80 resultados para utility measurement


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This thesis presents the calibration and comparison of two systems, a machine vision system that uses 3 channel RGB images and a line scanning spectral system. Calibration. is the process of checking and adjusting the accuracy of a measuring instrument by comparing it with standards. For the RGB system self-calibrating methods for finding various parameters of the imaging device were developed. Color calibration was done and the colors produced by the system were compared to the known colors values of the target. Software drivers for the Sony Robot were also developed and a mechanical part to connect a camera to the robot was also designed. For the line scanning spectral system, methods for the calibrating the alignment of the system and the measurement of the dimensions of the line scanned by the system were developed. Color calibration of the spectral system is also presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aims:This study was carried out to evaluate the feasibility of two different methods to determine free flap perfusion in cancer patients undergoing major reconstructive surgery. The hypotheses was that low perfusion in the flap is associated with flap complications. Patients and methods: Between August 2002 and June 2008 at the Department of Otorhinolaryngology – Head and Neck Surgery, Department of Surgery, and at the PET Centre, Turku, 30 consecutive patients with 32 free flaps were included in this study. The perfusion of the free microvascular flaps was assessed with positron emission tomography (PET) and radioactive water ([15O] H2O) in 40 radiowater injections in 33 PET studies. Furthermore, 24 free flaps were monitored with a continuous tissue oxygen measurement using flexible polarographic catheters for an average of three postoperative days. Results: Of the 17 patients operated on for head and neck (HN) cancer and reconstructed with 18 free flaps, three re-operations were carried out due to poor tissue oxygenation as indicated by ptiO2 monitoring results and three other patients were reoperated on for postoperative hematomas in the operated area. Blood perfusion assessed with PET (BFPET) was above 2.0 mL / min / 100 g in all flaps and a low flap-to-muscle BFPET ratio appeared to correlate with poor survival of the flap. Survival in this group of HN cancer patients was 9.0 months (median, range 2.4-34.2) after a median follow-up of 11.9 months (range 1.0-61.0 months). Seven HN patients of this group are alive without any sign of recurrence and one patient has died of other causes. All of the 13 breast reconstruction patients included in the study are alive and free of disease at a median follow-up time of 27.4 months (range 13.9-35.7 months). Re-explorations were carried out in three patients due data provided by ptiO2 monitoring and one re-exploration was avoided on the basis of adequate blood perfusion assessed with PET. Two patients had donorsite morbidity and 3 patients had partial flap necrosis or fat necrosis. There were no total flap losses. Conclusions: PtiO2 monitoring is a feasible method of free flap monitoring when flap temperature is monitored and maintained close to the core temperature. When other monitoring methods give controversial results or are unavailable, [15O] H2O PET technique is feasible in the evaluation of the perfusion of the newly reconstructed free flaps.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Various strength properties of paper are measured to tell how well it resists breaks in a paper machine or in printing presses. The most often measured properties are dry tensile strength and dry tear strength. However, in many situations where paper breaks, it is not dry. For example, in web breaks after the wet pressing the dry matter content can be around 45%. Thus, wet-web strength is often a more critical paper property than dry strength. Both wet and dry strength properties of the samples were measured with a L&W tensile tester. Originally this device was not designed for the measurement of the wet web tensile strength, thus a new procedure to handle the wet samples was developed. The method was tested with Pine Kraft (never dried). The effect of different strength additives on the wet-web and dry paper tensile strength was studied. The polymers used in this experiment were aqueous solution of a cationic polyamidoamine-epichlorohydrin resin (PAE), cationic hydrophilised polyisocyanate and cationic polyvinylamine (PVAm). From all three used chemicals only Cationic PAE considerably increased the wet web strength. However it was noticed that at constant solids content all chemicals decreased the wet web tensile strength. So, since all chemicals enhanced solid content it can be concluded that they work as drainage aids, not as wet web strength additives. From all chemicals only PVAm increased the dry strength and two other chemicals even decreased the strength. As chemicals were used in strong diluted forms and were injected into the pulp slurry, not on the surface of the papersheets, changes in samples densities did not happen. Also it has to be noted that all these chemicals are mainly used to improve the wet strength after the drying of the web.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of the thesis was to create a performance measurement system for the logistics process of a company. In addition, one goal was to make suggestions for improvements based on description and analysis of the process and current measures. The logistics process was described in detail, and the objectives for it were derived from the company strategy and goals. Suggestions for performance measurement system and process improvement were made based on current state analysis. As a result of the thesis, three new performance measures were decided to take into use. In addition, several improvements were suggested to the ERP system to make process smoother. Some of the improvements have already been added to the system and the rest will be added in the near future.