5 resultados para Perception of Aggression Scale (POAS)
em Iowa Publications Online (IPO) - State Library, State of Iowa (Iowa), United States
Resumo:
Infectious livestock disease creates externalities for proximate animal production enterprises. The distribution of production scale within a region should influence and be influenced by these disease externalities. Taking the distribution of the unit costs of stocking an animal as primitive, we show that an increase in the variance of these unit costs reduces consumer surplus. The effect on producer surplus, total surplus, and animal concentration across feedlots depends on the demand elasticity. A subsidy to smaller herds can reduce social welfare and immiserize the farm sector by increasing the extent of disease. While Nash behavior involves excessive stocking, disease effects can be such that aggregate output declines relative to first-best. Disease externalities can induce more adoption of a cost-reducing technology by larger herds so that animals become more concentrated across herds. For strategic reasons, excess overall adoption of the innovation may occur. Larger herds are also more likely to adopt biosecurity innovations, explaining why larger herds may be less diseased in equilibrium.
Resumo:
As a result of the construction of the Saylorville Dam and Reservoir on the Des Moines River, six highway bridges are scheduled for removal. Five of these are old high-truss single-lane bridges, each bridge having several simple spans. The other bridge is a fairly modern (1955) double 4-span continuous beam-and-slab composite highway bridge. The availability of these bridges affords an unusual opportunity for study of the behavior of full-scale bridges. Because of the magnitude of the potential testing program, a feasibility study was initiated and the results are presented in this two-part final report. Part I summarizes the findings and Part II presents the supporting detailed information.
Resumo:
As a result of the construction of the Saylorville Dam and Reservoir on the Des Moines River, six highway bridges crossing the river were scheduled for removal. One of these, an old pin-connected, high-truss, single-lane bridge, was selected for a comprehensive testing program which included ultimate load tests, service load tests, and a supplementary test program. A second bridge was used for a limited service load test program. The results of the research are detailed in two interim reports. The first interim report outlines the ultimate load tests and the second interim report details the results of the service load and supplementary test program. This report presents a summary of these findings along with recommendations for implementation of the findings.
Resumo:
As a result of the construction of the Saylorville Dam and Reservoir on the Des Moines River, six highway bridges crossing the river were scheduled for removal. One of these, an old pinconnected high-truss single-lane bridge, was selected for a testing program which included ultimate load tests. The purpose of the ultimate load tests, which are summarized in this report, was to relate design and rating procedures presently used in bridge design to the field behavior of this type of truss bridge. The ultimate load tests consisted of ultimate load testing of one span of the bridge, of two I-shaped floorbeams, and of two panels of the timber deck. The theoretical capacity of each of these components is compared with the results from the field tests.
Resumo:
As a result of the construction of the Saylorville Dam and Reservoir on the Des Moines River, six highway bridges crossing the river were scheduled for removal. Two of these were incorporated into a comprehensive test program to study the behavior of old pin-connected high-truss single-lane bridges. The test program consisted of ultimate load tests, service load tests and a supplementary test program. The results reported in this report cover the service load tests on the two bridges as well as the supplementary tests, both static and fatigue, of eyebar members removed from the two bridges. The field test results of the service loading are compared with theoretical results of the truss analysis.