75 resultados para Measurement,


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This thesis presents the calibration and comparison of two systems, a machine vision system that uses 3 channel RGB images and a line scanning spectral system. Calibration. is the process of checking and adjusting the accuracy of a measuring instrument by comparing it with standards. For the RGB system self-calibrating methods for finding various parameters of the imaging device were developed. Color calibration was done and the colors produced by the system were compared to the known colors values of the target. Software drivers for the Sony Robot were also developed and a mechanical part to connect a camera to the robot was also designed. For the line scanning spectral system, methods for the calibrating the alignment of the system and the measurement of the dimensions of the line scanned by the system were developed. Color calibration of the spectral system is also presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aims:This study was carried out to evaluate the feasibility of two different methods to determine free flap perfusion in cancer patients undergoing major reconstructive surgery. The hypotheses was that low perfusion in the flap is associated with flap complications. Patients and methods: Between August 2002 and June 2008 at the Department of Otorhinolaryngology – Head and Neck Surgery, Department of Surgery, and at the PET Centre, Turku, 30 consecutive patients with 32 free flaps were included in this study. The perfusion of the free microvascular flaps was assessed with positron emission tomography (PET) and radioactive water ([15O] H2O) in 40 radiowater injections in 33 PET studies. Furthermore, 24 free flaps were monitored with a continuous tissue oxygen measurement using flexible polarographic catheters for an average of three postoperative days. Results: Of the 17 patients operated on for head and neck (HN) cancer and reconstructed with 18 free flaps, three re-operations were carried out due to poor tissue oxygenation as indicated by ptiO2 monitoring results and three other patients were reoperated on for postoperative hematomas in the operated area. Blood perfusion assessed with PET (BFPET) was above 2.0 mL / min / 100 g in all flaps and a low flap-to-muscle BFPET ratio appeared to correlate with poor survival of the flap. Survival in this group of HN cancer patients was 9.0 months (median, range 2.4-34.2) after a median follow-up of 11.9 months (range 1.0-61.0 months). Seven HN patients of this group are alive without any sign of recurrence and one patient has died of other causes. All of the 13 breast reconstruction patients included in the study are alive and free of disease at a median follow-up time of 27.4 months (range 13.9-35.7 months). Re-explorations were carried out in three patients due data provided by ptiO2 monitoring and one re-exploration was avoided on the basis of adequate blood perfusion assessed with PET. Two patients had donorsite morbidity and 3 patients had partial flap necrosis or fat necrosis. There were no total flap losses. Conclusions: PtiO2 monitoring is a feasible method of free flap monitoring when flap temperature is monitored and maintained close to the core temperature. When other monitoring methods give controversial results or are unavailable, [15O] H2O PET technique is feasible in the evaluation of the perfusion of the newly reconstructed free flaps.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Various strength properties of paper are measured to tell how well it resists breaks in a paper machine or in printing presses. The most often measured properties are dry tensile strength and dry tear strength. However, in many situations where paper breaks, it is not dry. For example, in web breaks after the wet pressing the dry matter content can be around 45%. Thus, wet-web strength is often a more critical paper property than dry strength. Both wet and dry strength properties of the samples were measured with a L&W tensile tester. Originally this device was not designed for the measurement of the wet web tensile strength, thus a new procedure to handle the wet samples was developed. The method was tested with Pine Kraft (never dried). The effect of different strength additives on the wet-web and dry paper tensile strength was studied. The polymers used in this experiment were aqueous solution of a cationic polyamidoamine-epichlorohydrin resin (PAE), cationic hydrophilised polyisocyanate and cationic polyvinylamine (PVAm). From all three used chemicals only Cationic PAE considerably increased the wet web strength. However it was noticed that at constant solids content all chemicals decreased the wet web tensile strength. So, since all chemicals enhanced solid content it can be concluded that they work as drainage aids, not as wet web strength additives. From all chemicals only PVAm increased the dry strength and two other chemicals even decreased the strength. As chemicals were used in strong diluted forms and were injected into the pulp slurry, not on the surface of the papersheets, changes in samples densities did not happen. Also it has to be noted that all these chemicals are mainly used to improve the wet strength after the drying of the web.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of the thesis was to create a performance measurement system for the logistics process of a company. In addition, one goal was to make suggestions for improvements based on description and analysis of the process and current measures. The logistics process was described in detail, and the objectives for it were derived from the company strategy and goals. Suggestions for performance measurement system and process improvement were made based on current state analysis. As a result of the thesis, three new performance measures were decided to take into use. In addition, several improvements were suggested to the ERP system to make process smoother. Some of the improvements have already been added to the system and the rest will be added in the near future.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this study is to create measurement system that is capable to measure performance in basic industry’s service centers. First it is examined what is performance and how it can be measured. The study also introduces commonly known measurement frameworks. After theory the study investigates how companies in the field of basic industry measure their operations in practise. The investigation is done examining three case examples and by analyzing survey results from basic industry companies. On the survey results focus is on what meters and measurement systems companies use. It is also viewed what measurement problems companies have faced. In the applied part of the study harmonized performance measurement system is created. The framework of the measurement system is introduced and measurement system for the target company is created. The target company felt that the harmonized performance measurement system has good potential and continues to develop it further.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The main objective of this research is creating a performance measurement system for accounting services of a large paper industry company. In this thesis there are compared different performance measurement system and then selected two systems, which are presented and compared more detailed. Performance Prism system is the used framework in this research. Performance Prism using success maps to determining objectives. Model‟s target areas are divided into five groups: stakeholder satisfaction, stakeholder contribution, strategy, processes and capabilities. The measurement system creation began by identifying stakeholders and defining their objectives. Based on the objectives are created success map. Measures are created based on the objectives and success map. Then is defined needed data for measures. In the final measurement system, there are total just over 40 measures. Each measure is defined specific target level and ownership. Number of measures is fairly large, but this is the first version of the measurement system, so the amount is acceptable.