1.75 h. Applicability of the obtained results to the real safety conditions must take into accountthe real operating procedures used in the nuclear power plant.
Resumo:
Ydinvoimalaitosten turvallisuusanalyysit tehdään nykyisin pääasiassa tietokoneohjelmistoilla. Turvallisuusanalyyseissä käytetyt ohjelmistot ja niillä tehdyt mallit pitää kelpoistaa, jotta mallilla saatuja tuloksia voidaan pitää luotettavina. PACTEL-koelaitteistolla tehdään turvallisuustutkimusta, joka palvelee erityisesti Loviisan VVER-440 -tyyppisiä voimalaitoksia. APROS-koodi kehitettiin Loviisan voimalaitoksen turvallisuusanalyysejä varten. Jotta APROS-koodi voitaisiin kelpoistaa rakennettiin PACTEL-koelaitteisto kokeellista termohydrauliikkatutkimusta varten. Koelaitteiston tuloksia käytettiin APROS ohjelmiston termohydraulisten mallien kehittämiseen. Vuonna 1999 aloitetun kansallisen FINNUS-projektin osatavoite on kehittää turvallisuustutkimuksissa käytettyjä tietokoneohjelmia, kuten APROSia. APROS on kehittynyt vuosien varrella niin laskenta-algoritmien kuin fysikaalisten mallienkin osalta. APROSiin oli kehitetty myös uusi käyttöliittymä GRADES, joka toimii Windows NT-ympäristössä. Diplomityön tavoitteena oli tehdä uudella GRADES-käyttöliittymällä uusi ja entistä tarkempi simulaatiomalli PACTEL-koelaitteistosta. Uusi simulaatiomalli kelpoistettiin kahden vanhan PACTEL-kokeen avulla, LOF-10 ja SBL-22. Laskentatuloksista voidaan päätellä laskeeko APROS oikein ja voidaanko APROSilla tehtyjä turvallisuusanalyysejä pitää luotettavina. Valmis kelpoistettu simulaatiomalli tuli VTT Energian kokeellisen lämpö- ja virtaustekniikan laboratorion käyttöön. Simulaatiomallilla voidaan laskea ja simuloida sekä vanhoja että uusia PACTEL-kokeita ja käyttää mallia tulevien PACTEL-kokeiden suunnitteluun.
Resumo:
Työn tarkoituksena on kerätä yhteen tiedot kaikista maailmalta löytyvistä ison LOCA:n ulospuhallusvaiheen tutkimiseen käytetyistä koelaitteistoista. Työn tarkoituksena on myös antaa pohjaa päätökselle, onko tarpeellista rakentaa uusi koelaitteisto nesterakenne-vuorovaikutuskoodien laskennan validoimista varten. Ennen varsinaisen koelaitteiston rakentamista olisi tarkoituksenmukaista myös rakentaa pienempi pilottikoelaitteisto, jolla voitaisiin testata käytettäviä mittausmenetelmiä. Sopivaa mittausdataa tarvitaan uusien CFD-koodien ja rakenneanalyysikoodien kytketyn laskennan validoimisessa. Näitä koodeja voidaan käyttää esimerkiksi arvioitaessa reaktorin sisäosien rakenteellista kestävyyttä ison LOCA:n ulospuhallusvaiheen aikana. Raportti keskittyy maailmalta löytyviin koelaitteistoihin, uuden koelaitteiston suunnitteluperusteisiin sekä aiheeseen liittyviin yleisiin asioihin. Raportti ei korvaa olemassa olevia validointimatriiseja, mutta sitä voi käyttää apuna etsittäessä validointitarkoituksiin sopivaa ison LOCA:n ulospuhallusvaiheen koelaitteistoa.