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this study is to create measurement system that is capable to measure performance in basic industry’s service centers. First it is examined what is performance and how it can be measured. The study also introduces commonly known measurement frameworks. After theory the study investigates how companies in the field of basic industry measure their operations in practise. The investigation is done examining three case examples and by analyzing survey results from basic industry companies. On the survey results focus is on what meters and measurement systems companies use. It is also viewed what measurement problems companies have faced. In the applied part of the study harmonized performance measurement system is created. The framework of the measurement system is introduced and measurement system for the target company is created. The target company felt that the harmonized performance measurement system has good potential and continues to develop it further.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

With the occurrence of fossil fuels such as oil, gas and coal we found new sources of energy that have played a critical role in the progress of our modern society. Coal is very ample compared to the other two fossil fuels. Global coal reserves at the end of 2005 were estimated at 847,5 billion tones. Along with the major energy sources, coal is the most fast growing fuel on a global basis, it provides 26% of primary energy needs and remains essential to the economies of many developed and developing countries. Coal-fired power generation accounts for 41% of the world‘s total electricity production and in some countries, such as South Africa, Poland, China, Australia, Kazakhstan and India is on very high level. Still, coal utilization represents challenges related to high emissions of air pollutants such as sulphur and nitrogen dioxides, particulate matter, mercury and carbon dioxide. In relation to these a number of technologies have been developed and are in marketable use, with further potential developments towards ―Near Zero Emission‖ coal plants. In present work, coals mined in Russia and countries of Former Soviet Union were reviewed. Distribution of coal reserves on the territory of Russia and the potential for power generation from coal-fired plants across Russia was shown. Physical and chemical properties of coals produced were listed and examined, as main factor influencing on design of the combustion facility and incineration process performance. The ash-related problems in coal-fired boilers were described. The analysis of coal ash of Russia and countries of Former Soviet Union were prepared. Feasible combustion technologies also were reviewed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The results shown in this thesis are based on selected publications of the 2000s decade. The work was carried out in several national and EC funded public research projects and in close cooperation with industrial partners. The main objective of the thesis was to study and quantify the most important phenomena of circulating fluidized bed combustors by developing and applying proper experimental and modelling methods using laboratory scale equipments. An understanding of the phenomena plays an essential role in the development of combustion and emission performance, and the availability and controls of CFB boilers. Experimental procedures to study fuel combustion behaviour under CFB conditions are presented in the thesis. Steady state and dynamic measurements under well controlled conditions were carried out to produce the data needed for the development of high efficiency, utility scale CFB technology. The importance of combustion control and furnace dynamics is emphasized when CFB boilers are scaled up with a once through steam cycle. Qualitative information on fuel combustion characteristics was obtained directly by comparing flue gas oxygen responses during the impulse change experiments with fuel feed. A one-dimensional, time dependent model was developed to analyse the measurement data Emission formation was studied combined with fuel combustion behaviour. Correlations were developed for NO, N2O, CO and char loading, as a function of temperature and oxygen concentration in the bed area. An online method to characterize char loading under CFB conditions was developed and validated with the pilot scale CFB tests. Finally, a new method to control air and fuel feeds in CFB combustion was introduced. The method is based on models and an analysis of the fluctuation of the flue gas oxygen concentration. The effect of high oxygen concentrations on fuel combustion behaviour was also studied to evaluate the potential of CFB boilers to apply oxygenfiring technology to CCS. In future studies, it will be necessary to go through the whole scale up chain from laboratory phenomena devices through pilot scale test rigs to large scale, commercial boilers in order to validate the applicability and scalability of the, results. This thesis shows the chain between the laboratory scale phenomena test rig (bench scale) and the CFB process test rig (pilot). CFB technology has been scaled up successfully from an industrial scale to a utility scale during the last decade. The work shown in the thesis, for its part, has supported the development by producing new detailed information on combustion under CFB conditions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The main objective of this research is creating a performance measurement system for accounting services of a large paper industry company. In this thesis there are compared different performance measurement system and then selected two systems, which are presented and compared more detailed. Performance Prism system is the used framework in this research. Performance Prism using success maps to determining objectives. Model‟s target areas are divided into five groups: stakeholder satisfaction, stakeholder contribution, strategy, processes and capabilities. The measurement system creation began by identifying stakeholders and defining their objectives. Based on the objectives are created success map. Measures are created based on the objectives and success map. Then is defined needed data for measures. In the final measurement system, there are total just over 40 measures. Each measure is defined specific target level and ownership. Number of measures is fairly large, but this is the first version of the measurement system, so the amount is acceptable.