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of the study is to find out how sales performance should be measured and how should sales be steered in a multinational company. The beginning of the study concentrates on the literature regarding sales, performance measurement, sales performance measurement, and sales steering. The empirical part of the study is a case study, in which the information was acquired from interviews with the key personnel of the company. The results of the interviews and the revealed problems were analyzed, and comparison for possible solutions was performed. When measuring sales performance, it is important to discover the specific needs and objectives for such a system. Specific needs should be highlighted in the design of the system. The system should be versatile and the structure of the system should be in line with the organizational structure. The role of the sales performance measurement system was seen to be important in helping sales steering. However, the importance of personal management and especially conversations were seen as really critical issue in the steering. Sales performance measurement could be based on the following perspectives: financial, market, customer, people, and future. That way the sales department could react to the environmental changes more rapidly.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pulsed electroacoustic (PEA) method is a commonly used non-destructive technique for investigating space charges. It has been developed since early 1980s. These days there is continuing interest for better understanding of the influence of space charge on the reliability of solid electrical insulation under high electric field. The PEA method is widely used for space charge profiling for its robust and relatively inexpensive features. The PEA technique relies on a voltage impulse used to temporarily disturb the space charge equilibrium in a dielectric. The acoustic wave is generated by charge movement in the sample and detected by means of a piezoelectric film. The spatial distribution of the space charge is contained within the detected signal. The principle of such a system is already well established, and several kinds of setups have been constructed for different measurement needs. This thesis presents the design of a PEA measurement system as a systems engineering project. The operating principle and some recent developments are summarised. The steps of electrical and mechanical design of the instrument are discussed. A common procedure for measuring space charges is explained and applied to verify the functionality of the system. The measurement system is provided as an additional basic research tool for the Corporate Research Centre of ABB (China) Ltd. It can be used to characterise flat samples with thickness of 0.2–0.5 mm under DC stress. The spatial resolution of the measurement is 20 μm.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Intellectual assets have attained continuous attention in the academic field, as they are vital sources of competitive advantage and organizational performance in the contemporary knowledge intensive business environment. Intellectual capital measurement is quite thoroughly addressed in the accounting literature. However, the purpose of the measurement is to support the management of intellectual assets, but the reciprocal relationship between measurement and management has not been comprehensively considered in the literature. The theoretical motivation for this study rose from this paradox, as in order to maximise the effectiveness of knowledge management the two initiatives need to be closely integrated. The research approach of this interventionist case study is constructive. The objective is to develop the case organization’s knowledge management and intellectual capital measurement in a way that they would be closely integrated and the measurement would support the management of intellectual assets. The case analysis provides valuable practical considerations about the integration and related issues as the case company is a knowledge intensive organization in which the know-how of the employees is the central competitive asset and therefore, the management and measurement of knowledge are essential for its future success. The results suggest that the case organization is confronting challenges in managing knowledge. In order to appropriately manage knowledge processes and control the related risks, support from intellectual capital measurement is required. However, challenges in measuring intellectual capital, especially knowledge, could be recognized in the organization. By reflecting the knowledge management situation and the constructed strategy map, a new intellectual measurement system was developed for the case organization. The construction of the system as well as its indicators can be perceived to contribute to the literature, emphasizing of the importance of properly considering the organization’s knowledge situation in developing an intellectual capital measurement system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This thesis describes the process of design and modeling of instrument for knee joint kinematics measurement that can work for both in-vivo and in-vitro subjects. It is designed to be compatible with imaging machine in a sagittal plane. Due to the invasiveness of the imaging machine, the instrument is designed to be able to function independently. The flexibility of this instrument allows to measure anthropometrically different subject. Among the sixth degree of freedom of a knee, three rotational and one translational degree of freedom can be measured for both type of subject. The translational, proximal-distal, motion is stimulated by external force directly applied along its axis. These angular and linear displacements are measured by magnetic sensors and high precision potentiometers respectively

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this study was to find out the factors that affect customer profitability in the not-for-profit case company. The customer profitability was examined in two different segments of the customer base. The effects that price, cost and the amount of services provided have on the profit margin were studied. The distribution of profitability among the customers and the effect of certain characteristics, such as size of the customer measured in services purchased, on the profitability were analyzed. The theoretical framework was built around customer profitability and the use of customer profitability information in a not-for-profit organization. The present use of customer profitability information and the possibilities of using the results of this research in the case company were presented. Quantitative research methods were used in the empirical part of the study. The results indicate that the two customer segments have differences in their buying behaviors which affect the profitability and thus the measures taken to improve the profitability should be considered with the different characteristics of the customers in mind. Finally the limitations of the study were discussed as possible further research topics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Measurement is a tool for researching. Therefore, it is important that the measuring process is carried out correctly, without distorting the signal or the measured event. Researches of thermoelectric phenomena have been focused more on transverse thermoelectric phenomena during recent decades. Transverse Seebeck effect enables to produce thinner and faster heat flux sensor than before. Studies about transverse Seebeck effect have so far focused on materials, so in this Master’s Thesis instrumentation of transverse Seebeck effect based heat flux sensor is studied, This Master’s Thesis examines an equivalent circuit of transverse Seebeck effect heat flux sensors, their connectivity to electronics and choosing and design a right type amplifier. The research is carried out with a case study which is Gradient Heat Flux Sensors and an electrical motor. In this work, a general equivalent circuit was presented for the transverse Seebeck effect-based heat flux sensor. An amplifier was designed for the sensor of the case study, and the solution was produced for the measurement of the local heat flux of the electric motor to improve the electromagnetic compatibility.