Resumo:
Diplomityössä tutkitaan virtauksen kääntymistä Lappeenrannan teknillisen yliopiston PWR PACTEL –koelaitteiston pystyhöyrystimen lämmönvaihtoputkissa käyttäen APROS–prosessisimulointiohjelmaa. Työn teoriaosassa esitellään pystyhöyrystimillä varustettuja koelaitteistoja, erityisesti PWR PACTEL ja sen höyrystin. Lisäksi esitellään virtauksen kääntymisestä tehtyjä havaintoja ja käsitellään kääntymistä teoreettisesta näkökulmasta. Simulointiosan alussa esitellään työssä käytetty APROS –prosessisimulointiohjelma, sekä sen avulla höyrystimestä luodut mallit. Työssä on tutkittu virtauksen käännöstapahtumaa simuloimalla useita eri transienttitilanteita pienillä primäärimassavirroilla. Simulaatiotapauksissa havaittiin virtauksen kääntyvän höyrystimen eripituisissa lämmönvaihtoputkissa, tilanteesta riippuen pääosin lyhimmissä tai toisiksi lyhimmissä lämmönvaihtoputkissa. Transienttien eri vaiheiden, ts. primäärimassavirran muutos- ja tasaantumisvaiheiden pituuden havaittiin vaikuttavan siihen, minkä pituisissa putkissa kääntyminen tapahtuu ja missä järjestyksessä.
Resumo:
The focus of the research is on the derivation of the valid and reliable performance results regarding establishment and launching of the new full-scale industrial facility, considering the overall current conditions for the project realization in and out of Russia. The study demonstrates the process of the new facility concept development, with following perfor-mance calculation, comparative analyzes conduction, life-cycle simulations, performance indicators derivation and project`s sustainability evaluation. To unite and process the entire input parameters complexity, regards the interlacing between the project`s internal technical and commercial sides on the one hand, and consider all the specifics of the Russian conditions for doing business on the other hand, was developed the unique model for the project`s performance calculation, simulations and results representation. The complete research incorporates all corresponding data to substantiate the assigned facility`s design, sizing and output capacity for high quality and cost efficient ferrous pipe-line accessories manufacturing, as well as, demonstrates that this project could be suc-cessfully realized in current conditions in Russia and highlights the room for significant performance and sustainability improvements based on the indexes of the derived KPIs.
Resumo:
Tämän insinöörityön tarkoituksena oli luoda Insinööritoimisto Olof Granlund Oy:lle malliprojekti ilmanvaihtokoneen ohjauksen mahdollisesta sähköenergian säästöpotentiaalista. Insinöörityötä voidaan myöhemmin käyttää referenssinä tarjottaessa yrityksen palvelua asiakkaille energiakatselmointityössä kiinteistöihin, joissa on suuria ilmanvaihtokone-yksiköitä. Ensin työssä esitellään käytössä olevat, tutkittavat ilmanvaihtokoneet ja niiden toiminta. Sitten selvitetään ilmanvaihtolaitteiden ja niiden ohjauksen eri osien toiminta, sekä ohjausinformaatio, joka välittyy eri laitteiden välillä. Seuraavaksi työssä tutkitaan rakennusautomaation osuutta, sen hyötyä ja rakennetta kiinteistössä. Tämän jälkeen selvitetään hankkeen viranomaismääräykset. Sitten selvitetään, mistä koostuvat kustannukset ilmanvaihtokoneen ohjauksen uusimisessa. Lopuksi vielä tutkitaan, kuinka pitkä on tehtävän investoinnin takaisinmaksuaika, sekä mitkä ovat saneerauksen hiilidioksidi-päästövaikutukset. insinöörityön Lopputuloksena syntyi yrityksen sisäinen kansio. Kansion esimerkkilaskelmia ja laskentamenetelmiä on tarkoitus käyttää jatkossa referenssinä kiinteistönpito-osastolla sähkö- ja lvi-ryhmissä, niiden henkilöiden käytössä, jotka ovat tekemisissä energiakatselmointien kanssa.
Resumo:
Tässä työssä tutkitaan Merima Oy:n tuotantolaitoksen toimintaa ohjattavuusanalyysillä. Työn tarkoituksena on etsiä potentiaalisia kehityskohteita yrityksen tuotannosta. Yrityksen tuotanto on muutospaineessa ja se tarvitsee kvantitatiivista informaatiota kehityksen suunnannäyttäjäksi. Työ aloitettiin jalostamalla yrityksen tuotannonohjausjärjestelmästä saatava data analysoitavaan muotoon. Tämän jälkeen päätettiin analyysityypeistä, joita työssä käytetään. Analyysivaiheessa jalostettu data saatettiin informoivaan muotoon, jonka jälkeen voitiin analysoida tuloksia ja tehdä johtopäätöksiä. Työn tuloksena saadaan joukko kehityskohteita, joihin kehityspanos tulisi fokusoida. Lisäksi raportin lopussa pohditaan keinoja kehityskohteiden parantamiseksi.