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of the study is to find out how sales performance should be measured and how should sales be steered in a multinational company. The beginning of the study concentrates on the literature regarding sales, performance measurement, sales performance measurement, and sales steering. The empirical part of the study is a case study, in which the information was acquired from interviews with the key personnel of the company. The results of the interviews and the revealed problems were analyzed, and comparison for possible solutions was performed. When measuring sales performance, it is important to discover the specific needs and objectives for such a system. Specific needs should be highlighted in the design of the system. The system should be versatile and the structure of the system should be in line with the organizational structure. The role of the sales performance measurement system was seen to be important in helping sales steering. However, the importance of personal management and especially conversations were seen as really critical issue in the steering. Sales performance measurement could be based on the following perspectives: financial, market, customer, people, and future. That way the sales department could react to the environmental changes more rapidly.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pulsed electroacoustic (PEA) method is a commonly used non-destructive technique for investigating space charges. It has been developed since early 1980s. These days there is continuing interest for better understanding of the influence of space charge on the reliability of solid electrical insulation under high electric field. The PEA method is widely used for space charge profiling for its robust and relatively inexpensive features. The PEA technique relies on a voltage impulse used to temporarily disturb the space charge equilibrium in a dielectric. The acoustic wave is generated by charge movement in the sample and detected by means of a piezoelectric film. The spatial distribution of the space charge is contained within the detected signal. The principle of such a system is already well established, and several kinds of setups have been constructed for different measurement needs. This thesis presents the design of a PEA measurement system as a systems engineering project. The operating principle and some recent developments are summarised. The steps of electrical and mechanical design of the instrument are discussed. A common procedure for measuring space charges is explained and applied to verify the functionality of the system. The measurement system is provided as an additional basic research tool for the Corporate Research Centre of ABB (China) Ltd. It can be used to characterise flat samples with thickness of 0.2–0.5 mm under DC stress. The spatial resolution of the measurement is 20 μm.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Intellectual assets have attained continuous attention in the academic field, as they are vital sources of competitive advantage and organizational performance in the contemporary knowledge intensive business environment. Intellectual capital measurement is quite thoroughly addressed in the accounting literature. However, the purpose of the measurement is to support the management of intellectual assets, but the reciprocal relationship between measurement and management has not been comprehensively considered in the literature. The theoretical motivation for this study rose from this paradox, as in order to maximise the effectiveness of knowledge management the two initiatives need to be closely integrated. The research approach of this interventionist case study is constructive. The objective is to develop the case organization’s knowledge management and intellectual capital measurement in a way that they would be closely integrated and the measurement would support the management of intellectual assets. The case analysis provides valuable practical considerations about the integration and related issues as the case company is a knowledge intensive organization in which the know-how of the employees is the central competitive asset and therefore, the management and measurement of knowledge are essential for its future success. The results suggest that the case organization is confronting challenges in managing knowledge. In order to appropriately manage knowledge processes and control the related risks, support from intellectual capital measurement is required. However, challenges in measuring intellectual capital, especially knowledge, could be recognized in the organization. By reflecting the knowledge management situation and the constructed strategy map, a new intellectual measurement system was developed for the case organization. The construction of the system as well as its indicators can be perceived to contribute to the literature, emphasizing of the importance of properly considering the organization’s knowledge situation in developing an intellectual capital measurement system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This thesis describes the process of design and modeling of instrument for knee joint kinematics measurement that can work for both in-vivo and in-vitro subjects. It is designed to be compatible with imaging machine in a sagittal plane. Due to the invasiveness of the imaging machine, the instrument is designed to be able to function independently. The flexibility of this instrument allows to measure anthropometrically different subject. Among the sixth degree of freedom of a knee, three rotational and one translational degree of freedom can be measured for both type of subject. The translational, proximal-distal, motion is stimulated by external force directly applied along its axis. These angular and linear displacements are measured by magnetic sensors and high precision potentiometers respectively